(ft-ir) and raman spectroscopy

17
1 Center for Electrochemical Engineering Research ABC’s of Electrochemistry Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopy Dan Wang 10/06/11

Upload: vudieu

Post on 12-Jan-2017

257 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: (FT-IR) and Raman Spectroscopy

1 Center for Electrochemical Engineering Research

ABC’s of Electrochemistry

Fourier Transform Infrared Spectroscopy (FTIR)

and

Raman Spectroscopy

Dan Wang

10/06/11

Page 2: (FT-IR) and Raman Spectroscopy

2 Center for Electrochemical Engineering Research

Background (IR)

Friedrich Wilhelm Herschel

(1738 –1822)

In 1800, Herschel analyzed the spectrum of sunlight. He

got a higher temperature just beyond the red light region

than that of visible spectrum. He conclude there must be

an invisible light beyond visible region. This kind of light

became known as infrared light.

Page 3: (FT-IR) and Raman Spectroscopy

3

Background (Raman)

Center for Electrochemical Engineering Research

(1888 –1970)

Chandrasekhara Venkata

Raman

1928, Raman discovered the Raman effect

(Raman scattering ) through his experiments on

the scattering of light.

He won the Nobel Prize in Physics in 1930 due

to the discovery of Raman scattering.

Page 4: (FT-IR) and Raman Spectroscopy

4

Raman scattering

Center for Electrochemical Engineering Research

elastic

Incident light

(laser)

inelastic The Raman effect comprises a very small fraction of

the incident photons (approximately 1 in 107).

Page 5: (FT-IR) and Raman Spectroscopy

5 Center for Electrochemical Engineering Research

Raman spectroscopy and instrument

Raman spectroscopy is a spectroscopic technique

based on inelastic scattering of monochromatic

light (a laser source), study vibrational modes in a

system.

The combination of Raman spectrometer and

confocal microscope allows for obtaining the

information of both morphological details and

molecular structures.

Page 6: (FT-IR) and Raman Spectroscopy

6 Center for Electrochemical Engineering Research

Optical Path of Raman Spectroscopy Measurements

Bruker Senterra

Page 7: (FT-IR) and Raman Spectroscopy

7

Fourier Transform Infrared Spectroscopy (FTIR)

Center for Electrochemical Engineering Research

•Fourier transform infrared spectroscopy (FTIR spectroscopy) is the

spectroscopy that deals with the infrared region of the

electromagnetic spectrum.

•FTIR spectrometer simultaneously collects spectral data in a wide

spectral range.

•FTIR spectroscopic analysis is to identify the chemical functional

groups in the sample.

Near-IR, approximately 14000–4000 cm−1 (0.8–2.5 μm wavelength)

Mid-IR, approximately 4000–400 cm−1 (2.5–25 μm)

Far-infrared, approximately 400–10 cm−1 (25–1000 μm),

http://en.wikipedia.org/wiki/Fourier_transform_infrared_spectroscopy

Page 8: (FT-IR) and Raman Spectroscopy

8

Sample Preparation for IR spectroscopy

Center for Electrochemical Engineering Research

1. Pressing KBr Pellet:

solid samples,

sample concentration in KBr : 0.2%~1%

A translucent pellet: thickness :0.5~1 mm

2. Thin film between two IR transparent plates:

liquid sample and soluble solid powder

KBr, NaCl, CaF2 plates

The space between plates: typically < 0.01 mm

3. Preparing a Mull

Solid sample can be ground into fine particles but not soluble in solvent

Mulling agent: Nujol, paraffin oil

interference from the absorption bands of the mulling agent

4.Others:

Liquid cell: volatile liquid

Gas cell: gaseous sample

No sample preparation: self supporting thin film,

Attenuated total reflectance (ATR)-FTIR

Page 9: (FT-IR) and Raman Spectroscopy

9

Degrees of freedom

Center for Electrochemical Engineering Research

•Both IR and Raman spectroscopy characterize the vibrations of

chemical bonds.

