for lease - 3 industrial buildings ranging from ±23,546 - … · 2019-05-22 · for lease 3...

7
CHRIS LANE, CCIM +1 702 836 3728 [email protected] DAN DOHERTY +1 702 836 3707 [email protected] JERRY DOTY +1 702 836 3735 [email protected] PAUL SWEETLAND +1 702 836 3750 [email protected] For More Information, Please Contact: A DEVELOPMENT BY: SWC DIABLO DRIVE AND EDMOND STREET FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF NEVADA STATE INDUSTRIAL PARK

Upload: others

Post on 31-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

CHRIS LANE, CCIM+1 702 836 [email protected]

DAN DOHERTY+1 702 836 [email protected]

JERRY DOTY+1 702 836 [email protected]

PAUL SWEETLAND+1 702 836 [email protected]

For More Information, Please Contact: A DEVELOPMENT BY:

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

NEVADA STATE INDUSTRIAL PARK

Page 2: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

CHRIS LANE, CCIM+1 702 836 [email protected]

DAN DOHERTY+1 702 836 [email protected]

JERRY DOTY+1 702 836 [email protected]

PAUL SWEETLAND+1 702 836 [email protected]

For More Information, Please Contact: A DEVELOPMENT BY:

UPRR

15

15

15

15

15

93

93

93

95

93

95

95

95

93

93

93

95

95

95

215

215

215

215

215

515

515

515

502

593

564

582

160

604

604

604

589

159

599

574

573

147147

147

147

167

166

595

595 607

607

146

582

612

157

15

GRAND TETON DRIVE

ELKHORN ROAD

LOSSE ROAD

W CENTENNIAL PARKWAY

ANN ROADW ANN ROAD

SIMMONS STREET

N DECATUR BLVD

CRAIG ROAD

E DESERT INN ROAD

W CHARLESTON BLVD E CHARLESTON BLVD

W SAHARA AVE

W DESERT INN ROAD

FLAMINGO ROAD FLAMINGO ROADBUFFALO DRIVE

S RAINBOW BLVD

S DURANGO DRIVE

FORT APACHE ROAD

TROPICANA AVENUE TROPICANA AVENUE

BOULDER HWY

STEWART AVENUE

E BONANZA ROAD

E OWENS AVENUE

W LONE MOUNTAIN ROAD

N JONES BLVD

W ALEXANDER ROAD

W CHEYENNE AVENUE

S DECATUR BLVDN DECATUR BLVD

N JONES BLVDN JONES BLVD

E SAHARA AVE

S PECOS ROAD

S EASTERN AVENUE

BLUE DIAMOND ROAD

W WARM SPRINGS ROAD

S RAINBOW BLVD

GOMER ROAD

S JONES BLVD

W SUNSET ROAD

W RUSSELL ROAD

N RANCHO DR

SOUTH LAS VEGAS BLVD

BERMUDA RD

MARTIN LUTHER KING JR BLVD

N 5TH STREET

N LAS V

EGAS B

LVDN EASTERN AVE

W WASHINGTON DRIVE

E LAKE MEAD BLVDW LAKE MEAD BLVD

TOWN CENTER DRIVE

W HORIZ

ON RIDGE PKWY

N STEPHANIE STREET

LAMB BLVD

HUALAPAI WAY

RACETRACK ROAD

COLLEGE DR

EQUESTRIAN DR

E PARADISE HILLS DR

RICHARDSON DRIVE

BURKHOLDER BLVD

GREEN VALLEY PARKWAY

MARYLAND PARKWAY

E RUSSELL ROAD

WARM SPRINGS ROAD

MARYLAND PARKWAY

ALTA DRIVE

VEGAS DRIVE

SMOKE RANCH ROAD

PECOS ROAD

S HOLLYWOOD BLVD

