ftth cpe gateway

SAL0

05_0

2_U

K

Page 2: FTTH CPE Gateway Dktc Omega

DKTCOMEGA designs optical and coaxial products for professional broadband operators and service providers. DKTCOMEGA’s unique fibre optical product line, combined with the company’s extensive FTTx experience, makes it a strong partner for FTTx operators and service providers.

The company was founded in 1977. Its headquarters are in Denmark and it has subsidiaries in Sweden, Finland and China. It has always been DKTCOMEGA’s philosophy to challenge the status quo and look for improvements to benefit the customer. In the late nineties DKTCOMEGA was therefore among the first to enter into the optical network market and soon launched its own line of products in this field. By being an early mover in fibre optics DKTCOMEGA has gained extensive in-depth technical knowledge and market respect, especially in the rapidly growing FTTH market.

DKTCOMEGA’s missionDKTCOMEGA’s mission is to be a strong partner in network products for European broadband operators and solution providers. Based on know-how and natural enthusiasm, good ideas are developed into suc-cessful products. This is done together with the customer, who furthermore can appreciate the broad product range, the attractive quality/price level and the unique customised products. DKTCOMEGA’s flexibility and proactive attitude assists in optimizing broadband networks. For requests, please contact: [email protected].

CPE gateway with TV/FM (analogue /digital) .............................................................5

CPE gateway with IP services (digital) .......................................................................7

CPE gateway extended with IP services and TV/FM ....................................................9

CPE gateway with management ...............................................................................11

CPE gateway with optional VoIP ..............................................................................13

Features ............................................................................................ 15

References .............................................................................................................16

Glossary .................................................................................................................17

about dktcomega

Specifications are subject to change without notice. DKTCOMEGA is not liable for any misprints or errors.

Page 3: FTTH CPE Gateway Dktc Omega

IntroductionSince its launch in 2003, DKTCOMEGA´s Fibre-To-The-Home (FTTH) CPE gateway has helped service providers in Scandinavia and Europe in cost-effectively deploying highly reliable triple-play services. The CPEs are based on open standards and a modular design, thereby allowing them to interoperate with third party network equipment. The CPEs are developed in close cooperation with leading broadband operators. As a consequence of the unique modular architecture, DKTCOMEGA offers the CPE in many different versions. This brochure can be used as inspiration for further discussion. DKTCOMEGA’s concept of the FTTH CPE gateways is to deliver a flexible modular product, which can be modified to meet specific needs. Besides the CPE gateways, DKTCOMEGA can deliver other access equip-ment such as splitters, laser transmitters and EDFAs for the RF overlay (refer to separate brochure).

product introduction

3

Focus areasIn the design of the CPE gateway DKTCOMEGA has focused on the following areas:- Efficient installation, ease of use- Discrete and modern design- Long-term reliability- Modular design and customisation- Integrated power supply and fibre management- Open standards and full flexibility

The FTTH access network This is an illustration of an FTTH network consisting of a core and an access network. DKTCOMEGA is focusing on the access network with the CPE gateways being presented in this brochure. For further information regarding other products, please contact [email protected].

CPE w.

TV/FM

CPE w.

IP services

CPE w. IP services

& TV/FM

CPE w.

management

CPE w. manage-

ment & TV/FM

Item no. (example) 79120 79119 79101 / 79102 79252 79204 / 79403

RF overlay

Media converter 10/100

Media converter 100/1000

Management

Overview of CPE gateways presented in this brochure

For more information regarding this product, refer to the FTTx brochure.

For RF overlay refer to the separate brochure.

Page 4: FTTH CPE Gateway Dktc Omega

Advantages

- The easiest way to add TV/FM services to a FTTH network- Cost optimized - cost per TV/FM channel / service- An open opportunity to add IP services at any time- No need for set-top boxes- Easy installation - ease of use - plug and play - Services: TV/FM, DVB-C, DVB-T, DAB

Page 5: FTTH CPE Gateway Dktc Omega

Product informationThis type of network is for operators offering only TV/FM services

(analogue and digital, QAM/QPSK), but who later would be inter-

ested in upgrading with IP services. This is an ideal solution for dis-

tributing analogue TV-signals to many TV sets and FM receivers.

The idea behind this type of network is to deploy a standard ana-

logue/digital RF head-end at the transmission side. The RF signal is

converted to an optical signal via a transmitter and sent through an

optical network to the subscriber. Here the signal is converted back

to an electrical signal via the DKTCOMEGA CPE gateway, which can

then be received by the majority of households.

