geant4 flux simulations
DESCRIPTION
Geant4 FLUX SIMULATIONS. Dorothea Pfeiffer. GIF++ Discussion 21.02.2013. GIF++ Geometry. Irradiator with lead filters RPC chambers surrounded by 4 cm of steel Floor chamber also covered by 17 cm of steel Beam trigger shielded by 5mm Tungsten rubber - PowerPoint PPT PresentationTRANSCRIPT
GEANT4 FLUX SIMULATIONS
Dorothea PfeifferGIF++ Discussion21.02.2013
2
GIF++ Geometry
21.02.2013Dorothea Pfeiffer
roof chamberIrradiator with filter frame
floor chamber
Steel floor (2 cm)
Finetracking chamber
• Irradiator with lead filters• RPC chambers surrounded by 4 cm of steel• Floor chamber also covered by 17 cm of steel• Beam trigger shielded by 5mm Tungsten rubber• Roof chamber shielded by 2 cm lead plate in air
Lead shield for roof chamber
Beam trigger
Beam trigger
3
GIF++ coordinate system
Dorothea Pfeiffer
Muon beam x=0cm, y = 0 cm
Source x= -200 cm, y = 0 cm, z = 0 cm (cosmics) x= -50 cm, y = 0 cm, z = 0 cm (muons)
Cosmic trigger floor Position: x=-200 cm, y=-197.5 cm, z= 300 cm
Dimension: x= 240 cm, y=20cm, z=280 cm
Fine tracker Position: x=-200 cm, y=-158 cm, z = 110 cm Dimension: x=50 cm, y=20 cm, z = 100 cm
Roof chamber Position: x=-200 cm, y=330 cm, z = 255 cm Dimension: x=50 cm, y=40 cm, z = 100 cm
Beam trigger Positions: x=0 cm, y= 0 cm, z = +/- 600 cm Dimension: x=60 cm, y=40 cm, z = 20 cm
21.02.2013
4
GIF++ projection yz source
Dorothea Pfeiffer
21.02.2013
roof chamber
Lead shield
steel platefine trackerfloor
chamber
Average flux above source 4.7e5 s^-1 cm^ -2
5
GIF++ projection yz beam line
Dorothea Pfeiffer
21.02.2013
beam trigger beam trigger
Downstream average flux 1.8e4 s^-1 cm^ -2
Upstream average flux 5.9e4 s^-1 cm^ -2
6
GIF++ projection xz source
Dorothea Pfeiffer
13.02.2013
beam trigger beam trigger
Downstream average flux 1.8e4 s^-1 cm^ -2
Upstream average flux 5.9e4 s^-1 cm^ -2
7
GIF++ projection xz top of floor
Dorothea Pfeiffer
21.02.2013
fine tracker
Average flux 5.1e5 s^-1 cm^ -2
8
GIF++ projection xz under floor
Dorothea Pfeiffer
21.02.2013
floor chamber
Average flux 1.2e3 s^-1 cm^ -2
9
GIF++ projection xz roof
Dorothea Pfeiffer
21.02.2013
roof chamber
Average flux 1.0e5 s^-1 cm^ -2
10
GIF++ example spectra
Dorothea Pfeiffer
21.02.2013
Fine tracker
Roof chamber