•The number of vibrations in a molecule related to the degrees of

freedom which the structure possesses.

Nonlinear molecules: 3n-6; for example: H2O 3X3-6=3

Linear molecules: 3n-5; for example: CO2 3X3-5=4

Minus 3 degrees of translational freedom

Minus 3 degrees of rotational freedom

A molecule has n atoms. Totally 3n degrees of freedom (x, y, z axis.)

Page 10: (FT-IR) and Raman Spectroscopy

10

Selection Rules

Center for Electrochemical Engineering Research

IR active: the vibration results in a change in the

dipole moment.

IR inactive: for example

•Homonuclear molecules: O2, N2, Cl2, have no net

charge in dipole moment occurs during the vibration.

•symmetric stretch of O=C=O (linear molecule)

For example

•Unsymmetrical diatomic molecules, e.g. CO

• non-linear molecule like H2O

• asymmetric stretch of O=C=O

Page 11: (FT-IR) and Raman Spectroscopy

11

Raman active

Center for Electrochemical Engineering Research

Raman active: molecule’s polarizability must change

during the vibration

O-C-O O C O O C O

For example: symmetric stretch of O=C=O

Page 12: (FT-IR) and Raman Spectroscopy

12

Raman spectra VS IR spectra

Center for Electrochemical Engineering Research

Skoog, Hollier & Nieman, 5th edn, 1998, Fig. 18-3

Infrared and Raman spectroscopy are used as complementary techniques.

Page 13: (FT-IR) and Raman Spectroscopy

13

IR VS Raman

Center for Electrochemical Engineering Research

• Scattering spectroscopy

• Polarizability change

•Minimal or no sample preparation

• No interference from atmospheric

CO2 or H2O

IR Raman

• Absorption spectroscopy

•Dipole moment change

•Sample preparation is mostly

required

•Interference with the

measurement environment

Page 14: (FT-IR) and Raman Spectroscopy

14

Related Raman / IR spectroscopies

Center for Electrochemical Engineering Research

1. Surface-Enhanced Raman Spectroscopy (SERS): a surface-

sensitive technique that enhances Raman scattering by molecules

adsorbed on rough metal surfaces. (Usually silver or gold). The

enhancement factor can be up to 1011.

2. Resonance Raman Spectroscopy: The excitation wavelength is

matched to an electronic transition of the molecule or crystal, so that

vibrational modes associated with the excited electronic state are

greatly enhanced.

3. Attenuated total reflectance (ATR)-FTIR: avoids the problem of

strong attenuation of the IR signal in highly absorbing media, such

as aqueous solutions.

http://en.wikipedia.org/wiki/Raman_spectroscopy

Page 15: (FT-IR) and Raman Spectroscopy

15

Spectroelectrochemistry

Center for Electrochemical Engineering Research

Raman spectroscopy and FTIR spectroscopy combined with electrochemical

methods are powerful techniques for the mechanism and kinetics study,

because they can provide fundamental molecular level information and detect

intermediate adsorbates on the electrode surface during the reactions.

• An accurate polarization control mode

can be applied with the aid of a

potentiostat while simultaneously

performing Raman spectroscopy.

• The center of the cell top is a piece of

cover glass, which allows the Raman

excitation laser beam to go through the cell

and electrolyte onto the electrode surface.

Spectroelectrochemical cell

Page 16: (FT-IR) and Raman Spectroscopy

16

Resources

Center for Electrochemical Engineering Research

• Principles of instrumental analysis, Belmont, CA :

Thomson Brooks/Cole, c2007, 6th ed. / Douglas A.

Skoog, F. James Holler, Stanley R. Crouch

• OPUS software-----Help----- FTIR tutorial

Page 17: (FT-IR) and Raman Spectroscopy

QUESTIONS?

www.ohio.edu/engineering