Future-Proof Your Revenue Growth With OptiCool®
Presented by:Nicholas ArmstrongUS Tech [email protected]
OptiCool Technologies is an affiliate company of Calvary Robotics – a 20 year history of engineering innovation
We design, engineer, manufacture and market our award-winning OptiCool® cooling system in Webster, NY
Company Overview
We focus exclusively on refrigerant-based rack containment and overhead proximity cooling solutions for mission critical cooling applications
Recognized by Gartner as a 2013 “Cool Vendor” in Data Center Infrastructure, Power and Cooling
OptiCool® revolutionizes data center design by reducing the need for airflow management as the primary design criteria for cooling
75,000 square foot headquarters facility, Webster, NY
Cool Row® System
Cool Door® System
Key Concept: Air vs H2O vs R134a
For the same unit volume: Water carries 3,500 times more heat than air R134a with endothermic phase change carries 50 times more heat than water “Moving from air to water reduces the energy costs of cooling by 50%” “When using refrigerant, it reduces energy costs by 90%”, over air
WaterAir
*Source: The Science of Cooling, Phil Hughes, October 11, 2013
R134a
Key Concept - Data Center Cooling Model
ROW (In-Row)
ROOM (CRAC/CRAH)
Model Source: Gartner
Key Messages Cooling closest to the heat source drives efficiency
The conventional “cool the room” approach is the least efficient
COMPONENT(Most Efficient)
RACK (OptiCool)
Managing airflow with “containment” has limitations
High energy and space costPoor utilization of space Fire suppression challengesLimited capacity (10-15 kW) per rack ~2.8 to 4.3 tonsSound Pressure – System Dependent
Managing “airflow” is complex and costly
High energy and space costExpensive CFD software / consultingExpensive plenum / duct workLimited capacity (8-10 kW) per rack ~ 2.3 to 2.8 tonsSignificant Sound Pressure - ~80 dB
In-Row Cooling is floor space and energy intensive
High energy and excessive space costRedundancy challengesExtreme noise levelsLimited capacity (10-15 kW) per rack ~ 3 to 4.3 tonsSignificant Sound Pressure - ~75 dB
Capacity (30 kW per rack or ~9 tons) Redundancy (20 kW N+1) Energy efficiency (up to 96%) Space efficiency Proximity cooling NEBS Zone 4 Rated Reduced Sound Pressure - 50 dB
Move cooling closer…Contain at the rack…
Key Concept - Data Center Cooling Model
Conventional Cooling
Complex, Costly and Inflexible
Why Rack ContainmentWhy OptiCool®
Why - “Future-Proof” Your Design
Time
HeatDensity
Industry Trends Impacting Design Leading OEMs forecast increasing heat density “Rack Utilization” is increasing (Gartner)
“Rack Height” is increasing (IMS)
201520102005 2025
Increase
Steady
Decrease
Which heat density trend line should you plan for?
2020
10 kW+
How Does OptiCool® Future-Proof Design?