N DURANGO DRIVE

CAMINO AL NORTE

WINDMILL LN

UNION PACIFIC RR

KYLE CANYO

N RD

S BUFFALO DRIVE

E WASHINGTON AVE

N HOLLYWOOD BLVD

N LOS FELIIZ STVEGAS VALLEY DRIVE

FREMONT ST

THE STR

IP

S SANDHILL ROAD

E SUNSET ROAD

WINDMILL LANE

DEAN MARTIN DR

W SILVERADO RANCH BLVD

W CACTUS AVE

SOUTHERN HIGHLANDS PARKWAY

SHINNECOCK HILLS AVE

MOUNTAINS EDGE PKWY

W CACTUS AVE

S FORT APACHE RD

W WIGWAM AVE

VOLUNTEER BLVD

ANTHEM PARKWAY

SEVEN HILLS DR

AMERICAN PACIFIC DR

EASTGATE RD

BROADBENT BLVD

MISSION DR

GREENWAY RD

W PACIFIC AVE

S WATER ST

E VAN WAGENEN ST

FOOTHILLS DR

APPALOOSA RD

S MAGIC WAY

CENTER ST

PABCO ROAD

N ARROYO GRANDE BLVD

VALLE VERDE DR

E PEBBLE ROAD

SPRING MOUNTAIN RD

PARADISE RD

E ST LOUIS AVE

N BRUCE ST

E Evans Ave

Belmont St

E Carey Ave

S LAMB BLVD

N PECOS ROAD

WASHBURN RD

N TENAYA WAY

SEVERENCE LANE

DEER SPRINGS WAY

DESERT FOOTHILLS DR

W ARBY AVE

PAIUTE

WAY

HACIENDA AVE

St Rose

Parkw

ay

UNION

PACIFIC

RR

E LAKE MEAD PA

RKWAY

WESTCLIFF DRIVE

N RAINBOW BLVD

LAKE LAS VEGAS PKWY

SUMMERLIN PARKWAY

INDUSTRIAL

ROA

D

BUFFALO DRIVE

CLIFF SHADOWS PARKW

AY

VALLEY VIEW ROAD

RAMPART

E PATRICK ROAD

GIBSON

NELLIS AFB

NORTH LAS VEGASAIRPORT

MC CARRANINT’L AIRPORT

LAKELAS VEGAS

LOSPRADOS

SOUTHERNHIGHLANDS

SUNSETPARK

LAS VEGASMUNICIPAL

SPANISH TRAIL

RHODESRANCH

NEVADATRAILS

CORONADORANCH

DURANGOHILLS

HENDERSON EXECUTIVEAIRPORT

LAS VEGAS

EASTLAS VEGAS

GREENVALLEY

SUMMERLIN

HENDERSON

NORTHLAS VEGAS

SILVERADORANCH

DEL WEBB’SANTHEM

SOUTHFORK

SUNRIDGE WESTCANYON

DEL WEBBSUN CITY MACDONALD RANCH

RAILROADPASS

MACDONALDHIGHLANDS

WHITNEYRANCH

UNLV

BOULEVARDMALL

SPRINGVALLEY

SUNRISECOLONY

THE LAKES

PECCOLERANCH

SUN CITY LAS VEGASDESERTSHORES

RANCHOALTA MIRA

RANCHODEL NORTE

EL DORADO

IRONMOUNTAIN

RANCH

PROVIDENCE

SILVERSTONE

LAS VEGASMOTOR SPEEDWAY

APEX INDUSTRIAL PARK

LAS VEGASPAIUTE GOLF RESORT

MOUNTAIN’SEDGE

ALIANTE

SHADOWCREEK

SUNRISEVISTA

DESERT PINES

DESERTROSE

ROYALLINKS

STALLIONMOUNTAIN

REFLECTIONBAY

THEFALLS

TUSCANY

BLACKMOUNTAIN

DRAGON RIDGEDRAGON RIDGE

ANTHEM

REVERE

RIO SECCO

WILDHORSE

LEGACY

BALIHAI

WYNN

LAS VEGASCC

PAINTED DESERT

EAGLECREST

TPC ATCANYONS

TPC ATSUMMERLIN

HIGHLANDFALLS

PALMVALLEY

REDROCK

BADLANDS

BEAR’SBEST

ANGELPARK

CANYONGATE

SIENA

INSPIRADA

KYLECANYONGATEWAY

SPRINGMOUNTAIN

RANCH

ELKHORNSPRINGS

SEVEN HILLS

LOCATION±2 Miles West of the Las Vegas Strip and the new Raiders Stadium

LAND±11.47 Acres M-D Zoned, Light Industrial

BUILDING3 Buildings AvailableConcrete Tilt Up Design±23,546 SF to ±101,308 SFClear Height: 28’ to 32’ Minimum

