forensic labdock s5 and u5 - cru...6 protecting your digital assets tm forensic labdock s5 and u5...
TRANSCRIPT
Protecting Your Digital AssetsTM
Wiebetech Branding
2c85m76yPMS 711C
66c7m7yPMS 299C
Product Name:Univers 73 Black Extended
abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ
Forensic Labdock™ S5 and U5User ManualFeatures
• Easyattachmentandwrite-blockedaccessto2.5”and3.5”IDE/PATAandSATAharddrives.
• Write-blockedaccesstoUSBthumbdrives(U5modelonly).
• AccessSASdrivesviaaRedPort™SASwrite-blockedPCIehostbusadapter(S5modelonly).
• Convenientstoragecubbykeepsyourdrivesoutofthewayduringimaging.Aquietfankeepsthecubbycool.
• Recognizesandreportsthepresenceofahiddenarea(HPAorDCO)ontheharddrive.IncludedsoftwareutilitycanbeusedtoconfiguretheForensicLabDocktohandlethesehiddenareasinthewayyouprefer.
• EightlabeledLEDindicatorsreportreal-timeoperationalstatus.
2
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
1 PRE-INSTALLATION STEPS
1.1 PACKAGE CONTENTSThefollowinglistcontainstheitemsthatareincludedinthe
completeconfigurationforthisdevice.PleasecontactCRUif
anyitemsaremissingordamaged:
Accessories U5 Model
S5 Model
ForensicLabDock 1 1
4-pinLegacyMolexpowercable 1 1
IDEcablefor3.5”drives(40-pinto40-pin) 1 1
SATAdata/powerconnector 1 1
USBA-typetoB-typecablewithbracket 1 0
USBB-typeto10-pinheadercable 1 0
Packetofscrews 1 1
QuickStartGuide 1 1
1.2 IDENTIFYING PARTSTakeamomenttofamiliarizeyourselfwiththepartsofthe
ForensicLabDock.Thiswillhelpyoutobetterunderstandthe
followinginstructions.
TABLE OF CONTENTS1Pre-InstallationSteps 2
1.1PackageContents 2
1.2IdentifyingParts 2
1.3LEDBehavior 3
1.4WarningsandNotices 3
2InstallationSteps 4
2.1ConfigureHPA/DCOMode 4
2.2InstalltheForensicLabDockIntoYourComputer 4
2.3ConnectingHardDrivestotheForensicLabDock 5
2.3.1SATAHardDrives 5
2.3.2IDE(PATA)HardDrives 5
2.3.3SASHardDrives(AvailableonlyonS5models) 6
2.3.4USBThumbDrives(AvailableonlyonU5models) 6
2.3.5USBDriveEnclosures(AvailableonlyonU5models) 6
2.3.6OtherTypesofDrives 6
3HotswappingwithMacandWindowsOperatingSystems 7
3.1MacOSX 7
3.2WindowsOperatingSystems 7
4UpdatingFirmware 8
5ForensicSoftwareUtility 8
6FAQ 8
7TechnicalSpecifications 9
Write-BlockedIDEConnector
DriveActivityLED
PowerLED
FRONT OF THE S5 MODEL
Write-BlockedeSATAConnector
SASPass-throughConnector
IDE/SATAWrite-BlockStatusLED
HardDriveCubby
PowerSwitch
Molexpowerconnector
HPA/DCOIndicator
FanFailIndicator
PowerFailIndicator
ErrorIndicator
3
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
1.3 LED BEHAVIOR
LED COLOR STATE DESCRIPTION
Power Green Solid TheForensicLabDockispoweredon.
DriveActivity Amber SolidorBlinking
Theattacheddriveisbeingaccessed.
ErrorIndicator Red Solid
Theattacheddrivehasreached131°F/55°C,oranHPA/DCO-relateddiskcommandhasfailed.
PowerFailIndicator Red Solid
Thereisaproblemwitheitherthe+5Vor+12Vpoweroutputtotheattacheddrive.
HPA/DCOIndicator Amber Solid
AnHPAorDCOareahasbeendetected.Oncelit,itwillnotbeunlituntiltheLab-Dock’spoweriscycled.
FanFailIndicator Red Solid
Thecoolingfanhasstoppedworkingandneedsreplaced.PleasecontactCRUTechnicalSupport.
USBWrite-BlockStatus Amber Solid TheattachedUSBde-
viceiswrite-blocked.*
IDE/SATAWrite-BlockStatus
Amber SolidTheattachedIDEorSATAdriveiswrite-blocked.
