front yard setback

1
Contractor to check and verify all dimensions on the job drawing title February 2016 1:400 date project number scale M. Malkov drawing number checked by plot date drawn by designed by date project north no. issue / revision FLYNN CANADA OTTAWA OFFICE BUILDING 1655 COMSTOCK RD OTTAWA, ONTARIO EXISTING VEGETATION - PRESERVATION AND REMOVALS PLAN L - 01 16 - 1489 seal M. Ruhland M. Ruhland Mar. 14/16 1 Mar. 10, 2016 2 D07-12-15-0027 3 4 5 6 16990 7 8 Issued for Site Plan Control THIS DRAWING IS INTENDED FOR MUNICIPAL SITE PLAN APPLICATION AND IS NOT A CONSTRUCTION DRAWING. THE LANDSCAPE ARCHITECT CARRIES NO RESPONSIBILITY FOR THE DRAWING IF USED FOR CONSTRUCTION PURPOSE. PROPOSED ONE STOREY WAREHOUSE / OFFICE PROPOSED FINISHED FLOOR ELEVATION: XX.XX PATIO (C 23.19 6 .19 (857&S) 6.19 UP Concrete Retaining Wall Metal Steps Concrete Base MP MP Steel Overhead Sign FH CB 1.80 Gas Meter Top of Bank Bottom of Bank Bottom of Bank Top of Bank Bottom of Bank Top of Bank Top of Bank Top of Bank Bottom of Bank Top of Bank Top of Bank Bottom of Bank Bottom of Bank Top of Bank UP UP UP 70.38 CB UP UP UP UP Hydro Transformer CB FP FP FP FP Guy Pole BP Gravel 70.50 70.61 70.69 70.80 70.82 70.94 71.11 71.04 71.07 70.91 MH (Top=71.14) Inv.=67.83 MH (Top=71.14) Inv.=68.59 Gravel Lane (To Substation) Ditch Inlet/ CB (Top=70.18) Inv.=69.59 A s p h a l t 0.200 Dia. Watermain 0.250 Dia. Sanitary Sewer 0.600 Dia. Storm Sewer Centreline of Ditch Centreline of Ditch Fill Stockpile Centreline of Ditch Electrical Outlet Lamp Standard Finished Floor Elev=70.55 (Concrete) Gate Finished Flo Elev=70.53 (Door Thres Hydro Conduit REAR YARD SETBACK FRONT YARD SETBACK FRONT YARD SETBACK MINIMUM LANDSCAPED AREA DC WALKWAY FH 1 DC REAR YARD SETBACK LOADING 7m x 3.5m GARBAGE ENCLOSUR E REMOVE EXISTING ENTRANCE CURB. NEW CONCRETE CURB REMOVE NEW PAINTED PARKING LINES 8 9 NEW CHAIN LINK FENCE BUILDIN G SIGN 1 21 GRAVEL 19 20 23 NEW 1,830mm HIGH CHAIN LINK FENCE 2x40cm DBH ELM POOR CONDITION (BARK DAMAGED) 25cm DBH MAPLE POOR CONDITION (BARK DAMAGED) 16&25cm DBH MAPLE FAIR CONDITION 30cm DBH MANITOBA MAPLE FAIR CONDITION 20-30 SAPLINGS MANITOBA MAPLE & ELM DOGWOOD SHRUBS SUMAC SHRUBS FAIR/GOOD CONDITION 7x5-15cm DBH MANITOBA MAPLE SAPLINGS FAIR/GOOD CONDITION ROSE SHRUB 12x5-15cm DBH ELM, CHOKECHERRY SHRUBS FAIR/GOOD CONDITION 18cm DBH ELM, POOR CONDITION 22cm DBH POPLAR FAIR/GOOD CONDITION 15x5-15cm DBH ELM, MANITOBA MAPLE DOGWOOD SHRUBS FAIR CONDITION 18x5-15cm DBH POPLAR, MANITOBA MAPLE SAPLINGS,CHOKECHERRY SHRUBS FAIR CONDITION 25cm DBH POPLAR FAIR/GOOD CONDITION 25cm DBH POPLAR CRACKED KNOCKED DOWN POOR CONDITION 20cm DBH POPLAR FAIR/GOOD CONDITION 8cm DBH POPLAR MISSING BARK FAIR/GOOD CONDITION 25cm DBH POPLAR FAIR/GOOD CONDITION 20cm DBH POPLAR FAIR/GOOD CONDITION 1x9cm DBH MAPLE 1 CHOKECHERRY SHRUB WEEDY, FAIR CONDITION 5x5cm DBH ELM & MAPLE WEEDY, FAIR CONDITION ELM SAPLINGS TREE PROTECTION FENCE 2x2cm DBH MAPLE FAIR CONDITION TO BE REMOVED 4cm DBH ELM YOUNG TREE TO BE REMOVED 10x5-15cm DBH MANITOBA MAPLE & ELM SAPLINGS, CHOKECHERRY & DOGWOOD SHRUBS TO BE REMOVED 45cm DBH COTTONWOOD GOOD CONDITION TO BE REMOVED 30cm DBH BALSAM POPLAR FAIR/GOOD CONDITION TO BE REMOVED 25cm DBH BALSAM POPLAR FAIR/GOOD