gas boilers flue systems - heating spares ltd · gas boilers technical guide the best combination...
TRANSCRIPT
Supplied By www.heating spares.co Tel. 0161 620 6677
Flueing options andaccessories
Multiple flue options forStandard andCondensing Boilers
GAS BOILERS
w w w. c h a f f o t e a u x . c o . u k
Flueing options andaccessories
Multiple flue options forStandard andCondensing Boilers
FLUE SYSTEMS
Supplied By www.heating spares.co Tel. 0161 620 66772 - C&M - Flueing options and accessories
3
4
2
1
G A S B O I L E R S
www.chaffoteaux.co.uk
Technical GuideThe best combination of comfort and economy
Chaffoteaux & Maury wall-hung gas appliances offer great flexibility in flueingarrangements, to accommodate all installation requirements. This technicalguide will help you to select the correct flue and components, for the locationof the boiler within a property.
1 - Standard Horizontal
The standard flue canrotate through a full 360˚allowing the greatestflexibility in siting.
2 - Raised Horizontal
Using a vertical adaptortogether with standard flueextensions it is possible toextend the overall length ofa standard flue and stillterminate horizontally.
3 - Vertical
For situations where it isnecessary to terminate theflue vertically through atiled or flat roof.
4 - Twin Pipe (Biflux)
Suitable for applicationswhere the appliance iseither sited further from asuitable external wall orwhere building obstructionsdo not allow conventionalhorizontal or vertical flueingarrangements.
Supplied By www.heating spares.co Tel. 0161 620 6677
Flue Terminal Positions
www.chaffoteaux.co.uk
In accordance with BS 5440-1:2000
C&M - Flueing options and accessories - 3
G A S B O I L E R S
A
B
DEH
I
E
M
I
N
P
P
C
H
LF
JK
Terminal Position mmA Directly below an opening, air brick, opening windows, etc 300B Above an opening, air brick, opening windows, etc 300C Horizontally to an opening, air brick, opening windows, etc 300D Below gutters, soil pipes or drain pipes 75E Below eaves 200F Below balconies or car port roof 200G From vertical drain or soil pipe 150H From an internal or external corner 300I Above ground roof or balcony level 300J From a surface facing the terminal 600K From a terminal facing the terminal 1200L From an opening in the car port (e.g. door, window) into the dwelling 1200M Vertically from a terminal on the same wall 1500N Horizontally from a terminal in the same wall 300P Fixed by use of terminal and matched flashing plate -
Installation Conditions
C&M - Flueing options and accessories - 3
Supplied By www.heating spares.co Tel. 0161 620 66774 - C&M - Flueing options and accessories
Flue Types
C&M wall-hung appliances can be fitted up to 15metres from an outside wall using 80/125mm fluecomponents (4 metres using 60/100mm fluecomponents).
As long as the flue terminates horizontally, the mainlength of the flue can be vertical.
Uses standard straight flue extensions and bends.
With a special rubber sealing ring the flue can beinstalled and sealed externally at high levelswithout requiring access to the outside (60/100mmonly).
Unobtrusive terminal.
Simply add bends and straight extensions asrequired to complete the installation (60/100mmonly).
For 80/125mm use the 80/125 vertical adaptor.
Full range of accessories available.
Horizontal incorporating2 x 45˚ bends
Horizontal incorporating45˚ or 90˚ bend
Raised Horizontal,side exit
Raised Horizontal incorporating2 x 90˚ bend and straightextensions
C&M wall-hung appliances can be fitted up to 4metres from an outside wall using the standardhorizontal flue kit.
Full 360˚ rotation of the flue allows the greatestflexibility.
The optional 45˚ and 90˚ bends make the systemideal for boiler changes.
With a special rubber sealing ring the flue can beinstalled and sealed externally at high levelswithout requiring access to the outside.
Unobtrusive terminal.
The standard kit contains all that is necessary for abasic installation.
Full range of accessories available.
4 - C&M - Flueing options and accessories
Raised horizontal
Standard horizontal
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 5
G A S B O I L E R S
Flue can terminate vertically up to 16 metres awayfrom the boiler using the 80/125mm Vertical FlueKit (5 metres using the 60/100mm Vertical Flue Kit).
Removes the need to fit the boiler near an outsidewall.
A multitude of accessories make a very adaptableand flexible flue system.
