general notes innisdale secondary school site works … · 2020-03-02 · the certificate of...

6
DN UP UP DN DN Name of Project: Building Code Data Matrix Parts 3 or 9, January 2017 [re-creation]. For Additional Floors, go to Page 2 2nd Floor: Basement: 1st Floor: Occupancy Occupancy Occupancy persons persons persons Load Load Load New New 2012 Ontario Building Code Data Matrix Parts 3 or 9 5 Number of Storeys Above Grade 13 15 16 12 11 10 9 7 8 6 Water Service / Supply is Adequate Construction Restrictions Actual Construction Mezzanine(s) Area [m²] Occupant Load Based on Standpipe Required Fire Alarm Required High Building Combustible permitted Combustible m² / person Number of Streets / Fire Fighter Access Building Classification Sprinkler System Proposed 3 4 2 1 Item Major Occupancy(s) Building Area [m²] Gross Area [m²] Project Type: Existing Existing Location: 1.4.1.2.(A)&9.10.4 Below Grade 1.4.1.2.(A) & 3.2.1.1 3.2.2.10 & 3.2.5 3.2.1.1.(3) - (8) Non-combustible required Non-combustible design of building Yes Yes Yes Yes No No No No 3.2.2.20 - .83 Both 3.1.17 3.2.6 3.2.9 3.2.4 Basement In lieu of roof rating Not required Selected floor areas Entire building Selected compartments INDEX 3.2.2.17 3.2.2.20 - .83 3.2.1.5 3.2.2.20 - .83 9.10.18 9.10.4.1 9.10.6 N/A N / A N / A N / A 9.10.20 9.10.8.2.-4. 9.10.2 The architect noted above has exercised responsible control with respect to design activities. The architect's seal number is the architect's BCDN References are to Division B unless noted (A) for Division A or (C) for Division C. Part 11 11.1 to 11.5 Total Total Addition New 1.4.1.2.(A) 1.4.1.2.(A) 3.1.2.1.(1) 1.1.2.(A) Part 3 Part 9 1.1.2.(A) 1.4.1.2.(A) 1.4.1.2.(A) 9.10.2 OBC Reference Ted Handy and Associates Inc., Architect 76 Mary Street Barrie, Ontario Certificate of Practice Number: The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary School Renovation Group A Div. 2 95 Little Avenue. Barrie, ON. L4N 2Z4 2 N/A 3.2.2.24 2 10,418 16,742 - - - - - 14 Importance Category Low human occupancy Normal 4.1.2.1.(3) & T4.1.2.1.B [A] 1.1.2.2.(2) Low Post- disaster shelter Site Class (A,B,C,D,E from Geotechnical Report) 4.1.8.4. 4.1.8.4. Seismic Hazard Index 4.1.2.1.(3) 4.1.8.18.(1) I E Fa Sa (0.2) = Design for Seismic Required for items 6 to 21. Table 4.1.8.18. (Equal or Above 0.35?) (Yes or No) 4.1.8.18.(2) 4.1.8.18.(2), 9.20.1.2., 9.31.6.2.(3) p. 1 of 2 Change of use Alteration Description: Use School Washroom & Parking Lot Repairs N / A Heavy Timber Construction Yes No 3.2.1.4. High Minor storage building Explosive or hazardous substances Post-disaster A2 927 A2 927 Refer to Key Plan for sprinklered areas Mezz.: Occupancy persons Load N/A N/A N/A N/A 123 159 155 C108 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 AREA 1a - 1977 CONSTRUCTION - TWO STOREY (A2) SPRINKLERED, NON-COMBUSTABLE, 1 HOUR FLOOR RATING AREA 2 - 1998 CONSTRUCTION (A1) SPRINKLERED, NON-COMBUSTABLE, 1 HOUR FLOOR RATING AREA 1b - 1977 CONSTRUCTION - ONE STOREY (A2) PORTION OF BUILDING NOT SPRINKLERED, NON-COMBUSTABLE, 125 Building Code Data Matrix Parts 3 or 9, January 2017 [re-creation]. p. 2 of 2 3.2.3 3.2.3 20 (Spatial Separation - Construction of Exterior Walls - Continued) Permitted Max. % of Openings Area of EBF [m²] Wall L / H or H / L L.D. [m] Floor Floor Occupancy Occupancy Proposed Max. % of Openings Listed Design or Description FRR [hours] Load Load persons persons hours hours hours Permitted Max. % of Openings South For Additional Wall, see below 16 (Occupant Load - Continued) 22 Floor Floor West East Occupancy Occupancy Area of EBF [m²] Spatial Separation - Construction of Exterior Walls 20 Wall North L / H or H / L L.D. [m] Roof Mezzanine Floors Load Load persons persons Proposed Max. % of Openings Listed Design or Description FRR [hours] Comb. Const., Non-comb. Cladding Comb. Const. Non-comb. Const. 9.10.14 Comb. Const., Non-comb. Cladding Comb. Const. 9.10.14, 9.10.15 Non-comb. Const. 3.2.2.20 - .83 & 3.2.1.4 hours hours hours FRR of Supporting Members Horizontal Assemblies FRR [hours] Resistance [ FRR ] Rating Required 19 Fire Floors Mezzanine Roof Non-combustible in lieu of rating? 9.10.8 1 Plumbing Fixture Requirements 21 Building Code Reference Part 3 Part 9 Occupant Load OBC Table Number Fixture Required Fixtures Provided Male/ Female Count @ % / %, except as noted otherwise Basement: Occupancy Occupancy 1st Floor: 2nd Floor: Occupancy Occupancy Occupancy Occupancy No (Explain) 18 17 Barrier-free Design Hazardous Substances Yes Yes No 3.3.1.2 & 3.3.1.19 3.8 9.10.1.3 9.5.2 hours Floors over basement N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A 3.7.4 Other (Describe) 9.31 & 3.7.4 N/A N/A 1 N/A N/A FSND FEMININE SANITARY NAPKIN DISPOSAL BIN * PTD PAPER TOWEL DISPENSER HD HAND DRYER FND FEMININE NAPKIN DISPENSER * FND HD / PTD TTD FSND T/O FIN. FLR. MIRROR TTD TOILET TISSUE DISPENSER * CH CH COAT HOOK FD FLOOR DRAIN URINAL LAVATORY SD SOAP DISPENSER * OR AS INDICATED 600 840 900 900 1200 1200 600 700 LOCATED BELOW GRAB BAR 1100 WR * INDICATES OWNER SUPPIED ITEM 1000 SD LOCATED WITHIN 610mm OF LAVITORY LOCATED WITHIN 500mm OF LAVITORY 35mm dia. 'L' SHAPE GRAB BAR 600mm LONG GRAB BAR WITH PADDED BACK REST COAT HOOK TTD 150 300 max MIN 600 1200 max 840 750 750 750 430min - 485max A1.0 COVER PAGE A1.1 SITE PLAN A2.1 MAIN FLOOR A2.2 SECOND FLOOR A2.3 MAIN FLOOR WASHROOMS - WEST A2.4 SECOND FLOOR WASHROOMS - WEST SG - 1 GRADING PLAN M1.1 KEY PLAN, LEGEND, SCHEDULES , & WEST WASHROOMS - DEMOLITION AND RENOVATION M1.2 WEST WASHROOMS - DEMOLITION AND RENOVATION & PART "C" RENOVATION E1.1 SITE PLAN AND LEGEND E2.1 KEY PLAN AND DETAILS E3.1 MAIN FLOOR WASHROOM DEMOLITION & RENOVATION E3.2 SECOND FLOOR WASHROOM DEMOLITION AND RENOVATION E4.1 SPECIFICATION AND SCHEDULE DRAWING LIST CONTACT LIST: ARCHITECTURAL Ted Handy and Associates Inc. 76 Mary Street Barrie, ON L4N 1T1 t: 705 - 734 - 3580 CIVIL Pearson Engineering Ltd. 48 Alliance Blvd, Suite B7 Barrie, ON L4N 5K3 t: 705 - 719 - 4785 MECHANICAL/ELECTRICAL DEI Consulting Engineers 55 Northland Road Waterloo, ON N2V 1Y8 t: 519 - 725 - 3555 Scale Project number Date Drawn by Checked by 705 721 0265 705 734 3580 Fax Tel. L4N 1T1 Barrie, Ont 76 Mary Street TED HANDY ASSOCIATES and ARCHITECT Inc. GENERAL NOTES ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY. ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK. As indicated 2020-02-28 9:59:58 AM A1.0 Cover Page 1917 Innisdale SS Renovation 95 Little Avenue Barrie, ON. August 9, 2019 EM EPH INNISDALE SECONDARY SCHOOL SITE WORKS AND INTERIOR RENOVATION 1 : 500 Key Plan 1 1 : 20 WC - Typ. Washroom Acc. 2 1 : 16 WC - Typ. BF Stall Elevation 3 TENDER 12308T No. Description Date 1 Issued for Tender March 2, 2020

