Page 1: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

FortasTM CV-30000 SpecificationsTypeApplicationVacuum Pump type Vacuum setting Flow rate

Ultrasound Transducer Frequency Pulse modeDiathermy Frequency OutputVitreous cutter Cutting system Cutting rate

External driven sourceIntraocular illumination Light source OutputAir pressure of FGXDriving pressure of viscosity fluid infusionIntraocular scissors Cutting rate Driving pressureHID illumination unit (optional) Light source OutputPower supply

Power consumptionDimensions / Mass

APCataract / Vitreoretinal surgery

Peristaltic pump0 to 700 mmHg0 to 60 mL / min (cataract surgery mode)0 to 200 mL / min (vitreoretinal surgery mode)

Piezoelectric40 kHz1 to 100 pulses / s

515 kHz0.5 to 10 W (5 to 100%)

Pneumatic driven guillotine system100 to 2500 cuts / min (with built-in air compressor)100 to 3000 cuts / min (with gas as an external drive source)Air or nitrogen gas, 550 to 750 kPa

Halogen lamp (12 V / 50 W)2 ports10 to 100 mmHg

100 to 300 kPa

50 to 400 cuts / min140 to 250 kPa

Xenon lamp (75 W)1 lamp / 2 portsAC 100, 115, 230 V ±10%50 / 60 Hz650 VA512 (W) x 555 (D) x 1540 (H) mm115 kg

ACataract surgery

Not available

Not available

Not available

Not available

Not available

450 VA

110 kg

The 510(k) is not cleared for distribution in the United States.

Specifications and design are subject to change without notice.

HEAD OFFICE34-14 Maehama, HiroishiGamagori, Aichi, 443-0038, JapanTelephone : +81-533-67-6611Facsimile : +81-533-67-6610URL : http://www.nidek.co.jp

[Manufacturer ]

TOKYO OFFICE(International Div.)3F Sumitomo Fudosan Hongo Bldg., 3-22-5 Hongo, Bunkyo-ku, Tokyo, 113-0033, JapanTelephone : +81-3-5844-2641Facsimile : +81-3-5844-2642URL : http://www.nidek.com

NIDEK INC.47651 Westinghouse DriveFremont, CA 94539, U.S.A.Telephone : +1-510-226-5700 : +1-800-223-9044 (US only)Facsimile : +1-510-226-5750URL : http://usa.nidek.com

NIDEK TECHNOLOGIES SrlVia dell'Artigianato, 6 / A35020 Albignasego (Padova), ItalyTelephone : +39 049 8629200 / 8626399Facsimile : +39 049 8626824URL : http://www.nidektechnologies.it

NIDEK S.A.Europarc13, rue Auguste Perret94042 Creteil, FranceTelephone : +33-1-49 80 97 97Facsimile : +33-1-49 80 32 08URL : http://www.nidek.fr

CNIDEK 2010 Printed in Japan CV-30000 OIDIMK1

Type AP Type A

Page 2: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Phaco Innovation

Cut Control

User Friendly

Essential Components

60

50

40

30

20

10

0

-10

-20

Time (s)

Property of surge *

An

teri

or

cham

ber

pre

ssu

re (

mm

Hg

)

CV-30000

CV-24000

Comparison of vacuum rise / drop at 600 mmHg *

Time (s)

Vac

uu

m (

mm

Hg

)

0      1     2     3     4     5

700

600

500

400

300

200

100

0

-100

* Data on file

CV-30000 phaco cassetteCV-30000 vit cassetteVenturi

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

Comparison of vacuum rise time at each vacuum set value *

100 200 300 400 500 600

Vac

uu

m r

ise

tim

e (s

)

Vacuum set value (mmHg)

CV-30000 phaco cassetteCV-30000 vit cassetteVenturi

Essential Components

Fortas Pump

ETS (Exquisite Tubing System)

New peristaltic pump

The refined pump achieves vacuum rise at shorter times than the venturi pump with use of a CV-30000 phaco cassette and provides secure nucleus retentivity of a phaco tip and enhanced followability.It achieves vacuum rise at similar times as the venturi pump with use of a CV-30000 vit cassette and provides quick vacuum response during vitreoretinal surgery.

