general objective: conduct r&d activities to improve the quality of sst products used by mersea...

23
General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic and Mediterranean Sea analyzed SST fields needed for MERSEA regional and global models CNR contribution to MERSEA SST activities (Task 2.2)

Upload: tyrone-gallagher

Post on 19-Jan-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic and Mediterranean Sea analyzed SST fields needed for MERSEA regional and global models

CNR contribution to MERSEA SST activities(Task 2.2)

Page 2: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

CNR work in particular concerns:

•Inter-comparison and validation of MEDSPIRATION L4 and MFSTEP SST products.

•Improvement of techniques to merge infrared sensors in the Mediterranean Sea.

Run MFS L4_processor only with L2PConfigure Medspiration L4_processor – identify possible evolutions/bugs in the code

•Continuation of the production of MFSTEP analyses (after the end of MFSTEP).

EXPECTED DELIVERABLES:

Month 20:Report on the inter-comparison of MEDSPIRATION and MFSTEP SST analyses over the Mediterranean Sea.Month 30:Report on the merging of AVHRR, AATSR and MODIS (from TERRA and AQUA) SST products in the Mediterranean Sea

Page 3: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

Results already described at Brest meeting:

Could Medspiration L4 sub-sampled over MFS grid be used in the assimilation? not with present configuration

Could the present MFS analysis be improved by including Medspiration L2P data? Yes. possibly to be implemented operationally

What was left:

Can MFS L4 be run only with Medspiration L2P?

Can the Medspiration L4 software be run to interpolate directly on MFS model grid, with stable results, possibly improving MFS?

Page 4: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

Period examined: jan-oct 2005

Methods:Evaluation of processor performance: -qualitative

-quantitative

Comparison of SST L4 against quality controlled in situ XBT data acquired within MFSTEP

Test performed:MFS at 1/16° AVHRR by CNR+CMS

merging MFS data and SEVIRI/AATSR L2P only L2P (all infrared)

original configuration

Medspiration L4 at 2 km resampled at 1/16° L2Poriginal configuration

Medspiration L4 at 1/16° (hereafter MERSEA L4) L2Pdifferent configurations starting from parameters similar to MFS ones

Page 5: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

REMARKS:

• MFS and CLS processors have different data editing and selection criteria/strategies

-bias between sensors-selection of valid input (confidence values, clouds)-selection of influential observations within the bubble

• but the different OI configurations can be tuned to have- similar spatial and temporal influential radius (‘bubble’)…- same correlation function- same grid/resolution

Page 6: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFSTEP –spatial distribution of XBT measurements

Evaluation of SENSOR BIASES

needed to choose a reference sensor for data merging with MFS processor

impact on quality of MERSEA L4

Page 7: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

Evaluation of SENSOR BIASES: results

Page 8: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

L

rt

eetrC

),(L =180 kmτ =7 days

MERSEA:SELMS_LIST > NAR17_SST AVHRR17_L NAR16_SST AVHRR16_LX_BUL_RATIO=2.0Y_BUL_RATIO=2.0T_BUL_RATIO=1.0OAN_KEEP_ALL_MEAS = 0# For each sensor, in each cell of the collated file, only the nearest # measurement to the processing date is kept. There is only one # observation file created per sensor.## OAN_KEEP_ALL_MEAS = 1# For each sensor, in each cell of the collated file, the whole # measurements are kept. There is one observation file per sensor and# per days created.

MFS:Reference sensor priority: AATSR NAR17 AVHRR17_L SEVIRI NAR16 AVHRR16_L

DIST=200 starting spatial influential radius for data selection.RMAXDIST=600 maximum spatial influential radius for data selection (the influential radius is incremented if data selected within DIST are less then LIMIT).

NPIX=3 number of values selected in time for each pixel.

Medspiration results:

Page 9: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS and Medspiration L4 original configuration

MFS (only AVHRR) MEDSPIRATION L4 subsampled at 1/16°

Page 10: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS with new INPUT data

MFS (MFS+infrared L2P) MFS (infrared L2P only)

Page 11: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MERSEA L4 (CLS processor with new configuration)

MERSEA (no bias) MERSEA (bias correction)

Page 12: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS with new INPUT data

Page 13: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS and Medspiration L4 original configuration

Page 14: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MERSEA L4 (CLS processor with new configuration)

Page 15: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS and MERSEA new L4 configuration

Page 16: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS and Medspiration L4 original configuration

Page 17: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS with new INPUT data

Page 18: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MERSEA L4 (CLS processor with new configuration)

Page 19: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

MFS and MERSEA new L4 configuration

Page 20: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

No bias correction

Bias correction applied

Impact of bias correction

on MERSEA L4

Page 21: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

(A1d) bias, OAN_KEEP_ALL_MEAS=1

(A2e) bias, OAN_KEEP_ALL_MEAS=0

Impact of the number of observations per sensor

Page 22: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

Bugs in the L4 processor code and suggested evolution• when using data from a temporal window larger then 1 day, a

different first guess (climatology file) is used for each input file. same first guess should be subtracted from each of the observations within the influential bubble

SOLVED BY CLS but we don’t have the new code!

• parameter AB_CEIL and corresponding check on maximum allowed correlation between observations and interpolation points have no sense. Observation sub-sampling should be performed selecting only data that are not too much cross correlated. Correlation between observations and interpolation point must be high…

• One possible evolution # OAN_KEEP_ALL_MEAS = N# For each sensor, in each cell of the collated file, only the first N nearest in time# measurements are kept. There is one observation file per sensor and# per days created????

• other possible evolution: data reduction strategy?

Page 23: General Objective: Conduct R&D activities to improve the quality of SST products used by MERSEA modeling and assimilation centers and produce global, Atlantic

CONCLUSIONS

Could Medspiration L4 sub-sampled over MFS grid be used in the assimilation? not with present configuration

Could the present MFS analysis be improved by including Medspiration L2P data? Yes, already done, possibly to be implemented operationally

Can it be run only with Medspiration L2P? Yes, already done, possibly to be implemented operationally

Can the Medspiration L4 software be run to interpolate directly on the model grid, with stable results, possibly improving MFS? Possibly yes, but more work has to be done (understand biases, reduce computation time)