for sale - sparesinmotion.com · for sale. 2 content general specifications 3 electrical...
TRANSCRIPT
1
1 x Vestas V66 - 1.65 MW – 4 x V66 - 1.75 MWHub heights 78 meters – Date of commissioning December 2003 - Site: Waardtocht
5 turbines available
For Sale
2
Content
General specifications 3
Electrical Specification 9
Site Overview 11
Vestas requirements - Terrain & climatic conditions 11
Operation & Maintenance 12
Contact 12
Disclaimer 12
3
General specificationsPower curve data 1.65
V10 (m/s) 1.225 1.06 1.09 1.12 1.15 1.18 1.21 1.24 1.27 4 13,5 6,8 8,0 9,2 10,5 11,7 12,9 14,1 15,3 5 80,8 65,1 68,0 70,8 73,7 76,5 79,4 82,3 85,1 6 169 141 146 151 157 162 167 172 177 7 289 244 253 261 269 277 285 293 301 8 448 381 393 406 418 430 442 454 466 9 644 549 567 584 601 618 635 652 669 10 858 734 757 779 802 824 847 869 892 11 1069 917 945 973 1000 1028 1055 1083 1110 12 1263 1089 1120 1153 1185 1216 1248 1280 1309 13 1431 1247 1283 1319 1352 1384 1415 1451 1472 14 1552 1393 1428 1463 1492 1516 1540 1569 1580 15 1617 1514 1540 1567 1586 1599 1611 1627 1631 16 1642 1594 1608 1622 1631 1636 1640 1645 1646 17 1649 1633 1638 1643 1646 1647 1648 1649 1650 18 1650 1646 1647 1649 1649 1650 1650 1650 1650 19-->25 1650 1650 1650 1650 1650 1650 1650 1650 1650
Power curve 1.65
2000
1500
500
0
1000
0 5 10 15 20 25
Pow
er (k
W)
Windspeed (m/s)
V66 - 1.65 MWAir Density 1.225 kg/m3
4
Power curve data 1.75
V66-1.75 MW, 106.5 dB(A)
V10 (m/s) 1.225 1.060 1.090 1.120 1.150 1.180 1.210 1.240 1.270 4 33,3 25,4 26,9 28,3 29,7 31,1 32,6 34,0 35,4 5 93,3 77,9 80,8 83,7 86,6 89,5 92,4 95,3 98,2 6 178 150 155 160 165 170 175 180 185 7 294 250 258 266 274 282 290 298 306 8 452 385 397 409 421 433 446 458 470 9 655 560 577 595 612 629 647 664 681 10 900 771 795 818 842 865 889 912 936 11 1167 1004 1034 1064 1093 1123 1152 1182 1211 12 1418 1235 1270 1306 1338 1370 1402 1433 1465 13 1603 1442 1478 1515 1540 1565 1590 1615 1640 14 1702 1600 1628 1657 1670 1683 1695 1708 1721 15 1739 1694 1709 1724 1728 1732 1736 1741 1745 16 1748 1735 1740 1745 1746 1747 1748 1748 1749 17 1750 1747 1748 1749 1749 1750 1750 1750 1750 18 1750 1750 1750 1750 1750 1750 1750 1750 1750 19 1750 1750 1750 1750 1750 1750 1750 1750 1750 20->25 1750 1750 1750 1750 1750 1750 1750 1750 1750
Power curve 1.75
2000
1800
1600
1400
800
600
400
200
0
1200
1000
0 5 10 15 20 25
Pow
er (k
W)
Windspeed (m/s)
V66 - 1.75 MWAir Density 1.225 kg/m3
5
C = 1,5
Wind Turbine 5 m/s 6 m/s 7 m/s 8 m/s 9 m/s 10 m/sV66-1,75 MW, 102 dB(A) 2.093 3.111 4.111 5.013 5.771 6.370V66-1,75 MW, 102,5 dB(A) 2.115 3.146 4.156 5.065 5.827 6.428V66-1,75 MW, 104 dB(A) 2.158 3.212 4.241 5.163 5.932 6,536V66-1,75 MW, 106,5 dB(A) 2.175 3.239 4.276 5.202 5.974 6.580
C = 2
Wind Turbine 5 m/s 6 m/s 7 m/s 8 m/s 9 m/s 10 m/sV66-1,75 MW, 102 dB(A) 1.653 2.718 3.900 5.086 6.188 7.146V66-1,75 MW, 102,5 dB(A) 1.666 2.748 3.948 5.148 6.259 7.221V66-1,75 MW, 104 dB(A) 1.692 2.807 4.040 5.266 6.393 7.362V66-1,75 MW, 106,5 dB(A) 1.702 2.831 4.078 5.314 6.447 7.419
C = 2,5
Wind Turbine 5 m/s 6 m/s 7 m/s 8 m/s 9 m/s 10 m/sV66-1,75 MW, 102 dB(A) 1.384 2.410 3.643 4.964 6.265 7.461V66-1,75 MW, 102,5 dB(A) 1.389 2.431 3.687 5.031 6.348 7.553V66-1,75 MW, 104 dB(A) 1.401 2.473 3.774 5.160 6.506 7.725 V66-1,75 MW, 106,5 dB(A) 1.406 2.491 3.810 5.213 6.571 7.795
