geiec devices c-2000™ 4-pole contactors · 2015. 7. 15. · cl01a400t* cl02a400t* cl03a400m*...
TRANSCRIPT
|U U
GEIEC Devices
C-2000™ 4-Pole ContactorsNonreversing Only
To complete the contactor catalog number, replace theappropriate digit from the Coil Selection table.
t, **, or 11 in the catalog number with the
7.5-60 Hp (460 V) AC Only
* Coil SelectionFor catalog numbers withprefixes CL01, CL02, CL03,CL04, CL05, CL07, CL08and CL09.
AC-3Max.
Amps@460V
13.8
17.5
25
32
42
62
68
80
Single-Phase
1 1 5 V
0.751
2
2
3
5
5
7.5
230V
2
3
3
5
7.5
10
10
1 5
Three-Phase
200V
3
5
7.5
10
10
20
20
25
230V
3
5
7.5
10
15
20
25
30
460V
7.5
10
15
20
30
40
50
60
575V
10
15
20
25
•30
50
60
75
Aux.Contacts
(A600,Q600)
None
None
None
None
None
None
None
None
CoilVolts
AC
AC
AC
AC
AC
AC
AC
AC
4 Normally Open
Catalog No. ffl
CL01A400T*
CL02A400T*
CL03A400M*
CL04A400M*
CL05A400M*
CL07A400M*
—
CL09A400M*
List Price,GO-10C2
$109.00
143.00
176.00
225.00
340.00
425.00
—
475.00
2 Normally Open2 Normally Closed
Catalog No.
CL01ABOOT*
CL02ABOOT*
CL03ABOOM*
CL04ABOOM*
CL05ABOOM *
CL07ABOOM*
CL08ABOOM*
-
List Price,GO-10C2
$109.00
143.00
176.00
225.00
340.00
425.00
447.00
-
AC Voltage
60 Hz
24
48
120
208
277
240
480
—
600
50 Hz
24
42
1 1 0
—
220/230
—
380/400
415
500
*CoilSuffix
1
F
J
L
N
S
U
wY
Note: Additional coils available,see page 3-16.
125-500 Hp (460 V) AC/DCAC-3Max.
Amps@460V
156
192
302
398
398
480
480
602
Three-Phase
200V
50
60
100
125
125
150
150
200
230V
60
75
100
150
150
200
200
250
460V
125
150
250
300
300
400
400
500
575V
125
150
300
400
400
500
500
600
Aux.Contacts
(A600,Q600)
1NO-1NC®
1 NO-1 NC ffl
1 NO-1 NC ffl
1NO-1NC©
1 NO-1 NC ffl
1 NO-1 NC ffl
1NO-1NC®
1 NO-1 NC ffl
CoilVolts
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
4 Normally Open
Catalog No. ffl
CK08BE41 1 1
CK09BE411t
CK95BE411t
CK10CE41lt
CK10BE41lt
CK11CE41 l t
CK11BE41 l t
CK12BE411t
List Price,GO-10C2
$1,375.00
1,750.00
2,250.00
3,520.00
3,872.00
5,250.00
5,775.00
6,900.00
tCoil SelectionFor catalog numbers withprefixes CK08, CK09, CK95,CK10, CK11,andCK12.
AC60/50 Hz
24-28
42-48
1 1 0 - 1 2 7
220-250
380-415
440-500
DC
24-28
42-48
110-127
220-250
380-415
440-500
tCoilSuffix
D
F
J
N
U
Y
® Auxiliary contact shipped unassembled.
7.5-60 Hp (460V), DC Only or AC/DCAC-3Max.
Amps@460V
13.8
17.5
25
32
48
62
68
80
Single Phase— HP60 Hz
115V
0.75
1
2
2
3
5
5
7.5
230V
2
3
3
5
7.5
10
10
1 5
Three Phase— HP 60Hz
200V
3
5
7.5
10
10
20
20
25
230V
3
5
7.5
10
1 5
20
25
30
460V
7.5
10
15
20
30
40
50
60
575V
10
1 5
20
25
30
50
60
75
kW50Hz
380/415V
5.5
7.5
12.0
16.0
18.5
30.0
37.0
45.0
Aux.Contacts
(A600,Q600)
None
None
None
None
None
None
None
None
CoilVolts
DC
DC
DC
DC
AC/DC
AC/DC
AC/DC
AC/DC
4 Poles Normally Open
Catalog No.
CL01D400T**
CL02D400T**
CL03D400M**
CL04D400M**
CL05E400Mtt
CL07E400Mtt
—
CL09E400Mtt
List Price,GO-10C2
$132.00
166.00
232.00
263.00
405.00
484.00
—
544.00
2 Poles Normally Open,2 Poles Normally Closed
Catalog No.
CL01DBOOT**
CL02DBOOT**
CL03DBOOM"
CL04DBOOM**
CLOSEBOOMtt
CL07EBOOMtf
CLOBEBOOMtt
' -
List Price,GO-10C2
$132.00
166.00
232.00
263.00
405.00
484.00
516.00
-
Coil Selection TablesForCLOl— CL04(**)
DC Volts
122448
120/125250
CoilSuffix
BDGKT
ForCL05-CL09(tt)DC/ACVoits
24-2842-48
110-127220-250
CoilSuffix
DFJN
Note: Additional coilsavailable, see page 3-16.
Prices and data subject to change without notice 1999 Issue 3-7
LJ-
GEIEC Devices
General Specifications for C-2000™ Contactors & Starters
Standards And Listings EC 947-1EC 947-4EC 158-1CENELECHD419NFC.63-110
BS 5424BS775CEI 1 7-3/252ASE 1 025UL508
CSAC.22.2/14EN 50005UNE20109VDE 0660/1 02CE Mark
ZH1/457 (Positive Guided Contacts)
Pending StandardsAnd Listings
SEMKO, NEMKO, DEMKO, Lloyds Register
Ambient TemperatureOperatingStorage .
-13° to +131°F/-25°to +55°C-58° to +176°F/-50°to +80°C
Altitude DeratingUp to 10,000 ft. ;
(3,000 m)10,000 to 13,200 ft.(3,000 to 4,000 m)13,200 to 16,000 ft.(4,000 to 5,000 m)
Nominal Values
90% rated current
80% rated current
Rated Insulation Voltage 600 Vac, U, = 1000V (per EC 947)
Mounting Position3-Pole and 4-PoleCL Contactors (5-75 Hp)
To maintain operating integrity, the contactor must be mounted in one of the positions shown below:
i) o o o]QDOQ[
o o oIo
oo
!dHBSF!F!
ooo J
o o oDDDDDD
DDDDQD000
[ ooo
HHD 1=1a 1=1a en
Ooo
3-Pole and 4-PoleCK Contactors(100-500 Hp)
The contactor must be installed vertically or tilted a maximum of 30° from vertical, as shown below:
3-36 1999 Issue Data subject to change without notice