*ThisLEDappearsonlyontheForensicLabDockU5.
1.4 WARNINGS AND NOTICESPleasereadthefollowingbeforebeginninginstallation.
General Care
• ThemaincircuitboardoftheForensicLabDockissus-
ceptibletostaticelectricity.Propergroundingisstrongly
recommendedtopreventelectricaldamagetotheenclo-
sureorotherconnecteddevices,includingthecomputer
host.Avoidalldramaticmovement,tappingontheunit,
andvibration.
• Avoidplacingtheharddrivesclosetomagneticdevices,
highvoltagedevices,ornearaheatsource.Thisincludes
anyplacewheretheproductwillbesubjecttodirect
sunlight.DoNOTallowwatertomakecontactwiththe
driveortheForensicLabDock.
PowerConnector
REAR OF THE S5 FLDs MODEL
SATADataConnectorForFrontSATA/IDE
Connections
SATA&PATAFirmware
ConfigurationPort
SASPass-throughDataConnectortoRedPortHBACard
PowerConnector
REAR OF THE U5 MODEL
SATADataConnectorForFrontSATA/IDE
Connections
SATA&PATAFirmware
ConfigurationPort
Write-BlockedUSBPass-throughConnector
Write-BlockedIDEConnector
DriveActivityLED
PowerLED
FRONT OF THE U5 MODEL
Write-BlockedeSATAConnector
Write-BlockedUSBConnector
IDE/SATAWrite-BlockStatusLED
HardDriveCubby
PowerSwitch
Molexpowerconnector
HPA/DCOIndicator
FanFailIndicator
PowerFailIndicator
USBRemountButton
USBWrite-BlockStatusLED
ErrorIndicator
4
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
• Beforestartinganytypeofhardwareinstallation,pleaseensurethatallpowerswitcheshavebeen
turnedoffandallpowercordshavebeendisconnectedtopreventpersonalinjuryanddamagetothe
hardware.
2 INSTALLATION STEPS
TheForensicLabDockrequiresaSATAdataconnectioninsideyourcomputer.TheU5modelalsorequiresaUSBdataconnectionforthewrite-blockedUSBport,andtheS5modelrequiresaSASconnectiontoaRedPortSASwrite-blockedPCIehostbusadapter(HBA).Ifyoudonotalreadyhavethenecessaryconnectorsinsideofyourcomputer,youmustaddanHBAcardwiththeappropriateconnectorsintoanemptyexpansionslotinsideyourcomputer.
2.1 CONFIGURE HPA/DCO MODETheForensicLabDockgivesyoutheabilitytoselectthewayhiddenareasonharddrives(HPAsandDCOs)
arehandled.TheForensicLabDockwillonlynotifyyoubydefaultofthepresenceofthesehiddenareasby
blinkingtheHPA/DCOLEDindicator.Othermodesallowyoutoviewtheinformationinthesehiddenareas.
Tochangemodes,followthestepsbelow.Ifthedefaultbehaviorissatisfactory,continuetoSection2.2.
a. ConnectaUSBcablefromyourcomputertothe“SATA&PATAFirmwareConfigonly”USBporton
therearoftheForensicLabDock.YoumayfindthiseasiesttodobeforeinstallingtheForensicLabDock
insideacomputer.
b. ConnectaSATApowercablefromthecomputer’spowersupplytotherearoftheForensicLabDock.
c. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
d. DownloadandinstalltheForensicSoftwareUtility—afreesoftwareapplicationdesignedforusewith
theForensicLabDock:www.cru-inc.com/support/software-downloads/forensic-software-utility/
e. OpentheForensicSoftwareUtilityandnavigatetotheHPA/DCOBehaviortab.
f. Selectthedesiredbehavior(leavetheminplace,removeHPAtemporarilybutignoreDCO,removeHPA
permanentlybutignoreDCO,orpermanentlyremovethemboth).
g. ClicktheSetHPA/DCOBehaviorbutton.
h. TurntheForensicLabDockoffandunplugitfromtheUSBandSATApowercables.
2.2 INSTALL THE FORENSIC LABDOCK INTO YOUR COMPUTERa. MounttheForensicLabDockintoanempty5.25”drivebayinsideofyourcomputer.Donotscrewit
intoplaceuntilallthecableshavebeenconnected.
b. ConnectaSATApowercablefromthecomputer’spowersupplytotherearoftheForensicLabDock.
c. AttachtheSATAdatacablefromyourcomputersystemtotherearoftheForensicLabDock.
d. Connecttheremainingopendataport(USBontheU5modelandSATAontheS5model)ontherearof
theForensicLabDocktoyourcomputersystem.ThereareseparatewaystoconnectforbothSATAand
USBdevices,whicharedetailedonthenextpage.