Yield prognosis data 1.75
V66-1.65 MW Mean Wind Speed (m/s) (C=2) Annual Production (kWh) 5 1.586.000 6 2.638.000 7 3.789.000 8 4.928.000 9 5.977.000 10 6.881.000
Yield prognosis data 1.65
6
RotorDiameter: 66 m Swept area: 3421 m2Rotational speed rotor: 15.4 - 19.8 RPM (1.65) 10.5 – 24.4 RPM (1.75)Rotational direction: Clockwise (front view) Orientation: Upwind Tilt: 6° Number of blades: 3 Aerodynamic brakes: Full feathering
BladesAir foils: NACA63.600+FFA-W3 Length: 32 m Chord (Width) (blade root/blade tip): 2.8 m /0.4 m Twist (blade root/blade tip): 15°/0° Weight: approx. 3,800 kg/pcs.
Tower (Steel) & WeightsTop diameter tower: 2.3 m Bottom diameter tower: 4.0 m 4-parted, modular tower: 78 mTower: 146 - 190 tonnes Nacelle: 57 tonnes Rotor: 23 tonnes Total (tower): 226 - 270 tonnes
Basic data V66
Turbine specific information
Type Controller Commissioning Availability 2014Turbine 1 V66-1650KW-2G VPM 3500 2003 99.36%Turbine 2 V66-1750KW-2G VPM 3500 2003 87.83%Turbine 3 V66-1750KW-2G VPM 3500 2003 98.43%Turbine 4 V66-1750KW-2G VPM 3500 2003 95.76%Turbine 5 V66-1750KW-2G VPM 3500 2003 98.13%
7
Production analysis
The above figure shows the concurrent monthly production data and monthly Windex Windunie “Noord Holland Noord” data over a number of years per turbine. The Windex from Windunie is a well-known Windex in the Netherlands. The reference period of this Windex is from 1996 until 2005.
The above figure shows the monthly production data and the monthly Windex Windunie “Noord Holland Noord” data in a scatter plot. The trend line is the closest match between all points and the R2 represents the correlation factor. If R2 is 1 the data shows a perfect match and from 0,8 it is considered as a good correlation.
8
Mai
n co
mpo
nent
s
Turb
ine
ID
1504
1 (T
1)
1597
4 (T
2)
1597
5 (T
3)
1597
6 (T
4)
1597
7 (T
5)
Com
miss
ioni
ng d
ate
Dec-
03
Dec-
03
Dec-
03
Dec-
03
Dec-
03
Full o
pera
ting
win
d ho
urs
1760
,7
2038
,0
2278
,4
2174
,2
2203
,0
3 ye
ars a
go
Full o
pera
ting
win
d ho
urs
2030
,7
2189
,0
2410
,8
2172
,9
2334
,6
2 ye
ars a
go
Full o
pera
ting
win
d ho
urs
2046
,9
1966
,7
2257
,4
2147
,4
2210
,6
1 ye
ar a
go
Gear
box
bran
d &
type
W
iner
gy P
EAB4
395
Win
ergy
PEA
B439
5 W
iner
gy P
EAB4
395
Win
ergy
PEA
B439
5 Ha
nsen
EH8
01L2
1
Gear
box
exch
ange
dat
e Ja
n-12
Ja
n-07
M
ay-0
6 M
ay-0
6 Ap
r-08
Gene
rato
r bra
nd &
type
W
eier
DAS
G 45
0W
Wei
er D
VSG
500/
4M S
P AB
B AM
K 50
0L4A
BAT
YL
ABB
AMK
500L
4A B
ATYL
W
eier
DVS
G 50
0/4M
SP
Tota
l pro
duct
ion
gene
rato
r (kW
h)
20.9
78.8
85
40.8
68.8
42
42.8
59.4
16
14.2
31.5
90
42.2
09.2
19
(disp
lay
valu
e)
Tran
sfor
mer
type
& b
rand
Si
emen
s GEA
FOL
4GB6
2492
-9DC
Sc
hnei
der E
lect
ric Tr
ihal
AB
B Re
siblo
c SG
B DT
THIL
160
0/10
AB
B Re
siblo
c
9
Electrical SpecificationGenerator 1.65
The Vestas V66 1.65 has 2 generators, in these specific wind turbines the small generator (300kW) is disconnected, this does not influence the production. Primary Generator Secondary generator 50 Hz 50 Hz Type: Asynchronous, 4 poles 4 poles Rated power: 1.65 MW/(1.65 MW) 300 kW/(300 kW) Voltage: 690 VAC 690 VAC Frequency: 50 Hz/(60Hz) 50 Hz/(60Hz) No. of poles: 4 4 Class of insulation: F F Class of protection: IP54 IP54 Nominal speed: 1575 RPM/(1890 RPM) 1515/(1819 RPM) Rated current: 1517 A/(1485 A) 296A/(295 A) Power factor: 0.91/(0.93) 0.85 Power factor correction: 600 kVAr 150 kVAr Resulting power factor: 0.98 0.99 Resulting current: 1409A 253A
