fotona general dentistry brochure€¦ · infrared lasers, the er:yag laser has the highest...

12

Upload: others

Post on 20-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

ISO 9001:2000 - Development, production and sales of optical communication, opto- electronic and laser devices, the certification body of TÜV management service GmbH.

EN ISO 13485:2003 - Design and development, production and sales of medical surgical lasers, the certification body of TÜV product service GmbH.

EC-Certificate - Product category: Surgical lasers, MDD 93/42/EEC, Annex II.3, the certification body of TÜV product service GmbH.

ISO 13485:2003 - Design and development, manufacturing and sales of medical surgical lasers, according to CMDCAS. The certification body of TÜV AMERICA INC.

GMP - Quality system according to the US FDA regulation, CFR Title 21, Part 820.

Page 2: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

A GLOBAL NETWORK OF LASER EXPERTSOur global network of Fotona representatives and partners brings together the most capable and experienced laser experts in the world. By developing and nurturing close relationships with our partners we ensure that our products and services fulfill the most current market needs. Through our Fotona global network we guarantee exceptional customer service, support and training.

CHOOSE FOTONA, CHOOSE PERFECTIONChoosing Fotona ensures innovative solutions, superior product capabilities, technical perfection and unrivalled clinical results. Achieving unmatched levels of precision, efficacy, efficiency and safety are key to our laser systems. When you choose Fotona, you choose the highest performance, best made laser systems in the world.

A GLOBAL LEADER FOR OVER 40 YEARSSince 1964, the beginnings of laser technology, Fotona has set industry standards of excellence in laser systems for medicine, communications, industry, and defense. Our laser systems are the result of over 40 years of experience and expertise in producing high tech products for these respective fields. Consequently Fotona is a globally recognized leader and pioneer in the innovation, development and manufacture of laser systems.

ALL IN-HOUSE TECHNOLOGYTo fulfill market needs and maintain a short time-to-market Fotona continues to invest in outstanding manufacturing and R&D facilities. In-house manufacturing and stringent testing of all our systems’ components, in compliance with all applicable international standards, ensures that our laser systems are of the highest quality, reliability and durability.

The Highest Performance Best Made Laser Systems in the World

Page 3: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

FIDELIS SERIES1

FIDELISLASER

SYSTEMS

FIDELIS SERIES

Nd:YAG (infrared, 1064 nm): Most homog-enous absorption; ideal for endodontics and soft tissue cutting with simultaneous coagula-tion and disinfection.

Er:YAG (infrared, 2940 nm): Highest absorption in water and hydroxyapatite; ideal for hard tissue procedures.

TWO MAJOR WAVELENGTHS: ALLSOFT AND HARD TISSUE PROCEDURES

At the heart of the Fotona Fidelis series are two complementary wavelengths in terms of their effect on soft and hard dental tissues.

Er:YAG (2940nm)Nd:YAG (1064nm)

WAVELENGTH (nm)

ABS

ORP

TIO

N

500 1000 1500 2000 2500 3000

WaterHydroxyapatiteDesoxyhemoglobinOxyhemoglobinMelanin

Er:YAG (2940nm)Nd:YAG (1064nm)KTP (532nm)

WAVELENGTH (nm)

ABS

ORP

TIO

N

500 1000 1500 2000 2500 3000

Er:YAGNd:YAGKTP

Er:YAGNd:YAG

WaterDesoxyhemoglobinOxyhemoglobinMelanin

High Performance Technologyfor Precise, Gentle and Effective Dentistry Ensure greater patient comfort and satisfaction

Provide quicker procedures and reduce chair time

Reduce invasiveness of your treatment

Provide superior clinical results

Expand your practice with new procedures and services

Increase your patient turn-over

Revive your passion for dentistry

Combining dentistry’s two best lasers, the Fidelis series outperforms any other dental

laser system in treatment speed and versatility. Combining the hard tissue efficiency of Er:YAG

with the soft tissue precision of Nd:YAG provides patients with ultimate care. Only the innovative Fidelis concept gives you the choice to combine both lasers in one single system or acquire them

separately to suit your practice’s needs. Even more, the unique range of Fidelis IIId aesthetic upgrade packages enable you to perform a wide

range of aesthetic medical treatments.

