•.~~~.Entergy
GNRO-2012/00093
August 15, 2012
U.S. Nuclear Regulatory CommissionAttn: Document Control DeskWashington, DC 20555
Entergy Operations, Inc.P. O. Box 756Port Gibson. MS 39150
Michael PeritoVice President. OperationsGrand Gulf Nuclear StationTel. (601) 437~409
SUBJECT:
REFERENCE: '
Dear Sir or Madam:
License Renewal Application 2012 Annual UpdateGrand Gulf Nuclear Station, Unit 1Docket No. 50-416License No. NPF-29
Letter to Nuclear Regulatory Commission, "License Renewal ApplicationGrand Gulf Nuclear Station, Unit 1," dated October 28, 2011 (GNRO2011/00093)
The purpose of this letter is to provide the Nuclear Regulatory Commission (NRC) an annualupdate to the referenced Grand Gulf Nuclear Station (GGNS) License Renewal Application(LRA), in accordance with 10 CFR 54.21 (b). During NRC review of the GGNS LRA, GGNS isrequired by 10 CFR 54.21 (b) to provide an annual report of changes to the GGNS currentlicensing basis (CLB) that materially affects the contents of the GGNS LRA, including the FinalSafety Analysis Report supplement. GGNS has completed the annual CLB review and isproviding, in the Attachment, the changes to the LRA required by this review
This letter contains no new commitments. If you have any questions or require additionalinformation, please contact Christina L. Perino at 601-437-6299.
I declare under penalty of perjury that the foregoing is true and correct. Executed on the 15th
day of August, 2012.
MP/jas
Attachment: (see next page)
GNRO-2012/00093Page 2 of 2
Attachment: CLB Changes to LRA
cc: with Attachment
Mr. John P. Boska, Project ManagerPlant Licensing Branch 1-1Division of Operating Reactor LicensingOffice of Nuclear Reactor RegulationU.S. Nuclear Regulatory CommissionMail Stop 0-8-C2Washington, DC 20555
cc: without Attachment
Mr. Elmo E. Collins, Jr.Regional Administrator, Region IVU.S. Nuclear Regulatory Commission1600 East Lamar BoulevardArlington, TX 76011-4511
U.S. Nuclear Regulatory CommissionATTN: Mr. A. Wang, NRRlDORLMail Stop OWFN/8 G1411555 Rockville PikeRockville, MD 20852-2378
U.S. Nuclear Regulatory CommissionATTN: Mr. Nathaniel Ferrer NRRlDLRMail Stop OWFNI 11 F111555 Rockville PikeRockville, MD 20852-2378
NRC Senior Resident InspectorGrand Gulf Nuclear StationPort Gibson, MS 39150
Attachment
GNRO-2012100093
CLB Changes to LRA
Attachment to GNRO-2012/00093Page 1 of 15
The following changes are required for the Grand Gulf Nuclear Station (GGNS) License RenewalApplication (LRA) in accordance with 10 CFR 54.21 (b) as a result of current license basis changes thathave occurred at GGNS since the submittal of the license renewal application. This includes changesmade during the recent extended power uprate outage. Changes are shown with strikethroughs fordeletions and underlines for additions.
Table 2.3.3-6Fuel Pool Cooling and Cleanup System
Components Subject to Aging Management Review
Component Type Intended Function
Bolting Pressure boundary
Diffuser Pressure boundary
Flow element Pressure boundary
!=Ieat eKel=laRger (BeRRet) Pressl:IFe B91:1RElary
!=Ieat eKel=laRger (sI=I911) Pressl:Ire B91:1RElary
!=Ieat eKel=laRger (tl:lBe sl=Ieets) Pressl:Ire B91:1RElary
!=Ieat eKel=laRger (tl:lBes) Pressl:Ire B91:1RElary
!=Ieat traRsfer
Heat exchanger (end covers) Pressure boundary
Heat exchanger (plates) Pressure boundarv
Heat transfer
Neutron absorber Neutron absorption
en
~ ! ! !s~ ~ ~ <.J) <.J) <.J)0z
J!E ; ~ ; ~ ~ ~ ~ ~ ~ ~.asea-1- ....