Vertical terminals for flat, sloping, tiled or slatedroofs available.
Terminals and Flashings available in terracottafinish to special order.
Vertical Flue incorporating1 x 90˚ bend and 2 x 45˚bends
Vertical Flue incorporating2 x 90˚ bends
The ultimate in flexibility.
C&M wall-hung boilers can be fitted with upto 30 metres of Biflux flue.
Can terminate on flat, sloping, slated or tiledroofs.
Vertical, horizontal and even separateterminals are available.
Full range of accessories available.
Twin Pipe Flue withsingle vertical terminal
C&M - Flueing options and accessories - 5
Twin Pipe (Biflux)
Vertical
Supplied By www.heating spares.co Tel. 0161 620 66776 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
System ConfigurationsList of Contents
Standard Efficiency
Coaxial 60/100 - Standard/Raised Horizontal page 10
Coaxial 60/100 - Vertical page 11
Coaxial 80/125 - Raised Horizontal page 13
Coaxial 80/125 - Vertical page 15
Twin Pipe 80 - Horizontal page 17
Twin Pipe 80 - Vertical page 18
High Efficiency CondensingCoaxial 60/100 - Standard/Raised Horizontal page 21
Coaxial 60/100 - Vertical page 22
Coaxial 80/125 - Raised Horizontal page 24
Coaxial 80/125 - Vertical page 25
Twin Pipe 80 - Horizontal page 27
Twin Pipe 80 - Vertical page 29
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 7
G A S B O I L E R S
Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).Figures marked with * relate to the 30 FF model.
MX2 24 FF & 30 FF
Standard Efficiency -Which flue options do you need?
Supplied By www.heating spares.co Tel. 0161 620 66778 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
Britony Combi SE, Britony System II,Britony System II Plus & Calydra Comfort
Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).Figures marked with * relate to 100 models.
Standard Efficiency -Which flue options do you need?
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 9
G A S B O I L E R S
Calydra Green & Centora Green
Lengths quoted are maximum straight length equivalents(including bends) (see table for full SLE lengths details).
High Efficiency Condensing -Which flue options do you need?
www.chaffoteaux.co.uk
Supplied By www.heating spares.co Tel. 0161 620 6677
Air/exhaust systems with coaxial tubes Ø 60/100 (horizontal)
10 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.ukwww.chaffoteaux.co.uk
Standard Efficiency - Coaxial
TELESCOPIC HORIZONTAL COAXIAL KIT600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
STANDARD HORIZONTAL COAXIAL KIT1000mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW750mm coaxial kit complete with terminalPacket with gaskets and fixing screwsCover plate in EPDM
90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws
1
1
1
1
707067
705958
705783
705787
0.75m
1.0m
0.75m
0.8m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 11
G A S B O I L E R S
C&M - Flueing options and accessories - 11
Standard Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (horizontal)
Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION160mm coaxial extension with centering springPacket with gaskets and fixing screws
2
1
1
1
705788
705786
705790
705812
0.5m
1.0m
0.5m
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)
Standard Efficiency - Coaxial
12 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL STUB WITH CONDENSATE TRAP160mm coaxial stub with condensate discharge connectionPacket with gaskets and fixing screws
STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws
STANDARD VERTICAL FLUE (TERRACOTTA)
LEAD FLASHING BASE CAP (BLACK)Lead pitched roof flashing with collar
LEAD FLASHING BASE CAP (TERRACOTTA)
2
1
1
1
1
1
1
1
1
705788
705786
705790
705812
705792
705764
705765
705781
705724
0.5m
1.0m
0.5m
0.2m
0.3m
1.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
Standard Efficiency - Coaxial
ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws
HORIZONTAL TERMINAL600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
1
1
706014
61020448 0.6m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
VENT BASE CAP FOR FLAT ROOF (BLACK) 1 704830
