Page 1: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

UL Type Examination CertificateUL Certification Marks

GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES

Page 2: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

MV SWITCHGEAR ASSEMBLIESThe term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and is commonly used to refer to voltages up to 52kV. UL can provide the following services for MV equipment designed to meet IEC standards as well as ANSI (UL/NEMA/IEEE/CSA) standards:

• UL Type Examination Certificate to IEC 62271 Series

• UL Certification Marks: - IEC 62271 Series - UL/IEEE/NEMA/CSA Standards

Power Transmission and Distribution

Type Examination or Certification to IEC Standards

General requirements for MV Assembly IEC 62271-1

High-voltage switchgear and Controlgear Part 200: AC metal-enclosed switchgear and Controlgear for rated voltages above 1 kV and up to and including 52 kV

IEC 62271-200(Replaces IEC 60298)

High-voltage switchgear and Controlgear – Part 201: AC insulation-enclosed switchgear and Controlgear for rated voltages above 1 kV and up to and including 52 kV

IEC 62271-201

High-voltage switchgear and Controlgear – Part 202:High-voltage/low-voltage pre-fabricated substation

IEC 62271-202

High-voltage switchgear and Controlgear Part 203:Gas-insulated metal-enclosed switchgear for ratedvoltages above 52 kV

IEC 62271-203(Replaces IEC 60517)

Certification to ANSI (UL/NEMA/IEEE/CSA) Standards

MV Vacuum Circuit Breakers and Metal Clad Switchgear

ANSI/IEEE C37.20.2; ANSI/NEMA C37.54 / C37.55; CSA C22.2 No. 31

MV Gas Insulated Circuit Breakers and Switchgear

ANSI/IEEE C37.20.3; ANSI/NEMA C37.54 / C37.55; CSA C22.2 No. 31

Metal Enclosed Bus Bar / Bus Bar Trunking Systems

ANSI/IEEE C37.23 or CSA C22.2 No. 201

MV Controllers and Motor Control Centers ANSI/UL 347 and UL 347B; CSA C22.2 No. 253

MV Variable Frequency Drives ANSI /UL 347 and UL347A; CSA C22.2. No. 174

Equipment additionally evaluated for Arc Resistance

ANSI/IEEE C37.20.7; CSA C22.2 No. 0.22

Page 3: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

LV SWITCHGEARUL offers multiple means to enable manufacturers to demonstrate to Regulators, Consultants and End users that LV Switchgear supplied is designed, built, independently tested / evaluated and continually certified to the requirements of the standard as well as to additional performance specifications demanded by different markets and buyers.

The IEC 61439 standard requires manufacturers (OEM’s and Assemblers) to demonstrate Type compliance to IEC 61439 by Evaluation of Switchgear Assemblies in line with Annex D of IEC 61439-1:2011.

UL Type Examination Certificate

This is an ISO Guide 65/67 Type 1a Certification scheme demonstrating that the submitted (type) design is independently evaluated and covers the following services:

• UL qualified staff evaluate the test laboratory as per ISO / IEC 17025 guidelines, ILAC accreditation requirements and additional requirements of UL’s Data Acceptance Program (DAP)

• Under UL’s Witness Test Data Program (WTDP) a qualified staff member acts as the Evaluator (planner and observer) for all points of the Type Examination (Formulation of test plan in accordance with the applicable IEC standard, completion of construction evaluation, type testing or equivalent, and completion of test report

• Another qualified staff member acts as a Reviewer during finalization of test plan, validation of test data, completion of the examination and report, including the signature on the Type Examination Summary

• The Test Report is processed by the Certification Office (UL Denmark / DEMKO), after which the UL Type Examination Certificate is issued in both electronic and original formats

• Certificate Numbers may be validated by writing to [email protected]

UL is designated by the IEC EE (IEC System for Conformity testing and Certification of Electrotechnical Equipment and Components) as a National Certification Body (NCB) under the IEC CB Scheme (Approved Certification Body to issue IEC CB Scheme Certificates). The CB Scheme is based on the use of CB Test Certificates which provide evidence that representative specimens of the product have successfully passed type tests to show compliance with the requirements of the relevant IEC standard.