I E ~B ~ c ; ~B ~ ; ~
~ ~.; .; T T T
CJcP~ ~ ~ ~ ~ ~ ~ ~w=a:: ....
~C) : ( ( ,," ,,' ( ,,' (Zco < < <.... .. " -.~
-' -. -.~
-.:: : § § :: ~ :
j1... ! . I~
~
" Ig " Ig... ~
!J... .-55 en " J i
( 1
I;1 I" i " 5
ImEE ( 3 Is ( c 15 15 ((~ I ( 3e cP ea.- m" ( .., ( i
{ 11( (meam
Cel:! i i c c c Cea~ .. .. 1 1 I 1 4 ( I:& (, I : : « 3 Ie:::: I ;: ~ ~ ~ :::
- -~ mee cP
f f=.- Ew.~ cPm~m '( '( .. .. .. '( '( '(e i ea._ e
lb : l l :ma:: eaC :& ( c ( ( (
-u - - - -
t ~~~~ r:-
~:~r:-
~~:; 11:-- ~r:-
~v ~e ~Ii 'v ~l:-,
cP : ( c c i :E c i • i i i ie~IJ0 i :
E .. j
!.s;e
:.? ~>0 W <~en I I I I IQ,~
i i J ie
:i
jJ jJ jJ jJ j jJII
I..(3 cP'0 1;
Ct) e :&0) ea0 m0 .5
I I~ '0 ia If If If If If If Jf ifT"" 0
'0:0=0 (.) e uC\I '0 cP eI
0 -~0 .Eu.et ~
z 'ii(!) ~
.91.0U. - ~ D
'I 1~ ~cD e Il
- T"" I CP
I J i 1 t I I I Ie_ N al0)0 C"iEC\I C"i Q,>o
I I I : I..c EI-1(,)0) J! 0 11 1 1 : 1 1 .
cae:» .a (.)~ :l ~ ~ ~ ~:=::ca ea j j j :«0.. I- - ...J - - -
Attachment to GNRO-2012/00093Page 3 of 15
Table 3.3.2-6: Fuel Pool Cooling and Cleanup System
Component Intended Aging Effect AgingNUREG- TableMaterial Environment Requiring ManagementType Function
Management Programs 1801 Item 1 Item Notes
Heat exchanger PressureCarbon steel Air - indoor [ext] Loss of material
External Surfaces VII.I.A-77 3.3.1-78 A-(end cover) boundary Monitoring
Heat exchanger PressureCarbon steel Treated water [int] Loss of material
Water Chemistry VII.E3.AP-106 3.3.1-21 C,301(end cover) boundary Control -BWR
Water ChemistryHeat exchanger Pressure
Carbon steel Treated water [int] Loss of materialControl - Closed VII.A4.AP-189 3.3.1-46 A-(end cover) boundary Treated Water
Systems
Heat exchanger Pressure StainlessAir - indoor [ext] None None VII.J.AP-123 3.3.1-120 C(plates) boundary steel
Heat exchangerHeat transfer
Stainless Treated water [int] FoulingWater Chemistry VII.A4.AP-139 3.3.1-17 C
(plates) steel Control -BWR
Heat exchanger Pressure Stainless Treated water [int] Loss of materialWater Chemistry VII.A4.AP-111 3.3.1-25 A,301
(plates) boundary steel Control -BWR
Water ChemistryHeat exchanger
Heat transferStainless
Treated water [int] FoulingControl - Closed VII.C2.AP-188 3.3.1-50 Q(plates) steel Treated Water
Systems
Water ChemistryHeat exchanger Pressure Stainless Treated water [int] Loss of material
Control - ClosedVII.C2.A-52 3.3.1-49 Q(plates) boundary steel Treated Water
Systems
Attachment to GNRO-2012/00093Page 4 of 15
Table 2.3.3-8Component Cooling Water System
Components SUbject to Aging Management Review
Component Type Intended Function
Bolting Pressure boundary
Flow element Pressure boundary
Piping Pressure boundary
Strainer Housing Pressure boundary
Strainer Filtration
Tubing Pressure boundary
Valve body Pressure boundary
Attachment to GNRO-2012/00093Page 5 of 15
Table 3.3.2-8: Component Cooling Water System
Component Intended Aging Effect AgingNUREG- Table 1
Type Function Material Environment Requiring Management 1801 Item ItemNotes
Management Program
Strainer PressureCarbon steel Air- indoor
Loss of materialExternal Surfaces VI I. I.A-77 3.3.1-78 Ahousing boundary (ext) Monitoring
Water ChemistryStrainer Pressure
Carbon steelTreated water
