gkw-rw/s 300/500v thin wall multicore

4
3 TRACTION CABLES GKW-RW/S 300/500V Thin Wall Multicore º Applications Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology. º Standard BS 6853 -Ia DIN 5510-2 1-4 NFF 16-101 F0 º Construction Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295. Insulation: Electron beam crosslinkable LSZH compound. Sheath: Electron beam crosslinkable LSZH compound. º Electrical Characteristics at 20Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 Voltage Rating KV 0.3/0.5 º Mechanical and Thermal Properties Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60~+120(Static); -40~+90(Flexing) Short Circuit Temperature: +280Stranded Tinned Copper Conductor Electron Beam Crosslinkable LSZH Sheath Electron Beam Crosslinkable LSZH Insulation Caledonian Railway Cables TRACTION CABLES [email protected] [email protected]

Upload: others

Post on 19-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

3TRACTION CABLES

GKW-RW/S 300/500V Thin Wall Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation

Caledonian Railway CablesTRACTION CABLES

[email protected]@railway-cables.com

www.addison-cables.com 4

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×0.5 16/0.20 0.18 4.5 293×0.5 16/0.20 0.18 4.6 364×0.5 16/0.20 0.18 5.0 445×0.5 16/0.20 0.18 5.4 526×0.5 16/0.20 0.18 5.9 597×0.5 16/0.20 0.18 6.4 718×0.5 16/0.20 0.18 6.8 819×0.5 16/0.20 0.18 7.1 81

10×0.5 16/0.20 0.18 7.3 8812×0.5 16/0.20 0.18 7.5 10114×0.5 16/0.20 0.18 7.9 11516×0.5 16/0.20 0.18 8.3 12818×0.5 16/0.20 0.18 8.8 14419×0.5 16/0.20 0.18 8.8 14820×0.5 16/0.20 0.18 9.3 16124×0.5 16/0.20 0.18 10.2 18127×0.5 16/0.20 0.18 10.6 20036×0.5 16/0.20 0.18 11.9 26148×0.5 16/0.20 0.18 13.5 3372×0.75 24/0.20 0.18 4.8 373×0.75 24/0.20 0.18 5.1 484×0.75 24/0.20 0.18 5.6 585×0.75 24/0.20 0.18 6.1 696×0.75 24/0.20 0.18 6.7 817×0.75 24/0.20 0.18 7.1 938×0.75 24/0.20 0.18 7.7 1089×0.75 24/0.20 0.18 8.1 108

10×0.75 24/0.20 0.18 8.3 11812×0.75 24/0.20 0.18 8.6 13714×0.75 24/0.20 0.18 9.0 15616×0.75 24/0.20 0.18 9.5 17518×0.75 24/0.20 0.18 10.0 19819×0.75 24/0.20 0.18 10.1 20220×0.75 24/0.20 0.18 10.5 21924×0.75 24/0.20 0.18 11.7 24827×0.75 24/0.20 0.18 12.2 27536×0.75 24/0.20 0.18 13.7 36248×0.75 24/0.20 0.18 15.5 4682×1.0 32/0.20 0.18 5.2 453×1.0 32/0.20 0.18 5.5 594×1.0 32/0.20 0.18 6.2 73

Caledonian Railway CablesTRACTION CABLES

[email protected]@railway-cables.com

5TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

5×1.0 32/0.20 0.18 6.7 876×1.0 32/0.20 0.18 7.3 1027×1.0 32/0.20 0.18 7.9 1198×1.0 32/0.20 0.18 8.4 1359×1.0 32/0.20 0.18 8.9 137

10×1.0 32/0.20 0.18 9.1 15012×1.0 32/0.20 0.18 9.4 17414×1.0 32/0.20 0.18 9.9 19916×1.0 32/0.20 0.18 10.4 22318×1.0 32/0.20 0.18 11.0 25419×1.0 32/0.20 0.18 11.1 25920×1.0 32/0.20 0.18 11.7 28224×1.0 32/0.20 0.18 12.9 31927×1.0 32/0.20 0.18 13.4 35436×1.0 32/0.20 0.18 15.1 46748×1.0 32/0.20 0.18 17.2 6072×1.5 30/0.25 0.22 6.0 593×1.5 30/0.25 0.22 6.4 814×1.5 30/0.25 0.22 7.1 995×1.5 30/0.25 0.22 7.7 1236×1.5 30/0.25 0.22 8.5 1437×1.5 30/0.25 0.22 9.1 1638×1.5 30/0.25 0.22 9.8 1889×1.5 30/0.25 0.22 10.5 189

10×1.5 30/0.25 0.22 10.7 21512×1.5 30/0.25 0.22 11.1 24414×1.5 30/0.25 0.22 11.7 27916×1.5 30/0.25 0.22 12.3 32618×1.5 30/0.25 0.22 13.0 35819×1.5 30/0.25 0.22 13.1 36620×1.5 30/0.25 0.22 13.7 39624×1.5 30/0.25 0.22 15.3 45027×1.5 30/0.25 0.22 15.9 50136×1.5 30/0.25 0.22 17.9 66337×1.5 30/0.25 0.22 18.5 71948×1.5 30/0.25 0.22 20.5 8642×2.5 50/0.25 0.28 7.1 893×2.5 50/0.25 0.28 7.4 1174×2.5 50/0.25 0.28 8.3 1505×2.5 50/0.25 0.28 9.1 1826×2.5 50/0.25 0.28 9.9 2097×2.5 50/0.25 0.28 10.8 2468×2.5 50/0.25 0.28 11.7 2859×2.5 50/0.25 0.28 12.5 286

Caledonian Railway CablesTRACTION CABLES

[email protected]@railway-cables.com

www.addison-cables.com 6

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

10×2.5 50/0.25 0.28 12.7 31812×2.5 50/0.25 0.28 13.1 37214×2.5 50/0.25 0.28 13.9 42816×2.5 50/0.25 0.28 14.7 48318×2.5 50/0.25 0.28 15.2 53819×2.5 50/0.25 0.28 15.5 56520×2.5 50/0.25 0.28 16.4 61224×2.5 50/0.25 0.28 18.3 69527×2.5 50/0.25 0.28 18.9 77636×2.5 50/0.25 0.28 21.3 103048×2.5 50/0.25 0.28 24.5 1347

Soldering HeatResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant AbrasionResistant

Corona Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant Low TemperatureResistant

Caledonian Railway CablesTRACTION CABLES

[email protected]@railway-cables.com