Gasmaster
Control panel for gas and fire monitoring
5/17/2018 Gas Master - slidepdf.com
http://slidepdf.com/reader/full/gas-master-55b07e8c53c55 2/4
Gasmaster is the flexible and simple-to-use solution wherever you need a self-contained control panel to monitor
gas or fire hazards.
It combines extensive features and outstanding performance to suit all applications. Gasmaster provides the
information you need at a glance via the comprehensive display, and all adjustments can be performed using the
buttons on the front panel. Gasmaster can operate ‘stand-alone’ or interface with any alarm devices and control
systems using a selection of outputs.
In short, Gasmaster is the flexible control panel you can trust.
Simple and convenientGasmaster has been designed for easy operation. All
gas levels are displayed simultaneously to enable full
system status checks at a glance.
All functions from day-to-day operation to re-calibration
can be carried out from the front panel, so routine
testing can be performed in a moment.
Gasmaster PC software enables re-configuration and
event log upload in an instant.
Installation and maintenance is also extremely
simple. Ample space is provided for cable glands andtermination of wiring. Gasmaster warns when calibration
is due, and all inputs and outputs can be quickly tested
using a simple button press.
Safe and reliable
There are two levels of alarm per channel as well as
common alarm and fault relays, which can be configured
to suit site requirements. An integral 85dB multi-tone
sounder is fitted as standard.
Relays can operate in ‘fail-safe’ mode, and all coils are
actively monitored so Gasmaster can warn if a relay
fails.
Battery back-up is provided as standard to ensure
continued protection even if the power fails.
Alarms and faults are recorded in an ‘event log’ which
can be accessed regularly to assess risks on site.
Flexible input and
output options
Gasmaster can monitor and control virtually any
combination of gas or fire detectors, and offers an array
of outputs as standard to enable simple integration with
any control equipment with minimum wiring.
Gasmaster provides relays, drives for audible/visual
alarms, 4-20mA or 1-5V outputs and RS-485 Modbus
communications for comprehensive monitoring and
control.
For convenience, Gasmaster has a remote inhibit and
remote reset facility to enable control from any point on
your site.
Level 1 alarms can be set to operate ‘silently’ so that
ventilation fans can be controlled without raising alarms.
Adaptable to your
needsThe LCD display can be set to read in many languages,
and provides detailed descriptions of alarms and
detector locations as well as system status.
Gasmaster is available in two versions to address the
needs of virtually any application:
Gasmaster 1: for one gas detector, fire zone or
Environmental Sampling Unit (contact Crowcon for
details)
Gasmaster 4: for one to four gas detectors, fire zonesor Environmental Sampling Units (contact Crowcon for
details)
Gasmaster
5/17/2018 Gas Master - slidepdf.com
http://slidepdf.com/reader/full/gas-master-55b07e8c53c55 3/4
Gasmaster 4
Gasmaster Accessories
AC/DC power options
plus internal battery
back-up.
4-20mA or
1-5V outputs per
channel
Relays for low and high alarm
for each channel, plus common
alarm and fault
RS-485 Modbus
communicationsEvent logging1
Alpha-numeric
scrolling display
which shows
comprehensive
system information
Large clear display
which shows
all gas levels
simultaneously
Ultra-bright alarm
indicator bar
System status
LED’s
Switches for all
system operation
and maintenance
functions
Industry-standard
gas detectors
Auxilliary Power Unit provides extended
back-up in the event of mains power
failure.
Accessory Enclosure allows connection of
mV Bridge type flammable gas detectors.
Remote inhibit
and reset switches
Dedicated audible/
visual alarm drives
Up to 20 fire/heat
detectors per zone
Sampling
Device control
for Crowcon’s
EnvironmentalSampling Unit
1 Event log access requires optional Communications Kit
5/17/2018 Gas Master - slidepdf.com
http://slidepdf.com/reader/full/gas-master-55b07e8c53c55 4/4
Gasmaster 1 Gasmaster 4
Size 288h x 278w x 110d (mm) 288h x 278w x 110d (mm)
Weight 4.5Kg 4.5Kg
Enclosure material Back-box: cast aluminium Back-box: cast aluminium
Front cover: fire-retardant ABS plastic Front cover: fire-retardant ABS plastic
Ingress protection IP54, IP66 optional IP54, IP66 optional
Power 100-240Vac 50-60Hz or 100-240Vac 50-60Hz or
20-30Vdc, 60W max. 20-30Vdc, 60W max
Battery back-up 1.2Ah batteries fitted internally 1.2Ah batteries fitted internally
Operating temperature -10oC to +50oC (14 to 122oF) -10oC to +50oC (14 to 122oF)
Humidity 0 to 95% RH non-condensing 0 to 95% RH non-condensing
Inputs: Gas One 2 or 3 wire 4-20mA gas detector (sink or One to four 2 or 3 wire 4-20mA gas detectors
source). Adaptor for mV bridge type detectors (sink or source). Adaptor for mV bridge type
available. detectors available.
