FSC-25N CHANNEL GUARD
24FSC25N
SECTIONAL VIEW
PLEASE READ
PLEASE READ THESE INSTRUCTIONS THOROUGHLY
PRIOR TO BEGINNING THE FSC-25N CHANNEL
GUARD INSTALLATION!
THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE
A SPECIFIC GUIDE TO FOLLOW FOR THE
INSTALLATION OF FSC-25N CHANNEL GUARD.
CONTAINED WITHIN IS THE THE TECHNICAL
INFORMATION AND INSTALLATION TECHNIQUES
REQUIRED TO COMPLETE AN EFFICIENT, NEAT AND
LONG-LASTING INSTALLATION.
INSPECT ALL MATERIALS FOR DAMAGE OR MISSING
PARTS. IF YOU DISCOVER DAMAGED OR MISSING
MATERIALS, IN THE USA PLEASE NOTIFY THE
FACTORY AT (800) 233-8493, AND IN CANADA (888)
895-8955.
FSC-25N CHANNEL GUARD MUST BE INSTALLED IN
ACCORDANCE WITH THESE INSTRUCTIONS! FAILURE
TO FOLLOW THESE INSTRUCTIONS MAY VOID ANY
PRODUCT WARRANTIES AND RESULT IN AN
UNSUCCESSFUL INSTALLATION. FOR SPECIFIC
QUESTIONS REGARDING THE INSTALLATION OF
FSC-25N CHANNEL GUARD PLEASE CALL THE
FACTORY IN THE USA AT (800) 233-8493 OR EMAIL
[email protected]. IN CANADA
CALL (888) 895-8955.
IMPORTANT NOTES
1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER IN LENGTHS UP TO 20'-0" AND ACROVYN COVERS IN
LENGTHS UP TO 10'-0". THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO INSURE THAT ALL CUTS ARE SQUARE.
WHEN CUTTING MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT,
TO MINIMIZE CHIPPING AND MAINTAIN JOINT ALIGNMENT.
2. ALL DIMENSIONS ARE TYPICAL.
3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD
STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS
THAT DO NOT ALLOW FOR ATTACHMENT FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY
HAVING JURISDICTION.
4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION
AND CONTRACTION OF MATERIAL.
5. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com.
STUD
WIDTH
FOAM TAPE
G.W.B.
(BY OTHERS)
DRYWALL
SETBACK
STEEL/WOOD
STUD
(BY OTHERS)
2"
[51.2mm]
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17
FSC-25N (1/2" DRYWALL)FSC-25N (5/8" DRYWALL)
FSC-25N (2 LAYERS
OF 5/8" DRYWALL)
FSC-25N (2 1/2" STUD WALL
and 5/8" DRYWALL)
FSC-25N CHANNEL GUARD
SECTIONAL VIEWS
24FSC25N
STUD WIDTH STUD WIDTH
STUD WIDTH
STUD WIDTH
2"
[51.2mm]
1 5/8"
[41.3mm]
DRYWALL
SETBACK
FOAM TAPE
STEEL/WOOD
STUD
(BY OTHERS)
G.W.B.
(BY OTHERS)
STEEL/WOOD
STUD
(BY OTHERS)
STEEL/WOOD
STUD
(BY OTHERS)
FOAM TAPE FOAM TAPE
STEEL/WOOD
STUD
(BY OTHERS)
G.W.B.
(BY OTHERS)
1 3/4"
[44.6mm]
DRYWALL
SETBACK
FOAM TAPE
G.W.B.
(BY OTHERS)
1 5/8"
[40.6mm]
DRYWALL
SETBACK
2"
[51.2mm]
G.W.B.
