for tomorrows' storm - border states
TRANSCRIPT
Prepared Today Tomorrow's Stormfor
YOUR SOLUTION FOR DISTRIBUTION LINE PRODUCTS
BORDER STATES
2
Stay Ahead of the Storm with Border States
2
Transformers ....................................3
Fuses ............................................3–4
Connector Splices ...........................5
Deadend Connectors ...................5–7
General Use Connectors .................7
Mechanical Connectors ..................8
Compression Connectors ...........8–9
Hot Line Clamps & Stirrups .............9
Pole Line Hardware.................... 9–12
Earth Tension Anchors ............ 12–13
Guying ...................................... 13–14
Grounding Equipment ...................14
Surge Arresters ..............................14
Type C Cutouts ...............................15
Deadend Crossarms ......................16
Crossarms & Braces ......................16
Overhead Cable .............................16
Armor Rods .................................... 17
Conductor Tie................................. 17
Insulators ........................................18
Load Handling Equipment ....... 18–19
Tools .........................................19–20
Meter Sockets & Accessories .......20
Service Entrance Fittings ..............20
Tape ..........................................20–21
Flashlights and Lamps ............ 21–22
Safety/Apparel .......................... 22–27
Cleanup ..........................................27
After-Hours Emergency HELP Line 800.800.0199
Essential products we stock for you
Distribution Products
©Copyright 2009 Hubbell Power Systems
3
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Rating (A) Nominal Speed Ratio BSE Part #
12003 3 10 159985
Type 200 Trip-O-Link Fuse Link • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Type K Fit-All Cable Fuse Link • Universal adapter assembly will adapt Fit-All fuse links for use in the cutouts that have bolt-type cable connections to connect the upper as well as the lower cable • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Mfr. Model # Rating (A) Nominal Speed Ratio BSE Part #
32002CPS 2 7 160212
32015CPS 15 7 160309
32020 20 7 160171
32025CPS 25 7 160147
Type K Trip-O-Link Fuse Link • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Mfr. Model # Current Rating (A) Nominal Speed Ratio BSE Part #
31001 1 7 160164
31002CPS 2 7 159889
31003CPS 3 7 160032
31006 6 7 160033
31008 8 7 160035
31010 10 7 160036
31012 12 7 160315
31015 15 7 160037
31020CPS 20 7 160038
31025CPS 25 7 160039
31040CPS 40 7 160040
Fuses
/Kearney™
/Kearney™
/Kearney™
KVA Rating Primary Voltage Secondary Voltage Bushings BSE Part #
10 14400 120/240 1 2272868
15 7200 120/240 1 2272843
15 14400 277 1 2304136
15 14400 120/240 2 2304166
25 7200 277 2 2272863
50 7200 277 2 2272838
75 7200 120/240 2 2272869
Cooper Power, Single-Phase Overhead Conventional Distribution Transformer—Envirotemp® FR3• Envirotemp® FR3 fl uid • Interlaced windings on 0-75KVA • KVA mark 2-1/2" black decal centered below secondary bushings • Per REA specifi cations
KVA Rating Primary Voltage Secondary Voltage Bushings BSE Part #
5 7200 120/240 1 2272867
10 7200 120/240 1 2272839
15 7200 120/240 1 2272840
25 7200 120/240 1 2272851
37.5 7200 120/240 1 2272864
50 7200 120/240 1 2272831
75 7200 120/240 1 2272865
Cooper Power, Single-Phase Overhead Completely Self Protected (CSP) Distribution Transformer—Envirotemp® FR3• Envirotemp® FR3 fl uid • Has normal duty Ultrasil arresters (non gapped) • Interlaced windings on 0-75KVA • KVA mark 2-1/2" black decal centered below secondary bushings • Per REA specifi cations
Transformers
4
Stay Ahead of the Storm with Border States
Type X Fit-All Cable Fuse Link • Dual elements allow the fuse to respond as low temperature single element fuses for long time overloads, yet have superior lightning surge withstand capability • Universal adapter assembly will adapt fi t-all fuse links for use in the cutouts that have bolt-type cable connections to connect the upper as well as the lower cable • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Mfr. Model # Rating (A) Nominal Speed Ratio BSE Part #
42100CPS 1 32 160206
42150CPS 1 ½ 32 160130
42200CPS 2 32 160048
42350CPS 3 ½ 32 160225
Type X Trip-O-Link Fuse Link • Dual elements allow the fuse to respond as low temperature single element fuses for long time overloads, yet have superior lightning surge withstand capability • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Mfr. Model # Current Rating (A) Nominal Speed Ratio BSE Part #
41200 2 32 160047
41250 CPS 2.5 32 160162
41275CPS 2.75 32 160166
41350 3.5 32 160391
41400 4 32 160127
41550 5.5 32 160270
Mfr. Model # Current Rating (A) Nominal Speed Ratio BSE Part #
51003 3 12 160051
51006 6 12 160052
51008CPS 8 12 160053
51010CPS 10 12 160054
51012 12 12 160056
51015 15 12 159886
Type T Fit-All Cable Fuse Link • Dual elements allow the fuse to respond as low temperature single element fuses for long time overloads, yet have superior lightning surge withstand capability • Universal adapter assembly will adapt Fit-All fuse links for use in the cutouts that have bolt-type cable connections to connect the upper as well as the lower cable • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
/Kearney™
/Kearney™
/Kearney™
Mfr. Model # Rating (A) Nominal Speed Ratio BSE Part #
11007 7 10 160246
11010 10 10 159977
11025 25 10 159980
Type 200 Fit-All Cable Fuse Link • Universal adapter assembly will adapt Fit-All fuse links for use in the cutouts that have bolt-type cable connections to connect the upper as well as the lower cable • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
/Kearney™
Type KS Fit-All Cable Fuse Link• Kearney™ Type KS fuse links employ dual element construction which gives the Type KS high surge withstand capability • Universal adapter assembly will adapt Fit-All fuse links for use in the cutouts that have bolt-type cable connections to connect the upper as well as the lower cable • Meets the latest version of ANSI 37.42 and NEMA SG2.1 standards
Mfr. Model # Rating (A) Nominal Speed Ratio BSE Part #
21002CPS 2 20 160018
21003 3 20 160019
/Kearney™
Mfr. Model # Current Rating (A) Nominal Speed Ratio BSE Part #
M3TA23 3 12 100268
M6TA23 6 12 100269
M8TA23 8 12 100275
M10TA23 10 12 100277
M12TA23 12 12 100278
M15TA23 15 12 100281
M20TA23 20 12 100285
M25TA23 25 12 100286
M30TA23 30 12 100288
Type T Fuse Link• Fuse element: stainless-steel strain/pure tin fuse wire• Required cutout fuse holder: 100A (do not use in a 200A fuse holder)• For special loading situations, such as, short-time overloads and cold-load pick-up• Pigtail length: 23"• Removable button head
5
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Automatic Conductor SizeConductor Diameter BSE Part #
GL-111 #6 Solid, 3#12 Copperweld .16"–.17" 152916
GL-112 #4 Solid CU, #8A Copperweld .19"–.20" 152919
GL-113#3 Sol., #4 Str., 6A
Copperweld.22"–.23" 152922
Copper Automatic Splice• Splice material is copper and the gripper material is bronze alloy• Inhibitor is loaded
Mfr. Model # Color CodeAutomatic
Conductor SizeConductor Diameter BSE Part #
GL-402A Orange4 ACSR, 4 AAAC,
4 AAC.225"–.250" 153267
GL-404 Red 2 AWG .280"–.320" 152925
GL-4042A Red4 - 2 ACSR, 4 - 2 AAAC, 4 - 2 AAC
.220"–.320" 152952
GL-406A Yellow1/0 ACSR, 1/0 AAAC, 1/0 AAC
.355"–.400" 153123
GL-407 Gray2/0 ACSR, 2/0 AAAC, 2/0 AAC
.400"–.470" 152927
GL-408 Black3/0 ACSR, 3/0 AAAC, 3/0 AAC
.450"–.530" 152928
GL-409A Pink4/0 ACSR, 4/0 AAAC, 4/0 AAC
.505"–.595" 153257
GL-409 Pink4/0 ACSR, 4/0 AAAC, 4/0 AAC
.505"–.595" 152929
GL-411 Green336.4 ACSR, 394.5 AAAC, 397.5 AAC
.659"–.724" 153340
Aluminum Automatic SpliceProvides permanent mechanical holding and electrical current transfer.• ANSI C119.4 full tension class A connector • Color coded funnel guide for easy identifi cation • Factory inhibitor protected • Shell material: high strength aluminum alloy • Jaw material: aluminum alloy
Connector Splices
Mfr. Model #
Assembly Rating
(Ultimate) Inhibitor LoadedConductor Diameter BSE Part #
GDW-20106,000 lbs. Clevis 4,000 lbs. Eye
Plated Jaws for Copper Conductor .230"–.448" 1071087
Aluminum Automatic Deadend Side Opening Wedge• For use with AAC, AAAC and ACSR• Adjustable• High strength aluminum alloy shell• Stainless steel cotter pin • Galvanized steel clevis
Mfr. Model # Color Code SizeConductor Diameter BSE Part #
GD-402A Orange4 (6/1) ACSR; 4AAAC, AAC .225"–.250" 153270
GD-406A Yellow1/0 ACSR, AAAC, AAC
.355"–.4" 153290
Aluminum Automatic Deadend Flex Bail Fastest method of deadending ACSR, AAAC and AAC conductor.• Aluminum alloy shell and inhibitor protected aluminum jaws assure corrosion resistance • Color coded funnel guide for easy identifi cation • Flared conductor funnel guides ease installation• Stainless steel
Deadend Connectors
Mfr. Model #Conductor Diameter
Conductor Size Copperweld (A)
Conductor Size Copper Solid (AWG) BSE Part #
GD-512 .190"–.200" 8 4 152992
GD-513 .220"–.230" 6 3 153107
Copper Automatic Deadend Clevis Bail Fastest method of deadending copper and Copperweld conductor.• Flared mouth of gripping unit permits easy conductor installation • Four-segment jaw is precision machined and automatically adjusts to the contour of the wire • High strength alloy copper tube for gripping Copperweld conductors
6
Stay Ahead of the Storm with Border States
Mfr. Model # Length Ultimate StrengthConductor Size ACSR (AWG) BSE Part #
DE-46-N 3 ⁷⁄₈" 8,000 lbs. 6–3/0 120816
PG-46-N 4 ¹⁄₁₆" 8,000 lbs. 6–3/0 120817
PG-57-N 5 ½" 10,000 lbs. 4–4/0 120822
Aluminum Strain Clamp Quadrant Body and keeper material is 356-T6 aluminum alloy and the hardware is constructed from galvanized steel.• RUS listed • Can be used on all aluminum conductors• Number of bolts: 2
Mfr. Model # Length
Nominal Conductor Size
Color Code
Conductor Diameter BSE Part #
SG-4502 13"#4, 6/1 #4, 7/1 ACSR & Comp.;#4, 7W All-Alum. & Alum. Alloy
Orange .225"–.257" 161127
SG-4504 15"
#2, 6/1 #2 7/1 ACSR;#2, 7W All-Alum. & Alum. Alloy; #2, 6/1
#1, 7W Comp.