The IEC 61439 series has been adopted by the European Electrotechnical standardization body, CENELEC (as the EN 61439 series), thus presenting a harmonization system for meeting additional European specific requirements. The UL Type Examination Certificate can be combined with the IEC CB Scheme Certificate if tested under the WMT / SMT data acceptance requirements of the IEC CB Scheme.

Page 4: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

UL Certification Mark to IEC Standards

The UL Classification Mark is an ISO Guide 65/67 Type 5 scheme that gives the opportunity to a manufacturer to demonstrate continued compliance to the Type Examination requirements of the IEC 61439 standard group with the benefit of real time online listing on the UL Online Certifications Directory. This offers the highest level of integrity and compliance in the market for switchgear assemblies.

• The UL Type Examination program rules apply for the evaluation and issue of Test Reports, Type Examination Certificates, and Type Examination Summarys

• All critical components must be independently third party certified to comply with applicable IEC product standards as evidenced by the Certification Mark of a recognized Certification body. Test data must be made available as generated under UL’s DAP program requirements

• Selection and design of sections and functional units are controlled modifications are allowed only as specifically described in the certification program documents

• Panel Labels with a copyrighted Mark must be procured with a serial number from UL’s Label Center only

• An additional Certificate of Compliance (CoC) is issued by UL LLC, US with a unique File Number that is traceable at www.ul.com/database

• Can be combined with the IEC CB Scheme if issued as per IECEE guidelines

UL TYPE EXAMINATION CERTIFICATE

Certification ManagerJan-Erik Storgaard

This is to certify that the sample(s) of the Product described herein has been investigated to and found to have been in compliance with the Standard(s) indicated on this Certificate, in accordance with the UL Type Examination Certificate Program Requirements. This certificate and test results obtained apply only to the product sample(s) submitted by the Applicant. UL did not select the sample(s) or determine whether the sample(s) provided were representative of other manufactured products. UL has not established Follow-Up Service or other surveillance of the product. The Applicant/ Manufacturer are solely and fully responsible for conformity of all products to all applicable Standard(s), specifications orrequirements. The test results may not be used, in whole or in part, in any other document without UL’s prior written approval.

Certification Body UL International Demko A/S, Borupvang 5A, 2750 Ballerup, Denmark, Tel. +45 44 85 65 65 [email protected], www.ul.com

Certificate No. XXXXXXXXX.XXXXXX Page 1/1

Date of Issue 2013-MM-DD

Applicant ABC Co. Safety Road 1 Electric City ABC Co. Denmark

Manufacturer ABC Co. Safety Road 1 Electric City ABC Co. Denmark

Product Sample Description Low Voltage Power Switchgear and Controlgear Assembly (Panel Board) , Non extendable type

Designation PTC-DB-160

Ratings Rated operational voltage (Ue): 380V Rated current (Un): XXXXXXX Rated frequency: 50 Hz IP rating : IP 54

Product Sample Tested and found in compliance with

Standard(s)

IEC 61439-1(ed. 2), IEC 61439-2(ed. 2)

Test Report Nos. 13CA12345 issue date 2013-01-01 (XX pages), Refer document no. 13CA12345-S issue date 2013-01-05 (XX pages ) For Type examination summary

Additional information N/A

UL Type Examination Certificate UL Certification Mark Program

Page 5: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

LV Assembly Product Categories – UL Services

Product Type UL Certification / UL Type Examination Certificate (IEC Standards)

UL Certification Mark for the US and Canada

LV Power Control Center / LV Metal Enclosed Switchgear Assembly

IEC 61439-1 and -2ANSI/IEEE C37.20.1 and ANSI/UL 845; CSA C22.2 No. 31 and No. 254

LV Switchboards IEC 61439-1 and -2 ANSI/UL 891; CSA C22.2 No. 244

LV Panelboards IEC 61439-1, -2 and -5 ANSI/UL 67; CSA C22.2 No. 29

Busways (Bus Trunking Systems) IEC 61439-1 and -6 ANSI/UL 857; CSA C22.2 No. 27

Empty Enclosures for Switchgear Panels IEC 62208ANSI/UL 50 and ANSI/UL 50E; CSA C22.2 No. 94.1 and No. 94.2

