g.0.02 code analysis - occupanc 50-percent submittal...(2) design occupant load (1004.1) - in...
TRANSCRIPT
87 Summer StreetBoston, MA 02110(617) 426-2858FAX (617) 426-1457
Limiteda r c h i t e c t s a n d p l a n n e r sDiNisco Design Partnership
Drawn By:
Date:
Revisions
Scale:
Number Date Description
File Name:
DouglasElementarySchool
Douglas,MA
G.0.02
NTS
10521.1 CD Douglas ES.plc
Construction Documents - 50%
Code Analysis -Occupancy & EgressCapacity
15 JULY 2011
Thompson Engineering Co., Inc.Electrical Engineers
Richard D. Kimball CompanyMechanical Engineers
Schofield Bros. of New EnglandCivil Engineers
Crabtree McGrath Assoc., Inc.Food Service Consultants
AKAL EngineeringPlumbing Engineers
200 Brickstone SquareAndover, MA 01810-1488(978) 475-0298FAX: (978) 475-5768
2150 Washington Street!Newton, MA 02462(617) 527-9600FAX: (617) 527-9606
44 Central Street, Unit 4Berlin, MA 01503(508) 869-0403FAX: (508) 869-2891
10 City SquareBoston, MA 02129(617) 227-6818FAX: (617) 886-9090
129 South StreetBoston, MA 02111(617) 482-4703FAX: (617) 482-4882
1071 Worcester RoadFramingham, MA 01701(508) 879-0030FAX: (508) 879-1797
Brown Sardina, Inc.Landscape Architects
161 West Main StreetGeorgetown, MA 01833(978) 352-8500FAX: (978) 352-8588
168 Main Street, Suite 3, Unit 2Northfield, MA 01360(413) 498-0069FAX: (413) 498-4386
3Si Inc.Technology Consultants
Foley Buhl Roberts & Assoc., Inc.Structural Engineering
1/16'' = 1' - 0''
3G0.02
Third Floor Occupancy and Egress Capacity Analysis
DN
DN
DN
SPEDLEARNING
CTR.MATH
SPEDTLT.
CLASSROOM CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOMCLASSROOM
CLASSROOM
CLASSROOM
CLASSROOMSPED LEARNING CTR.
CORRIDOR
GIRLS
BOYS
ELEC
SPEDTLT.
DATA
TEACH. WORK RM.
STOR.JANTLT.ELECELEV
SPEDLIFE SKILL
OPEN TO BELOW
ROOF
CLASSROOM
ELEVLOBBY
CORRIDOR
STAIR 3
SPEDAUTISM
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
390 NSF20 net sf/occupant
(9)20
854 NSF20 net sf/occ.
(25)43
135 NSF20 net sf/occ.
(5)7
100 NSF15 net sf/occ.
(12)7
TLT.75 GSF
300 gsf/occ.(0)
1
STOR.75 GSF
300 gsf/occ.(0)
1
854 NSF20 net sf/occupant
(25)43
STOR.60 GSF
300 gsf/occ.(0)
1
STAIR60"
(300)
67"(447)300
STAIR 2STAIR60"
(300)
67"(447)300
STAIR 1STAIR60"
(300)
67"(447)300
Combination643
3 Exits Required
RD
RD
CLASSROOM
CHASE
CHASE
CHASE
+
1/16'' = 1' - 0''
2G0.02
Second Floor Occupancy and Egress Capacity Analysis
UPDN
SPEDLEARNING CTR.
READING
SPEDTLT.
CLASSROOM CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOMCLASSROOM
CLASSROOM
CLASSROOM
CLASSROOMSPED LEARNING CTR.
CORRIDOR
GIRLS
BOYS
ELEC
SPEDTLT.
DATA
TEACH. WORK RM.
STOR.JANTLT.ELECELEV
TEACH. WKRM.
GYMNASIUM
CLASSROOM
ELEVLOBBY
CORRIDOR
STAIR 3
SPEDAUTISM
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
854 NSF20 net sf/occupant
(25)43
390 NSF20 net sf/occupant
(9)20
506 NSF20 net sf/occ.
(9)26
150 NSF20 net sf/occ.
(4)8
100 NSF15 net sf/occ.
(12)7
TLT.75 GSF
300 gsf/occ.(0)
1
STOR.75 GSF
300 gsf/occ.(0)
1
270 NSF20 net sf/occupant
(12)18 STOR.