(BY OTHERS)
2"
[51.2mm]
1 5/8"
[41.3mm]
DRYWALL
SETBACK
2"
[51.2mm]
R1/4"
[R6.4mm]
R1/4"
[R6.4mm]
R1/4"
[R6.4mm]
R1/4"
[R6.4mm]
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17
WALL CONDITION SPECIFIED FASTENER
DRILL DIAMETERS
CS PART
NUMBER
WALL RETAINER
SINGLE LAYER DRYWALL #6 X 1-5/8" BUGLE HEAD SHEET METAL SCREW N/A N/A 90H079002
DOUBLE LAYER DRYWALL #8 X 3" BUGLE HEAD SHEET METAL SCREW N/A N/A 90H857002
FSC-25N CHANNEL GUARD
COMPONENTS & WALL FASTENERS
24FSC25N
FSC-25N ACROVYN COVER FSC-25N
ALUMINUM RETAINER
(24A285000 - 1/2" DRYWALL)
(24A284000 - 5/8" DRYWALL)
GASKET
(24M013xxx)
ALUMINUM BASE
(24F013000 - 4")
(24F148000 - 6")
1" ALUMINUM
CLOSURE CAP
(24F095000)
3/4" FOAM TAPE
(90M008002C)
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17
FULL HEIGHT PARTIAL HEIGHT
STANDARD DEDUCTIONS
FSC-25N CHANNEL GUARD
24FSC25N
RETAINER
LENGTH
EQUALS
CEILING
HEIGHT
PLUS 2"
[50.8mm]
2"
[50.8mm]
BASE
HEIGHT
1/16" [1.6mm]
GASKET
COVER
LENGTH
EQUALS
RETAINER
LENGTH
MINUS
BASE
HEIGHT
AND
1/16"
[1.6mm]
FINISH CEILING
ALUMINUM RETAINER
FINISH FLOOR
RETAINER
HEIGHT
EQUALS
FINISH
HEIGHT
PLUS
1" [25.4mm]
BASE
HEIGHT
1/16" [1.6mm]
GASKET
COVER
LENGTH
EQUALS
FINISH
HEIGHT
MINUS
BASE
HEIGHT
AND
1/8" [3.2mm]
1/16" [1.6mm]
GASKET
1"
[25.4mm]
ALUMINUM CLOSURE
CAP
ALUMINUM
RETAINER
CEILING
HEIGHT
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17
FULL HEIGHT PARTIAL HEIGHT
FSC-25N CHANNEL GUARD
TYPICAL ASSEMBLY
24FSC25N
DRYWALL SETBACK CHART
1/2" THK. 5/8" THK.
5/8" (2) THK.
5/8" THK.
(2 1/2" STUD)
1 3/4"
[44.5mm]
1 5/8"
[44.5mm]
1 5/8"
[44.5mm]
1 5/8"
[44.5mm]
18"
[457.2mm]
MAXIMUM
18"
[457.2mm]
MAXIMUM
DRYWALL SETBACK
(REF. CHART BELOW)
SPECIFIED
FASTENER
ALUMINUM
RETAINER
G.W.B.
(BY OTHERS)
STEEL/WOOD STUD
(BY OTHERS)
PRE-PUNCHED
HOLES
BLACK ACROVYN GASKET
ALUMINUM BASE
FOAM TAPE
ACROVYN
COVER
BLACK ACROVYN
GASKET
ALUMINUM BASE
FOAM TAPE
ACROVYN
COVER
PRE-PUNCHED
HOLES
STEEL/WOOD STUD
(BY OTHERS)
G.W.B.
(BY OTHERS)
ALUMINUM
RETAINER
ALUM. CLOSURE CAP
REQ'D AT PARTIAL
HEIGHT APPLICATIONS
BLACK ACROVYN GASKET
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17
1. ALL FLUSH MOUNTED CORNER GUARDS ARE SHIPPED WITH
CUT-TO-LENGTH ALUMINUM RETAINERS WITH FACTORY
DRILLED HOLES IN THE RETAINER.
2. WHEN INSTALLING THE GYPSUM BOARD OR PLASTER,
CONSULT THE CHART ON PAGE 5 TO DETERMINE THE
SETBACK DISTANCE TO PROVIDE A SNUG FIT WHEN THE
RETAINER IS INSTALLED.