Upload: others

Post on 16-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

DN

UP

UP

DN

DN

Name of Project:

Building Code Data Matrix Parts 3 or 9, January 2017 [re-creation].

For Additional Floors, go to Page 2

2nd Floor:

Basement:

1st Floor:

Occupancy

Occupancy

Occupancy

persons

persons

persons

Load

Load

Load

New

New

2012 Ontario Building Code Data Matrix Parts 3 or 9

5 Number of Storeys Above Grade

13

15

16

12

11

10

9

7

8

6

Water Service / Supply is Adequate

Construction Restrictions

Actual Construction

Mezzanine(s) Area [m²]

Occupant Load Based on

Standpipe Required

Fire Alarm Required

High Building

Combustible permitted

Combustible

m² / person

Number of Streets / Fire Fighter Access

Building Classification

Sprinkler System Proposed

3

4

2

1

Item

Major Occupancy(s)

Building Area [m²]

Gross Area [m²]

Project Type:

Existing

Existing

Location:

1.4.1.2.(A)&9.10.4Below Grade 1.4.1.2.(A) & 3.2.1.1

3.2.2.10 & 3.2.5

3.2.1.1.(3) - (8)

Non-combustible required

Non-combustible

design of building

Yes

Yes

Yes

Yes

No

No

No

No

3.2.2.20 - .83

Both

3.1.17

3.2.6

3.2.9

3.2.4

Basement

In lieu of roof rating

Not required

Selected floor areas

Entire building

Selected compartments

INDEX

3.2.2.17

3.2.2.20 - .83

3.2.1.5

3.2.2.20 - .83

9.10.18

9.10.4.1

9.10.6

N/A

N / A

N / A

N / A

9.10.20

9.10.8.2.-4.