Page 4: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

0 200 400 600 800 1000 1200 14000TIME (micro-seconds) TIME (micro-seconds)

STANDARD LASER TECHNOLOGY FOTONA VSP TECHNOLOGY

LASE

R PU

LSE

POW

ER

400 800 1200 1600

SSP (Super Short Pulse)VSP (Very Short Pulse)SP (Short Pulse)LP (Long Pulse)VLP (Very Long Pulse)

ADVANCEDTECHNOLOGY AND

EASE-OF-USE

2FIDELIS TECHNOLOGY

VSP TECHNOLOGY:PRECISION, SAFETY AND COMFORT

Variable Square Pulse (VSP) Technology moves the precision and safety of dental laser treatments to a higher level, while ensuring ultimate patient comfort and ease-of-use in all your treatments.

To assure unmatched treatment precision our VSP technology allows you to accommodate the pulse duration and energy to specific applications and your desired clinical outcome, all at the touch of a button. To provide maximum treatment safety, Fotona’s square-shaped laser pulses avoid the slow rise of laser pulse power and the even longer fall in pulse power thereby avoiding unnecessary delivery of laser energy into the target tissue. By applying a minimum of laser energy for a maximal clinical effect you ensure the comfort of your patient. Laser-based dentistry has never been as precise, safe and comfortable as now!

OPTIMIZED LASER BEAM DELIVERY SYSTEMS High-Quality Optical Fiber for VSP-shaped Nd:YAGA high-quality fiber-optic laser beam delivery system with small fiber diameter of 200 µm for endodontics and larger fiber diameters for other applications enables you to work efficiently with optimal treatment parameters.

Advanced Articulated Arm for VSP-shaped Er:YAGThe efficacy of the Er:YAG laser depends strongly on the quality of the laser beam and its laser beam delivery system. The Fidelis laser systems deliver Er:YAG laser light through a specially developed optical articulated arm. The extremely durable and reliable optical articulated arm can deliver the high-power VSP-shaped Er:YAG laser pulses for without loosing critical laser energy. The perfectly balanced arm provides you the limitless range of motion and ease-of-use you need, unmatched by any other laser beam delivery systems available today.

Page 5: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

FIDELIS PLATFORMS3

The latest Fidelis laser systems generation now includes a new intuitive touch screen navigation system with pre-set treatment programs and data storage for ultimate treatment management. All parameters are displayed and can be easily adjusted, called up from memory or saved. Furthermore, the Fidelis III laser systems include the industry’s first Tissue effect Graphical Interface (TeGI), an essential tool in laser dentistry in order to select the perfect treatment settings. TeGI provides a precise graphical indication of the laser tissue effect as you select the various treatment parameters.

All Fidelis laser systems include Energy Feedback Control (EFC) Technology which controls energy output and ensures efficient and safe operation. Electronic Spray Control (ESC) Technology allows you to adjust, save and call up the perfect water and air spray mixes for specific.

Fidelis laser systems are completely self-sufficient; they do not require external compressed air or water sources, making them uniquely mobile and versatile in your practice.

FIDELIS III GENERATION:CONVENIENCE AND SAFETY FIRST

FIDELIS LASER SYSTEMS RANGE

VERSATILE AND

UPGRADEABLE

YAG• Cavity preparation• Periodontics• Orthodontics• Surgery

Er:

IND

ICA

TIO

NS

YAG • Endodontics• Periodontics• Orthodontics• Surgery• Tooth whitening

Nd:

IND

ICA

TIO

NS

Fidelis III: family of advanced high-power laser systems.

AESTHETIC UPGRADE PACKAGES• Facial wrinkles and sun-damaged skin• Facial wrinkles and loss of skin elasticity • Unwanted hair• Vascular lesion treatments • Pigmented lesion treatments

IND

ICA

TIO

NS

SYSTEM LASER TYPE PERFORMANCE POWER SPRAY ESC EFC TeGl

Fidelis Plus III Er:YAG and Nd:YAG Advanced 20 W, 15 W Integrated • • •FidelisEr III Er:YAG Advanced 20W Integrated • • •FidelisE Er:YAG Basic 7W External •Fotona XP-2 Nd:YAG (LP and QCW) Advanced 20 W (LP), 30 W (QCW) • •

Page 6: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

0.0 0.2 0.4 0.6PULSE DURATION (msec)