Loss of materialControl - Closed VII.C2.AP-202 3.3.1-45 Ahousing boundary (int) Treated Water
Systems
Water Chemistry
Strainer Filtration Stainless steelTreated water
Loss of materialControl - Closed VII.C2.A-52 3.3.1-49 A(int) Treated Water
Systems
Water Chemistry
Strainer Filtration Stainless steel Treated waterLoss of material
Control - ClosedVII.C2.A-52 3.3.1-49 A(ext) Treated Water
Systems
Attachment to GNRO-2012/00093Page 6 of 15
Table 3.3.2-7: Standby Service Water System
Component Intended Aging Effect Aging NUREG- Table 1Type Function Material Environment Requiring Management 1801 Item Item
NotesManagement Program
Piping PressureStainless steel
CondensationLoss of material
External Surfaces Gboundary (ext) Monitoring -- --
Piping PressureStainless steel Raw water (ext) Loss of material
Service Water VII.C1.A-54 3.3.1-40 Aboundary Integrity
Piping PressureStainless steel Raw water (int) Loss of material
Service Water VII.C1.A-54 3.3.1-40 Aboundary Integrity
Piping PressureStainless steel Soil (ext) Loss of material
Buried Piping and G-- --boundary Tanks Inspection - -
Table 2.4-2Water Control Structures
Components SUbject to Aging Management Review
Intended Function1
Cooling tower drift eliminators Heat sinkSupport for Criterion (a)(2) equipment
Attachment to GNRO-2012/00093Page 7 of 15
Table 3.5.2-2Water Control Structures
Summary of Aging Management Evaluation
Table 3.5.2-2: Water Control Structures
StructureAging Effect Agingand/or Intended NUREG- Table 1
Component or Function Material Environment Requiring Management 1801 Item ItemNotes
Commodity Management Program
Cooling tower driftHS,SNS Stainless Steel
Exposed to fluidLoss of material
Structures III.A8.T-23 3.5.1-52 geliminators environment monitorina
Attachment to GNRO-2012/00093Page 8 of 15
Table 2.3.1-3Reactor Coolant Pressure Boundary
Components SUbject to Aging Management Review
Component Type Intended Function
Thermowell Pressure boundary
TheFFReweli (ReR Class 1) PFesslolFe gelolRElaFY
Attachment to GNRO-2012100093Page 9 of 15
Table 3.1.2-3Reactor Coolant Pressure Boundary
Summary of Aging Management Evaluation
Table 3.1.2-3: Reactor Coolant Pressure Boundary
Aging Effect Aging
I NUREG- I Table I NotesComponent Intended
Material Environment Requiring Management 1801 Item 1 ItemType FunctionManagement Program
Air iREl99r Ex-terRal S...rlases I V.E.E 44 I 3.2.1 4Q I G;--143Tl:lerm9well (R9R Press...re
b9SS 9t materialCarB9R steel(ext) M9Rit9riRgClass 1) B9...RElary
Tl:lerm9well (R9R Press...re TreateEl waterb9SS 9f material WaterCl:lemistry IIV.C1.RP 1581 3.1.179 I A;-+O+CarB9R steel
{fAt} C9Rtr91 iWRClass 1) B9"'RElary
Table 2.3.4-2-13Seal Oil System
Nonsafety-Related Components Affecting Safety-Related SystemsComponents SUbject to Aging Management Review
Component Type Intended Function(s)1
Bolting Pressure boundary
Filter housing Pressure boundary
Heat e*sl:laRger (B9RRet) Press...re B9...RElary
Heat e*sl:laRger (sl:lell) Press...re B9...RElary
Heat exchanger (end covers) Pressure boundary
Heat exchanger (plates) Pressure boundary
Attachment to GNRO-2012/00093Page 10 of 15
Table 3.4.2-2-13Seal Oil System
