gas combustion unit for lng fueled vessel*1. ch4:100% (as low calorific value 50 mj / kg) *2. gas...

2
When? Boil off gas treatment process in vessels IGF code Completely compliant Environmentally- conscious and safe IGC code If the engine cannot completely consume the gas, the boil off gas will need to be treated in order to adjust the pressure inside the tank The release of combustible gases into the atmosphere is prohibited under the IGF code* 1 . * 1. International Code Of Safety For Ships Using Gases Or Other Low-Flash Point Fuels LNG tank pressure adjustment MECS-GCU helps to decrease your environmental burden Boil off gas becomes mixed with inert gas inside pipes, and must be treated when bunkering Inert gas treatment during LNG bunkering Gas let out from the tank during initial bunkering, when docking, or when performing maintenance work on the tank must be treated LNG tank cooling down / gas-freeing "Methane" is a major component of LNG (liquefied natural gas) fuel and has a global warming potential 25 times that of carbon dioxide! VOLCANO Gas Combustion Unit ( GCU ) features 小型船舶にも 設置可 どんな比率の ガスも燃焼 ガス温度が 低くても燃焼 広がる 対象船舶 低ランニング コスト Can be installed even in small vessels Combusts gas of any ratio Combusts even low-temperature gas Compatible with a wide range of vessels Low running cost Has already been successfully installed in LNG fuel tug-boats Supports gas at 0°C or even -150°C Capable of treatment up to inert gas 100% (Gas/Oil simultaneous mixed combustion) Consumes less power during operation than reliquification Can be used in many types of projects, such as installed on tug-boats, used for bunkering vessels, or as possible backups for other treatment devices CH4 CH4 CH4 Gas valve unit N2 gas LNG Buffer tank Vaporizer LNG tank MECS-GCU Main engine Generator Boiler, etc. 3 2 1 3 2 1 * An example only Gas Combustion Unit for LNG Fueled Vessel LNG fueled vessels require that boil off gas be treated safely and appropriately. The VOLCANO "MECS-GCU" gas combustion unit combustion treats boil off gas to help eliminate the release of methane gas into the atmosphere.

Upload: others

Post on 20-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gas Combustion Unit for LNG Fueled Vessel*1. CH4:100% (as low calorific value 50 MJ / kg) *2. Gas supply pressure at gas valve unit inlet *3."Free flow" is when gas is supplied at

When? Boil off gas treatment process in vessels

IGF code Completely compliant

Environmentally-conscious and safe

IGC code

If the engine cannot completely consume the gas,the boil off gas will need to be treated in order toadjust the pressure inside the tank

The release of combustiblegases into the atmosphereis prohibited under theIGF code*1.

*1. International Code Of Safety For Ships Using Gases Or Other Low-Flash Point Fuels

LNG tank pressure adjustment

MECS-GCU helps to decreaseyour environmental burden

Boil off gas becomes mixed with inert gas inside pipes,and must be treated when bunkering

Inert gas treatment during LNG bunkering

Gas let out from the tank during initial bunkering,when docking, or when performing maintenance workon the tank must be treated

LNG tank cooling down / gas-freeing

"Methane" is a major component ofLNG (liquefied natural gas) fuel andhas a global warming potential 25times that of carbon dioxide!

VOLCANO Gas Combustion Unit (GCU) features小型船舶にも設置可 どんな比率のガスも燃焼 ガス温度が低くても燃焼 広がる対象船舶 低ランニングコストCan be installedeven in small

vessels

Combusts gasof any ratio

Combusts evenlow-temperature

gas

Compatible witha wide range of

vessels

Lowrunning cost

Has already beensuccessfully installedin LNG fuel tug-boats

Supports gas at0°C or even -150°C

Capable of treatmentup to inert gas 100%(Gas/Oil simultaneousmixed combustion)

Consumes less powerduring operation thanreliquification

Can be used in many typesof projects, such as installedon tug-boats, used for bunkering vessels, or aspossible backups for othertreatment devices

CH4 CH4

CH4

Gas valve unit

N2 gasLNG

Buffer tank

VaporizerLNG tank

MECS-GCU

•Main engine•Generator•Boiler, etc.

3

2

1

3

2

1

* An example only

Gas Combustion Unit for LNG Fueled Vessel

LNG fueled vessels require that boil off gas be treated safely and appropriately. The VOLCANO "MECS-GCU" gas combustion unit combustion treats boil off gas to help eliminate the release of methane gas into the atmosphere.

Page 2: Gas Combustion Unit for LNG Fueled Vessel*1. CH4:100% (as low calorific value 50 MJ / kg) *2. Gas supply pressure at gas valve unit inlet *3."Free flow" is when gas is supplied at

*1. CH4:100% (as low calorific value 50 MJ / kg) *2. Gas supply pressure at gas valve unit inlet*3. "Free flow" is when gas is supplied at the tank pressure without pressurizing boil off gas*4. Vertical type hull dimensions *5. Dimensions and weight values are for reference only

* Not just LNG gas fuel! Supports various kinds of gas fuels.

Also supports remote control panels

Compatible with classification rules

Also supports redundancy

•Lower operation cost than gas treatment methods that consume power (such as reliquification)•Gas/Oil simultaneous mixed combustion using diesel oil provides stable combustion

GCU advantages

•All types of gas fueled vessels (from tug-boats to VLCC class vessels)

•Gas fueled bunkering vessels, etc.

Possible vessel types for installation

VOLCANO solution for LNG fueled vessel issues

VOLCANO Co., Ltd. provides products for LNG as fuel and solution for LNG utilization, based on our experiences on Gas/Oil simul-taneous mixed combustion DF burner for Marine-use, Gas burner for Industrial-use and Ultra-low NOx burner for Industrial-use.

VOLCANO CombustionTest Site responsible forverification testingduring the developmentof MECS-GCU

Specifications and overview

Configuration

TYPE MECS-G25

MECS-G50

MECS-G100

MECS-G150

MECS-G200

MECS-G300V

MECS-G500V

MECS-G750V

MECS-G1000V

kg/h

MPaG

mm

mm

mm

kg

25

2,530

926

2,015

600

50

3,200

850

2,300

1,300

100

4,000

1,200

3,100

2,000

150

4,500

1,300

3,500

2,700

200

From free flow to 1.0

5,000

1,500

4,000

3,500

300

5,100

4,200

500

6,100

4,650

750

7,200

5,800

1000

7,500

6,700

φ2,400 φ2,500 φ2,700 φ2,900

Combustion rate

Gas pressure

Weight (a b)

Length

Width

Height

Dimensions

*1

*3

*4 *4 *4 *4

*2

*5

*5

Combust and treat Boil Off Gas

Combustion Engineering Expert

Use/treat Boil Off Gas as fuel

VOLCANO Gas Combustion Unit (MECS-GCU)

VOLCANO Gas/Oil simultaneous mixed combustionDF burners for boiler

Considering using gas fuel even in your boilers? Our "Vignis" and "SFFG-II" Gas/Oilsimultaneous mixed combustion DF burners are capable of completely combusting unburnt gas.

Pilot burnerpump unit

MECS-GCU

Solenoid valveboard

Gas valve unit Control panel

FD fan forfurnacecooling-air

Remote controlpanel

Pilot burner

Flame eye

FD fan forcombustion-air

20190701-01MECS-G01EE

Gas Combustion Unit forLNG Fueled Vessel