9.10.2

The architect noted above has exercised responsible control with respect to design activities. The

architect's seal number is the architect's BCDN

References are to Division B unless noted (A) for Division A or (C) for Division C.

Part 11

11.1 to 11.5

Total

Total

Addition

New

1.4.1.2.(A)

1.4.1.2.(A)

3.1.2.1.(1)

1.1.2.(A)

Part 3 Part 9

1.1.2.(A)

1.4.1.2.(A)

1.4.1.2.(A)

9.10.2

OBC Reference

Ted Handy and Associates Inc., Architect76 Mary StreetBarrie, Ontario

Certificate of Practice Number:The Certificate of Practice Numberof the holder is the holder's BCDN.

Name of Practice:

2481

Innisdale Secondary School Renovation

Group A Div. 2

95 Little Avenue. Barrie, ON. L4N 2Z4

2

N/A

3.2.2.24

2

10,418

16,742

-

-

-

-

-

14 Importance Category Low human occupancy

Normal

4.1.2.1.(3) & T4.1.2.1.B

[A] 1.1.2.2.(2)Low Post- disastershelter

Site Class (A,B,C,D,E from Geotechnical Report) 4.1.8.4. 4.1.8.4.

Seismic Hazard Index 4.1.2.1.(3) 4.1.8.18.(1)IE Fa Sa (0.2) =

Design for Seismic Required for items 6 to 21. Table 4.1.8.18. (Equal or Above 0.35?) (Yes or No)

4.1.8.18.(2) 4.1.8.18.(2), 9.20.1.2., 9.31.6.2.(3)

p. 1 of 2

Change of use

Alteration

Description:

Use School

Washroom & Parking Lot Repairs

N / A

Heavy Timber Construction Yes No

3.2.1.4.

High

Minor storage building Explosive or hazardous substances

Post-disaster

A2 927

A2 927

Refer to Key Plan for sprinklered areas

Mezz.: Occupancy personsLoad

N/A N/A

N/A N/A

123

159

155

C108E1

E2

E3

E4

E5E6E7E8

E9

E10

E11

E12

E13

AREA 1a - 1977 CONSTRUCTION - TWO STOREY (A2)SPRINKLERED, NON-COMBUSTABLE, 1 HOUR FLOORRATING

AREA 2 - 1998 CONSTRUCTION (A1)SPRINKLERED, NON-COMBUSTABLE, 1 HOURFLOOR RATING

AREA 1b - 1977 CONSTRUCTION - ONESTOREY (A2) PORTION OF BUILDING NOTSPRINKLERED, NON-COMBUSTABLE,

125

Building Code Data Matrix Parts 3 or 9, January 2017 [re-creation]. p. 2 of 2

3.2.3

3.2.320 (Spatial Separation - Construction of Exterior Walls - Continued)

Permitted Max. % of Openings

Area of EBF [m²]

Wall L / H or H / L

L.D. [m]

Floor

Floor

Occupancy

Occupancy

Proposed Max. % of Openings

Listed Design or Description

FRR [hours]

Load

Load persons

persons

hours

hours

hours

Permitted Max.

% of Openings

South

For Additional Wall, see below

16 (Occupant Load - Continued)

22

Floor

Floor

West

East

Occupancy

Occupancy

Area of

EBF [m²]

Spatial Separation - Construction of Exterior Walls20

Wall

North

L / H

or H / L

L.D. [m]

Roof

Mezzanine

Floors

Load

Load

persons

persons

Proposed Max.

% of Openings

Listed Design

or Description

FRR [hours]

Comb. Const., Non-comb. Cladding

Comb. Const.

Non-comb. Const.

9.10.14

Comb. Const.,

Non-comb.

Cladding

Comb. Const.

9.10.14, 9.10.15

Non-comb. Const.

3.2.2.20 - .83 & 3.2.1.4

hours

hours

hours

FRR of Supporting Members

Horizontal Assemblies FRR [hours]

Resistance

[ FRR ]

Rating

Required19

Fire

Floors

Mezzanine

Roof

Non-combustible in lieu of rating? 9.10.8

1

Plumbing Fixture Requirements21

Building Code Reference

Part 3 Part 9

Occupant Load

OBC Table Number

Fixture Required

Fixtures Provided

Male/ Female Count @ % / %,

except as noted otherwise

Basement:

Occupancy

Occupancy

1st Floor:

2nd Floor:

Occupancy

Occupancy

Occupancy

Occupancy

No (Explain)

18

17 Barrier-free Design

Hazardous Substances Yes

Yes

No 3.3.1.2 & 3.3.1.19

3.8

9.10.1.3

9.5.2

hoursFloors over basement N/A Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

3.7.4

Other (Describe)

9.31 & 3.7.4

N/A

N/A

1

N/A

N/A

FSND FEMININE SANITARY NAPKIN DISPOSAL BIN *

PTD PAPER TOWEL DISPENSER

HD HAND DRYER

FND FEMININE NAPKIN DISPENSER *

FND

HD / PTD

TTD FSND

T/O FIN. FLR.