BothmodelscontainaUSBportthatisusedforfirmwareconfigurationonly.UsetheUSBportonthefarrightthatislabeled“ConnectUSBForFrontPanelUSBWriteBlocker”instead.
STOP!
STOP!
5
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
ForUSB,therearethreewaystoconnect:
• Ifyourmotherboardhasanavailable10-pinUSBheader,usethe“USBB-typeto10-pinheader”
cable.
• UseaUSBB-typetoB-typecabletoconnecttoaUSBhostcard.
• UseaUSBB-TypetoA-typecableandattachtheA-typeendtoanavailableUSBportonyourcom-
puter.
ForSATA:
• ConnectaSATAdatacabletotherearoftheForensicLabDockandtheotherendtoanavailable
portonyourwrite-blockedRedPortSASHBAcard.
Connectingthepass-throughporttoanyhostotherthanaRedPortcardwillresultinthecorre-spondingfrontpanelportbecomingread/writeratherthanwrite-blocked.
e. UsetheprovidedscrewstosecuretheForensicLabDockintothe5.25”drivebay.
Usingscrewsotherthantheprovidedmountingscrewsmayputpressureonthedrivecubby,makingitdifficulttoinsertandremovedrivesfromit.Alwaysusetheprovidedmountingscrewswherepos-sible.
YourForensicLabDockisnowreadytouse!
2.3 CONNECTING HARD DRIVES TO THE FORENSIC LABDOCK
2.3.1 SATA Hard Drivesa. Inserttheharddriveintothecubby.Facethepoweranddataconnectionsideoutward.
b. AttachtheincludedSATAdata/powerconnectortotherearofthedrive.
c. Connectthe4-pinpowercableontheSATAdata/powerconnectortothepowerportonthefrontof
theForensicLabDock.
d. ConnecttheeSATAdatacableoftheSATAdata/powerconnectortothewrite-blockedeSATAport
nexttothepowerswitchonthefrontoftheForensicLabDock.
e. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
2.3.2 IDE (PATA) Hard Drivesa. Inserttheharddriveintothecubby.Facethepoweranddataconnectionsideoutward.
b. Attachtheincludedappropriately-sizedIDEcableandtheincluded40-pinlegacyMolexpowercable
toyourharddrive.Bothconnectorsarekeyedtofitonlyoneway.
c. RemoveanyeSATAconnectorfromtheeSATAportnexttothepowerswitchonthefrontofthe
ForensicLabDock.IDE/PATAdrivescannotberecognizedifaSATAconnectionisdetected.
d. ConnecttheotherendsoftheIDEcableandthe40-pinlegacyMolexpowercabletotheappropriate
write-blockedportsonthefrontoftheForensicLabDock.
e. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
NOTE
STOP!
6
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
2.3.3 SAS Hard Drives (Available only on S5 models)a. Inserttheharddriveintothecubby.Facethepoweranddataconnectionsideoutward.
b. AttachtheincludedSATAdata/powerconnectortotherearofthedrive.
c. Connectthe4-pinpowercableontheSATAdata/powerconnectortothepowerportonthefrontof
theForensicLabDock.
d. ConnecttheeSATAdatacableoftheSATAdata/powerconnectortothe“SASPassThru”port
abovethe4-pinlegacyMolexpowerportonthefrontoftheForensicLabDock.
e. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
2.3.4 USB Thumb Drives (Available only on U5 models)a. Plugthedeviceintothe“USBWriteBlocker”portonthefrontoftheForensicLabDock.
b. IfthedevicehasanOn/Offswitch,turniton.
c. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
Ifthecomputerfailstorecognizethethumbdrive,cyclethethumbdrive’spower(butremovingandreinsertingitorswitchingitoffandonagain)andthenpresstheRemountbutton.
2.3.5 USB Drive Enclosures (Available only on U5 models)ThisfeatureisusefulforpreviewingthecontentsofaUSBdriveenclosuretodetermineifitcontains
digitalevidencethatyouneedtoacquire.Ifitdoes,youcanthendecidewhethertoacquiretheevi-
dencethroughtheUSBconnectionortoopenthedriveenclosureandattachthebareharddrivetothe
ForensicLabDockwithanIDEorSATAwrite-blockedconnection.
