gas fired, induced draft, cast iron water boiler · gas fired, induced draft, cast iron water...
TRANSCRIPT
Gas Fired, Induced Draft,Cast Iron Water Boiler
PVG™
• 85%AFUE
• Electronicignition
• EquippedwithIntelligentHydronicControl
• 70–280MBH(7sizes)
• Idealforinstallationswherechimney ventingisnotpossible,industry-standard tappinglocationspermiteaseofreplacement forthousandsofexistinginstallations
• Solid,reliable,American-madecastiron
• Lifetimelimitedwarranty
• Availableinselectmarkets
Intelligent Hydronic Control Features
• Combinesaquastat,relay,andignitionfunctionsintoasinglemodule
• Twocustomizableintegratedswitchingrelaysforeasyadditionofadditionalheatingzoneorindirectwaterheater
• Energysaving“thermalpurge”,whichworksbycirculatingresidualwarmwater(140°orabove)intheheatingsystembeforefiringtheboiler
• LEDdisplayforboilerstatusandtroublecodes
• Lowerreplacementcost
• Wiringharnessconnectorsdesignedtopreventmis-wiring
• Extensivelytestedandproveninthousandsofexistinginstallations
IntelligentHydronic Control
PVG: Technical Information
© 2014 U.S. Boiler Company, Inc. - Lancaster, PAPhone: 1-888-432-8887
www.usboiler.net
Form No. PL81401051001-5m sPrinted in the U.S.A
ASM
E
H
PVG Dimensions & Connections
Model
Dimensions (inches) Connections (inches) WaterContent (gal.)“A” “B” “C” Supply Return
Gas Valve
Relief Valve
PVG3 11.65 26.60 38.09 1-1/4 1-1/4 1/2 3/4 2PVG4 14.72 26.60 38.09 1-1/4 1-1/4 1/2 3/4 3PVG5 17.78 26.60 38.09 1-1/4 1-1/4 1/2 3/4 4PVG6 20.84 26.60 38.09 1-1/4 1-1/4 1/2 3/4 5PVG7 23.90 26.60 38.09 1-1/4 1-1/4 3/4 3/4 6PVG8 26.97 26.60 38.09 1-1/4 1-1/4 3/4 3/4 7PVG9 30.03 26.60 38.09 1-1/4 1-1/4 3/4 3/4 8
*Addsuffix“N”fornaturalgas,orsuffix“L”forLPgasmodels
PVG Ratings & Specifications
Model AFUE%Input
(MBH)
DOE HeatingCapacity(MBH)
Net AHRI (MBH)
Vent Size(Inches)
Approx. Shipping Weight. (lbs.)
PVG3 85.5 70 60 52 3 245PVG4 85.4 105 90 78 3 296PVG5 85.3 140 120 104 3 348PVG6 85.2 175 150 130 3 386PVG7 85.0 210 179 156 3 397PVG8 84.5 245 208 181 4 430PVG9 84.0 280 238 207 4 575
Standard Equipment • Insulatedsteeljacket• Heavygauge1”baseinsulation• IntelligentHydronicControl–Simpleself-diagnostic controlsystemwith3-digitreadoutforstatussettings anderrors• Step-openingredundantgasvalve• Stainlesssteelburnertubes• Stainlesssteelfluegasbaffles• Sparkignitionwithcontinuousretry• User-friendlywiringwith120VJ-box• Taco007circulatorwithpipingwithwiringharness• Castironsectionassembly• Differentialventpressureswitch• Boilerdrainvalve• Castironsupplymanifoldwithsafetyreliefvalvetapping• Ventconnectorterminal• Airinletterminal• Ventterminalforhorizontal/vertical(sidewall)venting
TM