Room
Row
Rack
Capacity
Efficiency
COP 5
COP 140+
30 kW+
15 kW
OptiCool® provides superior support for low- to high-density cooling
CRACs / CRAHs
CONTAINMENT
Rack containment (efficient and effective)
Superior scalability (low to high density)
Modularity (scale higher and scale lower)
Lower cost of construction
Superior efficiency
Superior 10 year TCO (cost of ownership)
Liquid Cooling
10 kWAirflo
w Mgt
Why – OptiCool Redundancy
R e v o l u t i o n i z i n g D a t a C e n t e r D e s i g n
Room Absorption N+1 N+2 2N
Why - Rack Containment Supports Taller Racks
R e v o l u t i o n i z i n g D a t a C e n t e r D e s i g n
Grow Vertically to increase your data center lifespan
Maximize data center space
Deploy taller racks (45U-56U)
Take advantage of high-capacity
Why - The OptiCool® System Seismic Compliant
First seismic compliant close-coupled cooling solution
NEBS Zone 4 Seismic GR-63
Pump system, door, cooling units, power and hoses
Tested to an 8.2 seismic event
All components tested leak-free
Telecommunication Standards
Seismic signifies qualityS e i s m i c H a z a r d M a p
OptiCool® Family of ProductsHow It Works
OptiCool® System Overview
Chilled water or DX heat exchange outside the data center
Modular, active cooling system scalable by design to support low- to high-density
Universally adaptable to equipment cabinets
Close-coupled, refrigerant-based cooling (R-134a) within the data center
Refrigerant Pump System
uses 1.5 kW for 210 kW
Refrigerant Distribution
Network (RDN)QuickConnec
t Stainless Steel Flex
Hoses
Active Heat
eXtractors (AHXs)
Cool Door® System
OptiCool® System – How it Works
Cool Door® System
Supply
Return
Supply Return
Pump System
Flow
Active Heat Extractor
Refrigerant Distribution Segment (RDS)Supply Size
1 3/8” OD
Return Size
2 5/8” ODIndoorRefrigerantDistributionNetwork
OutdoorChiller
Cool Row® System
HosePair Stainless
How - OptiMizer™ RPx Outdoor Heat Rejection
Direct Expansion PumpChilled Water Pump
OptiMizer™ RPC-210OptiMizer™ RPW-210
210 kW60 Ton
210 kW60 Ton
How - Rack ContainmentRear Door Cooling
Active Heat eXtractor (AHX)
Dual Power(Standard)
Key Messages Supports Cool Door® and Cool Row® applications 2N Design with dual fans, power and sensors Up to 10 kW Capacity 14 lbs / 22” x 14”
Inside Rack View
DualSensors
R-134a Supply
R-134a Return
EvaporatorProtectorShield
Rear Aisle View
Monitoring port for BMS integration Self-Sealing Quick Connect Stainless Hoses Fans Are Energy Neutral and Adjust to Heat
Load
System Status Indicator LEDs Dry Contact
Monitoring Port(Fan, Power &
Sensors)Settable Fan Speed (3 fixed / 5 variable)
Cool Door® System (CDSe) – Extruded Door
For Standard Cooling ApplicationsFeatures Rack Agnostic Single or Dual Power Manual Bypass 80 lbs Fully Configured 22”, 24”, 28”, 30”, 32”… 42-44U, 45U, 48U, 56U
Manual Bypass
Integrated Cable Management
AC or DCPower (A)
AC or DC Power (B)
Cool Door System MT
Features Adaptable to Multi-tenant rack
enclosures Mesh door system with secure lock
access for (2) separate user compartments
Modular cooling design for 10kW to 30kW per equipment rack enclosure
Compatible with most access control systems
Fully-Integrated Cooling Cabinet Option
Cool Door® System Mighty Mo GX & LX
Fully integrated cooling solution
Elimination of custom engineering
Elimination of cabinet transition frame
Reduced equipment, shipping and installation costs
Simplified ordering
Proximity CoolingOverhead Applications
How - Cool Row® System (CRS)
For Horizontal Heat Capture Applications
Features
• Plenum Width – 24” or 30”
• AHX Support – 2 AHX (52”) or 3 AHX (74”)
• Inlet – top or bottom
• Mounting – ceiling or floor
• Power – single or dual power
Cooling Applications include top exhaust cabinets, UPS, hot-aisle and mechanical rooms using the ceiling as a plenum
Ceiling Side (Top) Inlet