SupportedUSBdriveenclosureshavethefollowingcharacteristics:
• Areseenasasinglephysicaldevicebyyourcomputer’sOS
• ArepoweredbyanACadapteroranextraUSBbuspowercable
ConnectthedriveenclosuretotheForensicLabDock’s“USBWriteBlocker”portwithaUSBcableand
powertheenclosureon.ThenflipthepowerswitchontheForensicLabDocktothe1positiontopower
theForensicLabDockon.
2.3.6 Other Types of DrivesCompatibleSATAandPATAdriveadaptersareavailablethatallowtheForensicLabDocktoaccessto
2.5”PATA/IDE,Hitachi1.8-inch,Toshiba1.8-inch,MacBookAir2010,mSATA,PCIePATA,PCIeSATA,
orPCIeUSBdrives.
a. Connectthedrivetotheadapter.
b. Attachtheincluded4-pinlegacyMolexpowercabletotheadapterandtheotherendtothefrontof
theForensicLabDock.
c. ConnecttheappropriateSATAorIDEcabletothedriveadapterandtheotherendtotheForensic
LabDock.
d. Flipthepowerswitchtothe1positiontopowertheForensicLabDockon.
NOTE
7
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
3 HOTSWAPPING WITH MAC AND WINDOWS OPERATING SYSTEMS
3.1 MAC OS XUnmountthevolumebeforepoweringdowntheForensicLabDockbydraggingthevolume’sicontothe
Trash,orbyselectingthevolumethenpressingCommand-E.Oncethevolumehasdisappeared,turnthe
ForensicLabDockoff.IfyouareusingaSASorSATAdevice,CRUrecommendsusingaSASorSATAhost
busadapter(HBA)cardthatsupportshotswapping.Otherwise,MacOSXwillnotsupporthotswapping
withSATAdevices.
IfyouareconnectingaUSBdevicetotheForensicLabDock,swapoutthenewdrive,turntheForensic
LabDockon,andMacOSXwillautomaticallydetectthenewdrive.
3.2 WINDOWS OPERATING SYSTEMS
3.2.1 Hotswapping a SAS or SATA DeviceCRUrecommendsusingaSASorSATAhostbusadapter(HBA)cardthatsupportshotswappinginorder
toeasilyejectandremountdrives.
Ifyouhaveahostbusadapter(HBA)cardthatsupportshotswappinginstalled,unmountthevolume
beforepoweringitdownbyleft-clickingontheUSB plug iconwiththegreencheckmarkonthe
Desktoptaskbarandthenselectingtheproperdevicefromthemenuthatpopsup.Youmayhaveto
clickontheShow Hidden Icons arrowonthetaskbartofindthecorrecticon.Windowswillindicate
whenitissafetoturntheForensicLabDockoff.ReconnectanewdrivetotheForensicLabDock,turnit
on,andyoursystemwillautomaticallydetectthenewdrive.
IfyoudonothaveanHBAinstalled,followthesesteps:
a. FortheWindows8productfamily,pressWINKEY + X,thenselectDevice Managerfromthemenu
thatpopsup.
ForWindows7,Vista,andtheWindowsServer2008and2012productfamilies,right-clickonthe
Computer buttonintheStartMenuandselectManage.IntheleftpaneoftheComputerManage-
mentwindowthatopens,left-clickonDevice Manager.
b. ExpandtheDisk drives section.
c. PowerofftheForensicLabDockbyturningthepowerswitchtothe0position.
d. InDeviceManager,clicktheScan for hardware changes buttoninthetoolbar.Notethatthe
targetdrivehasdisappearedfromthelistofdrives.
e. ConnectanewdrivetotheForensicLabDockS5.
f. TurnthepowerswitchontheForensicLabDockS5tothe1positiontoturntheuniton.
g. InDeviceManager,clicktheScan for hardware changes buttoninthetoolbaragain.Thenew
volumewillnowappear.
3.2.2 Hotswapping a USB DeviceUnmountthevolumebeforepoweringitdownbyleft-clickingontheUSB plug iconwiththegreen
checkmarkontheDesktoptaskbarandthenselectingtheproperdevicefromthemenuthatpops
up.YoumayhavetoclickontheShow Hidden Icons arrowonthetaskbartofindthecorrecticon.
8
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
WindowswillindicatewhenitissafetoturntheForensicLabDockoff.Reconnectanewdrivetothe
ForensicLabDock,turniton,andyoursystemwillautomaticallydetectthenewdrive.