3. ALIGN EACH RETAINER WITH THE CORNER AND SECURE
EACH LEG THROUGH THE WALL INTO THE METAL/WOOD
STUDS USING THE SPECIFIED FASTENERS. MAKE SURE
THE RETAINER REMAINS PLUMB WITH THE FINISH FLOOR.
NOTE: FOR SINGLE LAYER DRYWALL UNITS WITH STUDS WIDER
THAN 3 5/8" OR DOUBLE GWB APPLICATIONS, THE BASE, TOP
CAP AND ASSOCIATE PARTS HAVE BEEN FACTORY SPLIT. THE
SNAP-ON BASE AND TOP CAP HAVE BEEN WELDED TO
ACCOMMODATE THE EXTRA WIDTH. THE ACROVYN GASKET IS
SHIPPED IN PARTS, WITH EXTRA PIECES INCLUDED, SO THE
INSTALLER CAN FABRICATE A WORKABLE GASKET.
4. INSERT ALUMINUM BASE CLOSURE AT THE BASE OF THE
RETAINER AND SECURE THE ACROVYN GASKET ON TOP.
ALIGN GASKET WITH OUTSIDE EDGE.
5. A 1" [25.4mm] CLOSURE CAP IS TO BE INSTALLED AT TOP OF
RETAINER ON PARTIAL HEIGHT GUARDS. FOLLOWING
PROCEDURES SIMILAR TO STEP 4.
6. APPLY 2" [50.8mm] JOINT TAPE ALONG THE EDGE OF THE
DRYWALL AND THE ALUMINUM RETAINER. FINISH THE
INSTALLATION BY APPLYING A UNIFORM FEATHERED JOINT
AT THIS LOCATION AS PER STANDARD CONSTRUCTION
PRACTICES. ALLOW TO DRY AND THEN SAND AS
REQUIRED. APPLY ADDITIONAL COATS, AS REQUIRED, TO
PROVIDE A UNIFORM AND NEAT FINISH. APPLY THE
PROCEDURE TO ANY "CLOSURE CAPS" USED ON PARTIAL
HEIGHT INSTALLATIONS.
7. FINISH WALL SURFACE AS SPECIFIED. BE SURE THAT THE
SELECTED FINISH IS APPLIED TO THE INSIDE SURFACE OF
THE REAR "CONTOURED" PORTION OF THE ALUMINUM
RETAINER.
8. APPLY A SINGLE THICKNESS OF FOAM TAPE ONTO BOTH
CORNERS AND A DOUBLE THICKNESS ALONG CENTER OF
ALUMINUM RETAINER.
NOTE: IF THE RETAINER HAS BEEN SPLIT, APPLY THE CENTER
TAPE ALONG ONE EDGE OF THE SPLIT.
9. FINISH INSTALLATION BY SNAPPING THE ACROVYN COVER
ONTO THE RETAINER.
FSC-25N CHANNEL GUARD
TYPICAL ASSEMBLY
24FSC25N
This document is the property of Construction Specialties, Inc. and contains CONFIDENTIAL PROPRIETARY INFORMATION
that is not to be disclosed to third parties and is not to be used without approval in writing from Construction Specialties, Inc.
Muncy, Pennsylvania ● (800) 233-8493 ● Fax (570) 546-5169
Mississauga Ontario ● (888) 895-8955 ● Fax (905) 274-6241
www.c-sgroup.com
ACROVYN
COVER
FOAM TAPE
DRYWALL
TAPE
FEATHERED
JOINT
WALL
FINISH
MATERIAL
BLACK ACROVYN
GASKET
COVE BASE
(BY OTHERS)
WALL FINISH
MATERIAL
2"
[51.2mm]
DRYWALL
SETBACK
(SEE CHART
ON PAGE 5)
STUD
WIDTH
Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17