Red .290"–.325" 161128
SG-4506 19"
1/0, 6/1 ACSR;1/0, 7W All-Alum. & Alum. Alloy; 1/0, 6/1
2/0, 7W Comp.
Yellow .361"–.400" 161130
Service-Grip DeadEnd Manufactured of aluminum-covered steel, is designed for bare neutral messengers of self-supporting cable used in making service drops.• For use on: ACSR, all-aluminum, aluminum alloy, compacted ACSR and compacted all-aluminum
Distribution-Grip Deadend Manufactured of aluminum-covered steel and designed for single-pole distribution construction. This item is recommended for direct application over plastic jacketed conductor. • Right-hand lay standard
Mfr. Model # Nominal Guy Wire Size Conductor Diameter BSE Part #
GDE-5102 ³⁄₈" 7-Strand .360"–.405" 1532716
Steel Automatic Deadend Designed for use on high strength, common, Siemens-Martin, utilities and bell system strand.• Aluminum alloy yoke• HS aluminum alloy shell and jaw material• Stainless steel bail• Bail option: standard
Mfr. Model # Strand Size Conductor Diameter BSE Part #
GLS-5002 ³⁄₈" .360"–.405" 1675303
GLS Automatic Splice For splicing applications with overhead or support guy wires, Fargo GLS-5000 series automatic splices are designed for use on high strength, common, Siemens-Martin, utilities and bell system strand.
Mfr. Model # Length
Nominal Conductor Size
Color Code
Conductor Diameter BSE Part #
DG-4541 17"#4, 7W All-Alum. & Alum. Alloy; #4, 6/1 Comp. ACSR
Orange .229"–.257" 161101
DG-4542 24"#2, 7W All-Alum. & Alum. Alloy; #2, 6/1 Comp. ACSR
Red .290" –.325" 161104
DG-4544 26"1/0, 7W All-Alum.
& Alum. Alloy; 1/0, 6/1 Comp. ACSR
Yellow .365" –.409" 161106
Utility Market Segments We Serve
Border States provides power utility products and technical support as well as materials for underground utilities, electrical substations, power generation, power distribution/transmission and power line construction.
7
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # LengthStrand
SizeColor Code
Mean Diameter
Strand Construction BSE Part #
GDE-1107 35" ³⁄₈" Orange.356", .360"
3W, 7W 161109
GDE-1108 38" ⁷⁄₁₆" Green 0.435" 7W 161112
Galvanized Steel GUY-GRIP™ Deadend Intended for use on single-wood poles associated with distribution construction. This style is used on extra high strength, high strength, Siemens-Martin and utilities grade.• Left-hand lay standard
Mfr. Model # Code Name Kcmil Diameter BSE Part #
OG-9360Swan
Swanate#4 6/1 #4 7/1
.250"
.257" 161075
O-Grip DeadEnd Intended to terminate aluminum based conductors in primary and neutral applications.• Designed to be installed directly to suspension insulators or eye type hardware without the need for additional components • Comes complete with helical deadend, clevis pin, washer and cotter pin• A non-metallic washer is provided to prevent electrical interference noise
Wedge Clamps• Designed for low tension applications only • Wedge clamps are available with a variety of bail lengths and styles as well as with irradiated fi nish for contaminated areas• Solid stainless steel: 6 ½" length
Mfr. Model # Conductor Range Conductor Diameter BSE Part #
7195 No. 2–6 AWG .160"–.330" 133625
7187 No. 4–1/0 AWG .250"–.414" 133622
7197 No. 2/0–4/0 AWG .414"–.563" 133628
Aluminum Wedge Clamps For deadending self-supporting drop wire.• Saves conductor—drop wire may be cut to length • Can be attached to bare neutral at any point in the span • Grips ACSR, AAAC, or aluminum conductor
Mfr. Model # Conductor Range BSE Part #
W20-1 2/0 Str.–2 Sol. 142655
W40-1 4/0 Str.–2/0 Sol. 142670
W62-1 1 Str.–6 Sol. 142643
Mfr. Model # Conductor Size BSE Part #
UCG25RS CU and AL (AWG) Min–Max: 8, 1 122326
Multiple Purpose Parallel Clamp Tapit™ clamp for all combinations of copper, aluminum, ACSR, 6201 and 5005.
General Use Connector
Steel Strandlink®
Steel Strandlink is used for splicing applications with overhead or down guy wire.• Recommended for use on common grade, Siemens-Martin, high strength utility grade, galvanized and aluminized steel strand • Recommended for use with Alumoweld, aluminized, EHS and galvanized steel• Rated to hold a minimum of 90% of RBS strand used
Mfr. Model #Primary Strand
Application Conductor Diameter BSE Part #
5002 ³⁄₈" .36"–.405" 133602
8
Stay Ahead of the Storm with Border States
Mfr. Model # LengthTap: Copper Cable Range
Run: Copper Cable Range BSE Part #
YC4C6 ⁵⁄₈" 6 Sol.–6 Str. 6 Sol.– 4 Str. 122348
YC4C4 ⁵⁄₈" 4 Sol.– 4 Str. 6 Sol.– 4 Str. 122346
YC2C4 ¾ " 8 Sol.– 4 Str. 2 Sol.– 2 Str. 122344
YC2C2 ¾ " 2 Sol.– 2 Str. 2 Sol.– 2 Str. 122343
Type YC-C Copper Crimpit™ C-shape compression connector for making tap or parallel copper connections from #12 solid to 4/0 stranded conductor.• Manufactured from high conductivity wrought copper • Range-taking connector • UL listed 90° C, 600 volts to 35kV
Compression Connectors
Mfr. Model # Run Conductor Diameter BSE Part #
ST-3 .125"–.440" 121188
Bronze Parallel Groove Connector Single-center bolt.• Stainless steel bolt• Bronze alloy body
Mfr. Model # LxWxH Tap: Copper Cable Range BSE Part #
LC-811-A-XB 1 ¼" x 2" x 2 ¼" 8 Sol.–1 /0 Str. 120966
Aluminum Parallel Groove ConnectorSingle-center bolt and a copper liner.• For aluminum to copper conductor connections only • Sealant (XB) is recommended on all connections • Tap has a metallurgically bonded copper liner• RUS listed • Alluminum alloy body• Bolt diameter: .38" Mfr. Model # Die Code Groove “A” Run Groove “B” Tap BSE Part #
YHO-1 O Sol. 6–1 Sol. 6–1 122541
YHO-2 O Sol. 1–2/0 Sol. 6–1/0 122542
YHD-3 D3 Sol. 3/0–4/0 Sol. 6–1/0 122544
YHD-4 D3 Sol. 2/0–4/0 Sol. 2/0–3/0 122548
YHD-5 D3 Sol. 250–300 Sol. 6–1/0 122545
YHD-6 D3 Sol. 250–300 Sol. 2/0–3/0 122552
Loktap™ Compression Connector High-quality, range-taking devices which accommodate combinations of aluminum to copper and aluminum to aluminum conductors.• “C” groove on both sides of the connector for use in street lighting applications
Mfr. Model # Bolt Head Type
Run: Conductor Diameter
Tap: Conductor Diameter BSE Part #
LC-52-C-XBHex with Square
Shank.289"–.741" .128"–.398" 120849
LC-83-A-XBRound with
Square Shank.727"–1.126" .128"–.447" 120948
Single-Center Bolt Aluminum Parallel Groove Connector For AL to AL and AL to CU splice/tap connections.• Aluminum alloy body with galvanized steel bolt• No plating• Inhibitor
Mechanical Connectors
Service Entrance Sleeve for Insulated Combinations of Copper, Aluminum and ACSR Compressed• Polyethylene caps prevent dirt from building up in barrel• Pre-fi lled with Penetrox™ joint compound • Color coded• RUS accepted
Mfr. Model #Side A
CU & ALSide B
CU & ALSide A ACSR
Side BACSR BSE Part #
ES4W4W 5, 6 Str.; 4 Sol.5, 6 Str.;
4 Sol6 AWG 6 AWG 122671
ES2W2W 3, 4 Str.; 2 Sol.3, 4 Str.;
2 Sol.4 AWG 4 AWG 122645
ES2R2R1 Str.; 2 Str.; 1
AL compt.; 2 AL compt.
3, 4 Str.; 2 Sol.
4 AWG 4 AWG 122599
ES25R25R 1/0 Str.; 1-19 Str. 1/0 Str. 1/0 AWG 1/0 AWG 122708
Electronic Data Interchange (EDI) DI)
We support various EDI transaction sets including purchase orders, order acknowledgements, advance ship notices and invoices to take transaction costs and errors out of the supply chain.
