for sun high end storage(usp-v) - next technologies · 5 toi for sun high end storage(usp-v) orange...
TRANSCRIPT
transfer of information(toi)for sun high end storage(usp-v)
Nazmul KhanNazmul Khan
Technical Account Manager
System Infrastructure (Maintenance)
20 November 2009, Singapore
Agenda
� Introduction of HW/Server, Storage, Tape Library.
Introduction of RAID System.� Introduction of RAID System.
� Storage Product @ Sun Microsystems/HDS
� High End Storage (USP-V) Structural/physical diagram
� High End Storage (USP-V) Software Service
� Storage Navigator overview
Support Data
2 TOI for Sun High End Storage(USP-V) Orange Business Services
� Support Data
� Q & A
Introduction
� 1. Introduction of HW/Server, Storage, Tape Library.
� 1.1 Introduction of x86/Sparc/RISC/iSeries/pSeries/xSeries Server.
1
� 1.2 Introduction of SCSI/SATA/FC Storage.
� 1.3 Introduction of JBOD/Controller base Storage.
� 1.4 Introduction of SCSI/SATA/FC Tape Library.
� 1.5 Introduction of Virtual Tape Library.
SAN = Storage Area Network
NAS = Network Attach Storage
3 TOI for Sun High End Storage(USP-V) Orange Business Services
NAS = Network Attach Storage
RAID = Redundant Array of Independent disks
JBOD = Just A bunch of disks
MPIO =Multi Path IO (load balance/failover)
LUN = Logical Unit Number
LDEV =Logical Device
Introduction of RAID System
� 2. Introduction of Redundant Array of Independent disks (RAID) System.
2 1
System.
� 2.1 Hardware RAID.
� 2.2 Software RAID. RAID
HW SW
4 TOI for Sun High End Storage(USP-V) Orange Business Services
Server Storage
Veritas VM
Solaris VM
Logical VM
Universal VM
Introduction of RAID System 2 2
1. RAID0 = "Striped set without parity" or "Striping". Provides improved performance and additional storage but no redundancy or fault tolerance.
2. RAID1 = 'Mirrored set without parity' or 'Mirroring'. Provides fault tolerance from disk errors and failure of all but one of the drives.
3. RAID2 = Hamming code parity. Disks are synchronized and striped in very small stripes, often in single bytes/words.
4. RAID3 = Striped set with dedicated parity or bit interleaved parity or byte level parity. This mechanism provides fault tolerance similar to RAID 5. However, because the strip across the disks is a lot smaller than a filesystem block, reads and writes to the array perform like a single drive with a high linear write performance.
5. RAID4 = Block level parity. Identical to RAID 3, but does block-level striping instead of byte-level striping. In this setup, files can be distributed between multiple disks
6. RAID5 = Striped set with distributed parity or interleave parity. Distributed parity
5 TOI for Sun High End Storage(USP-V) Orange Business Services
6. RAID5 = Striped set with distributed parity or interleave parity. Distributed parity
requires all drives but one to be present to operate; drive failure requires replacement, but the array is not destroyed by a single drive failure.
7. RAID6 = Striped set with dual distributed parity. Provides fault tolerance from two drive failures; array continues to operate with up to two failed drives. This makes larger
RAID groups more practical, especially for high availability systems.
Introduction of RAID System 2 3
RAID
RAID 0
RAID 1
RAID 3
RAID 4
RAID 2
Exemple of RAID5
6 TOI for Sun High End Storage(USP-V) Orange Business Services
RAID 5
RAID 6
RAID 0+1
RAID 1+0
A
B
B
C
C
D
D
A
Exemple of RAID5
Parity Disk10GB 10GB 10GB 10GB
30GB Usable space
Storage Product @ Sun Microsystems3 1
� Entry level Storage(EOL):
� Mid level Storage:– STK-25xx– STK-35xx
– STK 61xx
High End
Mid level
� High End Storage– SE-9985V– SE-9990V
7 TOI for Sun High End Storage(USP-V) Orange Business Services
� Entry level Storage(EOL):– S1– D1000/A1000
– D240
Entry level
Storage Product @ Hitachi Data System (HDS)3 2
� Simple Modular Storage(SMS):
� Mid level Storage:– WMS-100– AMS-100/200/500
– AMS-2000/2100/2300/2500
High End
Mid level
� High End Storage– Lighting 99xx– USP-V
– USP-VM
8 TOI for Sun High End Storage(USP-V) Orange Business Services
� Simple Modular Storage(SMS):– SMS 100
Entry level
Naming Convention of Enterprise Storage3
Manufacture
Hitachi
Reseller
Sun
OEM
3
Lighting-9970Lighting-9990
Hitachi
SE-9970SE-9980
Sun
XP-512/102XP-1200/1000
HP
9 TOI for Sun High End Storage(USP-V) Orange Business Services
USP-V Storage Physical Diagram4
USP-V can have Max 64x18=1152 Physical DisksUSP-VM can have Max 60x4=240 Physical Disks
1
10 TOI for Sun High End Storage(USP-V) Orange Business Services
USP-V Storage SAN Logical Diagram 4
DKA = Disk Adaptor CHA = Chanel Adaptor
3
CHA
USP-V
SAN Switch
SAN Switch
Win
Solaris
HPUX
DKA
12 TOI for Sun High End Storage(USP-V) Orange Business Services
HPUX
RCU Target
RCU Initiator
USP-V Storage SAN Logical Diagram 4 DKA = Disk Adaptor CHA = Chanel Adaptor 4
Win Solaris HPUX
SAN Switch
SAN Switch
CHA
USP-V
DKA
13 TOI for Sun High End Storage(USP-V) Orange Business Services
RCU Target
RCU Initiator
EMC SAN Storage Connectivity at AY-DC4 5
14 TOI for Sun High End Storage(USP-V) Orange Business Services
USP-V SAN Storage Logical Connectivity4 6
15 TOI for Sun High End Storage(USP-V) Orange Business Services
USP-V Storage Architecture4
Host
8
CHA
SM
CSW
DKA
Cash
17 TOI for Sun High End Storage(USP-V) Orange Business Services
USP-V Software Service5
� Hitachi Cache Residency Manager
� Hitachi Dynamic Link Manager Software
Hitachi Universal Volume Manager Software� Hitachi Universal Volume Manager Software
� Hitachi Virtual Partition Manager Software
� Hitachi Dynamic Provisioning Software
� Hitachi Replication
- TrueCopy/UR
- Shadow Image
- Copy-On-Write
18 TOI for Sun High End Storage(USP-V) Orange Business Services
- Copy-On-Write
Storage Navigator overview (Login Window)6 1
19 TOI for Sun High End Storage(USP-V) Orange Business Services
Storage Navigator overview (Main Window)6 1
20 TOI for Sun High End Storage(USP-V) Orange Business Services
Storage Navigator overview (LUN manager)6 2
21 TOI for Sun High End Storage(USP-V) Orange Business Services
Storage Navigator overview (Host Group)6 3
22 TOI for Sun High End Storage(USP-V) Orange Business Services
Support Data7
� Explorer (for Solaris/Linux OS)
� Winget-log(for truecopy)
Autodump� Autodump
� Trace-log.
� Audit-log.
23 TOI for Sun High End Storage(USP-V) Orange Business Services