glaunach silencers

11
 GLAUNACH Silencer Handbook TYPES OF SILENCERS  © GLAUNACH GMBH 2005

Upload: jrri16

Post on 03-Apr-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 1/10

 

GLAUNACHSilencer Handbook

TYPES OF SILENCERS 

 © GLAUNACH GMBH 2005

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 2/10

Handbook IIPage 1 

 © GLAUNACH GMBH Edition 06-2005

ABSORBING SILENCER

type A

application - any vent or blow-down application- downstream of safety- and control valves- boiler start-up and purge- turbine bypass

media gas, air, steam,

inlet pressure atmospheric

noise reduction 25+ dB

design circular baffles reduce the noise and allow thermalexpansion of the construction. The absorber cover istotally made from stainless steel. The inlet nozzle isconnected to a diffuser pipe that redirects the gas flow.The silencer can be extended with additional absorbers toachieve a higher noise reduction.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 3/10

Handbook IIPage 2 

 © GLAUNACH GMBH Edition 06-2005

DIFFUSER SILENCER

type D

application - any vent or blow-down application- downstream of safety- and control valves- boiler start-up and purge- turbine bypass

media gas, air, steam,

inlet pressure 0,2+ bar / 3+ psi

noise reduction up to 50 dB

design several diffuser stages and a fine stainless steel wiremesh are the basic principle of diffuser silencers. Thistechnology supports a substantial smaller and lighterconstruction compared to absorbing silencers.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 4/10

Handbook IIPage 3 

 © GLAUNACH GMBH Edition 06-2005

DIFFUSER SILENCER

type DA

application - any vent or blow-down application- downstream of safety- and control valves- boiler start-up and purge- turbine bypass

media gas, air, steam,

inlet pressure 0,2+ bar / 3+ psi

noise reduction up to 50 dB

design the type DA diffuser silencer is similar to type D, exceptthat the silencer shell is equipped with an additionalinsulation. The insulation is needed for temperature andnoise control.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 5/10

Handbook IIPage 4 

 © GLAUNACH GMBH Edition 06-2005

COMBINED SILENCER (DIFFUSER + ABSORBER)

type DAA

application - any vent or blow-down application- downstream of safety- and control valves- boiler start-up and purge- turbine bypass

media gas, air, steam,

inlet pressure 0,2+ bar / 3+ psi

noise reduction 50+ dB

design the type DAA diffuser silencer is a combination of type Aand type DA silencer. With additional absorbers almostany noise reduction can be achieved.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 6/10

Handbook IIPage 5 

 © GLAUNACH GMBH Edition 06-2005

INLINE DIFFUSER SILENCER

type INLINE

application in particular for closed systems- any vent or blow-down application- condenser injection- turbine bypass

media steam, gas, air,

inlet pressure 0,2+ bar / 3+ psi

noise reduction up to 50 dB

design for noise control at pipes, we manufacture the InlineSilencer. This type is similar to the Diffuser Silencer D.Many small diffuser holes disengage the fluid into a finestainless steel wire mesh.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 7/10

Handbook IIPage 6 

 © GLAUNACH GMBH Edition 06-2005

DIFFUSER

type DUMP TUBE

application - any vent or blow-down application- downstream of safety- and control valves- condenser injection- turbine bypass- redirection of the gas flow- pressure control- temperature control

media steam, gas, air,

inlet pressure 0+ bar / 0+ psi

noise reduction up to 15 dB

design carbon or stainless steel pipes are furnished with acustomized number and size of diffuser holes.Diffuser Pipes are part of any vent silencer to obtain anoptimum noise control.However, dump tubes are also used for other purposethan noise control. Such applications can be found e.g. atby-pass systems, blow-down tanks or condensers.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 8/10

Handbook IIPage 7 

 © GLAUNACH GMBH Edition 06-2005

DIFFUSER

type DIFFUSER

application - any vent or blow-down application- downstream of safety- and control valves- condenser injection- turbine bypass- redirection of the gas flow- pressure control- temperature control

media steam, gas, air,

inlet pressure 0,2+ bar / 3+ psi

noise reduction up to 50 dB

design diffusers are used for same applications as dump tubes,but with a higher noise reduction. The fluid passesthrough several diffuser stages and through a finestainless steel wire mesh.

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 9/10

Handbook IIPage 8 

 © GLAUNACH GMBH Edition 06-2005

COLLECTING PIPE

type COLLECTING PIPE

application to connect more than two blow-off pipes into onesilencer, we recommend to use a collecting tube. Valveswith different set pressures can be combined. Thereforethe down stream pressure of all valves needs to beequated.

media steam, gas, air,

inlet pressure any

noise reduction up to 15 dB (without silencer)

design silencers equipped with collecting pipes are designed forthe maximum possible flow level

40 psi

80 psi

145 psi

80 psi

7/28/2019 Glaunach Silencers

http://slidepdf.com/reader/full/glaunach-silencers 10/10

Handbook IIPage 9 

 © GLAUNACH GMBH Edition 06-2005

RENTAL SILENCER

type DA & DAA

application - any vent or blow-down application- boiler start-up and purge- turbine bypass

with the construction of new boilers, equipment change,or repair work, debris may be introduced into the pipingsystem. This must be removed before the process gas orsteam is used. These contaminants are removed by“blowing free“ the piping. Often silencers are used thatdo not withstand the continuous stress or which become

ineffective as a result of obstructions in the diffuser.

Glaunach has developed a special Silencer which can beused repeatedly. This silencer allows the replacement ofa diffuser cartridge in the event its performance isimpeded by debris and back pressure becomes too high.

media steam, gas, air,

inlet pressure > 0,2 bar / > 3 psi

noise reduction up to 70 dB

design DA or DAA Diffuser Silencers, but with exchangeablediffuser cartridge