fx 110 / fx 120 user instructions - brice...

24
Brisch number 76103-390 Issue 2 09/08/02 ENGLISH *76103-390* Weight Only Scale FX 110 / FX 120 User Instructions

Upload: duongtruc

Post on 25-Jul-2018

263 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Brisch number 76103-390 Issue 2 09/08/02

ENGLISH *76103-390*

Weight Only Scale

FX 110 / FX 120User Instructions

Page 2: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Avery Berkel Limited 2001. All rights reserved.

The information contained herein is the property of Avery Berkel Limitedand is supplied without liability for errors and omissions. No part may bereproduced or used except as authorised by contract or other writtenpermission. The copyright and the foregoing restriction on reproductionand use extend to all media in which the information may be embodied.

c

Page 3: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Warnings

Cleaning the scale

For your protection, all mains (110V or 230V) equipment used where damp orwet conditions may occur, must be supplied from a correctly fused source andprotected by an approved RCD to BS7071 or BS7288 or IEC1008-2-2 BS EN61008:1995. IF IN DOUBT SEEK ADVICE FROM A QUALIFIEDELECTRICIAN.

To avoid the possibility of electric shock or damage to the machine, alwaysisolate from the mains power supply before carrying out any routinemaintenance.

Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions,such as washing soda, should not be used especially on the display windows.Under no circumstances should you attempt to wipe the inside of the machine.

The outside of the machine may be wiped down with a clean cloth moistenedwith water containing a small amount of washing up liquid.

Page 4: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

1

2

3

FX110

Make sure that the work surface is firm, steady and free from vibration and

draughts.

Hold the scale by the base when picking up. Do not pick up the scale by the

weigh plate or cross.

Adjust the feet if the scale is not level.

Remove parts 1- 4 before installing the machine

InstallationFX110 only

Page 5: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

F 110 connectionsX

Power

Programming

Display

RS 232 Serial

FX 120 connections1 Remove weigh plate.

FX120

To avoid the risk of RSI (Repetitive Strain Injury) it is important to ensure thatthe machine is placed on a surface which is ergonomically satisfactory to theuser. In cases where usage is prolonged EN614-1 recommends frequentbreaks for the user.

Installation

Page 6: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

2

3

4

Connect power cable.

To connect remote display.

Replace the weighplate. Connect to power point.

OR

Page 7: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Fitting the FX 120 scale mounted displayMake sure the scale is not connected to the power supply and remove

weigh plate.

Turn over machine and place on a safe, level surface.

Turn the machine round so the required mounting slot is next to the edge of

the counter.

Remove the screw in the mounting slot.

1

2

3

4

Slot 1

Slot 2

Slot 3 - required mounting slot

Page 8: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Place the mounting bracket into the slot.5

6 Place washer over screw hole and fix with the large replacement screw.

Page 9: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

7

8

Refer to the drawings on the following pages and:

Place machine upright.

Do not lift the scale by the column display or the weighplate.

9 Replace the weigh plate. Connect to power point.

Caution:

Plug the display cable into the base.Feed the slack cable round the base.Secure the cable clips.

Page 10: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Cable route: single displayCable from slot 3

Cable from slot 2

Cable from slot 1

12

3

4

5

8

9

6

7

1

2

3

4

1

2

3

4

Page 11: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Cable route: dual displayCable from slot 3

Cable from slot 1

1

2

3

4

12

3

4

5

8

9

6

7

Page 12: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Cable route: dual displayCable from slot 2

Cable from slot 1

1

2

3

4

1

2

3

4

Page 13: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Cable route: dual displayCable from slot 2

Cable from slot 3

12

3

4

5

8

9

6

7

1

5

23

4

Page 14: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Securing the cable clips

Page 15: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

FX 120 battery operationNote: Battery operation is not available on the FX110

Plug the battery pack into the scale (use 6 x 1.5v 2‘D’ size cells) and place thepack into the recess. Replace the cover and weighplate.

To avoid damage to the scale caused by leaking batteries, removeflat or damaged batteries immediately.Please note: Rechargable NiCad batteries are not suitable for this applicationdue to their inherent short circuit thermal characteristics which can adverselyaffect the performance of the scale.

When you see the symbol flashing on the display (or Battery LEDflashing), then you must either replace the batteries (or recharge therechargeable battery).

Caution:

Using a rechargeable battery pack

Recharging the battery pack

Note:

- Plug the rechargeable battery packinto the scale and place the pack into the recess. Replace the cover andweighplate.

- Plug the mains cable into the socketlocated on the base of the scale, then switch on using the mains ON/OFFswitch.

You can still use the scale while the battery is being charged.

NiCad

Page 16: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Error messagesIf a persistent error message appears or the scale locks up,disconnect then reconnect the scale to the power supply. If thescale remains inoperative, contact your authorised service agent.

