GEOTECH SERVICESSoil & Materials Testing Laboratory
X-18, MIDC, Hingna Industrial Estate, Nagpur-440 016Tele-Fax : 07104-232671. 234512, 236571, 236576 E-Mail: geotechf
TEST REPORT
PageReport
Date
5satyam.net.in
1 of 6109/CMD/NOV10
16.12.2010
CUSTOMER
LETTER REF.
PROJECT
DATE OFRECEIPTSAMPLE;CONDITIONWHEN RECEIVED
DATE OF TEST
: Stdhesliwar IIPL-IGCMPL
: Nil
; NA
: 13.11.10
: Sealed
: From 13. 11. 10 onwards
ADDRESS
AGENCY
MATERIALIDENTIFICATION
SAMPLED BY
TFST1 LJ 1
PERFORMED
METHOD OFTEST
: Nagpur.
: NA
Ultratech OPCcement, 20 mmCA Natural Sandcrushed sample
: Customer
: Mix Design M25
: 15:10262-2009
5310
and
1 INTRODUCTION:
Mix design of concrete grade M25 (Pumpable and Non Pumpable) was carried out for
Sidheshwar IIPL-IGCMPL Nagpur. The material submitted for the mix includes,
Ullratech OPC 53 grade cement, 20 mm. 10 mm. coarse aggregate, Natural sand and
Crushed sand as fine aggregate.
2 MATERIAL TEST DATA
2.1 Sieve Analysis
Sieve Size
mm' 20 mm.40 10&
20 97.010.0 2.0
4.75 oJ .... __..
2.36
1.18 •0.6
0.3
0.15
Percent Passing
10 mm. Crushed Sand
100 1001 i
100 100
84.8 100i 1
9.2 100
0.3 94.7
0 61.8
31.11 ij 17.5
11.0
Fineness Modulus of Sand 3.768 jSand Conforming to Zone Zone 1
Natural Sand
100
100
100
97.S
91.1
74.2
46.7
14.2
1.5
2.742
Zone [I
Report NoDale
2 of 6109/CMD/NOV10
16.122010
2.2 Other Properties
a.
b.
c.
Properties Natural Sand
Specific Gravity
Water absorption
2.62
1.4%
Surface moisture NIL
Crushed Sand
2.72
2.2%
NIL
Coarse aggregate
2.83
1 .2 %
NIL
2.3 Tests on Cement
Consistency
Specific Gravity
28.0 %
I 3.087 "
Initial Setting time
Final Setting time
Soundness by Le'Chattelier Expansion
200 min
255 min
0.45 mm
Fineness by Blains Air Permeability 339 sq.m/kg.
| 3 Days Compressive Strength
; 7 Days Compressive Strength
; 28 Days Compressive Strength
39.0 Mpa
T"43.0Mpa1 64.0 Mpa
3. MIX DESIGN
3.1 Design Stipulations
Following design stipulations are considered based on the site conditions and requirements of
IS: 456-2000.
Properties
Type of concrete
Degree of exposure
Degree of quality control
Degree of Workability
Maximum size of aggregate
Maximum Water Cement Ratio
Minimum cement content
Retention
M 25 Non Pumpable
RCC
Moderate
Good
0.85 Compaction factor
20mm
0.5
300Kg/cu.m
NA
M25 Pumpable
RCC
Moderate
Good
0.95 Compaction factor
20 mm
0.5
300Kg/cu.m
15 Minutes
Page 3 of 6Report No 109/CMD/NOV10
Date 16.12.2010
3.2 Target Mean Strength (ft)
The target mean strength is given as
ft = fck + K.S
fck = Characteristic strength required
K = A statistical value based on accepted proportion of
Lower test results and number of test
1.65 for 5 % tests results below fck.
S = Standard deviation taken as 4
Hence ft = 31.6Mpafor M25
3.3 Mix Trial as per 18:10262 - 2009
The initial trial was carried out on mix designed as per IS: 10262-2009 (Enclosed in
appendix for M25 Non-Pumpable with crushed sand).