4 UPDATING FIRMWARECRUprovidesfreefirmwareupdatesfortheForensicLabDockthroughourConfiguratorapplication.
Downloadithere:www.cru-inc.com/support/software-downloads/configurator-software-download/
Ifyourproductisrunningoutdatedfirmware,youwillseeapromptaskingyoutoupdateonceyoulaunchthe
Configuratorapplication.Followtheinstructionsontheprompttoupdatethefirmware.
5 FORENSIC SOFTWARE UTILITYTheForensicLabDockiscompatiblewithCRU’sForensicSoftwareUtilityapplication.Thissoftwareallowsyou
toperformawrite-blocktestonyourForensicLabDockandmodifyitsHPAandDCOhandlingbehavior.Italso
includestheabilitytodisplaydetailsaboutattachedwrite-blockersanddrivesandallowsyoutosavethatdata
toafileforeasyinclusioninacasereport.
Downloadithere:www.cru-inc.com/support/software-downloads/forensic-software-utility/
ForinformationonHPA/DCOhandling,seeSection2.1.
6 FAQ
6.1 WHAT IS AN HPA AND A DCO?AHostProtectedArea(HPA)andDeviceConfigurationOverlay(DCO)arereservedareasonaharddrive
thatarenotaccessiblebytheBIOSorOS.DatacanbehiddenbehindanHPAorDCO.CRUforensic
devicescanalertyouifthereisanHPAorDCOsothatyouareawareofitandcantakethenecessarysteps
toretrievethehiddendata.
6.2 WHY IS IT NECESSARY TO UPDATE THE FIRMWARE OF MY CRU FORENSIC DEVICE?Firmwarerelatestotheprogramsanddatathatcontrolelectronicproducts.Firmwareisenhancedover
time,usuallytoaddnewfeaturesorincreasecompatibility.Updatingfirmwarecanimprovethefunctionality
anddependabilityofyourproduct.IfyourCRUforensicdeviceisusingoutdatedfirmware,CRU’sConfigu-
ratorapplicationcanrecognizethisandimplementup-to-datefirmwareonyourdevice.SeeSection4ofthis
manualformoreinformation.
6.3 MY FORENSIC LABDOCK WORKS GREAT WITH SATA DRIVES BUT I AM HAVING COMPATIBILITY ISSUES WITH IDE/PATA DRIVES. WHAT SHOULD I DO?First,checktomakesuretheSATAdata/powerconnectorisunpluggedfromtheSATAoutputport.IDE/
PATAdrivescannotberecognizedifaSATAconnectionismadewiththeSATAoutput.Next,checkto
makesurethe4-pinlegacyMolexpowercableispluggedintotheIDE/PATAdrive.Ifthepowerandhost
connectionaresecurelyattachedtothedrive,thentheIDEcablemaybefaulty.ContactTechnicalSupport
forfurtherinstructions.
6.4 HOW SHOULD I SET MY IDE/PATA HARD DRIVE JUMPER SETTINGS?Trythe“Master”configurationonyourharddrivefirst.Someharddriveshavetwodifferent“Master”
settingsoneforwhenthereisasecondary“slave”drivepresentandoneforwhenthereisnoslavedrive
9
Protecting Your Digital AssetsTM
Forensic LabDock S5 and U5 User Manual
present.Choosethesettingwithnoslavepresent.Theremaybesomedrivesthatwillnotworkwitheither
ofthesesettings.Thenextchoiceis“CableSelect”.Ifthisdoesnotwork,tryusingnojumpers.Ifyou’re
unsurehowtochangethejumperconfiguration,checkthemanualthatcame:withyourharddriveorthe
manufacturer’swebsite.Somedrivesalsohavetheinformationprintedonthelabel.
6.5 CONTACTING TECHNICAL SUPPORTStillneedhelp?PleasecontactourTechnicalSupportteamthroughwww.cru-inc.com/support.Orcallustoll
freeat(800)260-9800ordirectlyat(360)816-1800.