60 GSF300 gsf/occ.
(0)1
STAIR60"
(300)
67"(447)300
STAIR 2STAIR60"
(300)
67"(447)300
STAIR 1STAIR60"
(300) 67"(447)300
Combination674
3 Exits Required
SPEECH130 NSF
20 net sf/occ.(4)8
OT200 NSF
20 net sf/occupant(8)10
6000 NSF7 net sf/occupant
(100 sports/550 assembly)857
Combination867
3 Exits Required
GYM STORAGE300 GSF
300 gsf/occ.(0)
1
GYM OFFICE110 NSF
15 Nsf/occ.(1)8
PT340 NSF
20 net sf/occupant(8)17
EM. EL.
99"660
67"447
67"447
67"447
EXIT TOPUBLIC WAY
EXIT TOPUBLIC WAY
UP UP
DNUP
RD
RD
CLASSROOM
CHASE
CHASE
CHASE
UP
1/16'' = 1' - 0''
1G0.02
First Floor Occupancy and Egress Capacity Analysis
UP
UP
CAFETERIA
ART
STO.
PLATFORMELEV.
E.M.R.
DRY STOR.
CUSTODIALWORKSHOP/
STORAGE
TRASH
KITCHENSERVICE
KIT.OFF.
CUST.OFF.
RECEIVING
SPRINKLERROOM
EMERG.GEN.
ELECTRICROOM
MECHANICALROOM
COR
ELEC.
MUSIC
PRACTICE
CORRIDOR
ART
CORRIDOR
MEDIACENTER
WORKROOMOFFICE
EL.
STAFFLUNCH ROOM
TITLE 1OFFICE
TLT.STO.
ELEC.OFFICE
PRIN.OFFICE
CONF.ROOM
COPYROOMSTO.
GEN. OFFICE OFFICE
OFFICE
TOILET
WAITING
ST.WAITING
EXAM
CORRIDOR
VEST
VEST
VEST
STAIR 3
STAIR 1
UNEXCAVATEDLOADING DOCK
NURSE
GIRLS
BOYSLOBBY
RAMP
CAFETERIASTORAGE
CORR
RAMP
CORRIDOR
617 GSF50 Gsf/occupant
(4)13
133 GSF100 Gsf/occupant
(3)2
164 GSF100 gsf/occupant
(3)2
213 GSF15 nsf/occupant
(7)14
157 GSF100 gsf/occupant
(5)2
250 GSF100 gsf/occupant
(6)3
314 GSF15 nsf/occupant
(12)21
3606 NSF50 nsf/occupant
(73)73
230 GSF100 gsf/occupant
(1)3
243 GSF15 nsf/occupant
(10)17
447 GSF100 gsf/occupant
(9)5
1237 NSF20 nsf/occupant
(46)62
97 NSF20 nsf/occupant
(3)5
Combination67
2 Exits Required
120 GSF300 gsf/occupant
(0)1
1200 NSF20 nsf/occupant
(23)60
Combination61
2 Exits Required
4140 NSF7 nsf/occupant
(dining 380/assembly 350)592
Combination672
3 Exits Required
244 GSF300 gsf/occupant
(0)1
1028 NSF15 nsf/occupant
(60)69
1810 NSF200 gsf/occupant
(4)10
1152 GSF300 gsf/occupant
(2)4
586 GSF300 gsf/occupant
(2)2
300 GSF300 gsf/occupant
(1)1
180 GSF300 gsf/occupant
(1)1
280 GSF300 gsf/occupant
(1)1
408 GSF300 gsf/occupant
(2)2
90 GSF100 gsf/occ
(1)1
100 GSF100 gsf/occ
(1)1
Combination8
2 Exits Required
STAIR 2STAIR60"
(300)
67"447
EXIT TOPUBLIC WAY
EXIT TOPUBLIC WAY
67"(447)300
Combination876
3 Exits Required
67"447
EXIT TOPUBLIC WAY 33"
220
EXIT TOPUBLIC WAY
67"447
67"447
67"447
67"447 RAMP
67"447
EXIT TOPUBLIC WAY
33"220
280 GSF300 gsf/occupant
(1)1
UP
TLT. NETWORKTELECOM RM
TLT.