9
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Length Die Code BSE Part #
YCS25R 7 ¹⁄₈" 243 123843
YCS-R Jumper Sleeve Jumper sleeve for ACSR, all aluminum, 6201, 5005 and compressed. Hysplice™ sleeve designed to withstand jumper loop tensile and vibration stresses. Made of aluminum with staked-in cable stop.• Installed with same die as equivalent full-tension sleeves • Pre-fi lled with PENETROX™ joint compound• 1/0 AWG
Mfr. Model # Length
Die Code
Color Code Conductor
Rated Holding Strength BSE Part #
YSS6R 4.72" 162 Blue6 ACSR; 4 Sol. Al
900; 700 lbs. 423445
YSS4R 3.78" BG or ⁵⁄₈ Orange 4 ACSR1000; 800;
700 lbs. 122740
YSS2R 3.78" BG or ⁵⁄₈ Red2 ACSR; 2
Al (7)1600;
1200 lbs. 122735
Hysplice™ Single Aluminum Sleeve Designed for service drop or short span overhead distribution lines.• Color coded cap • Installed with OH25 one-hand tool and other standard tooling
• Pre-fi lled with PENETROX™ joint compound
Mfr. Model # Material
Run: Conductor Diameter
Tap: Conductor Diameter
RUS Listed BSE Part #
S1520AGPTin-Plated Aluminum
.128"–.414" .128"–.438" – 100416
S1530AGPTin-Plated Aluminum
.162"–.745" .162"–.547" – 100427
BC-2/0 Bronze .128"–.414" .128"–.414" Yes 120713
Overhead Primary Hot Line Tap Clamp For aluminum, ACSR and armor rod covered aluminum or ACSR conductor.• AAC, AAAC, ACSR, Range: 0.1428"–0.414"
Hot Line Clamps & Stirrups
Mfr. Model #
Side A ACSR
Side B ACSR
Side A CU and AL
Side B CU and AL BSE Part #
YSU2W6W 4 AWG – 3, 4 Str.; 2 Sol.6 Sol.;
8 Str.; #8 122668
YSU2R2W 2 AWG 4 AWG2 Str.; 1 Str.;
#1, #23, 4 Str.; 2 Sol. 122612
YSU2R2R 2 AWG 2 AWG2 Str.; 1 Str.;
1 AL compt; 2 AL compt
2 Str.; 1 Str.; 1 AL Compt; 2
AL Compt122605
YSU25R2W1 /0 AWG
4 AWG1/0 Str.; 2/0;
1/0 AWG3,4 Str.; 2 Sol. 122688
YSU25R2R1 /0 AWG
2 AWG1/0 Str.; 2/0;
1/0 AWG2 Str.; 1 Str.;
#1, #2 122687
YSU25R25R1 /0 AWG
1 /0 AWG
1/0 Str.; 2/0 AL Compt; 1/0
AL Compt
1/0 Str.; 2/0 AL Compt; 1/0 AL
Compt122691
Service Entrance Sleeve for Combination of Copper, Aluminum and ACSR Compressed• Heavy walled aluminum tubing with solid barrier minimizes galvanic corrosion of conductors• Pre-fi lled with Penetrox™ joint compound and strip-sealed • Color coded• RUS accepted
Mfr. Model # Maximum Connector Length BSE Part #
CCO 2 ½ " 122475
CCD 2 ¾ " 122471
Crimpit™ Cover Crimpit™ Cover For All O, D and N die tap connectors.• No extra hardware needed: slip cover over connector and snap shut
Bolted Offset Neutral Bracket• Galvanized steel• Arm length: 12 ¼"
Mfr. Model # Top Hole Size Rod Diameter BSE Part #
DC6N1 ¹¹⁄₁₆" x 1 ³⁄₈" ⁵⁄₈" 145985
Pole Line Hardware
Since 1912
DOWN. RIGHT. SOLID.
10
Stay Ahead of the Storm with Border States
Mfr. Model # Length
Mounting Hardware
Thread Diameter
Shank Diameter Standards BSE Part #
4717 14" 2 ¼" x ³⁄₁₆" 1 ³⁄₈" ⁵⁄₈" – 130366
881P 10 ¾" 2" x ¹⁄₈" 1" Nylon ¾" ANSI 100949
881AP 11 ½" 2" x ¹⁄₈" 1" Nylon ⁵⁄₈" ANSI 100982
Insulator Crossarm Pin Includes square washer, square nut and curved lock nut.• RUS listed• Hot-dip galvanized
Mfr. Model # Mounting Bolt BSE Part #
IB4 ⁵⁄₈" or ¾" 812010
Pole Top Insulator Bracket Mounts post or pin type insulator to top pole.• RUS listed• Hot-dip galvanized
Mfr. Model #
Mounting Holes
Mounting Bolt Spacing
Thread Diameter Standards
RUS Listed BSE Part #
2162 2 5" 1" ANSI Yes 130342
2174 3 5" & 8" 1" ANSI – 130344
2195 2 8" 1 ³⁄₈" – Yes 130345
2199P 2 8" 1" – Yes 961076
Pole Top Insulator Pin• Straight base design and two mounting holes• Pin is hot dip galvanized pressed steel.• “P” denotes nylon threading• Standard is lead
Line Post Stud For wood crossarms, made of galvanized steel.
Mfr. Model # Overall Length Thread Length Stud Diameter BSE Part #
DF19M2 7" 1 ¹⁄₈" ⁵⁄₈" 146511
Mast Type Porcelain Wireholder Clamp strap is slotted for installation without removing nut from bolt. • ANSI/NEMA standard • RUS listed
Mfr. Model # Material Pipe Size Range BSE Part #
C207-0075 Porcelain/Steel 1 ¼" – 2 ½" 100059Insulated Clevis
Mfr. Model # Width Depth Confi guration BSE Part #
C212-0142 31" 6 ½ " NEMA A, 12" Vertical Spacing 100064
Transformer Bracket, Wing-Rack Type• RUS listed • Tested to 2,000 lbs. per transformer position (simultaneous loading)• Galvanized steel, bolted
Mfr. Model # Mounting Hole Size Steel Size Standards BSE Part #
0327 ¹¹⁄₁₆ x ¾ Slot ³⁄₁₆" x 4" ANSI/NEMA 130328
0352 None ³⁄₁₆" x 1 ½" – 130332
Crossarm Saddle PinTwo ⁵⁄₈" x 7" carriage bolts, two square nuts, two curved lock nuts and a ⁵⁄₁₆" x 1 ½" washer plate are included. Hot dip galvanized fi nish. • RUS listed
Mfr. Model #
Diameter of Insulator Thread
Height Above Arm Thread Length BSE Part#
14322 1" Lead 5 ¾" 3" 130522
14322-1 1 ³⁄₈" Lead 6 ¾" 3" 130523
14322P 1" Nylon 5 ¾" 3" 2250295
14322-1P 1 ³⁄₈" Nylon 7" 3" 2250296
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
• Insulator not included • Insulator size NEMA 53-4• Galvanized steel
• RUS listed• Cotter bolt diameter: ⁵⁄₈"
11
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # BSE Part #
5801 130388
Anchor Shackle With ⁵⁄₈" diameter pin. Used primarily for attaching suspension insulators to the pole.
Mfr. Model #Length
Under Head Thread LengthActual Hole Diameter BSE Part #
8634-1/2 4 ½" 1 ¾" ³⁄₈" 130455
8635 5" 1 ¾" ³⁄₈" 574431
Carriage Bolt Square nuts, fi nished points and rolled threads. Standard heads have square shoulders.
Double-Arming Bolt Permits replacement ease in double arms. Cone type point for easy starting and driving-out without damage to threads. Each bolt provided with 4 square nuts.
Mfr. Model # Length Diameter BSE Part #
8862 12" ⁵⁄₈" 130480
8864 14" ⁵⁄₈" 130481
8866 16" ⁵⁄₈" 130482
8868 18" ⁵⁄₈" 130483
8870 20" ⁵⁄₈" 130484
8872 22" ⁵⁄₈" 130485
Mfr. Model # Length Thread Length Diameter Head Type BSE Part #
508754 4" 2 ⁵⁄₈" ½" ¾" Square 130558
Lag Screw Screw is made of steel and is hot-dip galvanized.
Mfr. Model # Length Diameter BSE Part #
8706 6" ½" 130462
8806 6" ⁵⁄₈" 130470
8808 8" ⁵⁄₈" 130471
8809 9" ⁵⁄₈" 130472
8810 10" ⁵⁄₈" 130473
8812 12" ⁵⁄₈" 130474
8814 14" ⁵⁄₈" 130475
Square Head Machine Bolt Made of steel with a galvanized fi nish. Square nut with square head included.• ANSI/NEMA and RUS listed
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
• Hot-dip galvanized steel• Diameter: ⁵⁄₈"
• ANSI/NEMA standard• RUS listed
• Drive type: fetter, regular point • RUS listed
• Hot-dip galvanized • RUS listed
• Drop-forged steel• Hot-dip galvanized
• RUS listed
Mfr. Model # Length Under Eye BSE Part #
29960 10" 130541
29962 12" 130542
29964 14" 130543
Oval Eye Bolt Constructed from steel with a galvanized fi nish.• Thread length: 6"• Diameter: ⁵⁄₈"• Size of eye: ⁹⁄₁₆" x 1 ½" x 2"• ANSI/NEMA and RUS listed
Mfr. Model # Width Bolt Trade Size Height BSE Part #
6502 2 ½" ⁵⁄₈" 3" 130403
Oval Eyenut Drop-forged, hot-dip galvanized steel.• ANSI/NEMA and RUS listed
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
BSE-Commerce
Our internet information service provides secure online access, to check pricing and product availability, view and print invoices and place orders 24/7. The enhanced product catalog provides detailed material information, product images, and search options.