MIRROR

TTD TOILET TISSUE DISPENSER *

CH

CH COAT HOOK

FD FLOOR DRAIN

URINAL LAVATORY

SD SOAP DISPENSER *

OR

AS

IN

DIC

AT

ED

600

840

900

900

1200

1200

600 700

LOCATED BELOW GRAB BAR

1100

WR

* INDICATES OWNER SUPPIED ITEM

1000

SD

LOCATED WITHIN 610mm OF LAVITORY

LOCATED WITHIN 500mm OF LAVITORY

35mm dia. 'L' SHAPE GRAB BAR

600mm LONG GRAB BAR WITH PADDED BACK REST

COAT HOOK

TTD

150

300 max

MIN

600

12

00

ma

x

840

750

750

750

43

0m

in -

48

5m

ax

A1.0 COVER PAGE

A1.1 SITE PLAN

A2.1 MAIN FLOOR

A2.2 SECOND FLOOR

A2.3 MAIN FLOOR WASHROOMS - WEST

A2.4 SECOND FLOOR WASHROOMS - WEST

SG -1 GRADING PLAN

M1.1 KEY PLAN, LEGEND, SCHEDULES , & WEST WASHROOMS - DEMOLITION AND RENOVATION

M1.2 WEST WASHROOMS - DEMOLITION AND RENOVATION & PART "C" RENOVATION

E1.1 SITE PLAN AND LEGEND

E2.1 KEY PLAN AND DETAILS

E3.1 MAIN FLOOR WASHROOM DEMOLITION & RENOVATION

E3.2 SECOND FLOOR WASHROOM DEMOLITION AND RENOVATION

E4.1 SPECIFICATION AND SCHEDULE

DRAWING LIST

CONTACT LIST:

ARCHITECTURALTed Handy and Associates Inc.76 Mary StreetBarrie, ON L4N 1T1t: 705-734-3580

CIVILPearson Engineering Ltd.48 Alliance Blvd, Suite B7Barrie, ON L4N 5K3t: 705-719-4785

MECHANICAL/ELECTRICALDEI Consulting Engineers 55 Northland RoadWaterloo, ON N2V 1Y8t: 519-725-3555

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

As indicated

20

20

-02

-28 9

:59

:58

AM

A1.0

Cover Page

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

INNISDALE SECONDARY SCHOOLSITE WORKS AND INTERIOR RENOVATION

1 : 500

Key Plan1

1 : 20

WC - Typ. Washroom Acc.2

1 : 16

WC - Typ. BF Stall Elevation3

TENDER 12308T

No. Description Date

1 Issued for Tender March 2, 2020

Page 2: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

DNDN

P1047 P1032 P948

P1038 P1029 P749

P928 P871 P841

P858 P859 P703 P736 P862 P957 P863 P857 P755 P860

428

146

20

13

CB

59

58162

G GR R

MHMH

MHMH

CB

FHHB

CB

MHMH

243218217192

HB

SB

UP

UP

UP

CB

CB

6

UP

LITTLE AVENUE

BA

YV

IEW

AV

EN

UE

SP

G

FH

CB

FH

ALLANDALE RECREATION

CENTRE

P833 P1701

1

721

102 103

173

180

174

181

191

204 205 231 231

269244

256 257

270

282

283

298

299

303

304

320

321

339

340

351

410

398

409

385

397

375

377

378

384

374

372

371

365

352

364

LAY-BY LANE AND SIDEWALK FOR DROP OFFS

PAINTED LINES

EXISTING ISLAND

PAINTED LINES

BU

S L

OA

DIN

G

SMALL BUS LOADING

FIRE ROUTE

FIRE R

OU

TE

FIRE ROUTE

FIRE ROUTE

NEW SIDEWALK. REMOVE PLANTER

FIRE R

OU

TE

NEW LIGHT FIXTURE, POLE & BASE.REMOVE EXISTING BASE

161

NEW DIRECTIONAL SIGN - "EXIT"

EXPANDED DRIVING AISLE

EXPANDED ENTRANCE

NEW LIGHT FIXTURE, POLE & BASE

A B A B A B

24001500

EXTEND CURB

3250

EXISTING TREE TO BE REMOVED

EXISTING BELL PEDESTAL TO REMAIN

12

147

6400

8500

6675

6400

8900

8100

EXISTING ISLAND

FIRE ROUTEFIRE ROUTE

EXISTING FENCE TO BE REMOVED

RESURFACE EXISTING DRIVEWAY

RESURFACE EXISTING PARKING LOT

EXISTING WALKWAY TO REMAIN

2A1.1

9000

EXISTING FENCE TO REMAIN

6400

EXISTING ASPHALT TO REMAIN

EXISTING ASPHALT TO REMAIN

RESURFACE EXISTING DRIVEWAY

NEW RETAINING WALL. REFER TO CIVIL DRAWINGS

EXISTING FENCE. REMOVE AND REPLACE GATES AND MESH DURING REPAVING.