Phaco cassette

The new evolved tubing system enhances the efficiency of aspiration and reduces the risk of surge.

Vit cassette

The new vent system controls the vacuum pressure effectively with reduction of the residual suction.

* Data on file

* Data on file

Page 3: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Phaco Innovation

Cut Control

User Friendly

Essential Components

60

50

40

30

20

10

0

-10

-20

Time (s)

Property of surge *

An

teri

or

cham

ber

pre

ssu

re (

mm

Hg

)

CV-30000

CV-24000

Comparison of vacuum rise / drop at 600 mmHg *

Time (s)

Vac

uu

m (

mm

Hg

)

0      1     2     3     4     5

700

600

500

400

300

200

100

0

-100

* Data on file

CV-30000 phaco cassetteCV-30000 vit cassetteVenturi

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

Comparison of vacuum rise time at each vacuum set value *

100 200 300 400 500 600

Vac

uu

m r

ise

tim

e (s

)

Vacuum set value (mmHg)

CV-30000 phaco cassetteCV-30000 vit cassetteVenturi

Essential Components

Fortas Pump

ETS (Exquisite Tubing System)

New peristaltic pump

The refined pump achieves vacuum rise at shorter times than the venturi pump with use of a CV-30000 phaco cassette and provides secure nucleus retentivity of a phaco tip and enhanced followability.It achieves vacuum rise at similar times as the venturi pump with use of a CV-30000 vit cassette and provides quick vacuum response during vitreoretinal surgery.

Phaco cassette

The new evolved tubing system enhances the efficiency of aspiration and reduces the risk of surge.

Vit cassette

The new vent system controls the vacuum pressure effectively with reduction of the residual suction.

* Data on file

* Data on file

Page 4: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Pow

er le

vel

Vac

uu

m le

vel

Low-duty pulse Low-duty pulse

Occlusion break point

Low-duty pulse High-duty pulse Ultrasound stopswhen a rapidsurge occurs.

Pump stop(Vacuum stop)

Basic vacuum Vacuum rise Basic vacuumTime (s)

Time (s)

3000

60

50

40

30

20

10

0

20002500

15001000

5000

100

300

500

700

50 to 6040 to 5030 to 4020 to 3010 to 200 to 10Flow rate (mL / min)

Vitreous cutter (20 G) aspiration flow rate

Flo

w r

ate

(mL

/ min

)Vacuum (mmHg)

Cutting rate (cpm)

Conventionalultrasoundoscillation

Position 1 Position 2 Position 3

Vacuum level

VISultrasoundoscillation

Position 1 Position 2 Position 3

Vacuum level

Cut Control

High Speed Vitreous Cutter

Maximum 3000 cuts / min

The excision per single cut is decreased with a high speed cutter and it is effective for precise treatment proximal to the retina.

Pro-Pedal Mode

Desired setting with smart software

Cutting rate, flow rate, and vacuum can be independently controlled and modified in three dimensions. This software improves performance during vitreoretinal surgery and efficiency of vitreous body excisions.

Phaco Innovation

VIS (Variable Intervals and Strokes)

Dual-oscillation of conventional pulse and ultra-short duration pulse

The nucleus can be emulsified easily with less energy by using dual-pulse oscillation.

The dual-pulse oscillation provides overlapping and separation of conventional pulse and ultra-short duration pulse. The ultra-short duration pulse can provide high energy or low energy for an extremely short duration. VIS provides numerous customizable oscillation settings.

Oscillation signal of conventional pulse Oscillation signal of ultra-short duration pulse Dual-oscillation image

APS-Plus (Auto Pulse System-Plus)

Efficient control of ultrasound and aspiration pump

Both ultrasound and aspiration pump automatically stop immediately after occlusion breaks to minimize surge. When the phaco tip is occluded, an automatic increase in the pulse duty provides a highly efficient control for phacoemulsification. The change in IOP can be controlled when the occlusion breaks.