Nonsafety-Related Components Affecting Safety-Related SystemsSummary of Aging Management Evaluation
Table 3.4.2-2-13: Seal Oil System, Nonsafety-Related Components Affecting Safety-Related Systems
Component Intended Aging Effect Aging Management NUREG-1801Material Environment Requiring Table 1 Item Notes
Type Function Management Programs Item
Weat PFeSSI::lr:e .6,iF iRd99F ~xteFRal Sl::IrlaGeseXGRaRgeF CaF99R steel b9ss 9' mateFial VIII.H.S 29 3.4.1 34 A991::1RdaFy (ext) M9Rit9FiRg
WateF CRemistl)'Weat Pr:eSS1::1Fe Tr:eated wateF C9RtF91 CI9sedeXGRaRgeF CaF99R steel b9ss 9f mateFial VIII.E.S 23 3.4.1 25 G991::1RdaFy ~ TFeated WateF(99RRet) ~
Weat PFeSSI::IFe A" iRd99F ~xteFRal Sl::IrlaGeseXGRaRgeF CaF99R steel rolFb9ss 9' mateFial VIIIH.S 29 3.4.1 34 A
991::1RdaFy (ext) M9Rit9FiRg~Weat PFeSSI::IFeeXGRaRgeF CaF99R steel bl::lge 9il (iRt) b9SS 9' mateFial Oil ARalysis VIII.A.SP 29 3.4.1 40 ~991::1RdaFy
fsRemHeat Pressure Air - indoor External Surfacesexchanger boundary Carbon steel [ext] Loss of material Monitoring
VIII.H.S-29 3.4.1-34 A(end cover)
Heat Pressureexchanger boundary Carbon steel Lube oil (int) Loss of material Oil Analysis VIII.A.SP-91 3.4.1-40 C,402lend cover)
Heat Water ChemistryPressure Treated water Control - Closedexchanger boundary Carbon steel [int] Loss of material Treated Water
VII I.E.S-23 3.4.1-25 C(end cover)
SvstemsHeat Pressure Stainless Air - indoorexchanger boundary steel [ext] None None VIII.I.SP-12 3.4.1-58 Q
(Dlates)
Attachment to GNRO-2012/00093Page 11 of 15
h"able 3.4.2-2-13: Seal Oil System, Nonsafety-Related Components Affecting Safety-Related Systems
Component Intended Aging EffectAging Management NUREG-1801Material Environment Requiring Table 1 Item NotesType Function
ManagementPrograms Item
HeatPressure Stainlessexchangerboundary steel
Lube oil (int) Loss of material Oil Analysis VIII.G.SP-79 3.4.1-44 C,4027DiateS\
Heat Water ChemistryPressure Stainless Treated water Control - Closedexchangerboundary steel [int] Loss of material
Treated WaterVII I.E.S-25 3.4.1-26 C
(plates)Systems
Carben steelPump casing Pressure
Gray cast Lube oil (int) Loss of material Oil Analysis VIlI.A.SP-91 3.4.1-40 C,402boundary
ironCarben steel
Pump casing PressureGray cast Air- indoor
Loss of materialExternal Surfaces
VIII.H.S-29 3.4.1-34 Aboundary
iron (ext) Monitoring
Attachment to GNRO-2012/00093Page 12 of 15
Table 2.3.3-19-19Plant Service Water System
Nonsafety-Related Components Affecting Safety-Related SystemsComponents SUbject to Aging Management Review
Component Type Intended Function1
Bolting Pressure boundary
Ejector Pressure boundary
Flow element Pressure boundary
Piping Pressure boundary
Pump Pressure Boundary
Sight glass Pressure Boundary
Strainer housing Pressure boundary
Tank Pressure boundary
Thermowell Pressure boundary
Tubing Pressure boundary
Valve body Pressure boundary
Attachment to GNRO-2012/00093Page 13 of 15
Table 3.3.2-19-19Plant Service Water System
Nonsafety-Related Components Affecting Safety-Related SystemsSummary of Aging Management Evaluation
Table 3.3.2-19-19: Plant Service Water System [10 CFR 54.4(a)(2)]
Component IntendedAging Effect Aging NUREG- Table 1