EXISTING CONC. SLAB TO REMAIN

EXISTING STOP SIGN TO REMAIN

22387

EXISTING STOP SIGN TO REMAIN

EXISTING SIGN TO BE RELOCATED

REMOVE EXISTING ASPHALT SIDEWALK. REINSTATE TOPSOIL & SOD

REMOVE EXISTING CONCRETE SIDEWALK

NEW CURB

1500 2995 8490

NEW CURB

NEW STOP SIGN

EXISTING WALKWAY TO REMAIN

NEW SIDEWALK

EXISTING ASPHALT TO REMAIN

NEW LIGHT FIXTURE, POLE & BASE

LIGHT FIXTURE & POLE TO BE REMOVED

PAINTED LINES

PAINTED LINES

BH 1

BH 2

BH 7

BH 3

BH 3

BH 5

PAINTED LINES

EXISTING LIGHT FIXTURE AND POLE TO BE REPLACED

LF

LF

LFS

S

LF

LF

LF

LF

LF

PAINTED LINES

7008

BH 4

1.2m HT. CHAIN LINK FENCE TO EDGE OF NEW SIDEWALK

REMOVE EXISTING ASPHALT SIDEWALK. REINSTATE TOPSOIL & SOD

PAINTED LINES & SYMBOLS

EXISTING TREE TO BE REMOVED

EXISTING TREE TO BE REMOVED

NEW LIGHT FIXTURE, POLE & BASE.REMOVE EXISTING BASE

NEW LIGHT FIXTURE, POLE & BASE.REMOVE EXISTING BASE

NEW LIGHT FIXTURE, POLE & BASE

NEW LIGHT FIXTURE, POLE & BASE

NEW LIGHT FIXTURE, POLE & BASE

LIGHT FIXTURE & POLE TO BE REMOVED

LIGHT FIXTURE & POLE TO BE REMOVED

LIGHT FIXTURE & POLE TO BE REMOVED

EXISTING CONCRETE SIDEWALK TO REMAIN

EXISTING LIGHT FIXTURE AND POLE TO BE REPLACED

REPAIR DISTURBED AREAS WITH SOD & SEED TYP.

REMOVE EXISTING SIGNS. REPLACE WITH ACCESSIBLE PARKING SIGNS

ZONING LEGEND

ZONEI - INSTITUTIONAL

STANDARDS

LOT AREA (MIN)LOT FRONTAGE (MIN)FRONT YARDSIDE YARD (WEST)SIDE YARD (EAST)REAR YARDLANDSCAPINGLOT COVERAGE (MAX)HEIGHT OF MAIN BUILDING

CITY OF BARRIE

REQUIRED/PERMITTED

60,271.7sm179.7m147.5m15.6m38.8m28.6m47.2%17.2%9.7m

1,500 sq.m 30m7m9m5m7m35%35% max.15m

PROVIDED

CB

FH

FIRE ROUTE

NEW SIDEWALK. REMOVE PLANTER, CURB & ASPHALT.

FIR

E R

OU

TE

NEW LIGHT FIXTURE, PLOE & BASE

85005500

6400

FIRE ROUTE

9201

EXISTING FLAGPOLE TO REMAIN

EXISTING CONCRETE WALKWAY TO REMAIN

EXISTING CONCRETE WALKWAY TO REMAIN

6450 5500 2751 5500 8500 5500 5500 6400 5500

NEW SIDEWALK

NEW SIDEWALK & CURB

2000

4500

1500

NEW SIDEWALK & CURB

TYP.600

1500

1831

2361

2700

2700

2700

2700

2350

FIR

E R

OU

TE

FIRE ROUTE

9000

EXISTING CONCRETE WALKWAY TO REMAIN

PAINTED LINES

NEW PAVING. REFER TO CIVIL DRAWINGS

NEW PAVING. REFER TO CIVIL DRAWINGS

PAINTED LINES

EXISTING ASPHALT TO REMAIN

NEW RETAINING WALL. REFER TO CIVIL DRAWINGS

NEW RAILINGS

UP

FIRE R

OU

TE

NEW DIRECTIONAL SIGNAGE - "EXIT"

EXISTING CONCRETE WALKWAY TO REMAIN

EXISTING STOP SIGN TO REMAINNEW STOP SIGN

REMOVE EXISTING ASPHALT WALKWAY. REINSTATE TOPSOIL & SOD

LIGHT FIXTURE & POLE TO BE REMOVED

LF

LF

LF

S

S

NEW LIGHT FIXTURE, POLE & BASE.REMOVE EXISTING BASE

NEW LIGHT FIXTURE, POLE & BASE.REMOVE EXISTING BASE

PAINTED LINES

NEW CURB

EXISTING CURB TO REMAIN

EXISTING CURB TO REMAIN

38X38mm STAINLESS STEEL PIPE RAILING.

