Grado system

FORM 02.13.05.uk Grado system - verifies

Verifies

Page 2: FORM 02.13.05.Uk Grado System - Verifies

2

Description

Page 3: FORM 02.13.05.Uk Grado System - Verifies

1 4

3 2

Electric Cabinet

Mixer Motor

Batch Scale

Mixer Chamber

Views3

Page 4: FORM 02.13.05.Uk Grado System - Verifies

4

Drain Spout

Dispense Valves

Solenoides

Views

Page 5: FORM 02.13.05.Uk Grado System - Verifies

5Gain in weight system

time

SP#4SP#3SP#2SP#1

Weight

Weight and evaluation of dispense time for next cycle

Dispence

Waiting signal from mixer

Discharge

Mixer

Dispence Valves

Batch

Self compensatic control

Page 6: FORM 02.13.05.Uk Grado System - Verifies

6

Maintenance

Page 7: FORM 02.13.05.Uk Grado System - Verifies

Working Pressure 4,5 – 5,5 bar

on Grado sizesS - J - Q

Working Pressure 4 - 5 bar

Working Pressure 2,5 - 3 bar

GradoK - A

7

Mechanical Verifies

Page 8: FORM 02.13.05.Uk Grado System - Verifies

8

Batch Scale Load Cells

Mixer Chamber Load Cell

Load Cells

Page 9: FORM 02.13.05.Uk Grado System - Verifies

9

Do not press or push on the Mixer

Motor

Mixer Motor is fixed on the chamber and it’s

fixed on the Load Cell

Mixer: Mechanical Verifies

Page 10: FORM 02.13.05.Uk Grado System - Verifies

10

NO tubes or cables on the Mixer Motor

Mixer: Mechanical Verifies

Page 11: FORM 02.13.05.Uk Grado System - Verifies

11

No contact between Mixer Chamber and black cover

Mixer: Mechanical Verifies

Page 12: FORM 02.13.05.Uk Grado System - Verifies

12

No contact between Mixer Chamber and the structure

Mixer: Mechanical Verifies

Page 13: FORM 02.13.05.Uk Grado System - Verifies

13

No contact between Mixer Chamber and the structure

Mixer: Mechanical Verifies

Page 14: FORM 02.13.05.Uk Grado System - Verifies

14

Mixer Motor Rotation

Page 15: FORM 02.13.05.Uk Grado System - Verifies

15

Positioning of the Batch Scale on the guides

Page 16: FORM 02.13.05.Uk Grado System - Verifies

16

The pipes must create a bend

Piping compressed air lenght

Page 17: FORM 02.13.05.Uk Grado System - Verifies

Clean the areas from pellets

17

Maintenance

Page 18: FORM 02.13.05.Uk Grado System - Verifies

18

The flap must close hermetic

Pressure Regulators

Maintenance

Page 19: FORM 02.13.05.Uk Grado System - Verifies

19

Batch Scale

Dosing Slide Gate 4

Dosing Slide Gate 2

Dosing Slide Gate 3

Dosing Slide Gate 1

132 4

Solenoides

Page 20: FORM 02.13.05.Uk Grado System - Verifies

20

Slide Gates

Page 21: FORM 02.13.05.Uk Grado System - Verifies

a) Remove the 2 bolts

b) Pull down the slide gate kit

21

Mechanical Verifies

Page 22: FORM 02.13.05.Uk Grado System - Verifies

22

Mechanical Verifies

Page 23: FORM 02.13.05.Uk Grado System - Verifies

23

Correct position of

the clip

Thinner Spacer

Larger Spacer

Mechanical assembly

Page 24: FORM 02.13.05.Uk Grado System - Verifies

24

Verify the consuption

Mechanical verifies

Page 25: FORM 02.13.05.Uk Grado System - Verifies

25

Parameters

Page 26: FORM 02.13.05.Uk Grado System - Verifies

26

• Batch weight• Max batch weight

Mixer min level

Mixer level to call loadingMixer working time

F#i Stop cycle if mat. is missing

Parameters

Page 27: FORM 02.13.05.Uk Grado System - Verifies

27

Alarms

Page 28: FORM 02.13.05.Uk Grado System - Verifies

MIN level Feeder #

Component # missingInconstant Flow Feeder #

Dosing # NOT OKOUT of tollerance Feeder #

Mixer protection Opened

Batch Balance FullBatch Balance NOT unloaded

Balance Opened, Dosing impossibleBalance Closed, Mixer missing load

Mixer missing Load

28

Alarms

Page 29: FORM 02.13.05.Uk Grado System - Verifies

29

Feeder # STOP with dosing SP% > 0Feeder #1 with met. valve OPEN/CLOSE

Mixer hopper MIN level

Weight Cell (Balance) not tuned

Weight Cell (Mixer) not tuned

Mixer Thermal Trip

Alarms

Page 30: FORM 02.13.05.Uk Grado System - Verifies

30

Various

Page 31: FORM 02.13.05.Uk Grado System - Verifies

31

132 4

% dosing range for each feeder Serial Number

Labels

Page 32: FORM 02.13.05.Uk Grado System - Verifies

32

Remove the Batch Scale

Transport precautions

Page 33: FORM 02.13.05.Uk Grado System - Verifies

33This document and the information therein are the exclusive property of Doteco SPA. Characteristics and data are not binding and are subject to change without notice.

Put the Mixer transport protection

Transport precautions