FSD 01 Detectors Simulation Vs Measurements
Sudip Chatterji and Indian Students(Ghosh P, Bansal Y, Joshi N and Sharma N )
GSI Helmholtz Centre for Heavy Ion Research GmbHSTS Work Group Meeting
10th January 2012
Outline
1. Motivation2. Simulation Vs Measurements
Fluence 1e12 n/cm2
Fluence 1e13 n/cm2
Fluence 3e13 n/cm2
Fluence 1e14 n/cm2
3. Overview & Analysis
1. Motivation
• To study and verify the FSD Detectors IV & CV Characteristics
• To verify the Simulation module for FSD parameters using the models used previously
• Role of space charge effect on the Breakdown voltages• To study and validate different models for annealing
parameter.– To extract Annealing time constants
2.1.1 Simulation Vs Measurements Fluence ø=1e12(n/cm2)
2.1.2 Simulation Vs Measurements Fluence ø=1e12(n/cm2)
• VFD{Measured} ~ 40V
• VFD{Simulated} ~ 44V
• Leakage current almost comparable
• Simulation results holds good
2.2.1 Simulation Vs Measurements Fluence ø=1e13(n/cm2)
2.2.2 Simulation Vs Measurements Fluence ø=1e13(n/cm2)
• VFD{Measured} ~ 12V
• VFD{Simulated} ~ 15V
• Leakage current almost comparable
• Simulation results almost holds good
2.3.1 Simulation Vs Measurements Fluence ø=3e13(n/cm2)
2.3.2 Simulation Vs Measurements Fluence ø=3e13(n/cm2)
• Pink curve => Good Detector – VFD{Measured} ~80 V
– VFD{Simulated} ~ 90V
– Leakage current almost comparable, Simulation results almost holds good
• Red curve => Bad Detector – VFD{Measured} ~ not observed
– Leakage Current much higher than expected.
2.4.1 Simulation Vs Measurements Fluence ø=1e14(n/cm2)
2.4.2 Simulation Vs Measurements Fluence ø=1e14(n/cm2)
• VFD{Measured} & {Simulated} = not observed
• BD {Measured} = 220V • BD {Simulated} = 250V• Leakage current almost
comparable but• Breakdown appear early in
measurements (red & green)• Impact of Qf Observed
– Increasing the Qf Decreases Break Down voltage ( blue to pink ~ 8e11 1e12)
– May be the Qf ~ 3e12 in measured Detectors
3.1 Simulation Vs MeasurementOverview
Measured Values for FSD 01 Simulated Values for FSD 01
3.2 Simulation Vs MeasurementAnalysis
• Simulation results holds good with results from FSD01 Detectors.
• Leakage current is comparable in both the cases • VFD{Measured} ~ VFD{Simulated}
• Type inversion observed after Fluence=1e13 n/cm2
• With some bad detectors, statistics in case of detectors becomes important to verify the simulation results.