Page 5: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Pow

er le

vel

Vac

uu

m le

vel

Low-duty pulse Low-duty pulse

Occlusion break point

Low-duty pulse High-duty pulse Ultrasound stopswhen a rapidsurge occurs.

Pump stop(Vacuum stop)

Basic vacuum Vacuum rise Basic vacuumTime (s)

Time (s)

3000

60

50

40

30

20

10

0

20002500

15001000

5000

100

300

500

700

50 to 6040 to 5030 to 4020 to 3010 to 200 to 10Flow rate (mL / min)

Vitreous cutter (20 G) aspiration flow rate

Flo

w r

ate

(mL

/ min

)

Vacuum (mmHg)

Cutting rate (cpm)

Conventionalultrasoundoscillation

Position 1 Position 2 Position 3

Vacuum level

VISultrasoundoscillation

Position 1 Position 2 Position 3

Vacuum level

Cut Control

High Speed Vitreous Cutter

Maximum 3000 cuts / min

The excision per single cut is decreased with a high speed cutter and it is effective for precise treatment proximal to the retina.

Pro-Pedal Mode

Desired setting with smart software

Cutting rate, flow rate, and vacuum can be independently controlled and modified in three dimensions. This software improves performance during vitreoretinal surgery and efficiency of vitreous body excisions.

Phaco Innovation

VIS (Variable Intervals and Strokes)

Dual-oscillation of conventional pulse and ultra-short duration pulse

The nucleus can be emulsified easily with less energy by using dual-pulse oscillation.

The dual-pulse oscillation provides overlapping and separation of conventional pulse and ultra-short duration pulse. The ultra-short duration pulse can provide high energy or low energy for an extremely short duration. VIS provides numerous customizable oscillation settings.

Oscillation signal of conventional pulse Oscillation signal of ultra-short duration pulse Dual-oscillation image

APS-Plus (Auto Pulse System-Plus)

Efficient control of ultrasound and aspiration pump

Both ultrasound and aspiration pump automatically stop immediately after occlusion breaks to minimize surge. When the phaco tip is occluded, an automatic increase in the pulse duty provides a highly efficient control for phacoemulsification. The change in IOP can be controlled when the occlusion breaks.

Page 6: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Optimal Cassette System

Separate cassette system for optimal vacuum control

With the use of the separate cassette system for cataract and vitreoretinal surgery, the CV-30000 provides optimal intraoperative vacuum control during the surgery.

Phaco cassette Vit cassette

Variety of Accessories

Disposable phaco tip Selectable vitreous cutter

The CV-30000 comes with a cost effective disposable phaco tip to maintain sterile conditions intraoperatively.

The selectable vitreous cutter based on the surgical techniques optimizes the effectiveness of vitreoretinal surgery.

20G vitreous cutter

23G vitreous cutter

25G vitreous cutter

Example of the program for combined cataract and vitreoretinal surgery

Multi-functional Foot Pedal

Enhanced operability with customized foot pedal functions

Integration with Green Laser

Efficient operation flow and space-saving

Navigation Mode

Guidance with pictures for the setup procedure

Navigation screen uses images to aid in the setup procedure for ease of use.

Sequential Mode

Programming for surgical procedure

Operation modes can be switched using the foot pedal.

Foot pedal functions are customizable with up to 8 selectable positions.

The CV-30000 is equipped with a room to integrate the NIDEK Green Laser GYC-1000. It enables efficient operation flow and effective use space in the operating room.

User Friendly

Page 7: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

Optimal Cassette System

Separate cassette system for optimal vacuum control

With the use of the separate cassette system for cataract and vitreoretinal surgery, the CV-30000 provides optimal intraoperative vacuum control during the surgery.

Phaco cassette Vit cassette

Variety of Accessories

Disposable phaco tip Selectable vitreous cutter

The CV-30000 comes with a cost effective disposable phaco tip to maintain sterile conditions intraoperatively.

