form-finding design - university of warwick · form) form-finding design: shape of the arch is not...

28
Form-finding design Prof. Wanda J. Lewis School of Engineering, University of Warwick, UK Warwick Research Seminar, 27th April 2018 1

Upload: others

Post on 13-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Form-finding design

Prof. Wanda J. LewisSchool of Engineering, University of Warwick, UK

Warwick Research Seminar, 27th April 2018 1

Page 2: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Overview

• Introduction to form-finding

• Form-finding designs of fabric and shell structures

• Analytical form-finding: moment-less arch structures

- results and observations

• Case study: Gateway Arch in St. Louis

• Conclusions

2

Page 3: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

What is form-finding ?

It encompasses methods of shaping

structures by means of forces applied to

them

• Many methods are possible, using both physical

and computational modelling

• Form-found structures exhibit maximum

strength/mass ratio, as observed in natural

objects (plants, shells, trees).

3

Page 4: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Background: Tension fabric structures

The shape of a fabric membrane under

tension cannot be imposed; it has to be found

Form-finding

‘Form follows force’ principle:

Set of forces Structural form Structural response

4

Page 5: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Experimental form-finding methods

Inverted hanging models

(made of fabric or chains) Inflatable membrane

modelsSoap film models

Fabric and ‘free form’

roof structures

Shell structures Pneumatic membrane

roofs and domes5

Page 6: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

A soap film surface is a minimum

energy form or ‘minimal surface’. Such

surfaces are ideal tension structures

characterised by:

• constant (uniform) surface tension

• minimum surface area

• zero mean curvature (saddle shape)

Features of soap film (minimal) surfaces

It is advantageous to exploit the concept of

a ‘minimal surface’ in form-finding design of

tension fabric structures. 6

Page 7: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

250 Convertible Umbrellas in Madinah

Saudi Arabia

Design: SL-Rasch, 2011 7

PROJECT DATA:

Umbrella span: 26m x 26 m

Total area: 150,000 m2

Cost: $1.3 billion

Soap film model

- used interactively with

computational form-finding

Page 8: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Minimal surfaces in computational form-finding of

tension structures

(i) Initial ‘guessed’ surface is spanned between

chosen boundaries and constant surface

pre-stress is prescribed

(ii) The initial geometry and prescribed pre-

stress give rise to the out-of-balance forces

in the surface and lack of static equilibrium.

This requires incremental adjustments of

surface geometry to restore equilibrium

(iii) Iterative adjustments/calculations continue

until static equilibrium is reached.

Form-found

‘minimal’ surface8

Page 9: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Inverted hanging model in the design of shell structuresHeinz Isler (Switzerland)

Shell roof for Bürgi Garden Centre

Camorino, Switzerland,1973

Shell thickness: 90 mm

Span: 27m

Petrol station in Deitingen

Switzerland,1968

Shell thickness: 80 mm

Span: 30 m) 9

Page 10: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Inverted hanging model in the design of shell structuresAntonio Gaudi (Barcelona)

A series of chains

loaded with small

bags of sand gives

a set of spires, or

‘pointed’ catenaries

The model (left) is

photographed and

inverted to get the

final form

Güel Colony Church

- designed by this

method, but project not

completed

Sagrada Familia,

Ongoing project

since 1883

10

Page 11: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Inverted hanging model in computational form-finding of

shell structures

The model is represented by line or

surface elements. Gravitational loads

are applied to each node of the surface

In the final, inverted form,

tension is converted to pure

compression - a desired

action for a shell(or an arch

structure).

The surface is put into pure tension; its

geometry is then adjusted iteratively during

computations, until full equilibrium is reached

11

Page 12: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Conventional design: Shape of the arch is known

(circular, parabolic, or catenary

form)

Form-finding design:Shape of the arch is not known;

x, z co-ordinates are derived as

functions of span to rise ratio,

and values of q and w.

Moment-less arches develop pure compression, no bending

moments under statistically prevalent load

New approach: analytical form-finding

of moment-less arch forms

z deck weight, w

arch

weight, q

x

rise

span

Span = 50 m

w = 50 kN/m

q = 25 kN/m

12

Form-finding data:

Cross-section:

b = 1.47 m

d = 0.68 m

b

d

Page 13: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Motivation: failure of Gerrards Cross tunnel,UK, 2005

THE FACTS:

• 30 m section of a 320 m tunnel collapsed

• Structure analysed as an arch of 10 m span

and 300 mm thickness

• Failure after heavy rain

• Backfilling deviated from the ‘assumed’

construction sequence.

13

Page 14: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Observed mode of

failure corresponded to

that of a circular arch

However, the solution

did not involve re-

shaping of the arch,

but rebuilding it using a

deeper cross-section.

Displacement modes

under permanent loads

Circular

Parabolic

Catenary

14

Page 15: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Moment-less arches of constant cross-section

Catenary (inverted chain curve)

- moment-less when the only, or

dominant, load acting on the structure

is the arch weight. Gateway Arch in St.

Louis approaches a catenary form

Parabolic- moment-less when the only,

or dominant, load acting on the structure

is the deck weight; this is the most

common arch form in use

General case of a moment-less arch under both arch and deck weight has

been recently solved using an analytical form-finding model1.