900

300

300

300

300

RETAINING WALL SYSTEM

SET POSTS IN NON SHRINK GROUT

THICKEN SLAB AT POSTS

300

900

SIGN

LIGHT FIXTURE

MANHOLE

CATCH BASIN

FIRE HYDRANT

BOREHOLE

GARBAGE BIN

RECYCLING BIN

SYMBOLS

MH

CB

LF

S

FH

BH

G

R

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

As indicated

20

20

-02

-28 1

0:0

0:0

4 A

M

A1.1

Site Plan

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

1 : 750

Site1

NORTH

1 : 250

Site - Centre2

1 : 10

Railing - Typ. Exterior3

No. Description Date

1 Issued for Tender March 2, 2020

Page 3: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

UP

UP UP

DN

DN

DN

DN

UP

UP

UP

UP

DN

UP

UP UP

126G 126B 126C

126

126F

126H126D

130A

130

128

130C

130B

120

122E

124

122A

120A 122F

122 122D

122C

122B

116

114

108

127A

127

123

119

117

117A

115

113

113B

113C

111

109

107

105

101

103

103A

102 100

104

106

106A

106B

106C

106D

110

110A

110B110C

110D108A

112

112A

112B112C

112D

118

118A

116A

118B 118C

118D

C103

C106

C101

C102

C104

C105

134

136

138

C111

144 146

142 146A 150

146C146Bx

148

C112

152 154

156

156A

158 162

160

137135A

135

135F135E

135D135C

135B

131

133 139C

139D

141

143A

139

139B 139A

139H

139G

139E139F

171B

145143

147 151

149

147A 149A

171

171A

161

159

157

155

153

C113

C115

C116

C117

175

129

115A

C108

C109C107 131A

C108

C114

E1

E2

E3

E4

E5

E6E7E8

E9

E10

E11

E12

E13

126A

1A2.3

2A2.1

4A2.1

DOOR OPERATOR

EXISTING 900x2150mm WOOD DOORS

EXISTING DOOR HARDWARE TO BE RECONFIGURED

DOOR BUTTONS

REMOVE EXISTING FLOOR STOP

NEW WALL STOP

GENERAL OFFICE139

COORDINATE OPERATOR INSTALLATION WITH EXISTING MOTION DETECTOR

BEYOND DOOR SWING

600 MINIMUM

BEYOND DOOR SWING

1500 MAXIMUM

AB

OV

E F

LO

OR

90

0 M

INIM

UM

AB

OV

E F

LO

OR

11

00

MA

XIM

UM

MOUNTING AREA FOR DOOR OPERATOR BUTTON

REFER TO O.B.C. 3.8.3.3.(17)

BUTTON TO BE MOUNTED ON LATCH SIDE OF DOOR

DOOR OPERATOR ABOVE

BUTTON TO BE 150m DIAMETER OR 50mm x 100mm RECTANGULAR

NEW GRILLES IN BULKHEAD, REFER TO MECHANICAL

LINE OF BULKHEAD ABOVE

LINE OF CANOPY ABOVE

REMOVE AND REPLACE ALL PERIMETER CAULKING AT CANOPY/WALL JUNCTION PROVIDE CLOSURE AT STEEL CHANNEL.

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

As indicated

20

20

-02

-28 1

0:0

0:0

8 A

M

A2.1

Main Floor

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

1 : 250

Main Floor1

1 : 50

Main Floor - Gen. Office2

1 : 25

Door Button3

Room Finish Schedule

Room Number Name Floor Finish

Walls

Ceiling Finish Comments

North East West South

Wall Finish Base Wall Finish Wall Base Wall Finish Wall Base Wall Finish Wall Base