ELECTRICITY BROADBANDNATURAL GAS

Page 3: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

CHRIS LANE, CCIM+1 702 836 [email protected]

DAN DOHERTY+1 702 836 [email protected]

JERRY DOTY+1 702 836 [email protected]

PAUL SWEETLAND+1 702 836 [email protected]

For More Information, Please Contact: A DEVELOPMENT BY:

EDMOND STREET

LAS VEGAS “STRIP”

BUILDING A±101,308 SF

BUILDING B±71,093 SF

BUILDING C±23,546 SF

Page 4: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

CHRIS LANE, CCIM+1 702 836 [email protected]

DAN DOHERTY+1 702 836 [email protected]

JERRY DOTY+1 702 836 [email protected]

PAUL SWEETLAND+1 702 836 [email protected]

For More Information, Please Contact: A DEVELOPMENT BY:

2.7 MILES TO STRIP

JONE

S BO

ULEV

ARD

DECA

TUR

BOUL

EVAR

D

LAS

VEGA

S BO

ULEV

ARD

RUSSELL ROAD

TROPICANA AVENUE

SUNSET ROAD

2.5 MILES TO STRIP

1.7 MILES TO I-15

1.5

MIL

ES T

O 2

15

15

15

215

215

BUILDING A

BUILDING B

BUILDING C

RAIN

BOW

BOU

LEVA

RD

Page 5: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

A

B

C

D

E

F

1 2 3 4 5 6 6.1 7 8 9 10 11

4

500'-0"

50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0"

207'

-0"

50'-0

"50

'-0"

50'-0

"50

'-0"

7'-0

"

SUITE 10025,632 S.F.

SUITE 12025,168 S.F.

SUITE 14025,339 S.F.

SUITE 16024,765 S.F.

BUILDING101,308 S.F.

PUMP324 S.F.

RISER80 S.F.

TRUCK DOCKS TRUCK DOCKSGRADE LEVELGRADE LEVEL GRADE LEVEL

CO

NT

RA

CT

OR

:T

hese

pla

ns a

re p

repa

red

and

subm

itted

by

the

cont

ract

oras

an

exem

ptio

n to

NR

S 62

3.33

0 fo

r w

ork

unde

r co

ntra

ctor

licen

se c

ateg

ory

auth

oriz

ed u

nder

NR

S 62

4.

LM

CO

NST

RU

CT

ION

CO

.(C

ompa

ny N

ame)

# 0

0425

96A

(Con

trac

tors

Lic

ense

#)

MIK

E B

RO

WN

(Pla

ns P

repa

red

By)

(Sig

natu

re)

Cop

yrig

ht

©M

ater

ial .

All

right

s re

serv

ed

None

of t

he m

ater

ials

prov

ided

on

this

docu

men

t may

be

used

, rep

rodu

ced

ortra

nsm

itted,

in w

hole

or in

par

t, in

any f

orm

or b

y any

mea

ns, e

lectro

nic o

r mec

hanic

al,inc

luding

pho

toco

pying

, rec

ordin

g or

the

use

of a

ny in

form

ation

stor

age

and

retri

eval

syste

m wi

thout

the pe

rmiss

ion in

writi

ng fr

om th

e pub

lishe

r. To

requ

est s

uch p

ermi

ssion

and

for f

utur

e in

quire

s, c

onta

ct L

M C

onst

ruct

ion

Co. L

LC. F

urth

erm

ore,

the

work

s of

auth

orsh

ip c

onta

ined

in th

ese

plan

s, in

cludi

ng b

ut n

ot lim

ited

to a

ll des

ign,

text

and

imag

es, a

re o

wned

, exc

ept a

s ot

herw

ise s

tate

d, b

y L

M C

onst

ruct

ion

Co. L

LC.

or o

ne o

f its

affi

liate

s an

d m

ay n

ot b

e co

pied

, rep

rodu

ced,

tran

smitt

ed, d

ispla

yed,

perfo

rmed

, dis

tribu

ted,

rent

ed, s

ub li

cens

ed, a

ltere

d, s

tore

d fo

r sub

sequ

ent

use

in w

hole

or i

n pa

rt in

any

man

ner w

ithou

t the

exp

ress

ed w

ritte

n co

nsen

t of

L M

C

on

stru

ctio

n C

o. L

LC

.