1Lewis, W. J. 2016. Mathematical Model of a Moment-less Arch. Proc.Roy. Soc. A 15

Page 16: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Results: (a), (b), (c) - arches carrying the same deck load

(d) - centre line profiles

Req’d to match

max. stresses

in the moment-

less arch

Req’d to match

max. stresses

in the parabolic

arch

Moment-less

depth: d

Parabolic

depth: 1.5d

(b)(a)

Circular

depth: 2.6d

(c)

0

5

10

15

0 5 10 15 20 25 30 35 40 45 50

(d)moment-less

- - - parabolic

Max. z = 75 mm

Span to rise 4:1

16

z [

m]

b=1.47m

d=0.68m

x [m]

Page 17: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Material volumes required to match max. compressive stress in

the moment-less arch

17

0

25

50

75

100

125

150

175

200

2 4

Volu

me [

m3]

Span to rise ratio

Parabolic

Moment-less

0

250

500

750

1000

1250

2 4

Vo

lum

e [m

3]

Span to rise ratio

Circular

Parabolic

Moment-less

Circular Parabolic Moment-less

Span to rise m3 m3 m3

2 : 1 1,304 185 74

4 : 1 406 86 57

Page 18: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Results and observations

Amongst the dictated forms, a circular arch

(although aesthetically pleasing), is the most

inefficient structure

At span to rise of 4:1, there are very small

differences in the overall geometry of parabolic and

moment-less arches. Yet, the difference of just 75

mm requires 50% more material in the parabolic

arch to match the max. compressive stress of the

moment-less arch

Moment-less arch is the most efficient structure,

over a range of span to rise ratios used in practice.

.Deformed masonry arch.

Customs House, Exeter, 1681

Stone arch bridge at Dentdale

18

Page 19: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Gateway Arch in St. Louis - a moment-less arch form?

Originally designed as a catenary form, the

arch is not moment-less under its own

weight, because

• The cross- section area of the arch is not

constant

• Having experimented with form-finding,

the architect adjusted the intended arch

shape ‘by eye’. Surprisingly, this gave it

a shape mathematically defined 2 as

‘flattened catenary’.

2R. Osserman, (2010), How the Arch got its Shape. Nexus Network Journal 12, 167-189

y = -127.7 cosh (x/127.7)+ 757.7

19

Page 20: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

‘Flattened catenary’ shape required foundations to be moved closer together.

Constant stress moment-less arch (of varying cross section), shaped through

analytical form-finding, lies above the two catenary forms (research in progress). 20

0

45

90

135

180

225

270

315

360

405

450

495

540

585

630

-315 -225 -135 -45 45 135 225 315

x [ft]

Constantstress

Catenary

Flattenedcatenary-as built

Page 21: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Thank youQuestions?

I wish to thank the following contributors for the provision of their images: IL/ILEK,

Heinz Isler, NCE, Bill Harvey, ICE Publishing,

David Goodyear, and Warren Knoles.

Munich Olympic

Roof, 1972

Zhaozhou bridge

China, 605

21

O2 Arena, 2000

Hoover Dam

bridge, 2011

O2 Arena, 2000

Page 22: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Structure: teflon-coated glass-fibre membrane, forced into a synclastic

(dome) shape using pre-stressed and stay cables supported by masts. A

total of 700 kms of cable used.

The O2 Arena, 2000

Architecture: Richard Rogers

Design: Buro Happold

22

Page 23: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

23

Hoover Dam bridge: a moment-less arch form Design: TY Lin International, 2011

DESIGN DATA:

• R.C segmental rib arch, 268 m

above the Colorado river

• Span: 323 m (span to depth

ratio: 75)

• Rise: 84 m (initial span to rise

ratio: 3.8; achieved ratio: 3.7)

• Deck weight: 295 kN/m

• Arch weight: 410 kN/m

• Concrete strength: 70 MPa

• Material volume: 6,300 m3

Page 24: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Cable-stayed construction of 53 reinforced concrete segments. The

technique allowed to control bending moments during the erection process. 24

Page 25: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Arch shape adjusted during

construction to meet the

requirement of zero bending

moments under permanent

load; involved increasing

camber in the final stage

Final arch shape: a

moment-less arch . Arch

configuration deviating from

a parabolic shape by less

than 0.6 m (not noticeable by

eye).

25

Page 26: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

Munich Olympic Stadium Roof, 1972

Design: Frei Otto and Gunther Behnisch

A minimal ‘saddle-shape’ roof based

on soap films and fabric models

Structure: acrylic cladding resting on

pre-stressed cable supported by

masts. A total of 200 kms of cable

was used

Due to physical modelling

inaccuracies, the project marked a

start of computational form-finding.

Aerial view

Inside view

26

Page 27: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

27

Zhaozhou bridge, China, 605

BASIC DATA2:

• Span (central arch): 37 m

• Rise (central arch): 7.23 m;

span to rise ratio 5:1

• Foundations only 1.5 m deep

2 Man Zhou et.al. (2018). Spanning over 1400 years: China’s remarkable ZhaoZhou

bridge. ICE Proceedings, Civil Engineering 170, CE3, 113-119

Page 28: Form-finding design - University of Warwick · form) Form-finding design: Shape of the arch is not known; x, z co-ordinates are derived as functions of span to rise ratio, and values

28

Latest 2D analysis indicates

that the central arch shape

was based on a thrust line to

ensure the arch works in pure

compression under permanent

load

The arch curve was shaped by

the varied load applied from

above

This is perhaps the the oldest

example of a form-found

bridge.