7 TECHNICAL SPECIFICATIONSProductModels ForensicLabDockS5,ForensicLabDockU5
InterfaceTypes&Speeds
eSATA:upto6GbpsIDE/PATA:upto133MB/sUSB(U5Modelonly):upto480MbpsSAS(S5Modelonly):upto6Gbps
FrontDataConnectors
One(1)eSATAconnectorOne(1)IDE/PATAconnectorOne(1)USB/SAScomboconnector(onlyUSBisactiveontheU5model;onlySASisac-tiveontheS5model)
RearDataConnectors
One(1)write-blockedSATAconnectorOne(1)write-blockedUSBconnector(U5modelonly)One(1)SASconnector(S5modelonly)One(1)USBconnectorforfirmwareconfiguration
HPA/DCOHandling
Fourmodesofoperation(selectableusingtheForensicSoftwareUtilityapplication):1.LeaveHPAandDCOinplace2.RemoveHPAtemporarilybutignoreDCO3.RemoveHPApermanentlybutignoreDCO4.PermanentlyremoveHPAandDCO
SupportedOperatingSystems
Windows8.1,8,7,andVistaWindowsServer2012,2008,and2003productfamiliesMacOSX10.4.xornewerLinuxdistributionsthatsupporttheconnectiontypeused
ComplianceEMIStandard:FCCPart15ClassA,CEEMCStandard:EN55022,EN55024CE
ProductWeight 1.55lbs(0.703kg)
ProductDimensions 6.81inx5.79inx1.65in(173mmx147mmx42mm)
TechnicalSupportYourinvestmentinCRUproductsisbackedupbyourfreetechnicalsupportforthelife-timeoftheproduct.Contactusthroughourwebsite,www.cru-inc.com/supportorcallusat1-800-260-9800or+1-360-816-1800.
Protecting Your Digital AssetsTM For more information, visit the CRU web site.
www.cru-inc.com
©2015CRUAcquisitionGroup,LLC.ALLRIGHTSRESERVED.
ThisUserManualcontainsproprietarycontentofCRUAcquisitionGroup,LLC(“CRU”)whichisprotectedbycopyright,trademark,andotherintellectualpropertyrights.
UseofthisUserManualisgovernedbyalicensegrantedexclusivelybyCRU(the“License”).Thus,exceptasotherwiseexpresslypermittedbythatLicense,nopartofthisUserManualmaybereproduced(byphotocopyingorotherwise),transmitted,stored(inadatabase,retrievalsystem,orother-wise),orotherwiseusedthroughanymeanswithoutthepriorexpresswrittenpermissionofCRU.
UseofthefullForensicLabDockv5productissubjecttoallofthetermsandconditionsofthisUserManualandtheabovereferencedLicense.
CRU®,ForensicLabDock™,andRedPort™(collectively,the“Trademarks”)aretrademarksownedbyCRUandareprotectedundertrademarklaw.ThisUserManualdoesnotgrantanyuserofthisdocumentanyrighttouseanyoftheTrademarks.
Product WarrantyCRUwarrantsthisproducttobefreeofsignificantdefectsinmaterialandworkmanshipforaperiodoftwoyearsfromtheoriginaldateofpurchase.CRU’swarrantyisnontransferableandislimitedtotheoriginalpurchaser.
Limitation of LiabilityThewarrantiessetforthinthisagreementreplaceallotherwarranties.CRUexpresslydisclaimsallotherwarranties,includingbutnotlimitedto,theimpliedwarrantiesofmerchantabilityandfitnessforaparticularpurposeandnon-infringementofthird-partyrightswithrespecttothedocumentationandhardware.NoCRUdealer,agent,oremployeeisauthorizedtomakeanymodification,extension,oradditiontothiswarranty.InnoeventwillCRUoritssuppliersbeliableforanycostsofprocurementofsubstituteproductsorservices,lostprofits,lossofinformationordata,computermalfunction,oranyotherspecial,indirect,consequential,orincidentaldamagesarisinginanywayoutofthesaleof,useof,orinabilitytouseanyCRUproductorservice,evenifCRUhasbeenadvisedofthepossibilityofsuchdamages.InnocaseshallCRU’sliabilityexceedtheactualmoneypaidfortheproductsatissue.CRUreservestherighttomakemodificationsandadditionstothisproductwithoutnoticeortakingonadditionalliability.
FCC Compliance Statement: “ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredopera-tion.”
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceatthisownexpense.
IntheeventthatyouexperienceRadioFrequencyInterference,youshouldtakethefollowingstepstoresolvetheproblem:
1) Ensurethatthecaseofyourattacheddriveisgrounded.2) UseadatacablewithRFIreducingferritesoneachend.3) UseapowersupplywithanRFIreducingferriteapproximately5inchesfromtheDCplug.4) Reorientorrelocatethereceivingantenna.
PartNumber:A9-000-0047Rev1.1
FOROFFICEORCOMMERCIALUSE