Cement Content : 326.0 Kg/cu.m.
Water Content : 162.9 Kg/cu.m.
C.Aggregates Content : 1240.0 Kg/cu.m.
Sand Content : 794.0 Kg/cu.m.
Admixture Content : 1.63 Kg/cu.m.
THEOROTICAL YIELD : 2525 Kg/cu.m.
The mix prepared as per IS: 10262 indicated satisfactory workability. Sand content in
mix is slightly higher (40.0 %) indicating high fines in concrete.
Since, 20 mm. aggregates are slightly oversized, instead of grading the aggregates to
meet IS:383 requirements, mixes were prepared with varying proportion of sand and
CA to produce cohesive and workable mix. The proportion finalised are as under:-
• For Non Pumpable Concrete 75 : 25 (20 mm: 10 mm) with 35% fine aggregate.
• For Pumpable Concrete 60 : 40 (20 mm : 10 mm) with 40% fine aggregate .
During trials Plasticizer SP-430 G8 were used to maintain the workability.
Page 6 of 6Report No 109/CMD/NOV10
Date 16.122010
4.2 The grading of the aggregates shall be checked regularly & should match the
grading of aggregate received in the laboratory as this may have an effect on the strength &
other characteristic of the concrete. For sand, the gradation shall be strictly maintained -
because any major variation, particularly on 600 n sieve can affect the strength of concrete.
4.3 The above water content is recommended considering dry aggregate, as such
correction for absorption is made. In order to maintain workability, proportionate
adjustment as above (water absorption), in the quantity of water shall be made, if the
aggregate received are wet.
4.4 The plasticizer used shall be SP-430 G8 of Fosroc Chemicals only. In case of
other Brand or Make of admixture. 28 days strength shall be ensured.
For GEOtECH SERVICES,
Sudhlr liadkjjedkarG.M.(Tech-)
• The above results ate related only in the sample tested in this laboratory.• No report shall be reproduced, except in fall, without written approval of this laboratory.• Any query about report may be reported immediately, sample will he preserved for 91) days
4 of 6Report No I09/CMD/NOV10
Date 16.12.2010
3.4 TRIALS
Considering all above points, proportions of aggregates etc. trials are taken with
varying cement contents. The summary of main trials are given below -
Properties
Mix Proportion
Water Cement Ratio
Cement Content
Sand Content
Admixture
Slump Observed (Initial)
Slump after 15 min
7 Days Strength Mpa
28 Days strength Mpa
Properties
Mix Proportion
Water Cement Ratio
Cement Content
Sand Content
Admixture
Slump Observed
7 Days Strength Mpa
28 Days strength Mpa
Pumpable
With 100% crushed sand
Mix 1 Mix 2
1 :2J2 :3.48 1 : 2.44: 3.67
0.48 0.50i
340 kg/cu.m. 325 kg/cam.
40% 40%
@ 0.8 % @ 0.8 %
140mm. 130mm.
120mm. 110mm.
22.6 17.4
35.7 32.7
Non Pumpable
With 100% crushed sand
Mix 5 Mix 6
1 : 2.12: 3.94 1 : 2.23 : 4.15
0.47 0.50
340 kg/cu.m. 325 kg/cu.m.
35% 35%
@0.5% @0.5%
70 mm. 65 mm.
23.5 20.4
35.4 33.0
With 50% crushed sand +! 50% Natural sand
Mix 3 Mix 5
1 :2.32 :3.48 1 : 2.44: 3.67| 1
0.48 0.501
= ' 1 ' — — — — — —-
340 kg/cu.m. i 325 kg/cu.m.
40% 40%i [@ 0.8 % @ 0.8 %
] i130mm. 140mm.
1 !1 10 mm. 100mm.