ABL

ATI

ON

SPE

ED

THER

MA

L EF

FEC

T

Fotona SSP Fotona VSPStandard laserA

BLA

TIO

N S

PEED

in e

na

me

l (10

-2 m

m3 /J

)

LASER TYPE

5.7

16.6

Foto

na S

SP

Foto

na V

SP

Sta

nda

rd

LOW POWER

LONG PULSE

HIGH POWER

SHORT PULSE

13.0

FASTER

THAN A DRILL

CAVITY PREPARATION

VSP-shaped Er:YAG – The Optimal Hard Tissue LaserThe Er:YAG laser is recognized as the laser of choice for hard tissue applications in modern dentistry. Of all infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and composite fillings, without heating surrounding structures. With the added Fotona VSP Technology the Fidelis Er:YAG laser provides efficacy, precision and safety, unmatched by any other dental laser.

More Comfort and Safety at the Speed of a Mechanical DrillFidelis Er:YAG lasers provide hard tissue ablation through extremely short VSP-shaped pulses. Unlike standard mechanical drilling, or less evolved light-based solutions, almost no heat is diffused into the target tissue, since tissue laser interaction only occurs in square-shaped microsecond pulses. By thus laser drilling with maximum safety at speeds comparable to conventional means, you provide procedures that minimize discomfort for your patients.

SSP for Superior Precision and EfficiencyDuring hard tissue laser ablation laser light can be blocked by the ablation debris cloud from reaching its target, thereby reducing efficiency and precision. To maximize precision and efficiency, Fidelis’ SSP mode not only works faster than thermal diffusion inside hard tissue, but also works faster that the formation of the ablation debris cloud.

MAX Mode – Highest Performance BenefitsMAX mode is a unique combination of preset laser parameters, enabling you to enjoy the highest performance benefits from the Fidelis’ Er:YAG at the touch of a button. This mode reaches unrivalled drilling speeds and efficiency within well-defined safety limits, a feature that is especially advantageous when working through enamel. With the Fidelis’ MAX mode Fotona has effectively erased the limits of laser dentistry, enabling you to provide comfort, safety as well as unrivalled efficiency, efficacy and versatility in your treatment range to your patient.

FIDELIS APPLICATIONS4

Control of laser pulse duration with Fotona VSP technology is essential for efficient and effective laser- based dentistry, since shorter laser pulses provide faster ablation with minimal thermal side effects.

When laser ablation is faster than heat diffusion no unnecessary heat is deposited into the tissue.

When laser ablation is slow, the generated heat has time to diffuse into the tissue, potentially causing unwanted side-effects.

0.0 0.2 0.4 0.6PULSE DURATION (msec)

ABL

ATI

ON

SPE

ED

THER

MA

L EF

FEC

T

Fotona SSP Fotona VSPStandard laserA

BLA

TIO

N S

PEED

in e

na

me

l (10

-2 m

m3 /J

)

LASER TYPE

5.7

16.6

Foto

na S

SP

Foto

na V

SP

Sta

nda

rd

LOW POWER

LONG PULSE

HIGH POWER

SHORT PULSE

13.0

Page 7: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

R02: The Fotona non-contact Er:YAG handpiece. This handpiece enables you to work in an ergonomic, comfortable non-contact position not achievablewith classical dentalinstruments.

R14: The Fotona contact Er:YAG handpiece with integrated spray nozzle. Interchange-able fiber tips allow you to optimize contact optical drilling. The integrated spray nozzles make this handpiece the ideal instrument for procedures that require simultaneous coolingand moisturizing of thetarget tissue.

LASERBURR

R24: The Fotona large spot size bleaching handpiece. A sturdy, user-friendly handpiece with larger spot sizes for fast and efficient teeth whitening procedures.

R21: The Fotona Nd:YAG handpiece.A nimble, lightweight and ergonomically detailed hand- piece for delicate softtissue procedures.

5FIDELIS APPLICATIONS

Increased Patient ComfortYour patients’ overall comfort is guaranteed by limiting thermal side-effects, and eliminating the unpleasant mechanical vibrations and noise. These characteristics are especially advantageous and invaluable in pediatric dentistry and for any patients who expect optimal service from their dental practitioner.

Surface Conditioning and Increased Bonding Strength Cavity preparation procedures with Fotona VSP-shaped Er:YAG laser leave a clean cavity surface without a smear layer, and with open dentinal tubuli – not achievable in classical methods without acid etching.