Industrial Control Panels IEC 61439-1; IEC 61439-2 and IEC 60204-1 ANSI/UL 508A; CSA C22.2 No. 14

LV Fire Pump Control Panels IEC 62091ANSI/UL 508 and ANSI/UL 218; CSA C22.2 No. 263

North American Installation Code and Compliance Requirements

The North American market, especially the US, Canada and Mexico, have fundamental infrastructural differences. This is due to fundamental differences in Voltages, fault levels, frequency and wiring techniques. The National Electrical Code (NEC), which is the most widely adopted Electrical Code in the US, provides installation and wiring practices for the US.

The Occupational Safety and Health Administration (OSHA) requires an NRTL (Nationally Recognized Testing Laboratory) such as UL to test and certify assemblies to indicate compliance with the appropriate American National (ANSI) product standards. The UL Listing Mark is the most widely accepted NRTL Mark across regulators (AHJ’s) and consultants and

indicates that the assemblies meet the minimum Thermal, Fire and Electrical hazard SAFETY requirements as specified by the appropriate ANSI standards. Conformity Assessment is performed to ANSI standards. ANSI standards are developed by various Standard Development Organizations (SDOs) such as UL, IEEE, NEMA, NFPA etc.

Enhanced UL Certification Mark

As a further development of the classic Listing and Classification Marks, UL now offers the enhanced UL Certification Mark, which anticipates the future needs and evolving nature of product safety. The enhanced UL Certification Mark:

• enables companies to bundle multiple certifications for multiple geographies into one single Mark

• serves as a unique identifier that provides more details on the scope of certification for a particular product

• allows for growth and inclusion of new types of certifications

As UL implements a gradual transition to the enhanced Mark, all currently existing versions of UL’s Listing and Classification Marks will remain valid and continue to be accepted as an indication of UL certification.

Example:

Classic EnhancedCertification Marks UL Certification Mark

Combined Certification for the US, Canadian and other regions

Certification attribute depending on the product and its certifications

Page 6: GLOBAL TYPE CERTIFICATION FOR SWITCHGEAR ASSEMBLIES€¦ · MV SWITCHGEAR ASSEMBLIES The term Medium Voltage refers to assemblies rated above 1kV per the scope of IEC 62271-1 and

EUROPE

DenmarkT: +45.44.85.65.65E: [email protected]

FranceT: +33.1.60.19.88.00E: [email protected]

GermanyT: +49.69.489810.0E: [email protected]

UL TTC T: +49.2151.5370.370 E: [email protected]

ItalyT: +39.039.6410.101E: [email protected]

PolandT: +48.22.336.33.39E: [email protected]

SpainT: +34.93.368.13.00E: [email protected]

SwedenT: +46.8.795.4370E: [email protected]

The NetherlandsT: +31.26.376.4800E: [email protected]

United KingdomT: +44.1483.302.130E: [email protected]

AMERICAS

ArgentinaT: +54.11.4316.8200E: [email protected]

BrazilT: +55.11.3049.8300E: [email protected]

CanadaT: +1.866.937.3ULC, 1.866.937.3852E : [email protected]

MexicoT: +52.55.3000.5400E: [email protected]

United StatesT: 877.UL.HELPS, 1.877.854.3577E : [email protected]

ASIA PACIFIC

AustraliaT: +61.1.8824.7775E: [email protected]

ChinaE: [email protected]

Guangzhou T: +86.20.3213.1000

Shanghai T: +86.21.6137.6300

Suzhou T: +86.512.6808.6400

Hong KongT: +852.2276.9898E: [email protected]

IndiaT: +91.80.4138.4400E: [email protected]

JapanE: [email protected]

Ise T:+81.596.24.8116 Tokyo T:+81.3.5293.6200 KoreaT: +82.2.2009.9100E: [email protected]

MalaysiaT: +603.5632.5922E: [email protected]

New ZealandT: +64.3.940.4400E: [email protected] SingaporeT: +65.6274.0702E: [email protected]