CONDITION TO BE REMOVED 4x25cm DBH BALSAM POPLAR FAIR/GOOD CONDITION TO BE REMOVED 20cm DBH BALSAM POPLAR FAIR/GOOD CONDITION TO BE REMOVED 75cm DBH COTTONWOOD SIGNIFICANT - FAIR CONDITION, OVERHANGING BRANCHES / TRUNK TO BE REMOVED 3x5cm DBH ELM GOOD CONDITION 5cm DBH WILLOW FAIR CONDITION TO BE REMOVED 20cm DBH ELM TOP CHOPPED FOR O/H HYDRO TO BE REMOVED 15cm DBH WILLOW GOOD CONDITION TO BE REMOVED 17cm DBH WILLOW GOOD CONDITION TO BE REMOVED 5x5-10cm DBH POPLAR/WILLOW SAPLINGS DENSE THICKET OF CHOKECHERRY SHRUBS - FAIR CONDITION TO BE REMOVED 8 CHOKECHERRY SHRUBS TO BE REMOVED 2x15cm DBH MAPLE POOR CONDITION (BARK DAMAGED) TO BE REMOVED DOGWOOD SHRUBS TO BE REMOVED 40cm DBH MAPLE Sp. FAIR/GOOD CONDITION TO BE REMOVED 43 Eccles Street, 2nd Floor - Ottawa, Ontario, K1R 6S3 tel. 613.224.0095 fax 613.224.9811 TREE PROTECTION DETAIL 38x38x2400mm 'T' RAIL 3000 o.c. max 1200 mm PLASTIC SNOW FENCE (ORANGE), PLACED ±300mm ABOVE GRADE WHERE ROOT CUTTING IS NOT TO TAKE PLACE. NOTES: 1. PROVIDE PROTECTION FOR TREES SHOWN AS REQUIRING PROTECTION ON CONTRACT DRAWINGS USING METHOD SHOWN. WHERE OPERATIONS THREATEN OTHER NEARBY TREES, APPLY SAME MEASURES. 2. PROTECT ROOTS OF ALL TREES AS SHOWN ABOVE. NO EXCAVATION, FILLING, STORAGE OF MATERIALS, DISPOSAL OF CHEMICALS , VEHICLE TRAFFIC, OR OTHER ACTIVITY WHICH COULD CAUSE DISTURBANCE OF SOIL ROOT AREA, INCLUDING SOIL COMPACTION SHALL TAKE PLACE WITHIN THE PROTECTED AREA. EXISTING GRADE 1200 1200 EXISTING TREE THE CITY OF OTTAWA TREES BY- LAW REQUIRES THAT CONTRACTORS WORKING NEAR TREES MUST: - ERECT A FENCE AT THE CRITICAL ROOT ZONE (CRZ) OF TREES; - NOT PLACE ANY MATERIAL OR EQUIPMENT WITHIN THE CRZ OF THE TREE; - NOT ATTACH ANY SIGNS, NOTICES OR POSTERS TO ANY TREE; - NOT RAISE OR LOWER THE EXISTING GRADE WITHIN THE CRZ WITHOUT APPROVAL; - TUNNEL OR BORE WHEN DIGGING WITHIN THE CRZ OF A TREE; - NOT DAMAGE THE ROOT SYSTEM, TRUNK OR BRANCHES OF ANY TREE; - ENSURE THAT EXHAUST FUMES FROM ALL EQUIPMENT ARE NOT DIRECTED TOWARDS ANY TREE'S CANOPY. CRITICAL ROOT ZONE (CRZ) OF A TREE: D (DIAMETER OF TRUNK IN CENTIMETERS) X 10CM = CRITICAL ROOT ZONE.THE CRITICAL ROOT ZONE IS ESTABLISHED AS BEING 10 CENTIMETRES FROM THE TRUNK OF A TREE FOR EVERY CENTIMETRE OF TRUNK DIAMETER. THE TRUNK DIAMETER IS MEASURED AT A HEIGHT OF 1.2 METRES FOR TREES OF 15 CENTIMETRES DIAMETER AND GREATER AND AT A HEIGHT OF 0.3 METRES FOR TREES OF LESS THAN 15 CENTIMETRES DIAMETER. THE CONTRACTOR MUST OBTAIN ALL PERMITS AND APPROVALS PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR MUST CALL A CITY TREE INSPECTOR WHEN WORK IS REQUIRED NEAR A CITY TREE. REFER TO: Municipal Trees and Natural Areas Protection By-law No. 2006 - 279 Tree Protection By-law No. 2006-279 EXISTING TREE ROW TOP VIEW PLACE FENCE AT OUTSIDE EDGE OF CRITICAL ROOT ZONE 38x38x2400 mm STEEL POST 1200 mm PLASTIC SNOW FENCE LEGEND: VOLUNTEER VEGETATION PERENNIALS, GRASSES, BURDOCK DECIDUOUS SHRUBS CHERRY, DOGWOOD, ROSE, SUMAC TREES COTTONWOOD, ELM, MAPLE, POPLAR, WILLOW VEGETATION TO BE REMOVED TREE PROTECTION FENCE REMOVAL OF 75CM DBH COTTONWOOD POPLAR IS PROPOSED DUE TO PROXIMITY TO EXIT AND OVERHANGING BRANCHES WHICH WOULD POSE A SAFETY HAZARD TO VEHICULAR TRAFFIC. DEAD WOOD NOTED IN CENTRE OF CROWN. 0 5 10 15 20 25 m