Type Function Material Environment Requiring Management 1801 Item Item NotesManagement Program
Piping PressureStainless steel
Condensation Loss of materialExternal Surfaces G
Monitoring-- --
boundary (ext) - -
Piping PressureStainless steel Raw water (int) Loss of material
Service Water VII.C1.A-54 3.3.1-40 ~boundary Integrity
Pump casing PressureStainless steel Raw water (int) Loss of material
Service Water VII.C1.A-54 3.3.1-40 ~boundary Integrity
Pump casingPressure
Stainless steelCondensation Loss of material
External Surfaces Gboundary (ext) Monitoring -- --- -
Sight glassPressure
Stainless steel Raw water (int) Loss of materialService Water VII.C1.A-54 3.3.1-40 ~boundary Integritv
Sight glassPressure
Stainless steel Condensation Loss of materialExternal Surfaces G
boundary (ext) Monitoring -- --- -
Change inInternal Surfaces
Pressure in MiscellaneousSight glass Plastic Raw water (int) material Eboundary Piping and Ducting-- --- -
propertiesComponents
Pressure Condensation Change in External SurfacesSight glass Plastic material Eboundary (ext) Monitoring -- --- -properties
TankPressure
Carbon steel Raw water (int) Loss of materialService Water VII.C1.AP-183 3.3.1-38 ~boundary Integrity
Attachment to GNRO-2012/00093Page 14 of 15
Table 3.3.2-19-19: Plant Service Water System [10 CFR 54.4(a)(2)]
Component. Intended Aging Effect Aging NUREG- Table 1Type Function Material Environment Requiring Management 1801 Item Item
NotesManagement Program
Tank PressureCarbon steel Condensation Loss of material
External Surfaces VI I. I.A-81 3.3.1-78 Aboundary (ext) Monitoring
Valve body PressureStainless steel Condensation
Loss of materialExternal Surfaces G
boundarv (ext) Monitoring -- --- -
Valve body PressureStainless steel Raw water (int) Loss of material
Service Water VII.C1.A-54 3.3.1-40 Aboundary Integrity
Attachment to GNRO-2012/00093Page 15 of 15
Section 2.3.4.2
Condensate Cleanup
The purpose of the condensate cleanup system (system code N22) is to maintain the required purity of feedwater flowing tothe reactor. Normally, demineralizers are in operation processing full condensate flow. The condensate cleanup systemconsists of eight units of deep-bed-type demineralizers (with two units as spares) that operate in parallel, and thFss pFsooatfiltsFs (with ons unit as spam) a condensate full flow filtration system used for startup. The system also includes theassociated piping, ultrasonic resin cleaner, the advanced resin cleaning subsystem, and all necessary valves,instrumentation and controls.
Table 3.4.2-2-4Condensate Cleanup System
Nonsafety-Related Components Affecting Safety-Related SystemsSummary of Aging Management Evaluation
Table 3.4.2-2-4: Condensate Cleanup System, Nonsafety-Related Components Affecting Safety-Related Systems
Component Intended Aging Effect Aging NUREG- Table 1Type Function Material Environment Requiring Management 1801 Item Item Notes
Management Program
Flow element PressureStainless steel Air - indoor (ext) None None VIII.I.SP-12 3.4.1-58 Aboundary
Flow elementPressure
Stainless steel Treated waterLoss of material Water Chemistry VIII.E.SP-87 3.4.1-16 A, 401boundary (int) Control - BWR