gear drive flo-tap installation instructions

26
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: 00825-0400-4809 rev. EA – 485 Flanged Flo- tap 00825-0500-4809 rev. DB – 485 Threaded Flo- tap 00825-0200-4585 rev. AA – 585 Flanged Flo- tap

Upload: elda

Post on 23-Mar-2016

43 views

Category:

Documents


1 download

DESCRIPTION

Gear Drive Flo-tap Installation Instructions. Quick Installation Guides: 00825-0400-4809 rev. EA – 485 Flanged Flo-tap 00825-0500-4809 rev. DB – 485 Threaded Flo-tap 00825-0200-4585 rev. AA – 585 Flanged Flo-tap. Nomenclature. Instrument Connections. Lift Rings. Top Plate. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Gear Drive Flo-tap Installation Instructions

Gear Drive Flo-tap Installation InstructionsQuick Installation Guides:00825-0400-4809 rev. EA – 485 Flanged Flo-tap00825-0500-4809 rev. DB – 485 Threaded Flo-tap00825-0200-4585 rev. AA – 585 Flanged Flo-tap

Page 2: Gear Drive Flo-tap Installation Instructions

Nomenclature

Gear Box

Top Plate

Gear Drive Plate

Lift Rings

Instrument Connections

Rod Protectors

Full Port Isolation Valve

Page 3: Gear Drive Flo-tap Installation Instructions

Weld the Mounting Hardware Onto the Pipe

Threaded Flo-tap Flanged Flo-tap

Page 4: Gear Drive Flo-tap Installation Instructions

Tack Weld the Mounting Hardware with 4 Equal Length Tacks Tack weld anywhere on

the mounting hardware Then again directly across

from the first tack weld Then on the other 2 sides

2

1

3

Page 5: Gear Drive Flo-tap Installation Instructions

Check to See that the Mounting Hardware is Level and Square If it’s not, use a

rubber mallet to lightly adjust the hardware and recheck

Page 6: Gear Drive Flo-tap Installation Instructions

Verify that the ODF Dimension Matches What is Listed in the QIG The ODF is the dimension from outside pipe diameter to face of flange

485 585

Page 7: Gear Drive Flo-tap Installation Instructions

Verify that the ODF Dimension Matches What is Listed in the QIG The ODF is the dimension from outside pipe diameter to face of flange

For Threaded Flo-tap the dimension from the pipe OD to the top of the threadolet is called LMH:485 Sensor Size 1: 1.38-in. (35 mm)485 Sensor Size 2: 1.56-in. (40 mm)485 Sensor Size 3: 2.06-in. (52 mm)

Page 8: Gear Drive Flo-tap Installation Instructions

Complete a Continuous Weld Around the Perimeter of the Unit

Page 9: Gear Drive Flo-tap Installation Instructions

Attached the Full Port Valve to the Mounting HardwareThreaded Flo-tapFirst, thread the guide nipple into the mounting then thread the valve

Flanged Flo-tap

The valve stem should be in-line with the pipe so it will not interfere with the insertion rods

The valve must be a full port valve to allow the Annubar to pass through the valve into the pipe

ODV

Page 10: Gear Drive Flo-tap Installation Instructions

Verify the ODV DimensionThe ODV is the dimension from the outer diameter of the pipe to the top of the valveFlo-tap / Flange Rating

485 Sensor Size 585 Sensor Size ODV Dimension

Threaded1 --- 7.51-in. (190.9 mm)

2 --- 8.17-in. (207.5 mm)

ANSI 150 # 1 11 10.5-in. (266.7 mm)

ANSI 300 # 1 11 11.75-in. (298.5 mm)

ANSI 600# 1 11 14.06-in. (357.2 mm)

ANSI 150 # 2 22 11.25-in. (285.8 mm)

ANSI 300 # 2 22 13.00-in. (330.2 mm)

ANSI 600# 2 22 16.38-in. (416.0 mm)

ANSI 150 # 3 44 12.75-in. (323.9 mm)

ANSI 300 # 3 44 16.25-in. (412.8 mm)

ANSI 600# 3 44 19.50-in. (495.3 mm)

Page 11: Gear Drive Flo-tap Installation Instructions

Drill the Hole by Using a Hot Tap Drilling Machine

Tag with correct drill hole size attached to the Annubar

Guide Ring in Rosemount Supplied Mounting Hardware

Page 12: Gear Drive Flo-tap Installation Instructions

After the Hole is Drilled, Retract the Drill Past the Valve and Close the ValveVent drilling machine and remove the per manufacturers

and site proceduresThreaded Flo-tap Flanged Flo-tap

Remember that the hot tap drilling machine is under pressure and exposed to the process fluid

Page 13: Gear Drive Flo-tap Installation Instructions

Attach the Fully Retracted Flo-tap Assembly to the Valve

Threaded Flo-tap

Page 14: Gear Drive Flo-tap Installation Instructions

Attach the Fully Retracted Flo-tap Assembly to the Valve

Flanged Flo-tap – Use a hoist strap and crane if needed

Page 15: Gear Drive Flo-tap Installation Instructions

Quickly Open and Close the Valve to Pressurize the Annubar, Check for Leaks

Page 16: Gear Drive Flo-tap Installation Instructions

If Leaks are Present, Tighten the Packing Gland Nuts

Page 17: Gear Drive Flo-tap Installation Instructions

Attach Rod Protectors

Page 18: Gear Drive Flo-tap Installation Instructions

Caution During InsertionDuring insertion, the top plate can twist due to the torque of the gear drive. To keep the Annubar from twisting, hold the top plate in place during insertion. Gear Drive

PlateTop Plate

Shown twisted ~90° from Gear Drive Plate

Top Plate and Gear Drive Plate should remain parallel during insertion

Page 19: Gear Drive Flo-tap Installation Instructions

If Using a Drill for Insertion, Attach the Drill to the Insertion Mechanism Do not exceed

200 RPM on the Drill

Page 20: Gear Drive Flo-tap Installation Instructions

Insert the AnnubarStop the drill and crank by hand once the orange stripes reach the Gear Box Plate

Page 21: Gear Drive Flo-tap Installation Instructions

Continue to Insert the Sensor with the Manual Crank

Page 22: Gear Drive Flo-tap Installation Instructions

Place a finger above the packing gland to feel for full insertion CAUTION: Be

careful if doing this with steam or other harmful fluids

When movement stops, the Annubar is fully inserted

Page 23: Gear Drive Flo-tap Installation Instructions

Turn the handle an additional ½ turn to ensure it is fully inserted

Page 24: Gear Drive Flo-tap Installation Instructions

Insert the Drive Lock Pin to Secure the Sensor in Place

Page 25: Gear Drive Flo-tap Installation Instructions

Tighten the Nuts to the Gear Box Plate and Loosen ¼ turnThis gives an indication of full insertion if the Annubar is retracted at a later date.

Page 26: Gear Drive Flo-tap Installation Instructions

Retighten the Packing Gland Nuts