Stairways(inches per occupant)
Other egress components
(inches per occupant)Occupancies Group E 0.2 0.15
WITH SPRINKLER SYSTEM
OCCUPANCY
Table 10-2: Egress Width Per Occupant Served (780 CMR Section 1005.1 exception 2)
Table 10-3: Exit Access Travel Distance (780 CMR Table 1016.1)
Occupancy Without Sprinkler System (feet)
With Sprinkler System (feet)
A, E, F-1, I-1, M, R, S-1 200 250
Table 10-5: Minimum Number of Exits for Occupant Load (780 CMR Table 1021.1)
Occupant Load Minimum Number of Exits (per story)
1-500 2501-1,000 3
More than 1,000 4
Table 10-6: Number of Exits by Floor for Occupant Load
FloorOccupant
LoadMinimum Number
of ExitsNumber of Exits
ProvidedTotal Capacity of Exits Provided
First 990 4 7 2,008Second 1,533 4 6 2,241Third 668 3 3 900
Fixture Requirements PopulationNumber of Required Fixtures
Number of Fixtures Provided
StudentsElem Students - Female 1 water closet / 30 384 13 14
1 lavatory / 60 384 7 8
Elem Students - Male 1 water closet / 60 384 7 8 1 urinal / 60 384 7 8 1 lavatory / 60 384 7 8
Elementary Students 1 drinking fountain /75 students 768 11 11Staff note (a)
Female 1 water closet / 20 59 3 7 1 lavatory / 40 30 1 4
Male 1 water closet / 25 0 note (a) 1 lavatory / 40 30 1 3
Community Use for Assembly - Cafetorium * (or majority fraction therof) 350 / 2
Female 1 water closet / 200 175 1 3 lavatories - note (b) 175 1 2
Male 1 water closet / 600 175 1 1 1 urinal / 200 175 1 2 lavatories 1/200 - note (b) 175 1 2
Community Use for Assembly - Gymnasium * (or majority fraction therof) 550 / 2
Female 1 water closet / 200 225 2 3 lavatories - note (b) 225 2 2
Male 1 water closet / 600 225 1 1 1 urinal / 200 225 2 2 lavatories 1/200 - note (b) 225 2 2
Other Fixtures PE Office Shower 0 0 1 1 service sink / floor 3 3
(a ) This project provides unisex toilets for staff toilets. For the purpose of calculating the number of required unisex toilets, the calculation will be based on the higher female watercloset count.
(b) Lavatories are not specifically referred to by the Massachusetts Plumbing Code in this provision, but the International Plumbing Code recommends lavatories at the rate of 1 per 200.
Table 248 CMR 10-2: Minimum Facilities for Building Occupancy - Use Group Educational (Based on 248 CMR 10.10 (18): Table 1)
Table 10-1: Occupant Load (780 CMR Table 1004.1.1)
Floor Use SF / Person Area Occupant Load by Table
Actual Number of
Occupants 1
Design Occupant
Load 2
First Cafetorium (Assembly-Chairs Only-unfixed) 7 net 4,140 NSF 592 350 592Platform 15 net 1,028 NSF 69 60 69Cafeteria Storage 300 gross 244 NSF 1 1 1Kitchen 200 gross 1,810 NSF 10 4 10Music/Practice 20 net 1,334 NSF 67 46 67Nurse/Exam 50 gross 617 GSF 13 4 13 Art 20 net 1,200 NSF 60 23 60Media Center 50 net 3,606 NSF 73 73 73Guidance 100 gross 266 GSF 3 6 6General Office/Waiting 100 gross 447 GSF 5 9 9Staff Lunch 15 net 314 NSF 21 12 21Conference 15 net 243 NSF 17 10 17Custodial Workshop 100 gross 743 GSF 8 2 8Custodian Office 100 gross 89 GSF 1 2 2Trash 300 gross 408 GSF 1 2 2Mechanical/Electrical 300 gross 1,912 GSF 7 6 7Prinicipal 15 net 244 GSF 17 7 17 Records/ Duplicating 100 gross 190 GSF 2 2 2 Network Telcom 100 gross 230 GSF 3 1 3 Title 1 Offices 100 gross 407 GSF 5 11 11 Total First Floor Occupant Load 975 631 990
Second Classrooms 20 net 10,248 NSF 513 300 516Teacher Workroom 15 net 370 NSF 25 24 25 SPED 20 net 2,570 NSF 129 73 129Gym (Assembly - Chairs Only - unfixed) 7 net 6,000 NSF 858 550 858 Storage 300 gross 272 GSF 1 0 3PE Office 100 gross 110 GSF 1 1 1Gym Storage 300 gross 150 GSF 1 0 1 Total Second Floor Occupant Load 1,528 948 1,533
Third SPED 20 net 2,733 NSF 137 73 138Classrooms 20 net 10,248 NSF 513 300 516Teacher Workroom 15 net 100 NSF 7 12 12Storage 300 gross 142 GSF 1 2 2Total Third Floor Occupant Load 658 387 668
(1) Actual number (1004.1.1) - The actual number of occupants for whom each occupied space, floor or building is designed.
(2) Design Occupant Load (1004.1) - In determining means of egress requirements, the largest number of occupants computed in accordance with Sections 1004.1 through 1004.9.