12
Stay Ahead of the Storm with Border States
Mfr. Model # Length Total Unit Length Thread Length BSE Part #
7742 10" 14 ¾" 4" 130443
7743 12" 16 ¾" 6" 130444
Single-Upset Bolt Made of steel with a galvanized fi nish.• Furnished with 2 square nuts
MF Curved Lock Nut Nut is made of steel with a galvanized fi nish.• RUS listed
Mfr. Model # Bolt Trade Size BSE Part #
3511 ½" 130350
3512 ⁵⁄₈" 130351
3513 ¾" 130352
3514 ⁷⁄₈ 614379
Staple
Mfr. Model # Dimensions BSE Part #
C205-0247 1 ½" x ¼" x .148" 130060
9167 1 ½" x ³⁄₈" x .162" 130504
Mfr. Model # Length WidthRUS
ListedBolt
Trade Size HeightHole Dia. BSE Part #
6813 2 ¼" 2.3" No ⁵⁄₈" ³⁄₁₆" ¹¹⁄₁₆" 130426
6814 2 ¼" 2.3" Yes ¾" ³⁄₁₆" ¹³⁄₁₆" 130427
6817 3" 3" Yes ¾" ¼" ¹³⁄₁₆" 574396
Flat Square Washer Made of steel with a galvanized fi nish.• ANSI/NEMA standards
Mfr. Model #Length
& Width Bolt Trade Size Height Hole Dia. BSE Part #
6822-1/2 3" ¾" ¼" ¹³⁄₁₆" 130431
Curved Square Washer Made of steel with a galvanized fi nish.• ANSI/NEMA standards
Mfr. Model #Bolt
DiameterHole
Diameter Size BSE Part #
PS6803 ½" ⁹⁄₁₆" 1 ³⁄₈" O.D. x 12 Gauge 130421
½" Flat Round Washer
Spring Clip Lock washer Made from hot-dip galvanized steel.• RUS listed
Mfr. Model # Bolt Trade Size Height Hole Diameter BSE Part #
3540 ⁵⁄₈" 1 ¾" ¹¹⁄₁₆" 130357
Mfr. Model #Torque Rating
Single Helix Diameter
Rod Diameter
Installation Tool BSE Part #
C102-5205 8,000 lbs. 10" 1" C102-1583 130297
Tough One-Anchor Helix for PISA Anchor Rods Anchors have a painted coating.• 2 ¼" square hub
Earth Tension Anchors
Mfr. Model # Rod Tensile Strength Rod Diameter BSE Part #
12587 16,000 lbs. ⁵⁄₈" 130519
6512 23,000 lbs. or 36,000 lbs. ¾" or 1" 130406
Thimbleye EyenutFor power installed screw anchors (PISA). Eyenut has a galvanized fi nish.• RUS accepted
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
• Copper-coated • RUS listed
13
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model #Torque Rating
(ft./lbs.)Single Helix
Diameter Rod Diameter BSE Part #
E102-1632 6,000 8" ¾" or 1" 130258
E102-1633 6,000 10" ¾" or 1" 100407
E102-1634 6,000 12" ¾" or 1" 130259
Power Installed Screw Anchor HelixSingle-helice, galvanized anchor rod.• 1 ³⁄₈" square hub
Mfr. Model # Length Rod Tensile Strength Rod Diameter BSE Part #
12332P 7' 16,000 lbs. ⁵⁄₈" 130241
12632P 7' 23,000 lbs. ¾" 130520
PISA Anchor Rod PISA anchor rod with a galvanized coating.• RUS accepted
Tripleye® NutTripleye® eyenut for power installed screw anchors (PISA). • Galvanized
Mfr. Part# Rod Tensile Strength Rod Diameter BSE Part #
12593 16,000 lbs. ⁵⁄₈" 1719942
12585 23,000 lbs. or 56,000 lbs. ¾" or 1" 130518
Twineye® NutTwineye® eyenut for power installed screw anchors (PISA).
Mfr. Part# Rod Diameter BSE Part#
12589 ⁵⁄₈" 130514
6562 ¾" or 1" 130415
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Square Shaft Anchor Lead Section• Galvanized• 2 helices
Mfr. Part# StandardsSS RR Anchor Helix Diameter
Rod Length BSE Part#
012642AE RUS Accepted 8"–10" 3' 130278
12654-2EJ – 10"–12" 3 ½' 130242
Square ShaftGuy adapter for round rod or square shaft anchors.• Galvanized
Mfr. Part# Eyenut Style Length BSE Part#
C102-0023 Thimbleye® 18" 130048
C102-0024 Twineye® 18" 130049
C102-0025 Tripleye® 18" 130566
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Model # Dimensions Material Mounting Bolt BSE Part #
5004 ¼" x 1 ½" x 4 ¹⁄₈" Steel ¹¹⁄₁₆" 614306
Guy Hook – 1 Bolt Keeps guy wire from creeping downward in wrapped guy applications.• Hot-dip galvanized steel • Hooks should be used under bolt heads for maximum shear strength • RUS listed
Mfr. Model # Rod Diameter Eyenut Style BSE Part #
G5068 ¾", 1" Thimbleye 100210
Bonding Clamp• Aluminum construction • For use with PISA and tough one anchors• RUS listed
Guying
Since 1912
DOWN. RIGHT. SOLID.
14
Stay Ahead of the Storm with Border States
Surge Arresters
Mfr. Model # Mount Duty Cycle (kV) MCOV BSE Part #
213708-7324 Crossarm 9 7.65kV 1591991
213708-7333 Transformer 9 7.65kV 1591992
213709-7324 Crossarm 10 8.4kV 1587678
213709-7333 Transformer 10 8.4kV 1591997
213715-7324 Crossarm 18 15.3kV 1591979
213715-7333 Transformer 18 15.3kV 1719964
Heavy Duty Polymer Housed Surge Arrester Mounting hardware includes base bracket with isolator and cap.
Mfr. Model # Duty Cycle (kV) MCOV BSE Part #
221608-7314 9 7.65kV 884048
221609-7314 10 8.4kV 884058
Polymer Housed Riser Pole Surge Arrester Mounting hardware includes base bracket with isolator and cap.
Copper Wire with Bare Copper Conductor – Solid• Excellent corrosion resistance • Flexible; easily worked and formed into place • Good fatigue resistance; not subject to breaks due to nicks or cuts when terminating
Mfr. Model # Put-Ups Conductor Size (AWG) BSE Part #
BARE-SD-8-Sol.-CU-500R 500' Reel 8 2243920
BARE-SD-6-Sol.-CU-315R 315' Reel 6 2243917
Mfr. Model # Drive Rod Conductor Size (AWG) BSE Part #
GRC34 ¾" 8–1/0 122829
GRC58 ⁵⁄₈" 10–1 122804
Ground Rod Clamp For copper cable to rod. High copper alloy ground connector for joining a range of cable to copper clad, galvanized steel and stainless steel ground rods. • Slips over end of rod, one-wrench installation • UL467 listed for direct burial in earth and concrete • REA listed, CSA certifi ed
Grounding Equipment
Mfr. Model # Diameter Description BSE Part #
5/8X8FT ⁵⁄₈" 13 Mil 167955
Ground Rods Used for attaching ground wire to rod. Cu-REA style ground rod.
Guystrand Guy Wire• Class A, B, or C • Galvanized
Mfr. Model ## of
Strands LengthStrand
Size Class Grade BSE Part #
³⁄₈ 7 250' ³⁄₈" ASiemens-
Martin; A475 153766
Mfr. Model # Mounting Bolt BSE Part #
GH6 ¾" 100193
Guy Hook Ductile iron cast guy hook for down guy applications. The guy hook has a galvanized fi nish.
Since 1912
DOWN. RIGHT. SOLID.
15
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Type C Cutouts
Mfr. Model #System
Voltage (BIL) Interrupting Rating BSE Part #
CP710-112PB 15 kV (100 kV) 10,000 AIC 1410022
CP710-211PB 27 kV (100 kV) 8,000 AIC 1721589
Polymer Cutouts• Parallel-groove connector • NEMA “B” crossarm bracket
Mfr. Model # System Voltage (BIL) Interrupting Rating BSE Part #
CP720-112PB 15 kV (110 kV) 10,000 AIC 1410027
Linkbreak Polymer Cutout• Parallel-groove connector • NEMA “B” crossarm bracket
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Model # System Voltage (BIL) Interrupting Rating BSE Part #
CP730-112PB 15 kV (110 kV) 10,000 AIC 1410026
Loadbreak Polymer Cutout• Parallel-groove connector • NEMA “B” crossarm bracket
Mfr. Model # System Voltage Interrupting Rating BSE Part #
C710-112PB 15kV (110kV) 10,000 AIC 100176
Porcelain Cutout• Parallel-groove connector • NEMA “B” crossarm bracket
Mfr. Model # System Voltage (BIL) Interrupting Rating BSE Part #
C720-112PB 15 kV (100 kV) 10,000 AIC 100171
Linkbreak Porcelain Cutout• Parallel-groove connector • NEMA “B” crossarm bracket
Loadbreak Porcelain Cutout• Parallel-groove connector • NEMA “B” crossarm bracket
Mfr. Model # Material System VoltageInterrupting
Rating BSE Part #
C730-112PBPorcelain
Load Break15kV (110kV) 10,000 AIC 130150
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Border States is There When We Are Needed Most
When powerful storms strike and the power goes out, Border States understands the importance of having the right products and resources available when our customers need them the most. Every minute counts when the power is out and we make sure that the high demand products you need are available. We work side-by-side with you day or night doing whatever it takes to get the equipment, logistics and support you need when and where you need it.
16
Stay Ahead of the Storm with Border States
Crossarms & Braces
Mfr. Model # Span Drop BSE Part #
AF626 38" 18" 151332
No-Bolt Crossarm Braces• Unique extruded aluminum end fi tting delivers more strength, less weight, eliminates static-producing bolts, and looks better on the pole• Preservative treatment is standard, but may be offered untreated for environmentally sensitive applications
Mfr. Model # Span Drop BSE Part #
RA6018 60" 18" 151344
RA6030 60" 30" 151433
Wood Underarm Cross Arm Braces• Hole size at arm is ⁹⁄₁₆" and hole size at pole is ¹¹⁄₁₆"• Reversible
Mfr. Model # Put-Ups Conductor Size (AWG) BSE Part #
TIE 654' Box/25 lbs. 4 167053
TIE 654' Reel/25 lbs. 4 1738397
Aluminum Tie Wire Generally used in overhead transmission and distribution line construction.
