Functional description The electronic locks GAT NET.Lock 7000 are connected to slave control- lers GAT NET.Controller S 7000. Up to 24 locks can be connected to one slave controller. Each slave controller in a system is further connected via serial RS 485 interface to a master controller GAT NET.Controller M 7000. To use a locker, the user presses the locker door shut and holds his data carrier up to the reader centre of the GAT NET.Lock 7000. The lock reads the data carrier information and sends the information to the slave con- troller. Depending on the operation type (Online/Offline) the user data are checked by the controller autonomously or by a PC software on the server. The controller or server response will then signal the lock to lock or unlock the locker door. The locking status of the door is signalled by the lock‘s status LED. Highlights •Up to 24 GAT NET.Lock 7000 per GAT NET.Controller S 7000 • Different operation modes possible • Reliable data transmission between the reader and data carrier • For left and right doors and various types of locker doors • Self-adjustment of the RFID field • LED status display (multi-colour) • Motor driven locking/unlocking for highest reliability • Different bolt sets with integrated RFID booster • Easy and secure bolt mounting • Front plate for metallic doors (for labelling with locker number and logo etc.), individual designs possible GAT NET.Lock 7000 Electronic Locker Locks Application The GAT NET.Lock 7000 is the ideal solution for the convenient electronic locking of wardrobe lockers in fitness clubs, baths, golf resorts, and other individual company applications. The identification at the GAT NET.Lock 7000 is carried out via contactless RFID data carriers (Radio Frequency Identification). The GAT NET.Lock 7000 is suitable for different locker door materials (wood, HPL, fully synthetic materials, glass or even metal doors when using the booster unit) and is useable for doors that open to the left or right. The various operating modes enable the flexible use of these locks. Slave controllers GAT NET.Controller S 7000 are used for communication and control of the GAT NET.Lock 7000. They are available for several RFID technologies (LEGIC ® and MIFARE TM + ISO 15693). Description PartNo. GAT NET.Lock 7000 Electronic RFID locker lock 368534 1 www.gantner.com Order information Description PartNo. GAT NET.Controller M 7000 Master controller for the slave controllers GAT NET. Controller S 7000 253224 GAT NET.Controller S 7000 B Slave control unit for the electronic locker locks GAT NET. Lock 7000, with integrated LEGIC ® reader. 253325 GAT NET.Controller S 7000 F/ISO Slave control unit for the electronic locker locks GAT NET. Lock 7000, with integrated MIFARE TM /ISO 15693 reader. 253426 GAT NET.Lock Tool 7000 Center punch gage for bolt mounting 533831 GAT NET.Lock Connector Connector for connection cables 442123 GAT NET.Lock Cable 4m Cable for connection of the GAT NET.Lock 7000, length 4 m, 4-pin plug on both sides 321826 GAT NET.Lock Label GEA right GAT NET.Lock Label GEA NUM right Self-adhesive door label in GANTNER design, for right- hinged doors, without/with locker number 679034 679236 GAT NET.Lock Label GEA left GAT NET.Lock Label GEA NUM left Self-adhesive door label in GANTNER design, for left- hinged doors, without/with locker number 370022 679135 Accessories Accessories Valid as from September 27 th 2013 • Technical data subject to modifications without notice! DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734 GAT NET.Lock 7000 GAT NET.Lock BoltSet 7100 P Description PartNo. GAT NET.Lock Basic Set B GAT NET.Lock Basic Set F GAT NET.Lock Basic Set ISO The sets include master cards 369131 369232 369333 GAT NET.Lock BoltSet 7100 Door shackle carrier and booster for non-metallic doors 369535 GAT NET.Lock BoltSet 7200 Door shackle carrier and booster for metallic doors 532123

Upload: lykhue

Post on 19-Apr-2018

221 views

Category:

Documents


3 download

TRANSCRIPT

Functional descriptionThe electronic locks GAT NET.Lock 7000 are connected to slave control-

lers GAT NET.Controller S 7000. Up to 24 locks can be connected to one

slave controller. Each slave controller in a system is further connected via

serial RS 485 interface to a master controller GAT NET.Controller M 7000.

To use a locker, the user presses the locker door shut and holds his data

carrier up to the reader centre of the GAT NET.Lock 7000. The lock reads

the data carrier information and sends the information to the slave con-

troller. Depending on the operation type (Online/Offline) the user data

are checked by the controller autonomously or by a PC software on the

server. The controller or server response will then signal the lock to lock

or unlock the locker door. The locking status of the door is signalled by

the lock‘s status LED.