Faster ProceduresNeeding only one instrument, not having to wait for anesthesia to take effect and not requiring acid etching makes cavity preparation with the Fidelis Er:YAG laser faster and more convenient than the classical methods.

Selective Elimination of Decay – Minimally Invasive DentistrySince the Fidelis Er:YAG laser ablation speed in carious lesions is higher than in healthy dentin, Fidelis Er:YAG laser helps you to be extremely selective and preserve more healthy structural tissue. Additionally, Fidelis lasers enable you to remove sub-gingival caries without gingival bleeding, thus fulfilling the strong demands of high quality and cosmetically challenging filling therapy that you want to provide your patients.

Prevention of Further DecayThe destruction of bacteria during Fidelis Er:YAG laser ablation greatly reduces the risk of bacterial infection. In addition, Fidelis laser treatment results in a significant reduction of micro-leakage compared to classical procedures.

Water Spray for Optimal Safety and Efficacy ConditionsTissue desiccation under laser light reduces laser ablation efficacy. For improved safety and efficacy, the Fidelis optical Er:YAG handpieces enable you to simultaneously cool and moisten the tooth with an internal water spray system.

Fidelis laser treatments leave no smear layer and result in drop- shaped open tubuli that provide increased composite bonding strength.

R02: The Fotona non-contact Er:YAG handpiece. This handpiece enables you to work in an ergonomic, comfortable non-contact position not achievablewith classical dentalinstruments.

R14: The Fotona contact Er:YAG handpiece with integrated spray nozzle. Interchange-able fiber tips allow you to optimize contact optical drilling. The integrated spray nozzles make this handpiece the ideal instrument for procedures that require simultaneous coolingand moisturizing of thetarget tissue.

LASERBURR

R24: The Fotona large spot size bleaching handpiece. A sturdy, user-friendly handpiece with larger spot sizes for fast and efficient teeth whitening procedures.

R21: The Fotona Nd:YAG handpiece.A nimble, lightweight and ergonomically detailed hand- piece for delicate softtissue procedures.

Fiber tips: Wide selection of fiber tips optimally designed for specifictreatments.

R02: The Fotona non-contact Er:YAG handpiece. This handpiece enables you to work in an ergonomic, comfortable non-contact position not achievablewith classical dentalinstruments.

R14: The Fotona contact Er:YAG handpiece with integrated spray nozzle. Interchange-able fiber tips allow you to optimize contact optical drilling. The integrated spray nozzles make this handpiece the ideal instrument for procedures that require simultaneous coolingand moisturizing of thetarget tissue.

LASERBURR

R24: The Fotona large spot size bleaching handpiece. A sturdy, user-friendly handpiece with larger spot sizes for fast and efficient teeth whitening procedures.

R21: The Fotona Nd:YAG handpiece.A nimble, lightweight and ergonomically detailed hand- piece for delicate softtissue procedures.

R21: The Fotona Nd:YAG handpiece. A nimble, lightweight and ergonomically detailed hand- piece for delicate soft tissueprocedures.

R02: The Fotona non-contact Er:YAG handpiece. This handpiece enables you to work in an ergonomic, comfortable non-contact position not achievablewith classical dentalinstruments.

R14: The Fotona contact Er:YAG handpiece with integrated spray nozzle. Interchange-able fiber tips allow you to optimize contact optical drilling. The integrated spray nozzles make this handpiece the ideal instrument for procedures that require simultaneous coolingand moisturizing of thetarget tissue.

LASERBURR

R24: The Fotona large spot size bleaching handpiece. A sturdy, user-friendly handpiece with larger spot sizes for fast and efficient teeth whitening procedures.

R21: The Fotona Nd:YAG handpiece.A nimble, lightweight and ergonomically detailed hand- piece for delicate softtissue procedures.

R24: The Fotona large spot size bleaching hand-piece. A sturdy, user-friendly handpiece with larg-er spot sizes for fast and efficient teethwhitening procedures.

R02–C: The Fotona non-contact Er:YAG handpiece with integrated spray nozzle. This handpiece enables you to work in an ergonomic, comfortable non-contact position not achievable with classical dental instruments.

R14: The Fotona contact Er:YAG handpiece with integrated spray nozzle. Interchangeable fiber tips allow you to optimize contact optical drilling. The integrated spray nozzles make this handpiece the ideal instrument for procedures that require simultaneous coolingand moisturizing of thetarget tissue.