The CPE gateway suits analogue TV/FM delivery from

45-862 MHz, as well as DVB-C/DVB-T digital television and DAB

standards. The high performance and low-noise broadband optical

receiver module provides an 88 dBµV output level with superior sig-

nal specifications, capable of handling a large number of radio and

television channels for simultaneous delivery.

The TV/FM converter has a built-in Optical AGC, which enables

a constant RF output independent of minor optical fluctuations

or level changes that can be caused by product lifetime or

environmental changes.

TV/FM Converter Units Data Notes

Optical wavelength nm 1310 … 1550

Max optical input level dBm 3

Operational optical input level (sensitivity) dBm -10 … 0

RF bandwidth MHz 45-862

RF output level dBµV 88 *

RF flatness dB +/- 1

CNR (Carrier-to-noise) dB > 50 *

CSO (Composite Second Order) dB > 60 *

CTB (Composite Triple Beat) dB > 60 *

Optical indicator LED dBm < -10: red> -10: green

RF connector, impedance F-female 75 Ω

Optical connector SC/APC

General Units Data Notes

Supply voltage VAC 100 - 240 **Operating temperature ºC 0 - 55 †

Power consumption W < 4

Dimensions mm 240 x 210 x 60 +

Weight kg 0.8

Colour White

ftth cpe gateway with tv / fm

5

* Measured at -6 dBm optical input, CENELEC 42 channels. OMI 4 %

** Internal power supply† Support for extended temperature range on request+ 185 x 180 x 55 mm without trim cover

RoHS compliantEMC Immunity: EN55024:1998+A1:2001+A2:2003EMC emission: EN55022:1998+A1:2000+A2:2003Low voltage directive: 2006/95/ECi,EN609501

Page 6: FTTH CPE Gateway Dktc Omega

Advantages

- Easy installation - plug-and-play- Easy upgradable, remotely- High dependability- A flexible modular design (hardware and software)- A flexible network interface, fits with most third party products

Page 7: FTTH CPE Gateway Dktc Omega

ftth cpe gateway with ip services

Product informationThis gateway is used by operators, who have chosen to

deliver IP services only. The gateway delivers a future

proof connection with 10/100 or 1000 Mbps Ethernet

between the distribution point and the subscriber.

This provides a virtually unlimited capacity for internet,

VoIP, and IPTV. Other services can include Meter Reading,

gaming, and VoD. The media converter can be delivered

either as bi-directional or as a two fibre solution Rx/Tx

data transmission.

DKTCOMEGA’s CPE gateway is very flexible and developed

with basic functionality to ensure the high reliability.

The gateway is suitable for open access networks, and it

works with many third party products.

General Units Data Notes

Supply voltage VAC 100 - 240

Power consumption W < 5

Operating temperature ºC 0 - 55 *Dimensions mm 240 x 210 x 60 **Weight kg 0.7

Colour White

7

* Support for extended temperature range on request

** 185 x 180 x 55 mm without trim cover

Media converter Units Data Notes

Optical wavelength nm 1310 … 1550 - Bidirectional or two fibre

Speed (LAN) Mbps 10/100 or 10/100/1000

Speed (optical) Mbps 100/1000 full duplex

Operational optical input level dBm -33 … -3

Max Optical input level dBm -3

LAN ports RJ-45 1 / 2 / 4

Optical connector SC/PC

EMC Immunity: EN55024:1998+A1:2001+A2:2003EMC emiision: EN55022:1998+A1:2000+A2:2003Low voltage directive: 2006/95/ECi,EN609501

Page 8: FTTH CPE Gateway Dktc Omega

Advantages

- The most complete solution on the market (both analogue and digital services)- A well proven concept throughout Scandinavia since 2003- Simple and thus high dependable technological design- Practical with very easy installation

Page 9: FTTH CPE Gateway Dktc Omega

ftth cpe gateway extended with ip services and tv / fmProduct informationThis CPE gateway is for operators, who have decided to carry

both analogue and digital services, because most household

devices (radios and TVs) are still analogue. This is often the

most optimal solution for the end-user, where they can use

the IPTV signal for the main TV and the analogue signal for the

other TVs in the household.