Bottom Side (Floor) Inlet
CRS-3 AHX System 74”
CRS-2 AHX System– 52”
Room Absorption Redundancy – Low Density
Key MessagesLow density (6 kW) or belowOptiCool® lowers the ambient temperature of the “Zone of Influence” (ZOI)Room automatically absorbs heat load in the event of a system outage
In-Rack Cooling Redundancy – Parallel RDNs
Key MessagesIn-Rack, real-time redundancy with separate closed-loop systemsTarget capacity per rack is based on the number of AHX units / pump systems“True N+1” versus “Theoretical N+1”
RefrigerantPump
System
ARefrigerant
PumpSystem
B
OptiCool® is the only solution in the world with in-rack redundancy universally adaptable to equipment racks
In-Rack Cooling Redundancy – Triple RDNs
Key MessagesIn-Rack, real-time redundancy with triple closed-loop systemsCooling source redundancy to each rack – up to 20 kW redundant cooling Target capacity per rack is based on the number of AHX units / pump systems“True N+2” versus “Theoretical N+1”
RefrigerantPump
System
ARefrigerant
PumpSystem
BRefrigerant
PumpSystem
C
OptiCool® is the only solution in the world with in-rack redundancy universally adaptable to equipment racks
OptiCool® Data Center Cooling Solution
60 Ton / 210 kW pump capacity for DX or CW
Refrigerant-based cooling (R-134a or R450A)
Non-conductive, non-corrosive
Small 36” x 40” footprint
Low pressure (75 psi)
OptiMizer™
Refrigerant Pump SystemsCool Row® Proximity Cooling
Adaptable to any rack 24” to 32” wide and 40U to 56U tall
Low- to high-density (zero to 45 kW)
“Active” Heat Removal – AC / DC power
Modular design up to 10 or 15 kW per AHX unit
20 kW N+1 redundancy per rack
Cool Door® Close-coupled Cooling
Top exhaust UPS Top exhaust
computing equipment
Hot-aisle with integrated LED lighting
OptiCool® Results
ResultsEfficiency Face-off: OptiCool® Versus CRAHs
Type QuantitySensible Cooling Capacity
Power Consumption
(kW)
Estimated Annual Energy Cost
Annual Energy Cost per kW of Capacity
20 Ton CRAH 760.25 kW / CRAH
421.7 kW
73.5 kW (10.5
kW/CRAH)$64,386
$152.68
($64,386 / 421.7 kW)
RPW Refrigerant
Pump2 420 kW / Pump
3.0 kW (1.5
kW/Pump)$2,628
$6.25
($1,314 / 420 kW)
Power SavingsEstimated Energy
SavingsCooling Energy Savings per kW
70.5 kW $61,758 $146.43 kW / 96%
96% more energy efficient
Assumes $0.10 / kW-hr electricity rate (8760 hr / year)
AHX fans are energy net-neutral
Heat Rejection: Chilled Water System
60% more energy efficient
Assumes $0.10 / kW-hr electricity rate (8760 hr / year)
AHX fans are energy net-neutral
Results OptiCool® Rack Containment Cooling
Refrigerant-based cooling (R-134a or R-450A) Non-toxic, non-conductive, non-corrosive Low pressure (75 psi) “Active” Heat Removal of 10 kW per AHX unit 20 kW N+1 redundancy per rack Effective and efficient cooling
Features$ Reduce cooling energy use from 60-95%$ More floor space for additional racks$ Reduced floor weight$ Eliminates the need for a raised floor$ Qualifies for energy efficiency capital subsidy
programs Reduced noise levels
Benefits
CAPACITY - Low- to High-Density; up to 30 kW per rack / 20 kW N+1 “in-rack redundancy”
ADAPTABILITY - The Cool Door® System is adaptable to any equipment rack; The Cool Row® System provides proximity cooling
SCALABILITY - The modular design offers unparalleled scalability to align cooling with heat load as needed
ENERGY EFFICIENCY - The equipment rack becomes the ultimate containment solution where the RPW 210 kW pump uses only 1.5 kW of energy
SPACE EFFICIENCY - OptiCool® uses less footprint than perimeter CRAC’s, CRAH’s or In-Row Cooling
The OptiCool® Value Proposition
CASE STUDY New - Colocation Facility Suite Designed for OptiCool Cooling
Low- to High-Density 2 kW to 20 kW N+1
Phase I – 28 racks / 420 kW Capacity
Additional Phases – 200 racks / 2.4 MW
Victory Technology Center – Buffalo, NY
Examples of Different Install Environments