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 13
G A S B O I L E R S
Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)
Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)
Supplied By www.heating spares.co Tel. 0161 620 6677
90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
COAXIAL EXTENSION2000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screw
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws
1
1
1
1
1
1
61304857
61304854
61304856
61304853
61304852
61304851
2.0m
1.0m
2.0m
1.0m
0.5m
0.3m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
14 - C&M - Flueing options and accessories
G A S B O I L E R S
Standard Efficiency - Coaxial
www.chaffoteaux.co.uk
Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)
Supplied By www.heating spares.co Tel. 0161 620 6677
ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
COAXIAL EXTENSION2000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screw
1
1
1
1
706014
61304854
61304856
61304853
1.0m
2.0m
1.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 15
G A S B O I L E R S
Standard Efficiency - Coaxial
Supplied By www.heating spares.co Tel. 0161 620 667716 - C&M - Flueing options and accessories
www.chaffoteaux.co.uk
Standard Efficiency - Coaxial
G A S B O I L E R S
Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION (TELESCOPIC)50-300mm telescopic coaxial extension with centering springPacket with gaskets and fixing screws
VERTICAL TERMINAL (BLACK) (80/125)Vertical flue kit 80/125
VERTICAL TERMINAL (TERRACOTTA) (80/125)
CONDENSATE TRAPCondense trap with drain point(for use with flues over 5 metres)
LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)
VENT BASE CAP FOR FLAT ROOF (BLACK)
1
1
1
1
1
1
1
11111
1
6130485210110
61304851
61304855
61304849
61304850
61010904
61017921
6101792261017923610084606100846161008462
60077757
0.5m
0.2m
0.3m
1.0m
1.0m
0.9m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
Air/exhaust systems with separate tubes Ø 80 (horizontal)
C&M - Flueing options and accessories - 17
G A S B O I L E R S
Standard Efficiency - Twin Pipe
TWIN PIPE FLUE KITAdaptor 60/80 d 100 for connection to boilerPacket with gaskets and fixing screwsN° 2 90° elbowsN° 2 pipes L1000 MFAir intake terminal
90° MF ELBOW (Ø80)90° elbow in aluminium (white)
90° MF ELBOW (Ø80)
45° MF ELBOW (Ø80)45° elbow in aluminium (white)
PIPE - 2000 mm (Ø80)Pipe L2000 MF in aluminium (white)
1
2
20
2
1
706026
705758
705759
705760
706279
1.3 m
1.0 m
2.0 m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 667718 - C&M - Flueing options and accessories
www.chaffoteaux.co.uk
G A S B O I L E R S
Air/exhaust systems with separate tubes Ø 80 (horizontal)
Air/exhaust systems with separate tubes Ø 80 (vertical)
Standard Efficiency - Twin Pipe
PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)
PIPE - 1000 mm (Ø80)
PIPE - 500 mm (Ø80)Pipe L500 MF in aluminium (white)
INTAKE VENT CAPAir intake Ø80 (plasticl)Fixing screws
STAINLESS STEEL EXHAUST VENT CAPExhaust terminal Ø80 (stainless steel)Fixing screws
1
10
1
1
1
705761
705762
705770
704738
705113
1.0 m
0.5m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
Air/exhaust systems with separate tubes Ø 80 (vertical)
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 19
G A S B O I L E R S
Standard Efficiency - Twin Pipe
Adaptor (Ø60/80) FOR TWIN PIPE SYSTEMAdaptor Ø60/80 with Ø100 connection to boilerPacket with gaskets and fixing screws
STUB (Ø80) WITH CONDENSATE COLLECTORPipe L85 MF in aluminium (white) with condensate drain
LEAD FLASHING BASE CAP (BLACK)Lead pitched roof flashing with collar
LEAD FLASHING BASE CAP (TERRACOTTA)
VENT BASE CAP FOR FLAT ROOF (BLACK)
VENT CAP (Ø80) FOR VERTICAL TERMINATIONTerminal Ø80 for flat roofs (black)Fixing screws
PIPE REDUCER (Ø118/80)Adaptor for vertical terminal
STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws
STANDARD VERTICAL FLUE (RED)
1
1
1
1
1
1
1
1
705757
705798
705781
705724
704830
705160
707166
705764
705765
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 667720 - C&M - Flueing options and accessories
www.chaffoteaux.co.uk