Highlights•Upto24GATNET.Lock7000perGATNET.ControllerS7000

•Differentoperationmodespossible

•Reliabledatatransmissionbetweenthereaderanddatacarrier

•Forleftandrightdoorsandvarioustypesoflockerdoors

•Self-adjustmentoftheRFIDfield

•LEDstatusdisplay(multi-colour)

•Motordrivenlocking/unlockingforhighestreliability

•DifferentboltsetswithintegratedRFIDbooster

•Easyandsecureboltmounting

•Frontplateformetallicdoors(forlabellingwithlockernumberandlogo

etc.), individual designs possible

GAT NET.Lock 7000Electronic Locker Locks

ApplicationThe GAT NET.Lock 7000 is the ideal solution for the convenient electronic

locking of wardrobe lockers in fitness clubs, baths, golf resorts, and other

individual company applications. The identification at the GAT NET.Lock

7000iscarriedoutviacontactlessRFIDdatacarriers(RadioFrequency

Identification).

The GAT NET.Lock 7000 is suitable for different locker door materials

(wood, HPL, fully synthetic materials, glass or even metal doors when

using the booster unit) and is useable for doors that open to the left or

right. The various operating modes enable the flexible use of these locks.

Slave controllers GAT NET.Controller S 7000 are used for communication

and control of the GAT NET.Lock 7000. They are available for several

RFIDtechnologies(LEGIC®andMIFARETM+ISO15693).

Description PartNo.

GAT NET.Lock 7000

ElectronicRFIDlockerlock

368534

1www.gantner.com

Order information

Description PartNo.

GAT NET.Controller M 7000

Master controller for the slave controllers GAT NET.

Controller S 7000

253224

GAT NET.Controller S 7000 B

Slave control unit for the electronic locker locks GAT NET.

Lock7000,withintegratedLEGIC® reader.

253325

GAT NET.Controller S 7000 F/ISO

Slave control unit for the electronic locker locks GAT NET.

Lock7000,withintegratedMIFARETM/ISO15693reader.

253426

GAT NET.Lock Tool 7000

Center punch gage for bolt mounting

533831

GAT NET.Lock Connector

Connector for connection cables

442123

GAT NET.Lock Cable 4m

Cable for connection of the GAT NET.Lock 7000, length 4 m,

4-pin plug on both sides

321826

GAT NET.Lock Label GEA right

GAT NET.Lock Label GEA NUM right

Self-adhesive door label in GANTNER design, for right-

hinged doors, without/with locker number

679034

679236

GAT NET.Lock Label GEA left

GAT NET.Lock Label GEA NUM left

Self-adhesive door label in GANTNER design, for left-

hinged doors, without/with locker number

370022

679135

Accessories

Accessories

Valid as from September 27th 2013 • Technical data subject to modifications without notice! DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

GAT NET.Lock 7000

GAT

NE

T.Lo

ck B

olt

Set

71

00

PR

ELIM

INA

RY

Description PartNo.

GAT NET.Lock Basic Set B

GAT NET.Lock Basic Set F

GAT NET.Lock Basic Set ISO

The sets include master cards

369131

369232

369333

GAT NET.Lock BoltSet 7100

Door shackle carrier and booster for non-metallic doors

369535

GAT NET.Lock BoltSet 7200

Door shackle carrier and booster for metallic doors

532123

Nominal voltage UDC: 5 V

Power supply: Via connection cable from the slave controller

Aver. power consumption: 60mW

Reader types: GAT NET.Controller S 7000 - B:-F/ISO:

LEGIC®

MIFARETM+ISO15693

Retaining force: Min.1,500N

Forceoninnersideofthedoor: Max.100N

User guidance Multi-Colour status LED

Interface: One-Wire(specialcableforsupply,data andRFsignal)

Number locks per slave cont.: 24

Connectors: MOLEX,typeMicro-Fit3.0TM

Housing material: Plastic (PC)

Door width: min.230mm

Dimensions: 110x100x25mm

Permitted ambient temperature: 0to+60°C

Protection type: IP52

Protection class: I I I

Weight: Approx160g

Environment classbasedonVDS2110: II(conditionsinindoorareas)