Overhead Cable
Mfr. Model # Package Size Conductor Size Code Word BSE Part #
4 600 lbs., 8,955 ft. 4 AWG Swanate 1530997
2 885 lbs., 9,695 ft. 2 AWG Sparrow 1530996
1/0 885 lbs., 6,095 ft. 1/0 AWG Raven 1530993
4/0 1,770 lbs., 6,080 ft. 4/0 AWG Penguin 1531007
226.8 3,795 lbs., 10,330 ft. 226.8 kcmil Partridge 1576537
336.4 3,785 lbs., 8,195 ft. 336.400 kcmil Linnet 1531010
Aluminum Wire Overhead ACSR Designed to use as bare overhead transmission cable and as primary and secondary distribution cable.• ACSR offers optimal strength for line design • Variable steel core stranding enables desired strength to be achieved without sacrifi cing ampacity
Mfr. Model # Length Type BSE Part #
3-3/4X4-3/4X8FT 8' 3 161028
3-3/4X4-3/4X10FT 10' 5 161030
REA Distribution CrossarmRUS (REA) bulletin 1728H-701.
Composite Deadend Standard bracket assembly, for composite, concrete, metal, or wood poles.• Normal installation: No special equipment needed • Will not splinter and strength factors do not change • Impervious to insects, woodpeckers and weather • Double-guy attachment • 12" hole spacing• Color: Gray
Mfr. Model #Nominal Length
Number of Attachments
Number and Type of Positions BSE Part #
IDB120G12492 120" 9 4 Wire Positions 2261379
XDB120G12482 120" 8 4 Wire Positions 2359158
IDB096G12242 96" 4 2 Wire Positions 2359159
XDB096G12252 96" 5 2 Wire Positions 2367310
Deadend Crossarm
Mfr. Model # Length BSE Part #
HD-DEA-86-EB-REA 96" 151464
HD-DEA-108-EB-REA 120" 151438
Apitong Wood Heavy-Duty Deadend Assemblies• Installs with only two thru-bolts • Pre-drilled for standard pins • Light weight • High performance • No braces required • No special hardware or tools needed • Entirely factory assembled
17
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Length
Nominal Conductor Size Rods
Color Code
Conductor Diameter BSE Part #
AR-0110 40"#4, 6/1, 7/1 #4, 7W, Alum. Alloy
7 Orange .244"–.259" 161089
AR-0114 44"#2, 6/1, 7/1 #2, 7W Alum. Alloy
9 Red .309"–.326" 161091
AR-0118 52"1/0, 6/1 1/0, 7W
Alum. Alloy9 Yellow .390"–.413" 161092
AR-0124 60" 4/0, 6/1 11 Red .552"–.585" 161096
Aluminum Armor RodsIntended to protect against bending, compression, abrasion and arc-over, as well as to provide repair.• For use on: ACSR, compacted ACSR, aluminum alloy all-aluminum, AWAC® compacted all-aluminum, ACAR, ACSS (AW & TW)• Right-hand lay standard • Single-support length
Armor Rods
Mfr. Model #Nominal
Conductor Size LengthConductor Diameter BSE Part #
WTJ-0400#4, 6/1–7/1 – #4, 7W,
Alum. Alloy21" .248"–.259" 161261
WTJ-0406#2, 6/1–7/1 – #2, 7W,
Alum. Alloy23" .315"–.327" 161071
WTJ-04121/0, 6/1 1/0, 7W, Alum.
Alloy24" .395"–.411" 161203
WTJ-04173/0, AWAC, 5/2 4/0 19W,
Alum. Alloy28" .523"–.554" 161306
WTJ-04184/0, 6/1 4/0, 7W, Alum.
Alloy29" .555"–.594" 161447
WTJ-0422336.4, 26/7-30/7 397.5,
19W, Alum. Alloy32" .706"– .747" 918617
WRAPLOCK™ Tie J-Neck Ties secure conductors in the top groove of interchangeable head-style insulators• For use on: ACSR, compacted ACSR, aluminum alloy, all-aluminum AWAC®, compacted all-aluminum • Green insulator identifi cation mark • Right-hand lay standard • 3 ½" neck diameter• Color code: orange
Conductor Tie
Mfr. Model # Nominal Conductor SizeGroove Radius Diameter BSE Part #
UTC-1104#2, 6/1, 7/1 - #2, 7W
Alum. Alloy #1, 6/1 ⁹⁄₁₆" .32"–.36" 161205
UTC-11051/0, 7W All Alum. 1/0, 6/1
1/0, 7W Alum. Alloy ⁹⁄₁₆" .36"–.41" 161080
UTC-11084/0, 7W All Alum. 4/0, 6/1
4/0, 7W Alum. Alloy ⁹⁄₁₆" .52"–.59" 161275
UTC-1109266.8, 37W All Alum.
266.8, 18/1 ⁹⁄₁₆" .59"–.67" 161380
C-Neck Distribution Tie Distribution ties manufactured of aluminum covered steel secure conductors in the top groove of interchangeable head style insulators.• For use on: ACSR, compacted ACSR, aluminum alloy, all-aluminum AWAC®, compacted all-aluminum • Insulator identifi cation mark: black• Color code: yellow• Applied length: 30"• Right-hand lay standard • 2 ¼" neck diameter
Mfr. Model #Nominal
Conductor Size Length Conductor Dia. BSE Part #
WTC-0100#4, 6/1 –7/1; #4, 7W
Aluminum Alloy19" .248"–.259" 161152
WTC-0106#2, 6/1 –7/1; #2, 7W
Aluminum Alloy21 ½" .315"–.327" 161151
WTC-01121/0, 6/1 1/0, 7W,Aluminum Alloy
21" .395"–.411" 161154
WTC-01142/0, 6/1-7/1 2/0, 7W,
Aluminum Alloy23" .438"–.463" 161202
WTC-01173/0, AWAC, 5/2 4/0,
19W, Aluminum Alloy26 ½" .523"–.554" 161189
WTC-01184/0, 6/1 4/0, 7W, Aluminum Alloy
27 ½" .555"–.594" 161157
WTC-0122336.4, 26/7-30/7 397.5,
19W, Aluminum Alloy30 ½" .706"–.747" 161254
WRAPLOCK™ Tie C-Neck Ties secure conductors in the top groove of interchangeable head-style insulators.• Nominal conductor size: #4, 6/1-7/1; #4, 7W aluminum alloy• For use on: ACSR, compacted ACSR, aluminum alloy, all-aluminum AWAC®, compacted all-aluminum • Insulator identifi cation mark: black• Color code: orange• Right-hand lay standard • 2 ¼" neck diameters
18
Stay Ahead of the Storm with Border States
Mfr. Model # Neck Type Voltage Standards kV Rating BSE Part #
5R C Low ANSI 55-3 11.5 kV 167383
6R F Low ANSI 55-4 13.2 kV 167389
27R J High ANSI 56-1 14.4 / 23 kV 167394
Pin Type Insulators• Special designs for use in areas of high contamination• Low voltage pin types are manufactured and tested to the requirements of ANSI standard C29.5• High voltage pin types to ANSI Standard C29.6• RUS listed
Mfr. Model # Voltage Rating ANSI BSE Part #
HPI-15 15kV 55-3 970718
HPI-15F 15kV 55-4 129404
HPI-25J-02 25kV 56-1 2245314
Polyethylene Tie Top Pin Type Insulators• May be used with bare conductors • Will fi t on standard 1" or 1 ³⁄₈" pins • Electrically compatible with covered conductors —no stripping is required • For use with hand wrapped or pre-shaped ties• Resistant to impact damage, breakage and vandalism • Interchangeable with porcelain insulators
Mfr. Model # Length Neck Type Standards BSE Part #
HPI-53-2 3 A ANSI 53-2 1984694
Polyethylene Spool Insulators Molded of proprietary gray track resistant, high density polyethylene.• Resistant to breakage, chipping, cracking and vandalism • Direct replacement for porcelain • RUS accepted • ANSI specifi cations: C29.1 and C29.3
Deadend Suspension Insulator
Mfr. Model #System
Voltage (kV)Section Length
ANSI Critical Impulse FO - Positive BSE Part #
401015-0215 15 12 ½" 140kV 160890
401025-0215 25 or 35 18 ¾ " 260kV 160907
401028-0215 25 17 ½" 200kV 160981
401035-0215 35 or 46 25" 325kV 160895
Insulators
Manual Hoist and Puller All components rated for 750 lbs. working load. Not personal protective equipment, these are not for human support.• Galvanized steel body and hooks
Mfr. Model # Type Weight BSE Part #
PSC4032935 Flat Hook 1 lb. 2239475
Mfr. Model # Type Weight BSE Part #
PSC4032936 Complete Block and Tackle Set 4.25 lbs. 2239476
PSC4032934 Swivel Hook 1 lbs. 2237246
Hooks All components rated for 750 lbs. working load. Not for personal protective equipment, these blocks and hooks are not for human support.• 30' x ¹⁄₈" diameter braided poly rope (only with block and tackle set) • Galvanized steel body and hooks
Load Handling Equipment
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Model # Length Neck Type Standards BSE Part #
VI-2612 3" A ANSI 53-2 1580016
Porcelain Spool Insulators• Designed to meet ANSI specifi cations: C29.3 requirements• RUS accepted
19
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model #
Load Rating (tons) Style
Standard Lift
Distance
Handle Pull at Rating
Hook-to-Hook Minimum BSE Part #
3011S 1 Link Chain 5.5' 90 lbs. 11" 130348
Ratchet Hoists Proof-tested and factory-operated at 150% capacity rating.• Two levers—shift key (on top housing) for up and down; release key (in handle recess)• Forged steel load hooks with spring-loaded latches • Ratchet handle swings to either side • Top and bottom hooks swivel 360°
Universal Cutout Tool 4-in-1 tool for 100A fuse holders and Chance® Electronic Sectionalizer.• Works on major brands of cutouts for easy lift out, placement, opening and closing operations • Holds fuse holder in inverted position • Not for use with loadbreak cutouts
Mfr. Model # BSE Part #
PSC4033484 1989598
Tools
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Model # Rating Weight BSE Part #
PSC6010342 27 kV 12 lbs. 2110340
Temporary Cutout and Load Disconnect Tools Provides fuse protection during live line maintenance.• Bronze stud at the lower end accepts the clamp of a temporary tap jumper • Excellent loadbreak capability• Tools simply clamps onto a primary conductor with a Grip-All clampstick
Since 1912
DOWN. RIGHT. SOLID.