To deliver these two signals simultaneously DKTCOMEGA offers a

CPE gateway with both a media converter and RF overlay, which

combines the digital services with the analogue signals. This

means that TV, internet and other services are delivered over

the same network - an optimal solution now and in the future.

The TV/FM converter has a built-in Optical AGC, which enables

a constant RF output independent of minor optical fluctuations

or level changes that can be caused by product lifetime or

environmental changes.

General Units Data Notes

Supply voltage VAC 100 - 240 **

Operating temperature ºC 0 - 55 †

Power consumption W < 6

Dimensions mm 240 x 210 x 60 +

Weight kg 0.8

Colour White

9

* Measured at -6 dBm optical input, CENELEC 42 channels. OMI 4 %

** Internal power supply.

† Support for extended temperature range on request.

+ 185 x 180 x 55 without trim cover.

‡ 10/100 for 79101, 100/1000 for 79102.

†† Upon request.

TV/FM Converter Units Data Notes

Optical wavelength nm 1310 … 1550

Max optical input level dBm 3

Operational optical input level (sensitivity) dBm -10 … -3

RF bandwidth MHz 45-862

RF output level dBµV 88 *

RF flatness dB +/- 1

CNR (Carrier-to-noise) dB >50 *

CSO (Composite Second Order) dB >60 *

CTB (Composite Triple Beat) dB >60 *

Optical indicator LED dBm < -10: red > -10: green

RF connector, impedance F-female 75 Ω

Optical connector SC/APC

Media converter Units Data Notes

Optical wavelength nm 1310…1550 - Bidirectional or two fibre

Speed (LAN) Mbps 10/100 or 10/100/1000 ‡

Speed (optical) Mbps 100/1000 full duplex ‡

Operational optical input level dBm -33 … -3

Max optical input level dBm -3

LAN ports RJ-45 1 / 2 / 4 ††

Optical connector SC/PC

EMC Immunity: EN55024:1998+A1:2001+A2:2003EMC emiision: EN55022:1998+A1:2000+A2:2003Low voltage directive: 2006/95/ECi,EN609501

Page 10: FTTH CPE Gateway Dktc Omega

Advantages

- Analogue / digital management - the all-in-one solution- Complete control over all services- Easy upgradable, remotely- Flexible network interface, both hardware and software- Flexible design - configurable- Unique customer configuration settings

Page 11: FTTH CPE Gateway Dktc Omega

ftth cpe gateway with management

Product informationWith SNMP management the CPE gateway can be controlled via the

network with a wide variety of services. By adding management it

is possible to control the CPE gateway and thereby check status,

perform trouble shooting and update the CPE without the need to

make service calls.

To future-proof the CPE gateway it is possible to perform remote

software configurations and firmware upgrades. This can be done

either automatically when the gateway is rebooted, or on the fly by

the network administrator remotely connecting to the CPE gateway.

Also, the unique customer settings features means that operators

have a flexible way to provide services to the individual subscriber.

To control the provided services it is possible to turn the digital signal

on and off at the different LAN ports and to control the up- and

download speeds of the individual LAN port. Combined with VLAN

(IEEE 802.1Q) it is possible to assign different tasks to individual

ports; for example making one port destined for IPTV, one for VoIP

and one for internet. The management also allows remote trouble

shooting on the internet connection (fault locating), because it is

possible to monitor status, uptime and statistics of traffic

The DKTCOMEGA CPE gateway is offered with or without the RF

overlay (TV/FM). By adding management it is possible to turn the

RF module on/off and to monitor the quality of the TV/FM service,

making trouble shooting both in the network as well as in the

households much easier. Furthermore, the gateway is available in

two variants, 4 x 10/100 (item no. 79204) and 4 x 100/1000 (item no.

79403).

11

For information regarding the Media converter and TV/FM converter refer to page 9.