Upload: others

Post on 04-Dec-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FRONT YARD SETBACK

Contractor to check and verify all dimensions on the job

drawing title

February 2016

1:400

date

projectnumber

scaleM. Malkov

drawing number

checked by plot date

drawn by designed by

date

project

north

no. issue / revision

FLYNN CANADAOTTAWA OFFICE BUILDING

1655 COMSTOCK RD

OTTAWA, ONTARIO

EXISTING VEGETATION -PRESERVATION AND REMOVALS PLAN

L - 0116 - 1489

seal

M. Ruhland

M. Ruhland

Mar. 14/161

Mar. 10, 2016

2

D07

-12-

15-0

027

3

4

5

6

16990

7

8

Issued for Site Plan Control

THIS DRAWING IS INTENDED FOR MUNICIPAL SITE PLAN APPLICATION AND IS NOT A CONSTRUCTION DRAWING.THE LANDSCAPE ARCHITECT CARRIES NO RESPONSIBILITY FOR THE DRAWING IF USED FOR CONSTRUCTION PURPOSE.

PROPOSED ONE STOREYWAREHOUSE / OFFICE

PROPOSED FINISHED FLOOR ELEVATION: XX.XX

PATI

O

1 Storey Com

mercial B

uilding(B

rick & Alum

inum S

iding)(C

oncrete Block Foundation N

oted)

23.19

6.19(857&

S)

6.19

UP Concrete

Retaining Wall

MetalSteps

Fuel Tank

ConcreteB

aseM

PMP

Steel

OverheadS

ign

FH

CB

1.80

Gas

Meter

Concrete S

idewalk

Top of Bank

Bottom

of Bank

Bottom of Bank

Top of Bank

Bottom of Bank

Top of Bank

Top of Bank

Top of BankBottom of Bank

Top of BankTop of B

ank

Bottom

of Bank

Bottom of B

ankTop of Bank

UP

UP

UP

70.38

CB

UP

UP

UP

UP

Hydro

Transformer

CB

FP

FPFP

FP

WV

Guy

Pole

BP

Gravel

70.50

70.61

70.69

70.80

70.82

70.94

71.1171.0471.07

70.91

MH

(Top=71.14)

Inv.=67.83

MH

(Top=71.14)

Inv.=68.59

Gravel Lane(To Substation)

Ditch Inlet/

CB (Top=70.18)

Inv.=69.59

A s p h a l t

0.200 Dia. W

atermain

0.250 Dia. Sanitary Sew

er

0.600 Dia. Storm

Sewer

Centreline of D

itch

Centreline of D

itch

Fill Stockpile

Centreline of Ditch

ElectricalO

utlet

LampStandard

Finished FloorElev=70.55(C

oncrete)