21.6 19.2
34.6 31.8
With 50% crushed sand +' 50% Natural sand
Mix 7 Mix 8! :1 : 2.12: 3.94 1 : 2.23: 4. 15
|
0.47 0.50! 1
340 kg/cu.m. 325 kg/cu.m.
35% 35%i
@ 0.5% @ 0.5%
65 mm. 70 mm.
25.7 21.3i i
38.2 32.1
Based on above results following mix is recommended.
A P P E N D I X
CONCRETE MIX DESIGN15:10262-2009
Material Code 109/CMD/KOV10
A. DESIGN STIPULATIONS
1. Concrete Grade
2. Characteristic Strength Required at 28 Days at Site
3. Maximum Size Of Aggregate
4. Degree Of Quality Control
5. Degree Of Exposure
6. Type of concrete
7. Desired Slump
8. Minimum Cement Content
9. Maximum Water Cement Ratio
10. Specifications to be followed
11. Flyash to be used,.?
13. If admixture is to be used...?
14. Type of Admixture
M 25
25
20
Mpa
mm.
Good
about
Moderate
RCC
50 mm.
300 kg/cu.m.
0.5
IS
No
Yes
Plasticizer
B. TEST DATA OF MATERIAL
Cement Used
Type of Cement
Specific Gravity Of Cement (Gcem)
Specific Gravity Of Sand (Gs)
Specific Gravity Of Aggregates (Gm)
Water Absorption Of sand
Water Absorption Of Coarse Aggregates
Sand Conforms to Grading Zone
Brand
Relative Density Of Admixture
Ultratech
OPC 53
3.087
_2.72_
2.83
2.2
1.2
SP-430 G8
1.23
C. TARGET MEAN STRENGTHft = fck + K S
Ft = 25 + 1.65 x 4.0 31.6 Mpa
D. Water Cement Ratio
Let's start with maximum water cement ratio. The WCR utilised in the desigh -will be : 0.50(Ref- as per clause 4.1 of IS-10262-2009)
E. Water Content
As per table 2 of IS: 10262-2009, the water content for 2 0 MSA is 186 Kg/cu.m.This water content corresponds to a slump of 25-50 mm. For each 25 mm. increase or decrease in slumpincrease or decrease water content hy 3 %. Hence for a required smump of 50 mm. the changedwater content shall be 191.6 kg/cu.m.
Since, admixture is proposed to be used, reduction in water requirement is to be made
Type of admixture: Plasticizer % "Water reduction: 15 (Bsed on experience
Corrected water content 162 . 9 Kg/cu.m. with this type of admixture)
Note : Dosage of admixture is maintained as 0.5 % By weight of cementatious content
F. Cement Content
Water cement ratio : 0.50 Water content: 162.9 Kg/cu.m.
Hence, the cement content will be 162.9 / 0.50 326 kg/cu.m.
This cement content is more than minimum cement content, hence OK
The cement content used in the design will be 32 6 kg/cu.m.
G. Coarse Aggregates Content
Sand conforming to grading zone : I
As per table 3 of 15:10262-09, for this sand zone and maximum aggregate size 20 mm.
Volume of coarse aggregates per unit volume of total aggregate is 0 . 60
Hence, the unit CA content by vol. in the design wi l l be 0 . 60
H. Mix Calculations
The mix calculations per unit volume of concrete shall be as follows -
a. Volume of concrete : 1 cu.m.
b. Volumen of cement: 1/1000 x (Mass of Cement/ Specific gravity Of Cement)326 / 3.087 x 1/1000 0.1056 cu.m.
c Volume of Flyash : f/1000 x (Mass of Flyash / Specific gravity Of Flyash)NA /
d. Volume of Admixture 1/1000 x (% Dosage x cementatious content /Relative density of admixture)326 x 0.005 / 1.23 x 1/JOOO
0.0013 cu.m.
e. Volume of water 1/1000 x (Mass of Water/ Specific gravity Of Water)162.9 / 1 x 1/1000 0.1629 cu.m.
