galaxy sq-270 sq-27… · 4 gal/min (1 bar = 4 gal/min) 0.5 - 5 bar 2.5 technical features....
TRANSCRIPT
Aquaticausa.comAquaticabath.caE: [email protected]
Installation & Care Manual
Built-In Shower Head
USA / Canada
Galaxy SQ-270
Aquaticausa.comAquaticabath.caE: [email protected]
Galaxy SQ-270Built-In Shower Head
10.6"
9.4"
Ø 0.2"
G1/2
0.7"
2.4"
Ø 1.6"
25° 25°
9.6"
Ø 9.4"
WIRE WITHMALE CONNECTOR
SHOWERHEAD
POWER SUPPLY
ARTICULATED CONNECTION
16'-5"
4 SCREWS FIXING
POWER SUPPLY
4.6"
2'
1.4"
INPUT: ~ 100/240 V AC~ 50/60 Hz 0.55 A
OUTPUT: 12 V 1.67 A 20W
2'
PARTS LIST
Galaxy SQ-270Built-In Shower Head
Pressure required: ............................................
Limited flow rate: water consuntion ..................
Pipes connection: .............................................G 1/2"
Maximum absorbed power: ..............................MAX 9 Watt
Power supply: .................................................. INPUT: ~ 100/240 V AC
~ 50/60 Hz 0.55 A
OUTPUT: 12 V 1.67 A - 20W
Pressure [bar]
Flo
w r
ate
[gal/m
in]
FLOW RESTRICTOR WORKING
SCHEME RELATED TO WATER PRESSURE
0.0 1.0 2.0 3.0 4.0 5.0 6.00.00
1.00
2.00
3.00
4.00
5.00
No. of samples 2
[bar] 0.5 0.7 1.0 1.5 2.0 2.5 4.0 6.0
[gal/min] 3.01 3.38 3.64 3.77 3.8 3.84 3.97 4.03
0.5 1.5
ELECTRICAL SAFETY
- Installation must be performed by qualified and/or
trained personnel.
The company declines all responsibility in the case
that installation is performed by personnel that is not
trained and/or qualified to carry out installation of this
product.
- The responsibility for the choice of materials in
relation to their utilisation, the correct execution of
the work, the verification of the plant system to which
the device will be connected as well as its suitability
to guarantee safety, are the responsibility of the
installer.
-The power supply plant must be efficient and
conform to the legal provisions and to specific
national regulations.
For connection to the electrical mains, a single pole breaker switch must be installed, to be placed in an area that
respects safety provisions for bathroom areas.
-This single pole, normalised breaker switch must guarantee an opening of the contacts of at least 3 mm, and be
suitable for voltage of 220-240V and current up to 16 A.
- In bathrooms, the installation of electrical devices and equipment, such as switches, outlets, etc., must be in
adherence to the law and the regulations of each country. In particular no electrical installation may be placed in
the area directly adjacent to the shower stall for a distance of at least 2' and a height of 7'-5".
- The power supply electrical system must have a differential switch connected to it.
- Any damages caused by the lack of observance of the legal and regulatory provisions as well as what is indicated
in the instruction sheet will be the responsibility of the installer.
4 gal/min (1 bar = 4 gal/min)
0.5 - 5 bar
2.5
TECHNICAL FEATURES
Aquaticausa.comAquaticabath.caE: [email protected]
Galaxy SQ-270Built-In Shower Head
min. 2'
A
min
. 7.4
'
Input current:
~ 100/240 V AC
~ 50/60 Hz 0.55 A
1/2" F
connection
Electrical
wire tube
B
=12 V DC
A = BOX FOR POWER SUPPLY
(not included)
- minimum sizes 6"x3.9"x2.7"
- see gewiss model art. GW48004
B = BOX FOR SWITCH (not included)
See the next sheet for this node
min. 2'
INSTALLATION SEQUENCE
Galaxy SQ-270Built-In Shower Head
- Never put the (~100/240 V) power supply input wires together in the same conduit pipe with the (=12 V) power
supply output wires that are then to be connected to the shower head wires.
Clamp
Wire connection
- 500 cm (included) LED wire connection
- 600 cm (included)
Water inlet
LED electricalcable
Switch to turn LED on and off
Ceiling Tube(Not included)
=12 V DC
Power Supply:
INPUT: ~ 100/240 V AC
~ 50/60 Hz 0.55 A
OUTPUT: 12 V 1.67 A 20W
=12 V DC
Input current:
~ 100/240 V AC
~ 50/60 Hz 0.55 A
Connectors
ATTENTION !
INSTALLATION SEQUENCE continued
Aquaticausa.comAquaticabath.caE: [email protected]
Galaxy SQ-270Built-In Shower Head
a
5/6"
ba
PipeG1/2" F
3
1 1/4"
a
b
b
3/32"
a
Not included
Electrical cableconduit tube
ATTENTION:
- Before attaching the electrical power lines, check and verify the security of
the connections and the operation of the shower head.
- The ATTACHMENT of the SHOWER HEAD PANEL to the drop-ceiling
panels must guarantee the mechanical solidity of the shower head itself.
Attachment is performed by way of screws that are not supplied.It is
necessary to provide for an opening in the drop-ceiling panels, near the
shower head, which may be used, in the event of maintenance necessities,
access to the area above the drop-ceiling itself.
Electric wire
Screws fixing
Not included
1 2
4
INSTALLATION SEQUENCE continued
Galaxy SQ-270Built-In Shower Head
NOZZLES REPLACEMENT
Sylicon antilimestone
nozzles
The correct cleaning of the showerhead has to be done with water and
soap, rinsed and dried with a doeskin or a soft cloth. Absolutely do not use
alcohol, solvents, solid or liquid containing corrosive or acid substances
(hydrochloric, formic, acetic and phosphoric acid), synthetic fibres, cloths,
abrasive sponges and plugs with metallic thread, because they could
irreversibly alter the treated surfaces.
Our devices do not need any particular maintenance with the exception of
the periodic cleaning of the rubber part (nozzles) of the shower head, that
they
may become locked by formations of limestone just rub with your finger to
remove the limestone.
ATTENTION: periodically check the niples, as an excess of dirt in them
may generate extra pressure inside the shower head compromising the
operation.
a b
c
1 2
3
A
B
C
CLEANING AND MAINTENANCE
Aquaticausa.comAquaticabath.caE: [email protected]