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Part# Length Tool Type BSE Part#
C403-0292 6' 6" Grip-All Clampstick “Shotgun” 100092
C403-0293 8' 6" Grip-All Clampstick “Shotgun” 100093
Mfr. Part# Retracted Length Style Length BSE Part#
T403-2205 28" Compact Standard 8' 130552
C403-1021 65" Standard Duty 30' 100119
C403-1022 67" Standard Duty 35' 100115
Telescoping StickPerform many routine jobs from ground level.• Spring-loaded plastic buttons keep extended tool sections locked in position• Universal end fi tting
Since 1912
DOWN. RIGHT. SOLID.
Single-Piece Clamp StickEasy-to-control “fi nger” on an insulated pole.
Since 1912
DOWN. RIGHT. SOLID.
Mfr. Model # Dimensions Battery Size Battery Type BSE Part #
160026.2 in (L) x 2.3 in (W)
x 0.9 in (H)3 AAA
Lithium / Alkaline Disposable 2472417
LitLink™ Hotstick Accessory Light Provides illumination when using hotstick accessories such as disconnect hooks, tie heads and hacksaws, etc.• Bright, unbreakable 1-watt LED light • HI-LOW switch for increased battery life • Water resistant battery compartment with sealed silicone rubber push button • Sealed borosilicate window to resist heat and fl ash • Universal splined slotted connector attaches to hot sticks
• Designed for installing hot line and grounding clamps• Insulated parts• Lexan® tool head
• Serve both overhead and underground circuits with various fi ttings
20
Stay Ahead of the Storm with Border States
Mfr. Model # Service Ampere Rating Connectors CU/AL BSE Part #
U7487-RL OH/UG 125A (AWG): 6–2 149111
125A 4-Terminal Ringless Meter Socket• Accepts 5th terminal • Single position• Hub provision: hub opening
Mfr. Model # Connectors CU By-Pass BSE Part #
U7040-XL-TG #6-350 kcmil – 149102
U4801-XL-5T9 #6-350 kcmil Lever 1414906
200A 4-Terminal Ringless Meter Sockets• Accepts 5th terminal• Hub provision: closing plate• H/UG service
Meter Sockets & Accessories
Mfr. Model # Hub Size BSE Part #
A7516 1 ½" 148792
A7517 2" 148801
Hubs for Meter Sockets
Mfr. Model # Trade Size BSE Part #
SH105 1 ½" 162218
SH106 2" 162223
Steel City® Aluminum Service Cap Clamp type for rigid/intermediate or thinwall.
Service Entrance Fittings
Mfr. Model # Size Thickness BSE Part #
88-SUPER-3/4X66FT ¾" x 66' 8.5mil 114866
Super 88 Vinyl Electrical Insulating Tape• Resists weather, UV resistance, abrasion and corrosion• Temperature rating: 220° F
Tape
Mfr. Model # Output Dimensions
Battery Size Battery Type BSE Part #
1600132 lm (high) / 12 lm (low)
5.7 in (L) x 4.9 in (W) x 0.9 in (H)
3 AAALithium / Alkaline
Disposable1723164
LitFinger™ Illuminated Disconnect Hook Fuse barrel replacement is easier and safer because the LitFinger features bright light that illuminates your task.• Bright, unbreakable 1-watt LED light • Pointed head for breaking off of ice or debris • Notched straight arm to secure fuse while lowering or raising hot stick • Curved arm for hanging • HI-LOW switch for increased battery life • Water resistant battery compartment with sealed silicone rubber push button • Sealed borosilicate window to resist heat and fl ash • Universal splined slotted connector attaches to hot sticks
Mfr. Model # Length Width Thickness Color BSE Part #
2234 6 ft 2 in 60 Milli-inch (mil) Black 2400801
3M, Scotch® Cable Jacket Repair Tape 2234 Allows for on-site, quick repair of cable jackets and is proudly made in the USA.• Durable and fl exible • On-site, quick, universal cable repair • Abrasion, water, UV, chemical and oil resistant, heavy duty backing • No heat required • Moisture-resistant, self-healing, fl ame retardant mastic • Will not corrode copper or aluminmum conductors
21
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Length Width BSE Part #
33+SUPER-3/4X66FT 66' .8" 114863
Scotch™ Super 33+ Vinyl Electrical Tape Primary insulation for wire cable splices up to 600 V and for fi xture and wire splices up to 1000 V.• Resists UV rays, abrasion, moisture, alkalies, acids and corrosion • Premium-grade, 7-mil tape that applies well at 0°F and has an operating range up to 220°F • Flame retardant, hot and cold weather resistant
Flashlights and Lamps
Mfr. Model # Length Output Typical Runtime BSE Part #
51012 9.02"
Xenon: Up to 57 Lumens Typical; (6)
LEDs: Up to 52 Lumens Typical; (3) LEDs: 28
Lumens Typical
Xenon: Up to 5 Hours; (6) LEDs: Up to 100 Hours; (3) LEDs: Up to
160 Hours
1720930
Twin-Task 3C Titanium Flashlights• Patented xenon/LED combination for brightness and long run time• Enhanced knurled grip for easy handling • Micro-faceted refl ector • O-ring sealed for water resistance • Color: titanium
Mfr. Model # Output Color BSE Part #
61050 TridentXenon: 18 Lumens Typical
(3) LEDs: 24 Lumens Typical (1) LED: 9 Lumens Typical
Yellow 1720933
Trident® Headlamp Three-position lighting: xenon bulb, 1 LED and 3 LEDs.• Includes 3 AAA batteries, rubber hard hat strap and adjustable elastic head strap • Water-resistant, lightweight thermoplastic construction• Spot-to-fl ood focus • 1 50 hours of run time on 1 LED • Push button switching• 90º tilting head
Mfr. Model # Output Color BSE Part #
61052 Septor(7) LEDs: 50 Lumens Typical (3) LEDs: 25 Lumens Typical
(1) LED: 9 Lumens TypicalYellow 1720932
Septor® Headlamp• 90º tilting head • Includes 3 AAA batteries, rubber hard hat strap and adjustable elastic head strap • Water-resistant, lightweight thermoplastic construction• 150 hours of run time on 1 LED • Push button switching
Mfr. Model # Output LED BSE Part #
CAPW2BBP 14 lumens per LED White 2475757
Energizer, Cap Light Hands-free light attaches to the brims of caps and visors.• Over the brim design does not obstruct vision • Flood beam for wide, close-up illumination • Recessed push button switch to prevent inadvertent activation • Three Nichia® LEDs
Disaster and Storm Recovery
Border States carries a wide variety of safety stock materials for disaster and emergency recovery. We also have strategic partnerships in place with manufacturers that give us access to emergency material at their warehouses. With emergency mobilization plans in place, we are prepared to get the emergency recovery material out when you need it most. Our delivery trucks, logistics expertise, dedicated emergency stock and experienced staff are there to deliver what you need, where you need it, ensuring a quick and effi cient recovery.
22
Stay Ahead of the Storm with Border States
Safety/Apparel
Mfr. Model # Output Typical Runtime Color LED BSE Part #
7150031 Lumens
Typical
4 Hours Max Intensity; 2 Hours Additional
Declining Useable OutputBlack White 1720931
Luxeon Flashlight 50,000-hour Luxeon LED with the brightness and range of a conventional bulbs.• Push-button tailcap for steady on and momentary on/off • Shock and water resistant • Ultra Small: 6.5" long and Lightweight: only 3.8 oz. • Powered by 2 AA alkaline batteries • Includes: holsters, helmet clamps, and a clip holder
Mfr. Model # Color Bulb BSE Part #
68202 Yellow White LEDs 1720934
4 AA Propolymer® LED Series Remarkably comfortable to use because it is ergonomically shaped for your hand.• 27 lumens typical with 7 white LEDs • Powered by 4 AA alkaline batteries • Features a wrist lanyard connection • Run time of up to 155 hours• Helmet clamps are available for convenient, hands-free operation• Batteries included
Mfr. Model # Color Output BSE Part #
45117 Yellow 150 Lumens Typical 1720908
LiteBox®
Portable, powerful, industrial-duty, rechargeable lantern with 90° swivel head lets you aim the super-bright light in any direction.• Includes shoulder strap, AC and DC chargers and charge rack
Mfr. Model # Lens Frame BSE Part #
SB1810ST Clear Anti-Fog Black 1249400
SB1810S Clear Black 1249401
SB1860SF Light Blue Black 1249060
SB1820S Gray Black 1249399
SB1830S Amber Black 1249063
SB1860S Infi nity blue Black 1249059
SB1880S I/O Mirror Black 1249072
SB1890S Gold Mirror Black 1249071
SMB1810S Clear Metallic Blue 1249066
SMM1810S Clear Maroon 1249044
Venture II™ Safety Glasses Fully adjustable temples feature 4 size settings.• 9.75 base curved lens provides full side protection • Meet ANSI Z87.1-2003 high velocity impact standard • 99% protection against UV rays • Lens coated for superior scratch resistance
Mfr. Model # Package Quantity BSE Part #
696688 10 2400763
Terri-Band Sweatband Custom design fi ts all MSA helmets.• Washable • Plastic snaps
Mfr. Model # Battery Size BSE Part #
PC2400 AAA 1573045
PC1500 AA 1944694
PC1400 C 1944693
PC1300 D 1935321
PC1604 9 V 1944695
PROCELL® Alkaline Batteries Engineered for devices consumers use most.