Battery failure.Power supply voltage is too high.Memory checksum invalid.Prohibited function.Prohibited scale capacity.

Tare weight unsteady

Cannot use EPOS tare.Mismatch between EPOS and scale tare increments.

Error codes:

F 10F 11F 30F 35F 36

E 120

E 123E 124

Contact your service agent if you see any other F messeges.

.Tare too heavy.Tare already in operation.

Unit price not accepted.Scale has not returned to zero between EPOS transactions.

E 121E 122

E 130E 131

F 30

Temporaryerror

Weightunsteady

Balancefailed

Underrange

Overrange

Page 17: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Waking up the scaleDepending on configuration...

Either

Displaying service information

Resetting the machine

Selecting sleep mode

Using the scale

Testing the display

Or

LED

LCD

LCD LED

LCD LED

Press and hold

Press and hold

Or

TOr

Page 18: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Weighing goodsPlace the goods onto the scale.

Zeroing the scaleMake sure that the scale is at zero before weighing any goods.

Using tares

Repeat until all the goods have been weighed.

Cumulative tare

T

To cancel a tare

T

TT

Or

LCD LED

Page 19: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Navigating management mode

Example: turn the keyboard bleeper off and change the backlight time to 5seconds.

Management Mode

Entering management mode

Go to the next branch (press and hold)Go to next sub-branch

Go to the previous branch (press and hold)Go to previous sub-branch

Sets the value to 0 enabling you to display a new valueReturn to Branch 00 (press and hold)

C

Branch Sub-branch12 .95

1 Branch ( )12

For Example:

Branch ( )13

Sub-branch ( )Sub-branch ( )

0001

Sub-branch ( )98

Value

0 .00 19 .0119 .00 0

29 .00

04

C

Press and hold

C

Press and hold

Displays the value. Press again to re-displaythe branch / sub-branch

After clearing a value to be changed each key pressincrements the value displayed. Pressing and holdingthe key increments the value by 10.

After changing a value, you mustgo to the next branch to accept the value.Note:

Exit management mode

Press and hold

1

1

LCD

Or

LED

20 .00

C

Press and hold

Press and hold

Page 20: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Switching the keyboard bleeper on/offGo to branch 19, Sub-branch 01

0 = Off1 = On

19 .01

1

Error bleeperGo to branch 19, Sub-branch 03

19 .03

1

Target bleepBranch 19, Sub-branch 02 - Not applicable for this machine.

Changing the bleeper volumeGo to branch 19, Sub-branch 04

0 = Quiet1 = Loud

19 .04

1

0 = always off1 = 5 seconds2 = 1 minute3 = 5 minutes4 = always on

20 .00

1

Changing the backlight timeGo to branch 20, Sub-branch 00

0 = none1 = 1 minute2 = 5 minutes3 = 30 minutes

20 .01

1

Changing the sleep timeGo to branch 20, Sub-branch 01

0 = Off1 = On

Switching the bleeper alarm on/offGo to branch 19, Sub-branch 00

0 = Off1 = On

19 .00

1

Page 21: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Changing the timeout periodGo to branch 74, Sub-branch 02

74 .02

20

Enter a value in units of 10 milliseconds (1-255).For example :200 = 2 seconds150 = 1½ seconds100 = 1 second

Changing the duration of a ‘Long' press (press and hold)

Go to branch 29, Sub-branch 00

29 .00

200

Enter a value in units of 10 milliseconds (50 -255).For example :200 = 2 seconds150 = 1½ seconds100 = 1 second

Enabling key timeoutGo to branch 74, Sub-branch 01

74 .01

1

0 = Disabled1 = Enabled

Page 22: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer
Page 23: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Declaration of Conformity

The non-automatic weighing instrument

Manufacturer Avery BerkelType

Corresponds to the requirements of the following EC directives:

90/384/EEC*89/336/EEC73/23/EECEN 45 501*EN 50 081-1EN 60 950

*This declaration is only valid if the non-automatic weighing instrument wasverified by the manufacturer or with a certificate of conformity issued by anotified authority.

Non-Automatic Weighing Instruments Directive

EMC Directive

Low Voltage Directive

The applicable harmonised standards are:

FX 110Number of EC type approval certificate UK 2625

Manufacturer Avery BerkelType FX 120Number of EC type approval certificate T5532

This is a class A product. In a domestic environment, this product may causeradio interference in whch case the user may be required to take adequatemeasures.

A copy of the original signed declaration for this instrument is available from:Foundry Lane, Smethwick, West Midlands, England. B66 2LP

EMC Compliance

Page 24: FX 110 / FX 120 User Instructions - Brice NSWbricensw.com.au/wp-content/uploads/2014/06/FX120_Manual.pdf · FX 110 / FX 120 User Instructions. Avery Berkel Limited 2001. ... Manufacturer

Email: [email protected]@averyberkel.com

Internet: http://www.averyberkel.com