f. Vol.of Total Aggregates = 1 -(b + c + d + e)1.0000
= 1 - [ 0.106 + 0.0000 + 0.0013 + 0.1629 ]
0.7302 cu.m.
g. Mass of CA -f x Vol ofCA per unit Vol of total aggregates x Spc.Gr of CA x 10000.7302 x 0.60 x 2.83 x 1000
1240 Kg/cu.m.
h Mass of FA = f x( l - Vot of CA per unit Vol of total aggregates) x. Spc.Gr of FA x 10000.7302 0.40 2.720 x 1000
794 Kg/cu.m.
I Mix Proportion Balch for Trial 1
Cemementatious content
Cement Content
Flyash Content
Water Content
C.Aggregates Content
Sand Content
Admixture Content
THEOROTICAL YIELD
326.0 Kg/cu.m.326.0 Kg/cu.m.
0 Kg/cu.m.
162 .9 Kg/cu.m.
1240.0 Kg/cu.m.
794 .0 Kg/cu.m.
1.63 Kg/cu.m.
2525 Kg/cu.m.
PageReport No
Date
5 of 6109/CMD/NOV10
16.12.2010
RECOMMENDATIONS
4.1 Following mix is recommended for concreting
For Pum panic Concrete:
Properties1
Mix Proportion
Water Cement Ratio
Cement Content
Crushed Sand Content
Natural Sand Content
Admixture SP-430 G8 @ 0.8%
Coarse Aggregates 20 mm @60%
Coarse Aggregates 10 mm @40%
Water Content (W,rt.WC Ratio)
Water Absorption of coarse aggregate @ 1 .2 % ;
Water Absorption of crushed sand @ 2.2 %
Water Absorption of natural sand @ 1.4 %
Total Water Content
M25 with crushed
1 : 2.44 : 3.67
0.50
325 kg/cu.m.
793 kg/cu.m.
NA
2.6 Kg/cu.m.
715Kg/cu.m.
477 Kg/cu.m.
162.5 Lit /cu.m.
14.3 Lit /cu.m
17.4 Lit /cu.m
NA
194.2 Lit /cu.m
M25 with crushed sand+natural sand1 : 2.44 : 3.67
i
0.50
325 kg/cu.m.
396 kg/cu.m.
396 Kg / cu.m
2.6 Kg /cu.m.
715Kg/cu.m.
477 Kg / cu.m.'
162.5 Lit /cu.m.
14.3 Lit /cu.m
8.7 Lit /cu.mi
5.5 Kg/cu.m
191.0 Lit/ciun
For Non Pumpable Concrete:
Properties
Mix Proportion
Water Cement Ratio
Cement Content
Crushed Sand Content
Natural Sand Content
Admixture SP-430 G8 @ 0.8%
Coarse Aggregates 20 mm @75%
Coarse Aggregates 10 mm @25%
Water Content (W.rt.WC Ratio)
Water Absorption of coarse aggregate @ 1 .2 %
Water Absorption of crushed sand @ 2.2%
Water Absorption of natural sand @ 1.4 %
Total Water Content
M25 with crushed
1 : 2.23: 4. 15
0.50
325 kg/cu.m.
725 kg/cu.m.
NA
2.6Kg/cu.m.
944 Kg/cu.m.
337Kg/cu.m.
162.5 Lit /cu.m.
16.1 Lit/cu.m
15.9 Lit /cu.m
NA
194.5 Li t /cu.m
M25 with crushed sand+natural sand1 : 2.23: 4. 15
0.50
325 kg/cu.m.
362 kg/cu.m.
362 Kg/cu.m
2.6 Kg / cu.m.
944Kg/cu.rn.
337 Kg /cu.m.
162. 5 Lit/cu.m.
16.1 Lit/cu.m
7.9 Lit / cu.m
5.0Kg/cu.m
191. 5 Lit /cu.m