fva-3800.1_ang
TRANSCRIPT
-
8/12/2019 FVA-3800.1_ang
1/4
KEY FEATURES
Up to four attenuators per unit
Very fast settling time
Integrated power meter for accurate output power control
Polarization-maintaining option
Front-panel control as well as remote control via USB orEthernet
APPLICATIONS
BER testing
System loss emulation
Coherent transmission
Bidirectional Optical Sub-Assembly (BOSA)
FVA-3800MULTIPORT BENCHTOP OPTICAL VARIABLE ATTENUATOR
Ideal for BER testing and system verification in labs or demanding manufacturing environments. r
-
8/12/2019 FVA-3800.1_ang
2/4
FVA-3800
Rugged and Reliable
The rugged and reliable design of the FVA-3800 is built using components with high mean-time-between-failure (MTBF)specifications. Thanks to minimal maintenance, our attenuators can be used in 24/7 production environments.
Power Stabilization
The power monitoring function is used to set the attenuator output power level. When enabled, this option maintains power stabilityeven when there is a fluctuation in source power. It also simplifies test setups by eliminating the need for an external power meter
Polarization-Maintaining Option
The FVA-3800 is compatible with polarization-maintaining fiber. This eliminates the need to use an external polarization controlleto maintain the polarization of the input signal, which is critical for coherent transmitters, receiver design and testing.
SIMPLE, FLEXIBLE AND USER-FRIENDLY INTERFACE
Front Panel Control
Equipped with an LCD display, the FVA-3800 does not require a PC to set the attenuation range, wavelength or power outputlevel. This makes it fast and easy for users to set all the required parameters.
PC Application for Multi-Instrument Management
EXFOs Test Instrument Manager application, TIM, makes it very easy for users to control and view the status of each attenuatorSimply connect a PC running the application to the FVA-3800 via USB, for single device operation, or connect via Ethernet, fomulti-device operation.
The TIM application is also compatible with the FLS and IQS-2800 ITLA tunable light sources.
Remote ControlStandard USB and Ethernet interfaces enable the FVA-3800 to be remotely controlled from a PC or test station. This allows usersto program their own software solutions for complex procedures or to automate their testing using SCPI commands.
VERSATILE AND COMPACT SIGNAL ATTENUATION SOLUTIONThe FVA-3800 Multiport Benchtop Optical Variable Attenuator is designed for a broad range of applications for users with verydemanding research requirements as well as for those looking for a fast, high-density solution.
It is the most compact instrument on the market. Capable of integrating up to four attenuators in a single unit, users with tightspace requirements are now able to get a no-compromise solution.
ATTENUATOR
POWER METER
Input Output
s with high mean-time-i -tin 24/7 production envir u vi
ower level. When enableo es test setups by eliminatis s
ning fiber. This eliminateich is critical for coherentc l
ENDLY INTERFAC
-
8/12/2019 FVA-3800.1_ang
3/4
FVA-3800
NOTE
a. All specifications are preliminary; valid at 23 oC 3 oC unless otherwise stated.
TECHNICAL SPECIFICATIONSa
Description FVA-380x-B FVA-380x-P
Fiber type 9/125 m, SMF-28 PMF
Number of channels 1 to 4 1 or 2
Wavelength range (nm) 1260 to 1620 1510 to 1610
Maximum attenuation (dB) > 45
Insertion loss (dB) < 2.0
Attenuation setting resolution (dB) 0.01
Attenuation repeatability (dB) 0.1
Power metering range (dBm) 50 to 20
Relative uncertainty of power meter (dB) 0.05
Averaging time of power meter (s) 0.002 to 1
PDL (dB) peak-to-peak (typical) < 0.3
Return loss (dB) > 45
Max. input power (dBm) 23
Transition speed (dB/s), typical 0.1 to 1000
SPECIFICATIONS
GENERAL SPECIFICATIONSa
Size (H X W X D) 100 mm X 222 mm X 330 mm (3 15/16in X 9 in X 13 in)
Temperature Operating Storage
5 C to 45 C (41 F to 113 F)40 C to 70 C (40 F to 158 F)
PC interface method USB 2.0, Ethernet
Minimum PC requirements Pentium 4, 1 GB RAM, USB 2.0
Power supply ~100 240 V; 50/60 Hz; 60 W maximum
0
l wise stated.l i .
m
-
8/12/2019 FVA-3800.1_ang
4/4
EXFO is certified ISO 9001 and attests to the quality of these products. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not causeharmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EXFO has made every effort to ensure that the information contained inthis specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units omeasurement in this document conform to SI standards and practices. In addition, all of EXFOs manufactured products are compliant with the European Unions WEEE directive. For more information, please viswww.EXFO.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor.
For the most recent version of this spec sheet, please go to the EXFO website at www.EXFO.com/specs.
In case of discrepancy, the Web version takes precedence over any printed literature.
EXFO Headquarters > Tel.: +1 418 683-0211 | Toll-free: +1 800 663-3936 (USA and Canada) | Fax: +1 418 683-2170 | [email protected] | www.EXFO.com
EXFO serves over 2000 customers in more than 100 countries. To find your local office contact details, please go to www.EXFO.com/contact .
FVA-3800
ORDERING INFORMATION
Channels
1= One channel (P models only)2= Two channels4= Four channels (B models only)
Models
B= Single-mode SMF-28 fiberP= Polarization-maintaining fiber
FVA-380X-X-XX
Connectors
58= FC/APC89= FC/UPC91= SC/UPC
SPFVA3800.1AN 2014 EXFO Inc. All rights reserved.
2008
Printed in Canada 14/02
Example: FVA-3801-B-58