Fire One loop of up to 20 conventional smoke/heat One to four loops of up to 20 conventional
detectors or manual call points, or one flame smoke/heat detectors or manual call points, or one to
detector (4-20mA or digital contact signal) four flame detectors (4-20mA or digital contact signal)
Environmental Sampling Unit For use with one Crowcon ESU For use with one to four Crowcon
sampling device ESU sampling devices
Remote inhibit Via normally open contact Via normally open contact
Remote reset Via normally open contact Via normally open contact
Outputs: Relays DPCO contacts rated Low alarm. High alarm. Fault. Alarm relays can be Low alarm and High alarm per channel plus
250Vac 8A (non-inductive load). set for rising or falling alarms. Hysteresis can be Common Low, High and Fault. Alarm relays can be
Relays can be set as energised or adjusted on low alarms set for rising or falling alarms. Hysteresis can be
de-energised, latching or adjusted on low alarms
non-latching, latching acceptable
Audible/visual 24Vdc 650mA max. drive 24Vdc 650mA max. drive
alarm drive (typically 2 devices max.) (typically 2 devices max.)
Analogue 4-20mA (current source, max. loop resistance 700Ω) 4-20mA for each channel (current source, max.
or 1-5Vdc (min. load 50 KΩ) loop resistance 700Ω) or 1-5Vdc (min. load 50 KΩ)
Digital communications RS-485 Modbus RTU for monitoring and control via RS-485 Modbus RTU for monitoring and control via
DCS/SCADA/PLC systems DCS/SCADA/PLC systems.
Communications port1 For PC configuration and event log upload For PC configuration and event log upload
Event logging1 Time-stamped log of up to 300 alarm, fault or system Time-stamped log of up to 300 alarm, fault or system
intervention activities intervention activities
Panel indication LCD back-lit display shows gas level LCD back-lit display shows gas level
(in ppb, ppm, % volume or % lel units), (in ppb, ppm, % volume or % lel units)
and scrolling alpha-numeric status indication. for all channels, and scrolling alpha-numeric status
LED’s for Alarm, Fault, Power and Warning. indication.
Integral 85dB sounder LED’s for Alarm, Fault, Power and Warning.
Integral 85dB sounder
Approvals EN 50270 (EMC) EN 50270 (EMC)
EN 61010-1 (Low voltage directive) EN 61010-1 (Low voltage directive)
P05007 Issue 5 02/07UK OfficeCrowcon Detection Instruments Ltd2 Blacklands Way
Abingdon Business Park AbingdonOxfordshire OX14 1DYUnited KingdomTel: +44 (0) 1235 557700Fax: +44 (0) 1235 557749Email: [email protected] Site: www.crowcon.com
USA OfficeCrowcon Detection Instruments Ltd21 Kenton Lands RoadErlanger Kentucky 41018-1845USATel: +1 859 957 1039 or
1-800-5-CROWCONFax: +1 859 957 1044Email: [email protected] Site: www.crowcon.com
Rotterdam OfficeCrowcon Detection Instruments LtdVlambloem 1293068JG, RotterdamNetherlandsTel: +31 10 421 1232Fax: +31 10 421 0542Email: [email protected] Site: www.crowcon.com
Singapore OfficeCrowcon Detection Instruments LtdBlock 194 Pandan Loop#06-20 Pantech Industrial ComplexSingapore 128383Tel: +65 6745 2936Fax: +65 6745 0467Email: [email protected] Site: www.crowcon.com
Gasmaster Specifications
Crowcon reserves the right to change the design or specification of these products without notice
1Event log access requires optional Communications Kit and communications port