23
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Foam Ear Plugs Soft, comfortable and unobtrusive hearing protection.• Hypo-allergenic material • Recommended for high noise situations (up to 100 dBA TWA)
Mfr. Model # Description Pkg. QuantityCorded or Uncorded BSE Part #
29008 29 dB NRR 1,000/Case Uncorded 720324
29009 29 dB NRR 500 Pairs/Case Corded 720403
Mfr. Model # Type Dimensions Weight (lbs.) BSE Part #
PSC6003345 Singe Unit 58" x 58" 5 2239472
PSC6003346 Singe Unit 58" x 120" 10 2239473
PSC6003347 Singe Unit 120" x 120" 20 2239474
PSC6003349 Kit 58" x 120" 17 2089068
Slip-Resistant Equi-Mat™ Personal Protective Ground GridProvides an easy way to help establish an equipotential zone for a line worker to stand on during various energized and de-energized work practices.• For rain, snow and ice conditions, the napped surface of the slip-resistant Equi-Mat™ personal protective ground grid offers superior footing • Complies with OSHA 1910.269 for equipotential requirements near vehicles, underground gear, overhead switches, and in substations
Mfr. Model # Color Vest Size BSE Part #
8230Z Lime S/M 1680966
8230Z Lime L/XL 1680967
8230Z Lime 2XL/3XL 1680968
8230Z Lime 4XL/5XL 1680969
GloWear® Class 2 Two-Tone Vest ANSI certifi ed polyester mesh.
Mfr. Model # Color Vest Size BSE Part #
8210HL Lime S/M 1680943
8210HL Lime L/XL 1680944
8210HL Lime 2XL/3XL 1680945
8210HL Lime 4XL/5XL 1680946
GloWear® Class 2 Economy Vest ANSI certifi ed polyester mesh.• 2" ANSI certifi ed refl ective tape, (1) 360°, (2) Vertical • Hook and loop closure • One inside pocket
Mfr. Model # Color Size BSE Part #
8260FRHL Lime S/M 2447753
8260FRHL Lime L/XL 2447754
8260FRHL Lime 2XL/3XL 2447755
8260FRHL Lime 4XL/5XL 2447757
GloWear® Class 2 Flame Resistant (FR) Modacrylic Vest ASTM F1506-certifi ed modacrylic mesh fabric.• 3M™ Scotchlite™ FR Refl ective Material, 2" Level 2 ANSI-certifi ed • Fabric passes ASTM F1506; ATPV of 5.0 cal/cm² • FR hook and loop closure • D-ring access slot • Pockets: One inside, on dual pen pocket
• 2" level 2 ANSI certifi ed tape with 4.5" contrasting color (3M Scotchlite), (1) 360°, (2) vertical • One inside pocket • Zipper closure
Mfr. Model # Description Size BSE Part #
RS70032S3M6Slim Line Cone w/ one 6"
3M Refl ective Collar28" Height x
12" Base 1721902
JBC Safety Plastic, Traffi c Cones - Revolution Series The Revolution Series is manufactured using premium grade PVC injection molding technology, resulting in the most durable traffi c cones available on the market.
TM
24
Stay Ahead of the Storm with Border States
Moisture Eater II Wipes Clean insulated hot-line tools, line hose and rubber blankets.• 1/2 oz. orange-scented Moisture Eater II solvent on each wipe • Does not contain chlorinated solvents harmful to the ozone • Help utilities stay in compliance with OSHA 29 CFR 1910.269(j) • Small pocket-size packets• Low evaporation rate • Premoistened, lint-free towel
Mfr. Model # Color Size BSE Part #
6821 Black One Size Fits All 1593203
6821 Cool Series Balaclava
Mfr. Model # Description BSE Part #
6990 Warms up to 8 Hours 1720746
Chill-Its™ Warming Packs A sure-fi re way to snap into instant warmth. Simply break to activate fast, radiant relief from the cold.• Warms up to 8 hours • Disposable, non-toxic
Mfr. Model # Case Quantity BSE Part #
8511-N95 80 964145
8511 Respirator Mask Helps reduce exposure to dust from sanding on particle board, drywall, non-lead paints and fi berglass insulation.• Cool Flow™ exhalation valve makes it comfortable when heat and humidity are present • Light weight construction • M-nose clip
Mfr. Model # Package Quantity BSE Part #
46457 160 Per Case/20 Per Box 788780
N95 Particulate Respirator Protection against non-oil based particles.• 3M’s Advanced Electret Media • Features welded strap attachment, soft nose foam and adjustable nose clip • Light weight
Mfr. Model # Color BSE Part #
475369 White 1751575
475366 Yellow 2306553
MSA® V-Gard™ Hat Style Protective Helmet Full brim protective non-slotted helmet with Fas-Trac™ suspension.• Size is standard 6 ½ – 8
Mfr. Model # Color BSE Part #
475358 White 2306649
475359 Blue 2262893
475360 Yellow 2262915
475361 Orange 2400723
475362 Green 2400724
475363 Red 2400725
475364 Hi-Visability Orange 2400726
488146 Hi-Visability Lime 2400761
V-Gard™ Cap Style Protective HelmetProtective slotted helmet with Fas-Trac® suspension and front brim.• Size is standard 6 ½ – 8
Mfr. Model # Color Size Cal/cm2 Rating BSE Part #
H11BA Black One Size Fits All 11.6 2258341
Flame-Resistant Single-Layer Balaclava• 55% Modacrylic® 45% cotton • Soft and comfortable with fi nished edges throughout• Extra long neck skirt • Machine washable • Single-layer
• Long length • Polyester fl eece • Single-wash FR treated
Mfr. Model # Package Size BSE Part #
C400-2538 50 101016
25
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Color Size BSE Part #
H31BA Black One Size Fits All 2258338
Flame-Resistant Double-Layer • 55% Modacrylic® 45% cotton • Soft and comfortable with fi nished edges throughout• Cal cm2/EBT rating: 11.6 for the single fabric on collar • Cal cm2/EBT rating: 23.2 for the double-lined hood • Extra long neck skirt • Machine washable
Mfr. Model # BSE Part #
6952 1579910
Chill-Its™ 6952 Extreme Series 3-Layer Winter Liner• Elastic gap control at forehead keeps warmth in and cold out • Warming pack pockets near ears for extra warmth• Shoulder length • Chin wrap • FR treated for safety • Lining: 100% poly sherpa • Shell: 100% quilted nylon • Mid-layer: foam • Black w/white • Refl ective strip and suspension ties • One size fi ts all
Mfr. Model # Description Glove Size BSE Part #
6815 6815 Cool Series Winter Liner One Size Fits All 1579908
Chill-Its™ 6815 Cool Series Winter Liners• 100% polyester knit • Full-face style stretch tube winter liner • FR treated • Black • One size
Duck Vest/Quilt LinedHazard Risk Category 4 Outerwear ARC RATING 56.3 cal/cm2.• 100% cotton• Brass front zipper with Nomex® zipper tape has inside and outside protective fl ap and hidden snap closure for electric arc protection• Inside patch pocket with hook-and-loop closure on left side for added convenience
Mfr. Model # Size Color HRC ATPV
FRV036 S-4XL, Tall Carhartt Brown 4 50.4
Duck Traditional Coat - Quilt LinedHazard Risk Category 4 Outerwear ARC RATING 50.4 cal/cm2.• Nomex® inside waist drawcord for adjustment• Nomex® rib-knit storm cuff to seal out cold air• INDURA® corduroy top collar with snaps under collar for optional FR hood
Mfr. Model # Size Color HRC ATPV
FRC56 Regular S-4XL, Tall Carhartt Brown 4 50.4
FLAMERESISTANT
Duck Bomber Jacket - Quilt LinedHazard Risk Category 4 Outerwear ARC RATING 56.3 cal/cm2.• Two-way brass front zipper with Nomex® zipper tape • Zipper front has inside and outside protective fl ap and hidden snap closure for electric arc protection• Two inside patch pockets with FR hook and loop closure for convenient storage• Nomex® rib-knit storm cuff and waistband to seal out cold air• INDURA® corduroy top collar with snaps under collar for optional FR hood
Mfr. Model # Size Color HRC ATPV
FRJ195 Regular S-5XL, Tall Carhartt Brown 4 50.4
FLAMERESISTANT
FLAMERESISTANT
26
Stay Ahead of the Storm with Border States
Neopreneknuckle pad
Mfr. Model # Length Class Size BSE Part #
E216BCYB-11 16" 2 11 2107129
Lineman's High Voltage GlovesAccomodates heavier winter clothing and allows for greater air fl ow in warmer weather. • Bell cuff• Yellow inside/black outside
817Mfr. Model # Size Color BSE Part #
817L Large Black 1527591
817XL X-Large Black 1527592
817XXL 2X-Large Black 1579907
817 WP WaterproofMfr. Model # Size Color BSE Part #
817WPL Large Black 1527591
817WPXL X-Large Black 1527592
817WPXXL 2X-Large Black 1579907
Duck Hood - Quilt LinedHazard Risk Category 4 Outerwear ARC RATING 50.4 cal/cm2. • Three-piece hood design for better fi t• Arc-resistant snaps for attachment to FR outerwear• Chin protector with FR hook and loop closure• Nomex® drawcord for adjustment
Mfr. Model # Size Color HRC ATPV
FRA65 One Size Fits All Carhartt Brown 4 50.4
Duck Bib Overall - Quilt LinedHazard Risk Category 4 OuterwearARC RATING 56.3 cal/cm2.