2 www.gantner.com

Technical Data

Dimensions

GAT NET.Lock 7000 GATNET.LockBoltSet7100

Typical application

Valid as from September 27th 2013 • Technical data subject to modifications without notice! DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

to the server/host Ethernet

OUT

OUT

IN

OUT

PowerPlug

IN

GAT NET.Controller S 7000 GAT NET.Controller S 7000

Max. 8 slave controllers at one master controllerMax 200 m line length per RS 485 line

RS 485

RS 485 + power

Lockers

Supply

GAT NET.Lock 7000

Supply

Master ControllerGAT NET.Controller M 7000

OUT

OUT

IN

GAT NET.Controller S 7000

RS 485

RS 485 + power

Supply

Supply

Master ControllerGAT NET.Controller M 7000

Identification with RFID data carrier

1. GATNET.Lock7000 5. Doorcontact

2. GATNET.LockBoltSet7100(fornon-metaldoors) 6. Booster

3. GATNET.LockBoltSet7200(formetaldoors) 7. StatusLED

4. Door shackle 8. Label Carrier

GAT NET.Lock BoltSet 7200

78.0 mm (3.07”)

10

4.5

mm

(4

.11

”)

61.8 mm (2.43”)

Top View

Side View Front View

88

.1 m

m (

3.4

7”)

7

7

6

3

8

4

4

5

3

3

8

8

1

1

78.0 mm (3.07”)

10

4.5

mm

(4

.11

”)

61.8 mm (2.43”)

Top View

Side View Front View

88

.1 m

m (

3.4

7”)

7

7

6

3

8

4

4

5

3

3

8

8

1

1

110.0 mm (4.33”)

40.3 mm (1.58”)8

8.1

mm

(3

.47

”)

14

4

5

4

1

2

91.0 mm (3.58”)

10

0.0

mm

(3

.94

”)

25

.0 m

m (

0.9

8”)

50

.0 m

m (

1.9

7”)

94

.0 m

m (

3.7

”)

6.0

mm

(0

.24

”)17.0 mm (0.67”)

7

6

2

2

Top View

Side View Front View

110.0 mm (4.33”)

40.3 mm (1.58”)

88

.1 m

m (

3.4

7”)

14

4

5

4

1

2

91.0 mm (3.58”)

10

0.0

mm

(3

.94

”)

25

.0 m

m (

0.9

8”)

50

.0 m

m (

1.9

7”)

94

.0 m

m (

3.7

”)

6.0

mm

(0

.24

”)17.0 mm (0.67”)

7

6

2

2

Top View

Side View Front View

110.0 mm (4.33”)

40.3 mm (1.58”)

88

.1 m

m (

3.4

7”)

14

4

5

4

1

2

91.0 mm (3.58”)

10

0.0

mm

(3

.94

”)

25

.0 m

m (

0.9

8”)

50

.0 m

m (

1.9

7”)

94

.0 m

m (

3.7

”)

6.0

mm

(0

.24

”)17.0 mm (0.67”)

7

6

2

2

Top View

Side View Front View

3www.gantner.comValid as from September 27th 2013 • Technical data subject to modifications without notice!

DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

Mounting and Installation InstructionsTheGATNET.Lock7000ismountedwith3screws(1)ontheinsideofthe

locker. The bolt set with the door shackle is mounted on the inside of the

lockerdoor.Atnon-metallicdoorsonlyadrillingfortheLEDisrequired.At

metallic doors a cut-out must be made in the door, where the bolt set and

label carrier will be mounted.

Door status contact

The GAT NET.Lock 7000 has a contact which gets activated by the door

contact (5) at the bolt set as soon as the locker door is closed. This allows

to determine the open/close state of the door. To guarantee the correct

functionality of the GAT NET.Lock 7000 it is important that this contact is

clean and not damaged.

Mounting on Non-Metallic Doors

Installation measures for GAT NET.Lock 7000 and Bolt Set

During the mounting, please pay particular attention to the following points:

- Whenthedoorispressedshut,thegapbetweentheboltset(2)andthe

frontoftheGATNET.Lock7000mustnotbeexceed0.5mm.Ideallythe

bolt set should touch the front of the lock.

- Themiddleofthedoorshackle(4)mustbe1mmhigherthanthemiddle

of the door shackle opening in the GAT NET.Lock 7000. This ensures

the door’s ability to close even if the door position is modified 3 mm

downwardsor1mmupwards(tolerance±2mm).

Mounting procedure

Note: Before mounting all locks of the locker system a test installation of

at least one lock and final function check must be performed like

described below. Only if the tests are successful the rest of the

locks may be mounted in the same way.