USE

OF

THES

E DR

AWIN

GS

IS L

IMIT

ED T

O A

SPE

CIFI

ED P

ROJE

CT F

OR

PERS

ONS

NAM

ED H

EREO

N AN

D FO

R TH

E CO

NSTR

UCTI

ON O

F ON

E PR

OJEC

T.

CO

NST

RU

CTI

ON

CO

.50

75 C

AM

ER

ON

SU

ITE

#H

LAS

VE

GA

S, N

EV

AD

A 8

9118

(702

) 262

-603

2, F

AX

(702

) 262

-615

0N

EV

AD

A L

IC. #

004

2596

A

PRELIMINARY

DRAWN BY:CHECKED BY:JOB NUMBER:DATE:

DESCRIPTION DATE

P3318

PRO

POSE

D O

FFIC

E/W

AR

EHO

USE

LAS

VEG

AS,

NV

891

18SW

CO

RN

ER O

F D

IAB

LO &

ED

MO

ND

S

5-3-18

A1.1A

FLO

OR

PL

AN

-BU

ILD

ING

"A

"

SCALE:1 FLOOR PLAN-BUILDING "A"1" = 20'-0"

FLOOR PLAN - BUILDING A

A-2±51,124 SF

A-1±50,184 SF

CONSTRUCTION: The structure is to be a rear loaded concrete tilt up building

DEMISING WALL: Full height concrete demising wall ±8” inches thick with knockout panels

PAVING: All Auto paving 2” AC over 6” Type II, All Truck paving 3” AC over 6” Type II or as recommended by the Project’s soils engineer

SLAB ON GRADE: Slab on grade to be nominal 6” thick 4,500 psi material, reinforced with #4 rebar at 18” OCEW

DOCK APRON: 60’ concrete dock apron out from the building wall

COLUMN SPACING: Approximately 50’ x 50’ minimum typical

STAIRS: Dock stairs as required by code

ROOFING:Single-ply, TPO roof, with hybrid wood deck with steel truss, 10 year manufacturer’s warranty

INSULATION:Two layers of ridgid board insulation to reach R-30 with cap sheet at underside of roof structure

DOCK DOORS:A-1: Eleven (11) 9-6”’ x 10’ dock high loading doors A-2: Ten (10) of same

DOCK EQUIPMENT: Dock bumpers installed at each dock door

GRADE DOORS:A-1: Four (4) 14’ x 16’ grade level loading door.A-2: Two (2) of same. The grade door shall be a 24 gauge sectional vertical lift, manually operated and non-insulated door.

SKYLIGHTS:286-degree fusible link, single dome, Laine Air or equal, to exceed code minimum. With burglar bars, ±2% of the roof area

FIRE PROTECTION:ESFR fire-sprinkler system designed to meet current fire code requirements

ELECTRICAL SERVICE: The Premises will feature 277/480 volt, 3-phase, 4-wire, 1,200 amp service. (A-1 and A-2 each have 1,200A).2,400 A total for both buildings. Emergency lighting at man door exits

CLEAR HEIGHT:The clear height for the warehouse area of the building will be ±32’ min at the first column line past the speed bay

WAREHOUSE LIGHTING: TBD

WAREHOUSE COOLING: TBD

*All improvements/specifications subject to changes

Lease Rate: $0.58-$0.65

GRADE LEVEL LOADING DOOR

DOCK DOOR LOADING DOOR

Page 6: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

A

1 2 3 4 5 6 7 8 9

B

C

C

C

C

201'

-6"

400'-8"

36'-9

"36

'-9"

54'-0

"36

'-8"

37'-4

"

54'-0" 50'-0" 47'-6" 50'-0" 50'-9" 50'-0" 50'-0" 48'-5"

BUILDING71,093 S.F.

SUITE 10041,039 S.F.

SUITE 15029,548 S.F.

RISER90 S.F.

PUMP416 S.F.

TRUCK DOCKS TRUCK DOCKSGRADE LEVEL GRADE LEVELGRADE LEVEL

CO

NT

RA

CT

OR

:T

hese

pla

ns a

re p

repa

red

and

subm

itted

by

the

cont

ract

oras

an

exem

ptio

n to

NR

S 62

3.33

0 fo

r w

ork

unde

r co

ntra

ctor

licen

se c

ateg

ory

auth

oriz

ed u

nder

NR

S 62

4.