Page 8: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

FIDELIS APPLICATIONS6

INCREASE YOUR TREATMENT

SUCCESS RATE

ENDODONTICS

VSP-shaped Nd:YAG – Optimal Root Canal Disinfection The strong absorption of high peak power Fidelis Nd:YAG laser energy in bacteria and its deep penetration into the deepest dentinal tubuli, make this laser the ideal tool in endodontics. Fidelis Nd:YAG laser-assisted endodontics improve your therapy success rate even in cases of chronically or grossly inflamed lesions.

Disinfecting Deeper Than Any Other ModalityDue to their surface tension properties, conventionally-used chemicals cannot eliminate bacteria in dentinal tubuli deeper than 100 µm. Unaffected by surface tension, the Fidelis Nd:YAG laser disinfects up to 1000 µm inside the tubuli; much deeper than any other classical method.

High Peak Power for Effective DisinfectionEffective laser endodontics requires that all bacteria are rapidly, thermally destroyed before the generated heat can diffuse into the surrounding dental tissue. This can only be achieved by means of providing high peak powers in short VSP-shaped Nd:YAG pulses. The Fidelis’ Nd:YAG laser can reach peak powers of up to 1.000 times higher compared to other light-based solutions.

PERIODONTICS

Improved Attachment of FibroblastsAn important effect of the Fidelis Nd:YAG and Er:YAG laser treatments is the modification of the root surface morphology and consequent improved attachment of fibroblasts to the treated root surface, which significantly improves treatment success rates and shortens recovery times. While the Fidelis Nd:YAG bactericidal effect is well-known in periodontics and endodontics, also the Fidelis Er:YAG laser provides simultaneous disinfection as it ablates diseased sulcular epithelium in micron-thin layers.

VSP-shaped Er:YAG for Scaling and Precise Root PlaningThe Fidelis Er:YAG laser is perfectly suited to effectively remove the most resistant concrements in even the most delicate and hard-to-reach places. In contrast to conventional scaling procedures, absolutely no force is necessary to clean the tooth surface, making the procedure extremely fast and efficient.

VSP-shaped Nd:YAG for a Strong Bactericidal EffectTypical applications for the high-precision Fidelis Nd:YAG laser in periodontics include gingivectomy, gingivoplasty, soft tissue crown lengthening and minor soft tissue recontouring. Treatment success is further improved since the Fidelis Nd:YAG laser ensures that even the most resistant bacteria are destroyed by its high peak power laser pulses.

Page 9: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

FIDELIS APPLICATIONS

A COMPLETESPECTRUM

OF SURGICALPROCEDURES

7

SURGERY

Unmatched Advantages in a Complete Range of Surgical ProceduresLaser surgery has many advantages over conventional methods. The bloodless operating field provides an excellent view during the whole procedure ultimately shortening operating time. The shorter exposure time of open wounds reduces the risk of infection. Simultaneous disinfection of the tissue further decreases the risk of infection. Your patient will hardly feel any discomfort or will not feel any discomfort at all; the reduced need for local anesthesia shortens the overall procedure time and eliminates unwanted side-effects. Additionally, the elimination of the need for suturing with laser surgery increases your patient’s comfort to an even larger extent. And lastly, laser surgery provides faster wound healing with less post-operative discomfort and swelling.

VSP-shaped Nd:YAG for Smoother Soft Tissue SurgeryThe homogeneous absorption of Fidelis Nd:YAG laser light in soft tissue results in precise tissue vaporization with simultaneous sterilization and coagulation. For greater patient comfort and procedure speed, Fidelis laser systems provide the possibility for water-cooling. Fidelis Nd:YAG laser surgical applications include frenectomy, gingivectomy, fibroma removal, hemangioma removal, removal of peri-implant gingival overgrowth, and many other challenging procedures.

VSP-shaped Er:YAG for Effortless, Precise Bone and Soft Tissue SurgeryThe strong absorption characteristics of Fidelis Er:YAG laser light make it the ideal tool for bone surgery. Its ablative characteristics allow effortless micron layer-by-layer removal for the most delicate surgical procedures. In soft tissue surgery, the Fidelis Er:YAG laser is indicated for delicate procedures where a controlled coagulation effect or no coagulation is required. Its haemostatic capacity is small due to its excellent absorption in water and consequent minimal thermal effect in the surrounding tissues. In cases where haemostasis is required, longer VSP-shaped pulse modes can be used to increase the thermal effect. The Fidelis Er:YAG laser is a very versatile and efficient instrument for complex procedures that require precision and versatility. Fidelis Er:YAG laser surgical applications include leukoplakia removal, lichen planus removal, gingivoplasty, bone surgery, elimination of diseased sulcular epithelium, frenectomy and fibroma removal and many other challenging procedures.