Steel

Platform(G

rate)

Gate

Finished FloorElev=70.53(D

oor Threshold)

Hydro Conduit

RE

AR

YAR

D S

ETB

AC

K

FRO

NT YAR

D SETBAC

K

FRO

NT YAR

D SETBAC

K

MIN

IMU

M LAN

DSC

APED AR

EA

DC

WAL

KWAY

FH

1

DC

REAR YARDSETBACK

LOAD

ING

7m x

3.5m

GARBAGE ENCLOSURE

REMOVE EXISTING ENTRANCE CURB.

NEW CONCRETE CURB

REMOVE EXISTING CURB.

NEW PAINTED PARKING LINES

8

9

NEW CHAIN LINK FENCE

BUILDING SIGN

121

GRAVEL

19 20 23

NEW 1,830mm HIGH CHAIN LINK FENCE

2x40cm DBH ELMPOOR CONDITION(BARK DAMAGED)

25cm DBH MAPLE POOR CONDITION(BARK DAMAGED)

16&25cm DBH MAPLE FAIR CONDITION

30cm DBH MANITOBA MAPLE FAIR CONDITION

20-30 SAPLINGS MANITOBA MAPLE & ELMDOGWOOD SHRUBSSUMAC SHRUBSFAIR/GOOD CONDITION

7x5-15cm DBH MANITOBA MAPLESAPLINGSFAIR/GOOD CONDITION

ROSE SHRUB

12x5-15cm DBH ELM, CHOKECHERRY SHRUBSFAIR/GOOD CONDITION

18cm DBH ELM, POOR CONDITION

22cm DBH POPLARFAIR/GOOD CONDITION

15x5-15cm DBH ELM, MANITOBA MAPLE DOGWOOD SHRUBSFAIR CONDITION

18x5-15cm DBH POPLAR, MANITOBA MAPLE SAPLINGS,CHOKECHERRY SHRUBSFAIR CONDITION

25cm DBH POPLARFAIR/GOOD CONDITION

25cm DBH POPLARCRACKED KNOCKED DOWNPOOR CONDITION

20cm DBH POPLARFAIR/GOOD CONDITION

8cm DBH POPLARMISSING BARKFAIR/GOOD CONDITION

25cm DBH POPLARFAIR/GOOD CONDITION

20cm DBH POPLARFAIR/GOOD CONDITION

1x9cm DBH MAPLE1 CHOKECHERRY SHRUBWEEDY, FAIR CONDITION

5x5cm DBH ELM & MAPLEWEEDY, FAIR CONDITION

ELM SAPLINGS

TREE PROTECTION FENCE

2x2cm DBH MAPLE FAIR CONDITIONTO BE REMOVED

4cm DBH ELMYOUNG TREE

TO BE REMOVED

10x5-15cm DBH MANITOBA MAPLE & ELM SAPLINGS, CHOKECHERRY & DOGWOOD SHRUBSTO BE REMOVED

45cm DBH COTTONWOODGOOD CONDITIONTO BE REMOVED

30cm DBH BALSAM POPLARFAIR/GOOD CONDITIONTO BE REMOVED

25cm DBH BALSAM POPLARFAIR/GOOD CONDITIONTO BE REMOVED

4x25cm DBH BALSAM POPLARFAIR/GOOD CONDITIONTO BE REMOVED

20cm DBH BALSAM POPLARFAIR/GOOD CONDITIONTO BE REMOVED

75cm DBH COTTONWOODSIGNIFICANT - FAIR CONDITION, OVERHANGING BRANCHES / TRUNKTO BE REMOVED

3x5cm DBH ELMGOOD CONDITION

5cm DBH WILLOWFAIR CONDITIONTO BE REMOVED

20cm DBH ELMTOP CHOPPED FOR O/H HYDROTO BE REMOVED

15cm DBH WILLOWGOOD CONDITIONTO BE REMOVED

17cm DBH WILLOWGOOD CONDITIONTO BE REMOVED

5x5-10cm DBH POPLAR/WILLOWSAPLINGSDENSE THICKET OF CHOKECHERRY SHRUBS - FAIR CONDITIONTO BE REMOVED

8 CHOKECHERRY SHRUBSTO BE REMOVED

2x15cm DBH MAPLEPOOR CONDITION (BARK DAMAGED)TO BE REMOVED

DOGWOOD SHRUBSTO BE REMOVED

40cm DBH MAPLE Sp.FAIR/GOOD CONDITIONTO BE REMOVED

43 Eccles Street, 2nd Floor - Ottawa, Ontario, K1R 6S3tel. 613.224.0095 fax 613.224.9811

TREE PROTECTION DETAIL

38x38x2400mm 'T' RAIL 3000 o.c. max

1200 mm PLASTIC SNOW FENCE (ORANGE), PLACED ±300mm ABOVE GRADE WHERE ROOT CUTTING IS NOT TO TAKE PLACE.