1. Drill the threeholes (3) for theGATNET.Lock7000 into the locker

wall.

2. Plug-intheconnectioncable(seepage6).

Door width

The minimum allowed door width (measured from the door shackle to the

hinge) is 230 mm. If the door is narrower than this measure, the door

shackle would hit the locker when the door is being closed.

1.GATNET.Lock7000

2.GATNET.LockBoltSet7100

3.Mounting screws for GAT NET.Lock 7000

4. Door shackle

5. Door contact

6.Mountingscrewsforboltset

7. LED (hole in locker door)

3. Mount theGATNET.Lock7000with three screws (3) on the inside

locker wall.

Note: Use the right screws according to the type of locker material.

Attention: The max. allowed tightening torque of the screws

is 2 Nm.

4. Drillthethreeholes(6)formountingtheGATNET.LockBoltSet7100.

5. Drill a hole for the LED display in the locker door (7). The recommended

holediameteris10mm.

Note:AfrontlabelcanbeusedtocovertheLEDhole.Ifthecustomer

designs the label he must pay attention that a transparent field for the

LED light should be placed on the label.

6. Mounttheboltsetontothelockerdoorbyusingthreescrews.

Note: Use the right type and length of the screws according to the

type of locker material.

Attention: The max. allowed tightening torque of the screws

is 2 Nm.

7. Close the locker door to test, if the door can be closed easily and the

door shackle inserts into the opening in the GAT NET.Lock 7000.

50

.0 m

m

6.0

mm

94

.0 m

m

60

.1 m

m

1.0

mm

Mid

dle

of th

e op

enin

gfo

r th

e do

or s

hakl

e

Lock

er d

oor

3

6

6

3

3

3

3

74.0 mm17.0 mm

17.0 - 17.5 mm

2.4 mm10.1 mm14.6 mm

17.6 mm

25.1 mm

6.6

mm

1

2 4

8.0 mm

33

.6 m

m

82

mm

1

2

6

6

775

3

Locker door

Centre of rotation of hinge

min. 230 mm

Lock

er w

all

Lock

er w

all

4 www.gantner.comValid as from September 27th 2013 • Technical data subject to modifications without notice! DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

1. GATNET.Lock7000

2. GAT NET.Lock Bolt Set 7200

3. MountingscrewsforGATNET.Lock7000

4. Door shackle

5. Door contact

6. Mountingscrewsforboltset

7. LED position

8. Cut-out for GAT NET.Lock Bolt Set 7200

9. Cut-outforlabelcarrier

10. Labelcarrier

On the inside and outside walls of the

locker door cut-outs must be made in

order to mount the GAT NET.Lock Bolt Set

7200 and the label carrier. The mounting

procedure is described on the next page.

The measurements for the cut-outs are

shown in the figure to the left.

Mounting on Metallic Doors

Installation measures for GAT NET.Lock 7000 and Bolt Set

During the mounting, please pay particular attention to the following points:

- Thedoorthicknessmustbebetween18and26mm(seefigure).

- Whenthedoorispressedshut,thegapbetweentheboltset(2)andthe

frontoftheGATNET.Lock7000mustnotbeexceed0.5mm.Ideallythe

bolt set should touch the front of the lock.

- Themiddleofthedoorshackle(4)mustbe1mmhigherthanthemiddle

of the door shackle opening in the GAT NET.Lock 7000. This ensures

the door’s ability to close even if the door position is modified 3 mm

downwardsor1mmupwards(tolerance±2mm).

Cut-outs in the Locker Door

3

3

3

3

2

2

6

7

1

6

9

6

6

10

7

12311

7

3

3

4

5

1

Lock

er w

all

50

.0 m

m

6.0

mm

94

.0 m

m

1.0

mm

Lock

er d

oor

(out

side

wal

l)

Lock

er d

oor

(insi

de w

all)

Lock

er w

all

74.0 mm17.0 mm

17.0 - 17.5 mm

min. 18 mmmax. 26 mm

Inside of Locker

Locker Door(Front view without lable carrier)

Locker Door(Front view with lable carrier)

15.1 mm

32

.6 m

m

60

.1 m

m

Mid

dle

of th

e op

enin

gfo

r th

e do

or s

hakl

e

Lock

er w

all Locker Door

(Front view with lable carrier)

6

89

6

8

9

Lock

er w

all

LED

Lock bottom edge

Locker Door (Front view)

Cut

-Out

on

insi

de w

all

Cut

-Out

on

outs

ide

wal

l

Lock

bas

e

63.4

65.9

0.8 46.617.6

6.6

80.4 79.1

11.1

4 x holes for screws,Ø 3.6 mm, see step 7on page 5

All measures in mm.