• Zip-to-mid-thigh brass leg zippers with Nomex® zipper tape and protective fl ap and arc resistant snap closure• Right leg has tool pocket, left leg has hammer loop and ruler pocket • High back with FR elastic suspenders and high-temperature nylon center-release buckles• Chap-style double front for durability and increased thermal performance• Brass fl y zipper with Nomex® zipper tape
Mfr. Model # Size Color HRC ATPV
FRR44Inseam: 30-36" Waist: 30-54" Carhartt Brown 4 50.4
FLAMERESISTANT
FLAMERESISTANT
Mfr. Model # Size BSE Part#
77-298L Large 1751584
77-298XL XL 1751585
Insulated Top Grain Cowhide Drivers Gloves• Fleece pile lining• Keystone thumb style• Made from premium grade cowhide
ProFlex® 815 Utility EZ Gloves• Amara synthetic palm and fi ngers provide durability, dexterity and comfort• Terry cloth upper thumb handy for sweat absorption• Full fi nger design• Breathable air-mesh back• Gauntlet cuff• Reinforced fi ngertips
Mfr. Model # Size Color BSE Part #
815L Large Black 1527582
815XL XL Black 1527583
817 Insulated Mechanics Glove817WP Insulated Waterproof* Mechanics Glove• 40g 3M™ Thinsulate™ insulation• Woven elastic cuff with hook and loop closure• Padded spandex back• Double reinforced Amara palm• Neoprene knuckle pad• Terry thumb brow wipe*817WP features a Hipora waterproof and windproof liner
SALISBURY
Reinforced palm
27
borderstateselectric.com | Emergency HELP Line: 800.800.0199
BSE IS YOUR SOURCE FOR EMERGENCY MATERIALS
Mfr. Model # Container BSE Part #
02016 16 Oz Aerosol 117833
CO™ Contact Cleaner HFE and HFC solvents offer alternative to CFC, HCFC and fl ammable contact cleaners. • Evaporates quickly and leaves no residue• High dielectric strength of 27,600V• Non-chlorinated, non-staining and noncorrosive• Nonfl ammable• NSF K2• Safe on plastics
Contact Cleaner 2000™ Precision Cleaner General purpose cleaner for removing dirt, light oils and other contaminants. • Effective alternative to CFC-113 based cleaners in electrical and electronic cleaning applications• Non-conductive, noncorrosive and chemically stable• Evaporates quickly and leaves no residue• No fl ash or fi re point
Mfr. Model # Container BSE Part #
02140 16 Oz Aerosol 117892
Mfr. Model # Packaging BSE Part #
18412 16 Oz Aerosol 118037
2-26™ Multi-Purpose Precision Lubricant Helps prevent electrical malfunctions caused by water penetration, humidity, condensation, or corrosion.• Cleans light soils and contaminants• Cleans, lubricates, penetrates and loosens corrosion• Restores resistance values and helps stop current leakage• Protect against corrosion• NSF H2• Safe on plastics
Mfr. Model # Container BSE Part #
02005 16 Oz Aerosol 117819
Zinc-It™ Instant Cold Galvanize• Actively fi ghts rust and corrosion with a fi lm of 95% pure zinc • Fast-drying—dries to the touch in 15 minutes• Excellent weldability
ProFlex® 710 Full-Fingered Trades Gloves• Soft, fl exible and durable Amara™synthetic leather palm and fi ngers and reinforced thumb/index fi nger saddle• PVC palm for secure grip and longer wear• Akton™ polymer gel absorbs impact• Woven elastic cuff for a comfortable fi t• Micro-injected closure for quick cinching
Mfr. Model # Size Color BSE Part #
710L Large Black 1928494
710XL XL Black 1928498
710XXL XXL Black 1928531
Cleanup
Mfr. Model # Size BSE Part #
42272 72 Towel Container - Citrus Fragrance 1532843
Dymon, SCRUBS ® Hand Cleaner Towels• SCRUBS® patented, dual-textured towels lock in dirt and will not transfer soils back onto hands • Leave your hands clean, no rinsing necessary
Mfr. Model # Container BSE Part #
02018 20 Oz Aerosol 117840
Lectra Clean™ Heavy-Duty Degreaser Quickly and effectively removes grease, oil, tar, adhesives, dirt, grime, corrosion, sludge and other stubborn substances. • Evaporates quickly and leaves no residue• Noncorrosive, non-staining, and non-conductive • High dielectric strength of 36,700V• No fl ash or fi re point
Mfr. Model # Package Size BSE Part #
C400-2568 50 918602
Hubbell Power, Silicone Wipes For insulated hot-line tools.• Wipes remove dust while depositing a thin protective coat against contaminants• Help utilities stay in compliance with OSHA 29 CFR 1910.269(j)• Silicone-saturated 8” x 10” lint-free towel • Small pocket-size packets• Disposable
Missoula
Billings
Gillette
Williston
Bismarck
MinotFargo
Rapid City
Sioux Falls
Dickinson
GrandForks Bemidji
St. CloudWillmar
MarshallMankato Rochester
Faribault
Brooklyn Park
KingsfordAlexandria
Pewaukee
Cedar Rapids
GrandHavenJanesville
Clarksville
ColumbiaNashville
Hendersonville
Murfreesboro
Lebanon
Denver
Albertville Eau Claire
Brownsville
A 100% Employee-owned, American Company
BORDER STATES LOCATIONS
Form#40-110 (04-12)©2012 Border States Industries, Inc.
ARIZONAPhoenix 5519 E Washington StPhoenix AZ 85034602.244.0331 Tucson 763 E MacArthur CircleTucson AZ 85714520.294.1414 COLORADODenver 4686 Ivy StDenver CO 80216303.336.7360 IOWACedar Rapids 2515 18th St SWCedar Rapids IA 52404319.366.2868 MICHIGANGrand Haven 1734 A Airpark DriveGrand Haven MI 49417616.842.2382 Kingsford 201 N Hooper StKingsford MI 49802906.774.1641 MINNESOTAAlbertville11927 53rd St NEAlbertville MN 55301763.497.6800 Alexandria 906 State Highway 29 NAlexandria MN 56308320.763.5131 Bemidji 3405 Hannah Ave NWBemidji MN 56601218.759.1350 Brooklyn Park9100 Wyoming Ave NSte 550Brooklyn Park MN 55445763.425.5500 Faribault 1503 30th St NWFaribault MN 55021507.334.4301 Mankato 2800 3rd AveMankato MN 56002507.388.1241 Marshall 609 S 4th StMarshall MN 56258507.532.4429 Rochester 100 Carlton St SWRochester MN 55902507.280.4670 St. Cloud 2800 1½ St S St. Cloud MN 56301320.251.1761 Willmar 1209 E Highway 12 Willmar MN 56201320.235.2255 MONTANABillings 206 S Plainview St Billings MT 59101406.256.6266 Missoula 101 S Catlin StMissoula MT 59801406.549.4115
NEW MEXICOAlamogordo 351 Panorama BlvdAlamogordo NM 88310575.434.2022 Albuquerque 5601 Jefferson St NEAlbuquerque NM 87109505.344.1313 Clovis 817 Lexington RoadClovis NM 88101575.762.3393 Farmington 865 S Browning Parkway Farmington NM 87401505.324.8800 Hobbs 100 W Navajo DriveHobbs NM 88240575.392.1212 NORTH DAKOTAFargo 105 25th St N Fargo ND 58102701.293.5833 Bismarck3205 E Thayer Ave Bismarck ND 58501701.258.6060 Dickinson 1917 I-94 Business Loop Dickinson ND 58601701.225.4466 Grand Forks 2104 Mill Road Grand Forks ND 58203701.772.3477 Minot 101 40th Ave NWMinot ND 58703701.837.1130 Williston113 26th St E Williston ND 58801701.572.1577 SOUTH DAKOTARapid City 3100 East Mall DriveRapid City SD 57701605.348.5104 Sioux Falls 1401 N Minnesota AveSioux Falls SD 57104605.331.4454
TENNESSEEClarksville 1891 Wilma Rudolph BlvdClarksville TN 37040931.552.6580 Columbia 1512 Nashville HighwayColumbia TN 38401931.381.6211 Cookeville 1055 Highway 111 SCookeville TN 38501931.520.5900 Hendersonville 101 New Shackle Island RoadHendersonville TN 37075615.824.7261 Lebanon 509 Baddour Parkway WLebanon TN 37087615.444.5613 Murfreesboro 680 Middle Tennessee BlvdMurfreesboro TN 37129 615.895.3235 Nashville 656 Wedgewood AveNashville TN 37203615.255.4161 TEXASAbilene 2250 Industrial BlvdAbilene TX 79602325.698.4595 Amarillo 700 S Adams StAmarillo TX 79101806.457.4100 Austin 622 Morrow StAustin TX 78752512.458.6313 Big Spring 3202 I-20 EBig Spring TX 79720 432.263.7832 Brownsville 2781 Robindale RoadBrownsville TX 78521956.831.3441 Edinburg 2308 W Trenton RoadEdinburg TX 78539956.618.2874
El Paso 8101 Lockheed DriveEl Paso TX 79925915.771.7767 Harlingen 1101 W Jackson StHarlingen TX 78550956.428.1613 Lubbock 520 E 50th St Lubbock TX 79411806.765.5741 Lubbock Spur 5902 Spur 327Lubbock TX 79424806.797.2697 Midland 3303 W Illinois AveSte AMidland TX 79703432.520.0230 Odessa 850 W University BlvdOdessa TX 79764432.332.0591 San Angelo 502 N Bryant BlvdSan Angelo TX 76903325.655.9163 WISCONSINEau Claire 3505 Melby RoadEau Claire WI 54703715.831.6435 Green Bay 2216 Angie AveBuilding 8 Section 2Green Bay WI 54302920.288.0019 Janesville 1855 S Jackson StJanesville WI 53546608.373.0229 Pewaukee N29W23606 Woodgate Court EPewaukee WI 53072262.347.2199 WYOMINGGillette 3602 S Douglas HighwayGillette WY 82718307.682.6777