NOTES:1. PROVIDE PROTECTION FOR TREES SHOWN AS REQUIRING PROTECTION ON CONTRACT DRAWINGS USING METHOD SHOWN. WHERE OPERATIONS THREATEN OTHER NEARBY TREES, APPLY SAME MEASURES.2. PROTECT ROOTS OF ALL TREES AS SHOWN ABOVE. NO EXCAVATION, FILLING, STORAGE OF MATERIALS, DISPOSAL OF CHEMICALS , VEHICLE TRAFFIC, OR OTHER ACTIVITY WHICH COULD CAUSE DISTURBANCE OF SOIL ROOT AREA, INCLUDING SOIL COMPACTION SHALL TAKE PLACE WITHIN THE PROTECTED AREA.

EXISTING GRADE

1200

1200

EXISTING TREE

THE CITY OF OTTAWA TREES BY- LAW REQUIRES THAT CONTRACTORS WORKING NEAR TREES MUST:- ERECT A FENCE AT THE CRITICAL ROOT ZONE (CRZ) OF TREES;- NOT PLACE ANY MATERIAL OR EQUIPMENT WITHIN THE CRZ OF THE TREE;- NOT ATTACH ANY SIGNS, NOTICES OR POSTERS TO ANY TREE;- NOT RAISE OR LOWER THE EXISTING GRADE WITHIN THE CRZ WITHOUT APPROVAL;- TUNNEL OR BORE WHEN DIGGING WITHIN THE CRZ OF A TREE;- NOT DAMAGE THE ROOT SYSTEM, TRUNK OR BRANCHES OF ANY TREE;- ENSURE THAT EXHAUST FUMES FROM ALL EQUIPMENT ARE NOT DIRECTED TOWARDS ANY TREE'S CANOPY.

CRITICAL ROOT ZONE (CRZ) OF A TREE: D (DIAMETER OF TRUNK IN CENTIMETERS) X 10CM = CRITICAL ROOT ZONE.THE CRITICAL ROOT ZONE IS ESTABLISHED AS BEING 10 CENTIMETRES FROM THE TRUNK OF A TREE FOR EVERY CENTIMETRE OF TRUNK DIAMETER. THE TRUNK DIAMETER IS MEASURED AT A HEIGHT OF 1.2 METRES FOR TREES OF 15 CENTIMETRES DIAMETER AND GREATER AND AT A HEIGHT OF 0.3 METRES FOR TREES OF LESS THAN 15 CENTIMETRES DIAMETER.THE CONTRACTOR MUST OBTAIN ALL PERMITS AND APPROVALS PRIOR TO THE START OF CONSTRUCTION.THE CONTRACTOR MUST CALL A CITY TREE INSPECTOR WHEN WORK IS REQUIRED NEAR A CITY TREE.

REFER TO:Municipal Trees and Natural Areas Protection By-law No. 2006 - 279Tree Protection By-law No. 2006-279

EXISTING TREE ROW

TOP VIEW

PLACE FENCE AT OUTSIDE EDGE OF CRITICAL ROOT ZONE

38x38x2400 mm STEEL POST

1200 mm PLASTIC SNOW FENCE

LEGEND:

VOLUNTEER VEGETATION PERENNIALS, GRASSES, BURDOCK

DECIDUOUS SHRUBSCHERRY, DOGWOOD, ROSE, SUMAC

TREESCOTTONWOOD, ELM, MAPLE, POPLAR, WILLOW

VEGETATION TO BE REMOVED

TREE PROTECTION FENCE

REMOVAL OF 75CM DBH COTTONWOOD POPLAR IS PROPOSED DUE TO PROXIMITY TO EXIT AND OVERHANGING BRANCHES WHICH WOULD POSE A SAFETY HAZARD TO VEHICULAR TRAFFIC. DEAD WOOD NOTED IN CENTRE OF CROWN.

0 5 10 15 20 25 m