Air/exhaust systems with separate tubes Ø 80 (special componnets)
G A S B O I L E R S
Standard Efficiency - Twin Pipe
WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs
PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet
COVER PLATE (Ø80)EPDM cover plate
ADAPTOR (Ø80) FOR INSULATED PIPESAdaptor Ø80 for connection insulated exhaust pipescomplete with fixing screws
INSULATED PIPE L 1000Pipe Ø80/100 L 1000 insulatedPacket with gaskets and fixing screws
90° INSULATED ELBOW (Ø80)90° insulated elbow Ø80/100 Packet with gaskets and fixing screws
45° INSULATED ELBOW (Ø80)45° insulated elbow Ø80/100 Packet with gaskets and fixing screw
3
1
2
1
1
1
1
705778
705767
705784
705769
705771
705772
705773
10m
0.2m
1m
1.3m
1m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 21
G A S B O I L E R S
High Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (horizontal)
STANDARD HORIZONTAL COAXIAL KIT1000mm coaxial kit AL/PP complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
STANDARD HORIZONTAL COAXIAL KIT WITHOUT ELBOW600mm coaxial kit AL/PP complete with terminalPacket with gaskets and fixing screwsCover plate in EPDM
90° COAXIAL ELBOW90° coaxial elbow AL/PPPacket with gaskets and fixing screws
45° COAXIAL ELBOW45° coaxial elbow AL/PPPacket with gaskets and fixing screws
1
1
1
2
61309947
61310156
61309942
61309943
1.0 m
0.75 m
0.8 m
0.5 m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
G A S B O I L E R S
www.chaffoteaux.co.uk
Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)
Air/exhaust systems with coaxial tubes Ø 60/100 (vertical)
High Efficiency - Coaxial
22 - C&M - Flueing options and accessories
COAXIAL EXTENSION 1000 mmCoaxial extension 1000mm (Ø60/100)with centering spring
COAXIAL EXTENSION 500 mmCoaxial extension 500mm (Ø60/100)with centering spring
COAXIAL EXTENSION 250 mmCoaxial extension 250mm (Ø60/100)with centering spring
WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs
1
1
1
3
61309946
61309945
61309944
705778
1.0 m
0.5m
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 23
G A S B O I L E R S
High Efficiency - CoaxialAir/exhaust systems with coaxial tubes Ø 60/100 (vertical)
STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws
STANDARD VERTICAL FLUE (TERRACOTTA)
LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)
VENT CAP FOR FLAT ROOF (BLACK)
COAXIAL EXTENSION 1000 mmCoaxial extension 1000mm (Ø60 M/F) AL/PPwith centering spring
COAXIAL EXTENSION 500 mmCoaxial extension 500mm (Ø60/100 M/F) AL/PPwith centering spring
COAXIAL EXTENSION 250 mmCoaxial extension 250mm (Ø60/100 M/F) AL/PPwith centering spring
1
1
1
11111
1
1
1
1
61310342
61310343
61017921
6101792261017923610084606100846161008462
60077757
61309946
61309945
61309944
1.0m
1.0m
1.0m
0.5m
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 667724 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.ukwww.chaffoteaux.co.uk
Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)
High Efficiency - Coaxial
ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws
HORIZONTAL TERMINAL600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
90° COAXIAL ELBOW90° coaxial elbowPacket with gaskets and fixing screws
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
1
1
1
1
61309663
61309494
61309165
61309164
0.75m
2.0m
1.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
High Efficiency - Coaxial
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 25
G A S B O I L E R S
Air/exhaust systems with coaxial tubes Ø 80/125 (raised horizontal)
Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)
COAXIAL EXTENSION1500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION250mm oaxial extension with centering springPacket with gaskets and fixing screws
1
1
1
1
61309167
61309166
61309169
61309168
1.5m
1.0m
0.5m
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 667726 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)
ADAPTOR 60/100 - 80/125Conical adaptor to use 80/125 coaxial flue systemPacket with gaskets and fixing screws
45° COAXIAL ELBOW45° coaxial elbowPacket with gaskets and fixing screws