Generator 1.75
Generator with VCS 50 Hz/60HzRated power: 1.75 MWType: Asynchronous with wound rotor. slip rings and VCSVoltage: 690 VACFrequency: 50 Hz / 60HzNo. of poles: 4Class of protection: IP54Rated speed: 1680 / 2016 RPMRated power factor. default: 1.0Power factor range: 0.98CAP - 0.95IND (option).
10
Transformer 1.65
50 Hz/(60 Hz) Type: Cast resin Rated Power: 1670 kVA Vector group: Dyn High voltage: 6 - 33 kV (36 kV (Um) equipment voltage) HV - Tappings: ±2 x 2.5% Impedance voltage: 6% Low voltage: 690V
Transformer 1.75
Type: Cast resinRated Power: 1850 kVAHigh voltage: 6 - 33 kV (36 kV (Um) equipment voltage)Frequency: 50 Hz / (60 Hz)Vector group: DynHV – Tappings: ±2 x 2.5%Low voltage: 690 VPower at 690 V: 1686 kVALow voltage: 480 VPower at 480 V: 180 kW
Grid
The turbines are connected to a high-voltage grid at 10 kV. The cable connection is made in the bottom of the tower.
11
Site Overview
Site is similar to picture above (picture of neighbouring park). Drawing available upon request.
Vestas Requiremants - Terrain & Climatic ConditionsIf the terrain within a 100 m radius of the turbine has a slope of more than 10° (18%), particular considerations have to be taken.
The turbine is designed for ambient temperature ranging from -20°C to +40°C. Outside these temperatures the turbine stops, and special considerations must be taken.
With regards to the wind conditions the turbine has been designed in accordance with IEC 1400-1 class I, DS472 (Teknisk Grundlag), Germanischer Lloyd of 1993, class II and NEN 6996/2, Den Helder.
The turbines can be placed in wind farms with a distance of min. 5 rotor diameters (330 m) between turbines. If the turbines are placed in one row, along predominant wind direction, the distance between the turbines must as a min. be 4 rotor diameters (264 m).
12
Operation & MaintenanceAll assets are maintained according to Vattenfall standards, following the original maintenance manual, by the Original Equipment Manufacturer or a third-party contractor. Maintenance manual, maintenance history are available during site visit. As-built documentation is available upon request.
ContactFor more information, as-built documentation (Dutch), pictures or other information please contact:Sven Kamphues Mark Pruissen Hidde SeidelCommercial management Project management Operational management+31 6 11382886 +31 6 46360964 +31 6 50126257
Email: [email protected]
N.V. Nuon Energy (part of Vattenfall)Address: PO-Box 41920, 1009 DC Amsterdam, the Netherlands Visit: Hoekenrode 8, 1102 BR Amsterdam Zuidoost, the Netherlands
DisclaimerThe information contained in this catalogue has been derived from Vattenfall operational statistics as well as public sources. Although comprised with the due care, the purchaser uses and interprets the information contained herein at its own risk. Vattenfall does not warrant the accuracy nor the correctness of the information contained in this catalogue and assumes or undertakes no liability for any loss or damage suffered as a result of the use, misuse or reliance on the information and content in this catalogue.