123 BOY'S WASHROOM PT P PT P PT P PT P PT P

125 GIRL'S WASHROOM PT P PT P PT P PT P PT P

208 GIRL'S WASHROOM PT P PT P PT P PT P PT P

212 BOYS' WASHROOM PT P PT P PT P PT P PT P

Grand total: 4

1 : 50

Main Floor - Lobby4

No. Description Date

1 Issued for Tender March 2, 2020

Page 4: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

DN

DN

DN

1A2.4

208

212

200

201

202

203

204

205

206207

209210

211 215

C203

219

221

223 225 227

229

231x

234

235

236

237

238

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

255

256

257

258

260

262

264266

268270

272

274

268A

268B

268C

251A

249A

254A

248A

248B

250A

229A229B229C

211A

209A

205A 203A 201A

C201

C202

C206

C207

C208

C209

C210

C211

274A

272A

301

300

302

C204 C205 280 281 282283

233

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

1 : 250

20

20

-02

-28 1

0:0

0:1

0 A

M

A2.2

Second Floor

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

1 : 250

Second Floor1

No. Description Date

1 Issued for Tender March 2, 2020

Page 5: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

A2.3

6

4

7

5

A2.3

10

8

11

9

BOYS WASHROOM123

GIRLS WASHROOM125

PORCELAIN TILE

NEW PARTITIONS

NEW FIXTURES

NEW FIXTURES

NEW WASH BASIN

GB

GB

PORCELAIN TILE

NEW PARTITIONS

NEW FIXTURES

NEW WASH BASIN

NEW FIXTURES

GB

GB

INSTALL COVER PLATES, INFILL HOLES AND REPAINT DOOR FRAME

INSTALL COVER PLATES, INFILL HOLES AND REPAINT DOOR FRAME

FS

ND

FS

ND

FS

ND

FS

ND

FS

ND

FS

ND

CH

CH

MIRROR

SD

HD

CD

MIRRORHD

TTDTTD

TTD TTD

SD

REPAIR MASONRY CHASE WALL AS REQUIRED

GB GB

750

750

BOYS WASHROOM123

GIRLS WASHROOM125

REMOVE DOOR & HARDWARE

REMOVE TOILET PARTITIONS HARDWARE & GRAB BARS

REMOVE PLUMBING FIXTURES - REFER TO MECHANICAL

REMOVE HAND DRYER -REFER TO ELECTRICAL

REMOVE MIRROR

REMOVE SIGN HOLDER

REMOVE EXISTING V.C.T. FLOORING AND BASE

REMOVE SOAP DISPENSER

REMOVE DISPENSER

REMOVE DOOR & HARDWARE

REMOVE SIGN HOLDER

REMOVE HAND DRYER -REFER TO ELECTRICAL

REMOVE PLUMBING FIXTURES -REFER TO MECHANICAL

REMOVE MIRROR

REMOVE SOAP DISPENSER

REMOVE TOILET PARTITIONS HARDWARE & GRAB BARS

REMOVE EXISTING V.C.T. FLOORING AND BASE

REMOVE DISPOSALS TYP.

REMOVE DISPENSERS TYP.

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

REPAIR CONCRETE FLOOR AT REMOVED FIXTURE

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

BOYS WASHROOM123

GIRLS WASHROOM125

NEW SUSPENDED GYPSUM BOARD CEILING

REFER TO MECHANICAL & ELECTRICAL DRAWINGS

NEW SUSPENDED GYPSUM BOARD CEILING

REFER TO MECHANICAL & ELECTRICAL DRAWINGS

PORCELAIN TILE BASE PORCELAIN TILE BASE

NEW WASH BASINREFER TO MECHANICAL

REPAIR HOLES AND REPAINT DOOR FRAME

HD SD

MIRROR

600

PORCEAIN TILE BASE

GRAB BARSOBC 3.8.3.10.(2)(b)

NEW WASH BASINREFER TO MECHANICAL

NEW FIXTURESREFER TO MECHANICAL

PORCELAIN TILE BASE

NEW PARTITIONS

NEW WASH BASINREFER TO MECHANICAL

DOOR PULLOBC 3.8.3.1.(1)(c)(v)

PORCELAIN TILE BASEPORCELAIN TILE BASE

NEW WASH BASINREFER TO MECHANICAL

REPAIR HOLES AND REPAINT DOOR FRAME

SDHD

MIRROR

600

NEW PARTITIONS

NEW WASH BASINREFER TO MECHANICAL

PORCELAIN TILE BASE

DOOR PULLOBC 3.8.3.1.(1)(c)(v)

PORCELAIN TILE BASE

NEW PARTITIONS

BOYS WASHROOM123

GIRLS WASHROOM125

REMOVE SUSPENDED CEILING & FRAMING SYSTEM

REMOVE EXISTING LIGHT FIXTURES TYP.

REMOVE EXISTING MECHANICAL GRILLES & DIFFUSERS TYP.

REMOVE EXISTING GYPSUM CEILING & FRAMING SYSTEM

REMOVE EXISTING LIGHT FIXTURES TYP.

REMOVE EXISTING MECHANICAL GRILLES, ACCESS PANELS & DIFFUSERS TYP.

S

E

S

A.P.

A.P. A.P.

S

A.P.

LIGHT FIXTURE

SPRINKLER HEAD

ACCESS PANEL

SPEAKER

MECH. GRILLE

E EMERGENCY LIGHT

MECH. GRILLE

DEMOLITION LEGEND

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

1 : 50

20

20

-02

-28 1

0:0

0:1

4 A

M

A2.3

Main FloorWashrooms - West

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

1 : 50

Main Floor - West1

1 : 50

Main Floor - West - Demo.2

1 : 50

Main Floor Ceiling - West3

1 : 50

123 East4

1 : 50

123 West5

1 : 50

123 North6

1 : 50

123 South7

1 : 50

125 East8 1 : 50

125 West9

1 : 50

125 North10

1 : 50

125 South11

1 : 50

Main Fl. Clg - West - Demo.12

No. Description Date

1 Issued for Tender March 2, 2020

Page 6: GENERAL NOTES INNISDALE SECONDARY SCHOOL SITE WORKS … · 2020-03-02 · The Certificate of Practice Number of the holder is the holder's BCDN. Name of Practice: 2481 Innisdale Secondary

A2.4

7

A2.4

10

6

45

8

11

9

BOYS WASHROOM212

GIRLS WASHROOM208

JANITOR210

PORCELAIN TILE

NEW PARTITIONS

NEW FIXTURES

NEW WASH BASIN

GB

NEW PARTITIONS

PORCELAIN TILE

NEW FIXTURES

NEW WASH BASINNEW FIXTURES

NEW FIXTURES

GB

GB

GB

INSTALL COVER PLATES, INFILL HOLES AND REPAINT DOOR FRAME

INSTALL COVER PLATES, INFILL HOLES AND REPAINT DOOR FRAME

FS

ND

FS

ND

FS

ND

FS

ND

FS

ND

FS

ND

CH

CH

MIRROR

HD

SD

SD

HD

MIRROR

TTD TTD

TTDTTDTTD

TTD TTD

REPAIR MASONRY CHASE WALL AS REQUIRED

GB GB

750

750

BOYS WASHROOM212

GIRLS WASHROOM208

JANITOR210

REMOVE DOOR & HARDWARE

REMOVE TOILET PARTITIONS HARDWARE & GRAB BARS

REMOVE PLUMBING FIXTURES -REFER TO MECHANICAL

REMOVE HAND DRYER -REFER TO ELECTRICAL

REMOVE SIGN HOLDER

REMOVE EXISTING V.C.T. FLOORING AND BASE

REMOVE SOAP DISPENSER

REMOVE DISPENSER

REMOVE DISPOSALS TYP.