83.6

Lock

er d

oor

(insi

de w

all)

Lock

er d

oor

(out

side

wal

l)

Inside of Locker

13.1

1.7

5www.gantner.comValid as from September 27th 2013 • Technical data subject to modifications without notice!

DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

Mounting procedure

Note: Before mounting all locks of the locker system a test installation of

at least one lock and final function check must be performed like

described below. Only if the tests are successful the rest of the

locks may be mounted in the same way.

1. Drillthe3holes(3)fortheGATNET.Lock7000intothelockerwall.

2. Plug-intheconnectioncable(seepage6).

3. MounttheGATNET.Lock7000with3screws(3)ontheinsidelocker

wall.

Note: Use the right screws according to the type of locker material.

Attention: The max. allowed tightening torque of the screws

is 2 Nm.

4. Ontheinnerwallofthelockerdoormakethecut-out(62.6x68mm)

for the GAT NET.Lock Bolt Set 7200.

5. Ontheinnerwallofthelockerdoordrillthe4holes(6)formounting

the GAT NET.Lock Bolt Set 7200.

6. Ontheouterwallofthelockerdoormakethecut-out(67.6x93.5mm)

for the label carrier.

7. Mount the bolt set onto the inside wall of the locker door by using 4

screws as shown in the figure on the previous page.

Note:OnlyuseTorxpan-headmetalscrews,Ø3.5mm,length9.5mm.

Attention: The max. allowed tightening torque of the screws

is 2 Nm.

8. Push the label carrier onto the outside wall of the locker door. The

label carrier will hold in place with the lashes on the label carrier. No

screwsarerequired.

9. Stickthefrontlabel(11)ontothelabelcarrier.

Note: A customer-specific front label can be used to cover the LED

hole. A transparent field should be placed on the label to show

the LED light.

10.Closethedoortotest,ifthelockerdoorcanbeclosedeasilyandifthe

door shackle inserts into the opening of the GAT NET.Lock 7000.

3

3

3

3

2

2

6

7

1

6

9

6

6

10

7

12311

7

3

3

4

5

1

Lock

er w

all

50

.0 m

m

6.0

mm

94

.0 m

m

1.0

mm

Lock

er d

oor

(out

side

wal

l)

Lock

er d

oor

(insi

de w

all)

Lock

er w

all

74.0 mm17.0 mm

17.0 - 17.5 mm

min. 18 mmmax. 26 mm

Inside of Locker

Locker Door(Front view without lable carrier)

Locker Door(Front view with lable carrier)

15.1 mm

32

.6 m

m

60

.1 m

m

Mid

dle

of th

e op

enin

gfo

r th

e do

or s

hakl

e

Lock

er w

all Locker Door

(Front view with lable carrier)

6 www.gantner.comValid as from September 27th 2013 • Technical data subject to modifications without notice! DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

Safety instructions

- Thisdevicemustbeinstalledbyqualifiedpersonnelonly.

- The applicable safety and accident prevention regulations

must be observed.

- Safety devices must not be removed.

- Please observe the technical data of the device specified

on the data sheet.

- The device must be disconnected from the power supply

prior to installation, assembly or dismantling.

Electrical Connection

Cable Outlets

Cut-out one of these outlets (1) in order to feed the cable out of the

housing.

Configuration

The configuration of the GAT NET.Lock 7000 and the controllers, where

the GAT NET.Lock 7000 is connected, is done via the GAT Relaxx PC

software. The configuration is described in the GAT NET.Lock 7000 and

the GAT Relaxx manuals.

GAT NET.Lock 7000 Back Side

1

1

1

1

1

Connection Cable

To connect the GAT NET.Lock 7000 to a GAT NET.Controller S 7000

usetheGATNET.LockCablewith4-pinMOLEXplugonbothends. It is

possible to connect 2 of these cables by using a GAT NET.Lock Connector

(see order information).

To connect a GAT NET.Lock 7000 only an original cable from

GANTNER Electronic GmbH may be used.

Power Supply and Signal Lines

DC power supply (see technical data) for unlocking and for the RFID

reading field.

Antenna Adjustment

The GAT NET.Lock 7000 can automatically adjust the RFID antenna. A

description can be found in the manual of the GAT NET.Lock 7000.