Gold Miner IV CIRCUIT ANALYZER, CT TESTER & METER TESTER Instantanious Analysis of All Power Parameters Gold Miner performs circuit analysis and wiring verificaon on ALL phases for both Primary and Secondary circuit at the same me. Vector Diagrams, Harmonic Analysis, Input Waveforms and Tables with the numerical values of Voltage, Current, Phase Shiſt, Power, frequency are displayed on different screens. VT Tesng Voltage transformers can be tested for turn rao and phase dis- placement angle with HV voltage probe (for the primary side) and one of the voltage inputs (for the secondary side) Demagnezaon Demagnezaon of an operang current transformer can be carried out if the secondary circuit resistance is increased step- wise ll the core gets into saturaon, and thereaſter is again stepwise decreased. The lower the secondary circuit current, the greater the resistance required for saturaon. We ensure for demagnezaon resistances up to 50Ω and power up to 100VA. Improved Accuracy – 0.04% max The electronic components used in the three-phase analyzing standard are with lower temperature and annual driſt and show excellent repeatability of measurement. User Safety Design 600V CAT IV for a measuring instrument means that it can be operated on outdoor installaons with rated voltage up to 600V, and that it can support instantaneous overvoltage up to 7kV. To make our instrument safe for operaon under most difficult condions, we undertook the following changes in Gold Miner: - safety fused voltage test leads; - no metal parts – all sockets and the panel are plasc; - the analog inputs withstand up to 7kV electrostac discharge. Features True three phase energy standard, 0.04% accuracy In service verificaon of energy meters kWh, kVARh, kVAh Full power tables, vector diagram, osciloscope funcon Simultaneous three phase CT burden and rao test Current transformer demagnezaon Turns raon tesng of potenal transformers Harmonic analysis up to 49 th harmonic On board data collecon and management 600 Volt Cat IV Simultaneous Accuracy Tesng of the Enre Measurement Circuit If you don’t measure it, you can’t manage it. Gold Miner is the first device of its type to test the electricity meter using exact, si- multaneous measurements made on all primary and all second- ary phases of the circuit. Perform in-service meter tesng with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true ac- curacy resulng from the CTs + Meter combinaon for your en- re measurement circuit. Automac CT Burden & Rao Tesng of ALL Phases without Interrupon With the push of a buon, CT Burden and Rao Tests are per- formed on all phases, without interrupon. This is the fastest and safest way to test. You can view all burden graphs and tables from any test site directly from memory on the large LCD display.

Upload: others

Post on 21-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gold Miner IV - EMSYST · Gold Miner IV CIRCUIT ANALYZER, CT TESTER & METER TESTER Instantanious Analysis of All Power Parameters Gold Miner performs circuit analysis and wiring verification

Gold Miner IVCIRCUIT ANALYZER, CT TESTER & METER TESTER

Instantanious Analysis of All Power ParametersGold Miner performs circuit analysis and wiring verification on ALL phases for both Primary and Secondary circuit at the same time. Vector Diagrams, Harmonic Analysis, Input Waveforms and Tables with the numerical values of Voltage, Current, Phase Shift, Power, frequency are displayed on different screens.

VT TestingVoltage transformers can be tested for turn ratio and phase dis-placement angle with HV voltage probe (for the primary side) and one of the voltage inputs (for the secondary side)

DemagnetizationDemagnetization of an operating current transformer can be carried out if the secondary circuit resistance is increased step-wise till the core gets into saturation, and thereafter is again stepwise decreased. The lower the secondary circuit current, the greater the resistance required for saturation. We ensure for demagnetization resistances up to 50Ω and power up to 100VA.

Improved Accuracy – 0.04% maxThe electronic components used in the three-phase analyzing standard are with lower temperature and annual drift and show excellent repeatability of measurement.

User Safety Design 600V CAT IV for a measuring instrument means that it can be operated on outdoor installations with rated voltage up to 600V, and that it can support instantaneous overvoltage up to 7kV.To make our instrument safe for operation under most difficult conditions, we undertook the following changes in Gold Miner:- safety fused voltage test leads;- no metal parts – all sockets and the panel are plastic;- the analog inputs withstand up to 7kV electrostatic discharge.