Fidelis Plus III: Power and versatility in one system.

Page 10: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

FIDELIS APPLICATIONS8

AESTHETICS

Fidelis IIId Aesthetics Upgrade PackagesIn today’s competitive health industry it makes sense to widen your horizons and develop strong healthcare partnerships through shared services. The Fidelis III aesthetics upgrade packages give you the unique opportunity to provide your patients aesthetic procedures ranging from laser-assisted tooth whitening, laser hair removal, acne treatments and facial rejuvenation treatments to facial vascular lesion treatments.

Facial Rejuvenation Treatment UpgradeBy creating a deep thermal effect without affecting upper skin layers the Fidelis Nd:YAG is the ideal tool to improve skin tone, texture and tightness. In addition, the Fidelis Er:YAG is widely accepted as the optimal tool for micron layer-by-layer ablation of the epidermis to stimulate regeneration of skin cells in sun-damaged skin and to improve the appearance of deeper wrinkles.

Facial Hair Removal Treatment UpgradeThe absorption by the skin of the Fidelis Nd:YAG laser energy, regardless of skin type, ensures penetration to the deepest hair follicles, without affecting surrounding skin structures. In aesthetic medicine Nd:YAG lasers are regarded as the golden standard in hair removal because of their superior safety, efficacy and efficiency.

Facial Vascular Lesion Treatment UpgradeFacial spider veins, telangiecasiae, hemangiomae are common aesthetic problems for many patients. The homogeneous penetration of Fidelis Nd:YAG laser energy deep into the skin thermally effects the entire volume of large and small blood vessels, thereby providing complete occlusion of the vessels and thus removing the vascular lesions.

R04: This Er:YAG dermatological handpiece provides 3 mm, 5 mm and 7 mm spotsizes. It is designed for skin resurfacing as well as for the removal of skin lesions and scars.

R30: This Nd:YAG aesthetics handpiece has a variable spotsize from a 2 - 8 mm and is recommended for the treatment of vascular and pigmented lesions, skin rejuvenation treatments as well as for permanent hair reduction.

R11: This Er:YAG dermatological handpiece comes with a 2 - 7 mm variable zoom focus. It is particularly recommended for skin resurfacing and the removal of skin lesions.

Page 11: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

ISO 9001:2000 - Development, production and sales of optical communication, opto- electronic and laser devices, the certification body of TÜV management service GmbH.

EN ISO 13485:2003 - Design and development, production and sales of medical surgical lasers, the certification body of TÜV product service GmbH.

EC-Certificate - Product category: Surgical lasers, MDD 93/42/EEC, Annex II.3, the certification body of TÜV product service GmbH.

ISO 13485:2003 - Design and development, manufacturing and sales of medical surgical lasers, according to CMDCAS. The certification body of TÜV AMERICA INC.

GMP - Quality system according to the US FDA regulation, CFR Title 21, Part 820.

Page 12: Fotona General Dentistry Brochure€¦ · infrared lasers, the Er:YAG laser has the highest absorption in hard dental tissue, allowing cold optical drilling in enamel, dentin and

ISO 9001:2000 - Development, production and sales of optical communication, opto- electronic and laser devices, the certification body of TÜV management service GmbH.

EN ISO 13485:2003 - Design and development, production and sales of medical surgical lasers, the certification body of TÜV product service GmbH.

EC-Certificate - Product category: Surgical lasers, MDD 93/42/EEC, Annex II.3, the certification body of TÜV product service GmbH.

ISO 13485:2003 - Design and development, manufacturing and sales of medical surgical lasers, according to CMDCAS. The certification body of TÜV AMERICA INC.

GMP - Quality system according to the US FDA regulation, CFR Title 21, Part 820.

FOTONA d.d.Stegne 71210 LjubljanaSLOVENIAPhone: ++ 386 1 500 91 00Fax: ++ 386 1 500 92 [email protected]