COAXIAL EXTENSION1500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION1000mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION500mm coaxial extension with centering springPacket with gaskets and fixing screws
COAXIAL EXTENSION250mm coaxial extension with centering springPacket with gaskets and fixing screws
VERTICAL TERMINAL (BLACK)600mm coaxial kit complete with 90° elbow and terminalPacket with gaskets and fixing screwsCover plate in EPDM
VERTICAL TERMINAL (TERRACOTTA))
1
1
1
1
1
1
1
1
61309663
61309164
61309167
61309166
61309169
61309168
61309163
61310344
1.0m
1.5m
1.0m
0.5m
0.2m
1.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
High Efficiency - Coaxial
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 27
G A S B O I L E R S
Air/exhaust systems with coaxial tubes Ø 80/125 (vertical)
Air/exhaust systems with separate tubes Ø 80 (horizontal)
High Efficiency - Coaxial
LEAD FLASHING BASE CAP (BLACK) (5/25O)Lead pitched roof flashing with collarLEAD FLASHING BASE CAP (BLACK) (25/45O)LEAD FLASHING BASE CAP (BLACK) (35/55O)LEAD FLASHING BASE CAP (TERRACOTTA) (5/25O)LEAD FLASHING BASE CAP (TERRACOTTA) (25/45O)LEAD FLASHING BASE CAP (TERRACOTTA) (35/55O)
VENT BASE CAP FOR FLAT ROOF (BLACK)
1
11111
1
61017921
6101792261017923610084606100846161008462
60077757
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 667728 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
Air/exhaust systems with separate tubes Ø 80 (horizontal)
High Efficiency - Twin Pipe
Adaptor (Ø60/80) FOR TWIN PIPE SYSTEMAdaptor Ø60/80 with Ø100 connection to boilerPacket with gaskets and fixing screws
90° MF ELBOW (Ø80)90° elbow in aluminium (white)
45° MF ELBOW (Ø80)45° elbow in aluminium (white)
PIPE - 1500 mm (Ø80)Pipe L1500 MF in aluminium (white)
PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)
PIPE - 500 mm (Ø80)Pipe L500 MF in aluminium (white)
PIPE - 250 mm (Ø80)Pipe L250 MF in aluminium (white)
1
2
1
1
1
1
1
61309715
61310174
61310173
61310170
61310169
61310171
61310172
1.3m
1.0m
1.5m
1.0m
0.5m
0.2m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 29
G A S B O I L E R S
Air/exhaust systems with separate tubes Ø 80 (horizontal)
High Efficiency - Twin Pipe
HORIZONTAL TERMINALSExhaust/intake terminals (stainless steel)1000mm Ø80 pipe exhuast1000mm Ø80 pipe intakeEPDM cover plate
1 61310345 2.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Air/exhaust systems with separate tubes Ø 80 (vertical)
Supplied By www.heating spares.co Tel. 0161 620 667730 - C&M - Flueing options and accessories
G A S B O I L E R S
www.chaffoteaux.co.uk
High Efficiency - Twin Pipe
Air/exhaust systems with separate tubes Ø 80 (special components)
COVER PLATE (Ø80)EPDM cover plate
WALL BRACKET KITWall fixing bracket Ø80-120Complete with plugs
1
1
705784
705778
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Air/exhaust systems with separate tubes Ø 80 (vertical)
PIPE BRIDGE (Ø80) Pipe bridge with Ø80/80 M/M inlet and Ø100 M outlet
45° MF ELBOW (Ø80)45° elbow in aluminium (white)
PIPE - 1000 mm (Ø80)Pipe L1000 MF in aluminium (white)
STANDARD VERTICAL FLUE (BLACK)Vertical flue kit 80/125 complete with 60/100 conical adaptorPacket with gaskets and fixing screws
1
2
1
1
61309715
61310173
61310169
61310168
10m
1.0m
1.0m
SCHEME DESCRIPTION OF COMPONENTS QTY CODE SLE
Supplied By www.heating spares.co Tel. 0161 620 6677
www.chaffoteaux.co.uk
C&M - Flueing options and accessories - 31
G A S B O I L E R S
Notes
Supplied By www.heating spares.co Tel. 0161 620 6677
w w w. c h a f f o t e a u x . c o . u k
MTS Building, Hughenden Avenue,High Wycombe, Bucks HP13 5FTTel: 01494 755600Fax: 01494 459775Technical Suppor t Help Line: 01494 539579
MTS (GB) Limited
In th
e in
tere
sts
of o
ur c
usto
mer
s, M
TS (G
B) L
imite
d is
con
tinua
lly d
evel
opin
g th
ese
prod
ucts
to im
prov
e bo
th p
erfo
rman
ce a
nd d
esig
n. W
e th
eref
ore
rese
rve
the
right
to c
hang
esp
ecifi
catio
n w
ithou
t prio
r not
ice.
Thi
s br
ochu
re is
acc
urat
e at
the
date
of p
rintin
g. C
onsu
mer
sta
tuto
ry ri
ghts
are
not
affe
cted
.M
onth
& Y
ear P
rinte
d by
Var
io P
ress