GasClam: The Past, Future and Present of Ground Gas Monitoring

Elliot Rosher, Product Specialist Manager

Page 2: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

Who are Shawcity? Shawcity Ltd: • Privately-owned company based in

Oxfordshire • Over 40 years’ experience in

Health & Safety • In-house Service and Calibration centre • Hire option for most applications • Specialise in Health and Safety,

Occupational Health and Environmental Monitoring

Page 3: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

Shawcity & The GasClam • Relationship with Ion Science and Shawcity • UK distributor for GasClam and Ion Science products • Large GasClam Hire Fleet for UK applications • On-going technical support and product training • Authorised GasClam Service and Calibration centre.

+ =

Page 4: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

• Continuous ground gas monitoring up to three weeks. • 5 point Gas Measurements (CH4, CO, CO2, VOC, H2S, O2) • Temperature, Borehole and Atmospheric Pressure • GasClam PC software to review data in graph formats

and adjust instrument settings • ATEX Approved • IP68 Rated • Discrete in ground monitoring • Reduces cost and time • 65,000 data points and set intervals

GasClam Technical Info

Page 5: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

GasClam Case Study The Client’s Application: • Herefordshire Council are

currently using GasClam used to monitor potential landfill gas migrating from a closed landfill site, which in 2002 was determined as ‘contaminated land’ under Part IIA of the Environmental Protection Act 1990.

Page 6: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

GasClam Case Study

Why choose GasClam and how is it used? • Site perimeter to monitor Methane,

Carbon Monoxide and VOCs • Portable, long-term solution to understand

gas levels exceeding the site boundary • Recording data points on an hourly basis • Every 28 days:

– Simple download of data for reporting – Simple maintenance:

Replacing filters and batteries.

Page 7: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

GasClam Case Study Benefits to customer from using the GasClam: • “Helps us to review whether the gas extraction

system is working efficiently” • “Assesses whether the landfill gas is

degenerating from the site” • “Shows the factors that can influence

gas migration e.g. barometric pressure” • “We have saved time and money

throughout the project”

“The four clams are an essential tool for the ongoing assessment of the closed landfill site”

Page 8: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

The Future of the GasClam?

Page 9: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

GasClam 2 - Added Benefits

• Longer Battery life offering 3 months monitoring • Option to add flow monitoring with the unit • Advanced power management system • External power source • New software

Page 10: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

Review of the GasClam

• Allows remote monitoring for long periods of time on 5 gas points (CO, CH4, H2S, O2 & VOCs)

• Easy to deploy and maintain throughout monitoring period

• Shows change of pressure readings in bore hole and atmospheric

• Allows users to download data and review in graph format with time and date

• Saves time & money.

Page 11: GasClam - environment-analyst.s3.amazonaws.com · - Ground Gas - Single & Multi Gas - Fixed Gas Systems - Gas Sensors - Sound & Noise - Vibration - Air Quality & Dust - Fit Testing

- Ground Gas - Single & Multi Gas - Fixed Gas Systems

- Gas Sensors - Sound & Noise - Vibration

- Air Quality & Dust - Fit Testing - Heat Stress

Thank you. Any questions?

Elliot Rosher

Product Specialist Manager Shawcity Ltd.