Management Data

SNMP management SNMP v1, SNMP v2

TFTP Client Software download, remote configuration

DHCP Configuration support

CATV control Remote ON/OFF, monitoring of the signal level

VLAN Services and port separation, IEEE 802.1Q, tagging, untagging

Security MAC address Access Control List (ACL), layer 2

QoS (Quality of Service) Data

DiffServ Layer 3 (IP) QoS mechanism, 4 hardware queues for prioritization

Class of Service IEEE 802.1p, Layer 2 (Ethernet) QoS mechanism 4 hardware queues for prioritization

LAN port priority 4 hardware queues

Bandwidth shaping Rate limitation for each LAN port

IGMP snooping IGMPv2, IGMPv3

EMC Immunity: EN55024:1998+A1:2001+A2:2003EMC emission: EN55022:1998+A1:2000+A2:2003Low voltage directive: 2006/95/ECi,EN609501

Page 12: FTTH CPE Gateway Dktc Omega

Advantages

- VoIP gateway, offering triple-play services- Two FXS ports with support for five phones per line- Flexible management, remote accessibility- Flexible design - configurable

Page 13: FTTH CPE Gateway Dktc Omega

ftth cpe gateway with optional VoIP

13

Product informationBuilt upon the strong DKTCOMEGA CPE/gateway product line, this is

a new series of gateways that offers true triple-play services to the

premises.

The gateway offers data services, analog telephony (VoIP ATA)

and CATV services in a single box. It can be remotely managed by

operators, thereby providing configuration flexibility and integration

with access networks.

The VoIP gateway option has two RJ-11 FXS/POTS ports. The plug-in

module can be installed in the 10/100 Mbps LAN & 100 Mbps WAN CPE

(79204) or in the 10/100/1000 Mbps LAN & 100/1000 Mbps WAN CPE

(79403). It is a plug-and-play option that does not require operator

assistance and thereby reduces operating costs.

The VoIP option is based upon SIP 2.0 signaling with an RTP/RTCP data

service. This allows normal analogue telephones to connect to the

CPE, where the service can handle two individual lines each with up

to five phones.

The VoIP gateway option makes it is easy for operators to offer triple-

play services to consumers. Built-in management allows for controlling

the CPE gateway, especially for configuring, status checking,

troubleshooting and updating the CPE without having to make service

calls.

The DKTCOMEGA CPE gateway is offered with the RF overlay (TV/

FM) as an option. Using management it is possible to activate and

deactivate the RF module.

For information regarding the Media converter refer to pages 9 and 11.

VoIP (plug-in module) Data

User ports LAN: Item 79204: 4 x 10/100 Base-TX (RJ-45)Item 79403: 4 x 100/1000 Base-TX (RJ-45)2 VoIP FXS ports (RJ-11, POTS)

VoIP Protocol SIP 2.0

VoIP Ports G.711 a-law / u-lawG.729Automatic Fax/Modem Detection (future)Caller IDMessage Waiting IndicationAdaptive jitter bufferMaximum load per port: 5 RENRTP voice packet encapsulation

EMC Immunity: EN55024:1998+A1:2001+A2:2003EMC emission: EN55022:1998+A1:2000+A2:2003Low voltage directive: 2006/95/ECi,EN609501

Page 14: FTTH CPE Gateway Dktc Omega
Page 15: FTTH CPE Gateway Dktc Omega

features / benef its

Modular designThe DKTCOMEGA series of CPE gateways is designed in a

modular fashion. The standard modules include the

plastic gateway and the power supply, the other modules

are fully customizable with a range or different media

converters and of course the choice of TV/FM converter

with and without filter functionality.

DesignThe plastic enclosure has been developed in close

cooperation with operators and Danish designers and it

provides even more advantages to both the service pro-

vider and subscriber. The look of the gateway is charac-

terized by the welded lid, which fits perfectly into the

modern home, and in addition hides the control diodes

on the CPE. The gateway itself was designed for easy

installation and for optimal protection of the fibre. This

is achieved by the integrated fibre management and flex-

ible fibre access from all sides of the box including the

back side.

Power supplyThe integrated power supply is specifically designed

for long service life with the goal of minimizing service

calls. The unit is robust both in terms of potential

impact during transport, the durability after instal-

lation and the ability to handle power fluctuations.

15

Page 16: FTTH CPE Gateway Dktc Omega

references

IntroductionDKTCOMEGA has since 1999 gained a long and extensive

experience in supplying CPE gateways for small, medium

and large FTTH networks ranging from 50 – 360,000

potential homes passed. Our experience stems from

foreign and domestic projects with standard and custom-

ised solutions.

Profiber (Denmark)Profiber is a co-operation between three large utility

companies in Denmark, which will be offering a FTTH

connection to all utility customers in their area, which

includes municipalities, households and private busi-

nesses.