The selectable vitreous cutter based on the surgical techniques optimizes the effectiveness of vitreoretinal surgery.

20G vitreous cutter

23G vitreous cutter

25G vitreous cutter

Example of the program for combined cataract and vitreoretinal surgery

Multi-functional Foot Pedal

Enhanced operability with customized foot pedal functions

Integration with Green Laser

Efficient operation flow and space-saving

Navigation Mode

Guidance with pictures for the setup procedure

Navigation screen uses images to aid in the setup procedure for ease of use.

Sequential Mode

Programming for surgical procedure

Operation modes can be switched using the foot pedal.

Foot pedal functions are customizable with up to 8 selectable positions.

The CV-30000 is equipped with a room to integrate the NIDEK Green Laser GYC-1000. It enables efficient operation flow and effective use space in the operating room.

User Friendly

Page 8: FortasTM CV-30000 Specificationscirmedica.com/wp-content/uploads/2016/01/CV-30000.pdfFortasTM CV-30000 Specifications Type Application Vacuum Pump type Vacuum setting Flow rate Ultrasound

FortasTM CV-30000 SpecificationsTypeApplicationVacuum Pump type Vacuum setting Flow rate

Ultrasound Transducer Frequency Pulse modeDiathermy Frequency OutputVitreous cutter Cutting system Cutting rate

External driven sourceIntraocular illumination Light source OutputAir pressure of FGXDriving pressure of viscosity fluid infusionIntraocular scissors Cutting rate Driving pressureHID illumination unit (optional) Light source OutputPower supply

Power consumptionDimensions / Mass

APCataract / Vitreoretinal surgery

Peristaltic pump0 to 700 mmHg0 to 60 mL / min (cataract surgery mode)0 to 200 mL / min (vitreoretinal surgery mode)

Piezoelectric40 kHz1 to 100 pulses / s

515 kHz0.5 to 10 W (5 to 100%)

Pneumatic driven guillotine system100 to 2500 cuts / min (with built-in air compressor)100 to 3000 cuts / min (with gas as an external drive source)Air or nitrogen gas, 550 to 750 kPa

Halogen lamp (12 V / 50 W)2 ports10 to 100 mmHg

100 to 300 kPa

50 to 400 cuts / min140 to 250 kPa

Xenon lamp (75 W)1 lamp / 2 portsAC 100, 115, 230 V ±10%50 / 60 Hz650 VA512 (W) x 555 (D) x 1540 (H) mm115 kg

ACataract surgery

Not available

Not available

Not available

Not available

Not available

450 VA

110 kg

The 510(k) is not cleared for distribution in the United States.

Specifications and design are subject to change without notice.

HEAD OFFICE34-14 Maehama, HiroishiGamagori, Aichi, 443-0038, JapanTelephone : +81-533-67-6611Facsimile : +81-533-67-6610URL : http://www.nidek.co.jp

[Manufacturer ]

TOKYO OFFICE(International Div.)3F Sumitomo Fudosan Hongo Bldg., 3-22-5 Hongo, Bunkyo-ku, Tokyo, 113-0033, JapanTelephone : +81-3-5844-2641Facsimile : +81-3-5844-2642URL : http://www.nidek.com

NIDEK INC.47651 Westinghouse DriveFremont, CA 94539, U.S.A.Telephone : +1-510-226-5700 : +1-800-223-9044 (US only)Facsimile : +1-510-226-5750URL : http://usa.nidek.com

NIDEK TECHNOLOGIES SrlVia dell'Artigianato, 6 / A35020 Albignasego (Padova), ItalyTelephone : +39 049 8629200 / 8626399Facsimile : +39 049 8626824URL : http://www.nidektechnologies.it

NIDEK S.A.Europarc13, rue Auguste Perret94042 Creteil, FranceTelephone : +33-1-49 80 97 97Facsimile : +33-1-49 80 32 08URL : http://www.nidek.fr

CNIDEK 2010 Printed in Japan CV-30000 OIDIMK1

Type AP Type A