Features True three phase energy standard, 0.04% accuracy In service verification of energy meters kWh, kVARh, kVAh Full power tables, vector diagram, osciloscope function Simultaneous three phase CT burden and ratio test Current transformer demagnetization Turns ration testing of potential transformers Harmonic analysis up to 49th harmonic On board data collection and management 600 Volt Cat IV

Simultaneous Accuracy Testing of the Entire Measurement Circuit If you don’t measure it, you can’t manage it. Gold Miner is the first device of its type to test the electricity meter using exact, si-multaneous measurements made on all primary and all second-ary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true ac-curacy resulting from the CTs + Meter combination for your en-tire measurement circuit.

Automatic CT Burden & Ratio Testing of ALL Phases without InterruptionWith the push of a button, CT Burden and Ratio Tests are per-formed on all phases, without interruption. This is the fastest and safest way to test. You can view all burden graphs and tables from any test site directly from memory on the large LCD display.

Page 2: Gold Miner IV - EMSYST · Gold Miner IV CIRCUIT ANALYZER, CT TESTER & METER TESTER Instantanious Analysis of All Power Parameters Gold Miner performs circuit analysis and wiring verification

The On-Board ConsultantDuring testing, Gold Miner automatically searches for a variety of possible conditions on your circuit, which may warrant your attention. Upon detection, the on-board Consultant explains its findings, and provides guidance for further investigation so you may ultimately make money-saving corrections.

Save and View Saved FilesGold Miner IV stores up to 100 test sites in a non-volatile memory. All these files can be transferred to a PC via USB port or viewed on the display of the unit. When saving, the operator need only enter the Location name and the ID Number of the meter. The date and time are automatically saved.

Testmet SoftwareTestmet Software uses MySQL Database. Searches with different criteria may be performed and Test Reports viewed and printed. The operator is able to customize the heading of the Report and add additional notes.

Standard EquipmentThe Gold Miner™ IV3 Flexible Primary Probes (36 in. loop, 24 ft. length)3 Test Plugs (Duckbills)5 Voltage Leads with Fused Crocodile Clips1 Universal Scanning Head (Pick-up) for counting the pulses of electronic meters or the rotations of mechanical meters1 Hand-switch for meter testing1 Rugged, Integrated Carrying Case1 Li-Ion Battery Pack and Charger Kit

Optional Equipment1 HV Optical Voltage Probe (40kV)1 HV Optical Current Probe (2000A)1 Primary Current Clamp (1000A)3 Secondary Current Clamps (200A)3 Extension Cables for Flexible Probes (24 ft. each)

SpecificationsVoltage Inputs: 4-Channels, 10V ... 690V-rms 1-Channel HV Optical Voltage Probe (40kV)Current Inputs: 3-Channels for Flexible Probes (10A ... 3000A) 3-Channels for Test Plugs (0.1A ... 20A) 3-Channel for Sec. Current Clamps (1A ... 200A) 1-Channel for HV Current Probe (20A ... 2000A) 1-Channel for Prim. Current Clamp (5A ... 1000A)Energy Meas: kWh, kVARh, kVAh +/-0.04% Accuracy (with Test Plugs)Power Meas: kW, kVAR, kVA per-phase & system valuesBurden Test: 0.1Ω 0.2Ω 0.5Ω 1.0Ω 2.0Ω 4.0Ω, SelectableRatio Test: +/-0.2% Accuracy (typical)Phase Shift: +/-0.1 degree Accuracy (typical) when using Flexible Probes and Test PlugsHarmonics: Measures to the 49th harmonic Measures THD (Total Harmonic Distortion)Power Factor: -1.000 to +1.000 with +/-0.05% AccuracyDemag: Up to 50Ω, 100VA Memory: Stores data for up to 100 SitesData Interface: USB PortPower Supply: Li-Ion Rechargeable Battery Pack Battery Life > 8 hours (typical)

TESTMET Inc.www.testmet.com

C9450 Mira Mesa Blvd, Suite C202 San Diego, CA 92126 Phone (952) 486-7653Fax (952) 392-2218Support Hotline (858) [email protected]

1 Select any or all Tests 2 One Global Setup Screen 3 Run your TestsFAST AND EASY AS 1-2-3

Valuable Results at your Fingertips

Transfer to your PC or Laptop

Print Professional Reports with testMET™ Software