Potential homes passed: 360,000

CPE gateway: Customised CPE gateway with MC and RF

overlay

Start-up: 2005

Other: The CPE gateway supplies 100/1000 Mbps with

auto switching since 2007

Danish Broadband (Dansk Bredbånd - Denmark)Danish Broadband is one of the leading operators of fibre

optical networks in Denmark. In close co-operation with

different utility companies they supply triple play and

on-demand services to households, municipalities and

private businesses.

Current homes passed: about 30.000 households

CPE gateway: Customised CPE gateway with MC and RF

overlay and customised CPE gateway with MC

Start-up: 2000

Dynamo Net (Finland)Dynamo Net was initiated by the municipality of Närpes

in order to build a regional fibre optical and wireless

network. Now the network connects the towns in the mu-

nicipality offering public offices, businesses and private

households triple play and different on demand services.

Potential homes passed: 700 households

CPE gateway: Customised CPE gateway with MC and RF

overlay

Start-up: 2004

Page 17: FTTH CPE Gateway Dktc Omega

glossary

17

SNMP (Simple Network Management Protocol) is used by network management systems to monitor network-attached devices for conditions that warrant administrative attention. It consists of a set of standards for network manage-ment, including an Application Layer protocol, a database scheme, and a set of data objects.

TFTP (Trivial File Transfer Protocol) is a very simple file transfer protocol with the functionality of a very basic form of FTP. It is easy to implement in a small amount of memory, and it is therefore useful for products with no data storage devices. In a CPE gateway it is used to make remote software configuration and fetch CPE configuration.

DHCP (Dynamic Host Configuration Protocol) is a set of rules used by communication devices such as a computer, router or network adapter to allow the device to request and obtain an IP address and other parameters such as the default gateway, subnet mask, and IP addresses of DNS servers from a DHCP server.

VLAN (Virtual Local Area Network) is a method of creating independent logical networks within a physical network. This helps in reducing the broadcast domain and assists in network administration by separating logical segments of a LAN that should not exchange data using a LAN. With a CPE gateway it can be used to dedicate one port to be used solely for IPTV or VoIP.

QoS (Quality of Service) refers to control mechanisms that can provide different priority to different users or data flows, or guarantee a certain level of performance to a data flow in accordance with requests from the application program or the internet service provider policy. Quality of Service guarantees are important especially for real-time streaming multimedia applications, such as voice over IP and IP-TV, since these often require a fixed bit rate and may be delay-sensitive.

DiffServ (Differentiated Services) is a computer networking architecture that specifies a simple and scalable mecha-nism for classifying, managing network traffic and providing quality of service guarantees on modern IP networks. DiffServ can be used to critical network traffic such as voice or video while providing simple best-effort traffic guar-antees to non-critical services such as web traffic or file transfers.

Class of Service (CoS) is a 3 bit field within a layer two Ethernet frame header when using IEEE 802.1Q. It is a way of managing traffic in a network by grouping similar types of traffic (for example VoIP) together and treating each type as a class with its own level of service priority. It specifies a priority value of between 0 (best-effort) and 5 (priority real-time data) that can be used to differentiate traffic.

Layer 3 is a part of the OSI seven layer model – a layered, abstract description for communications and computer network protocol design. Layer 3 is the network layer, which performs network routing functions and report delivery errors. The best known example of a layer 3 protocol is the Internet Protocol (IP).

Traffic shaping is an attempt to control network traffic in order to optimize or guarantee performance, low latency, and/or bandwidth by delaying packets. Traffic shaping deals with the concepts of classification, queue disciplines, enforcing policies, congestion management, quality of service, and fairness.

Customer Premises Equipment (CPE) – Any equipment provided to the customer at their premises.

Quadrature amplitude modulation (QAM) is a modulation scheme which conveys data by changing (modulating) the amplitude of two carrier waves. These two waves, usually sinusoids, are out of phase with each other by 90º and are thus called quadrature carriers.

Quadrature Phase Shift Keying (QPSK): Used to modulate digital information onto an RF carrier when satellite trans-ponders are used to transmit MPEG 2 signals. Rather than using the amplitude or frequency of the carrier to convey the information, QPSK modulates the phase of the carrier signal. Depending on the data being modulated, the carrier is forces into one of four different phase states known as a symbol.

Digital Video Broadcast via cable (DVB-C)

Digital Video Broadcasting for Terrestrial (DVB-T)

Digital Audio Broadcasting, also known as digital radio (DAB)

Page 18: FTTH CPE Gateway Dktc Omega