REMOVE SOAP DISPENSER

REMOVE EXISTING V.C.T. FLOORING AND BASE

REMOVE MIRROR

REMOVE TOILET PARTITIONS HARDWARE & GRAB BARS REMOVE PLUMBING FIXTURES -

REFER TO MECHANICAL

EXISTING HEATER TO REMAIN

EXISTING HEATER TO REMAIN

REMOVE DISPENSER TYP.

REMOVE DISPENSER TYP.

REMOVE HAND DRYER -REFER TO ELECTRICAL

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

REMOVE DOOR & HARDWARE

REPAIR CONCRETE FLOOR AT REMOVED FIXTURE

REPAIR CONCRETE FLOOR AT REMOVED FIXTURE

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

REMOVE PORTION OF EXISTING MASONRY CHASE WALL AS REQUIRED FOR MECHANICAL ACCESS.

JANITOR210

BOYS WASHROOM212

GIRLS WASHROOM208

NEW SUSPENDED GYPSUM BOARD CEILING

REFER TO MECHANICAL & ELECTRICAL DRAWINGS

NEW SUSPENDED GYPSUM BOARD CEILING

REFER TO MECHANICAL & ELECTRICAL DRAWINGS

NEW WASH BASINREFER TO MECHANICAL

NEW PARTITIONS

PORCELAIN TILE BASE

REPAIR HOLES AND REPAINT DOOR FRAME

SD

MIRROR

HD

600

PORCELAIN TILE BASE

NEW FIXTURESREFER TO MECHANICAL

NEW PARTITIONS

EXISTING HEATER TO REMAIN

PORCELAIN TILE BASE

NEW PARTITIONS

DOOR PULLOBC 3.8.3.1.(1)(c)(v)

NEW PARTITIONS

NEW WASH BASINREFER TO MECHANICAL

PORCELAIN TILE BASE

PORCELAIN TILE BASE

NEW WASH BASINREFER TO MECHANICAL

REPAIR HOLES AND REPAINT DOOR FRAME

SDHD

MIRROR

600

PORCELAIN TILE BASE

NEW FIXTURESREFER TO MECHANICAL

EXISTING HEATER TO REMAIN

PORCELAIN TILE BASE

NEW FIXTURESREFER TO MECHANICAL

NEW WASH BASINREFER TO MECHANICAL

GRAB BARSOBC 3.8.3.10.(2)(b)

NEW PARTITIONS

PORCELAIN TILE BASE

DOOR PULLOBC 3.8.3.1.(1)(c)(v)

JANITOR210

BOYS WASHROOM212

GIRLS WASHROOM208

REMOVE SUSPENDED CEILING & FRAMING SYSTEM

REMOVE EXISTING LIGHT FIXTURES

REMOVE EXISTING MECHANICAL GRILLES & DIFFUSERS

REMOVE SUSPENDED CEILING & FRAMING SYSTEM

REMOVE EXISTING LIGHT FIXTURES

REMOVE EXISTING MECHANICAL GRILLES & DIFFUSERS

E

S

S

E

S

A.P.

LIGHT FIXTURE

SPRINKLER HEAD

ACCESS PANEL

SPEAKER

MECH. GRILLE

E EMERGENCY LIGHT

MECH. GRILLE

DEMOLITION LEGEND

Scale

Project number

Date

Drawn by

Checked by

705 721 0265705 734 3580

FaxTel.

L4N 1T1Barrie, Ont

76 Mary Street

TEDHANDYASSOCIATES

and

ARCHITECTInc.

GENERAL NOTES

ALL DRAWINGS ARE THE PROPERTY OF THE ARCHITECT. REPRODUCTION OF DRAWINGS WITHOUT WRITTEN PERMISSION OF THE ARCHITECT IS PROHIBITED.

THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY.

ALL WORK SHALL CONFORM TO THE LATEST EDITION OF THE ONTARIO BUILDING CODE.

IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE ALL STRUCTURAL, MECHANICAL AND ELECTRICAL WORK.

1 : 50

20

20

-02

-28 1

0:0

0:1

8 A

M

A2.4

Second FloorWashrooms - West

1917

Innisdale SSRenovation95 Little Avenue Barrie, ON.

August 9, 2019

EM

EPH

1 : 50

2nd Fl -West1

1 : 50

2nd Fl -West - Demo.21 : 50

2nd Floor - Ceiling - West3

1 : 50

208 East4

1 : 50

208 West5

1 : 50

208 North6

1 : 50

208 South7

1 : 50

212 East8

1 : 50

212 West9

1 : 50

212 North10

1 : 50

212 South11

1 : 50

2nd Fl.- CLg - West - Demo.12

No. Description Date

1 Issued for Tender March 2, 2020