Imagination at work. Revolution ACT EX Clinical Image Gallery GE Healthcare

Upload: gaurav-shah

Post on 11-Apr-2017

421 views

Category:

Healthcare


10 download

TRANSCRIPT

Imagination at work.

Revolution ACT EX Clinical Image

Gallery

GE Healthcare

• No posterior fossa artifact • ODM to save dose to eye without image penalty • Clarity Detector and Imaging chain – no streak artifacts from sharp bone edges

Excellent grey white differentiation ASIR improves Low Contrast Detectability40 % reduction in dose

Axial mode : 5mm2/i Algorithm : Soft/SS50140 kV 100 mA Sacn time: 2s 14 rotations

Routine Brain Scan with ASIR Images courtesy Aaarthi Scans Chennai

DSA Circle of WillisSubtraction AngioBone free CT angio for head and neck regionWith DSA technqiue

Subtraction image shows well defined vessel delineation

Images courtesy Aaarthi Scans Chennai

Helical 140 kV 110 mA1s, 0.625 mm, Pitch 1:1Scan time : 19 s Algorithm: Bone+ASIR 40 %IQ Enhance ON

Hi Res IACImages courtesy Aaarthi Scans Chennai

Axial Mode Rotation time 1s 140 kV 95 mA Sub-mm 0.625mm x 2i mode Algorithm: Bone+

Dose Information Eff Dose = 0.49 mSv (DLP 35.19 ) *EDLP – ICRP Publication 102 , Chest factor 0.014

HRCT – Chest with Sub mm Slices Images courtesy Aaarthi Scans Chennai

Helical 120 kV Auto mA, NI 151s, 5 mm, Pitch 1.675Scan time : 21 s Algorithm: CHST/SS40

Hi Resolution CECT Chest

70 ml of Omnipaque 300 mgI/dL30 ml of saline

Images courtesy Aaarthi Scans Chennai

Min IP and Bronchogram Images courtesy Aaarthi Scans Chennai

Low dose Pulmonary Angio

Pulmonary Angio thick MIP images shows thrombus in the R &L pulmonary arteries

DLP 62, Eff Dose – 0.86 mSv

Images courtesy Aaarthi Scans Chennai

Low dose dual phase liver study shows visualization of hepatic portal vasculature

Helical 120 kV Auto mA - 30 to 160 mA Scan time: 1s, Algorithm: STDASIR : 50%245 mm Coverage Scan time 14 s 1.25 mm slices Pitch 1.675:1

Dose Information Eff Dose = 5.2 mSv (DLP 351.24) *EDLP – ICRP Publication 102 , Abd factor 0.015

Images courtesy Aaarthi Scans Chennai

Renal Angio Autobone Xpress

Helical 120 kV Auto mAASIR 400.98 s, 1.25 mm, Pitch 1.675:1Scan time : 1sAlgorithm: CHST80 ml Omnipaque 300 mgI/dL3 ml/sec flowrate with inj

Eff Dose = 2.51 mSv

Images courtesy Aaarthi Scans Chennai

Hi Res Aortic + LL Angio

350 mg of Iodine 130 ccWith the flow rate of 3 ml/secUsing smart prep technique

Increased LCDNoise suppression with ASIRNice anatomical visualizationLonger coverageTotal DLP 409 for 1200 mm

Increased LCDNoise suppression with ASIRNice anatomical visualizationLonger coverage

Peripheral Angio of normal lower limb vasculature extending distal end anatomy

Images courtesy Aaarthi Scans Chennai

Metal artifact reduction with ASIRAsir reduces artifacts from metal upto a percentage and can visualize bone to metal intact margins for post op erativeEvaluation and follow up

Eff Dose = 3.30 mSv

Helical 140 kV AutomA, NI 181 s, 1.25 mm Pitch 1.375:1Scan time : 42 sCoverage 589 mmAlgorithm: BoneASIR 80 %

Images courtesy Aaarthi Scans Chennai

Thank you!