LM

CO

NST

RU

CT

ION

CO

.(C

ompa

ny N

ame)

# 0

0425

96A

(Con

trac

tors

Lic

ense

#)

MIK

E B

RO

WN

(Pla

ns P

repa

red

By)

(Sig

natu

re)

Cop

yrig

ht

©M

ater

ial .

All

right

s re

serv

ed

None

of t

he m

ater

ials

prov

ided

on

this

docu

men

t may

be

used

, rep

rodu

ced

ortra

nsm

itted,

in w

hole

or in

par

t, in

any f

orm

or b

y any

mea

ns, e

lectro

nic o

r mec

hanic

al,inc

luding

pho

toco

pying

, rec

ordin

g or

the

use

of a

ny in

form

ation

stor

age

and

retri

eval

syste

m wi

thout

the pe

rmiss

ion in

writi

ng fr

om th

e pub

lishe

r. To

requ

est s

uch p

ermi

ssion

and

for f

utur

e in

quire

s, c

onta

ct L

M C

onst

ruct

ion

Co. L

LC. F

urth

erm

ore,

the

work

s of

auth

orsh

ip c

onta

ined

in th

ese

plan

s, in

cludi

ng b

ut n

ot lim

ited

to a

ll des

ign,

text

and

imag

es, a

re o

wned

, exc

ept a

s ot

herw

ise s

tate

d, b

y L

M C

onst

ruct

ion

Co. L

LC.

or o

ne o

f its

affi

liate

s an

d m

ay n

ot b

e co

pied

, rep

rodu

ced,

tran

smitt

ed, d

ispla

yed,

perfo

rmed

, dis

tribu

ted,

rent

ed, s

ub li

cens

ed, a

ltere

d, s

tore

d fo

r sub

sequ

ent

use

in w

hole

or i

n pa

rt in

any

man

ner w

ithou

t the

exp

ress

ed w

ritte

n co

nsen

t of

L M

C

onstructio

n C

o. LLC

.

USE

OF

THES

E DR

AWIN

GS

IS L

IMIT

ED T

O A

SPE

CIFI

ED P

ROJE

CT F

OR

PERS

ONS

NAM

ED H

EREO

N AN

D FO

R TH

E CO

NSTR

UCTI

ON O

F ON

E PR

OJEC

T.

CO

NST

RU

CTI

ON

CO

.50

75 C

AM

ER

ON

SU

ITE

#H

LAS

VE

GA

S, N

EV

AD

A 8

9118

(702

) 262

-603

2, F

AX

(702

) 262

-615

0N

EV

AD

A L

IC. #

004

2596

A

PRELIMINARY

DRAWN BY:CHECKED BY:JOB NUMBER:DATE:

DESCRIPTION DATE

P3318

PRO

POSE

D O

FFIC

E/W

AR

EHO

USE

LAS

VEG

AS,

NV

891

18SW

CO

RN

ER O

F D

IAB

LO &

ED

MO

ND

S

A1.1B

FLO

OR

PL

AN

-BU

ILD

ING

"B

"

SCALE:1 FLOOR PLAN-BUILDING "B"1" =20'-0"

5-4-18

B-2±41,455 SF

B-1±29,638 SF

CONSTRUCTION: The structure is to be a rear loaded concrete tilt up building

DEMISING WALL: Full height concrete demising wall ±8” inches thick with knockout panels

PAVING:All Auto paving 2” AC over 6” Type II, All Truck paving 3” AC over 6” Type II or as recommended by the Project’s soils engineer

SLAB ON GRADE:Slab on grade to be nominal 6” thick 4,500 psi material, reinforced with #4 rebar at 18” OCTW

DOCK APRON: 60’ concrete dock apron out from the building wall

COLUMN SPACING: Varies throughout

STAIRS: Dock stairs as required by code

ROOFING:Single-ply, TPO roof, with hybrid wood deck with metal truss, 10 year manufacturer’s warranty

INSULATION:Two layers of ridgid board insulation to reach R-30 with cap sheet at underside of roof structure

DOCK DOORS: B-1 & B-2 Each building will have Six (6) 9’-6” x 10’ dock high loading doors

DOCK EQUIPMENT: Dock bumpers installed at each dock door

GRADE DOORS:B-2: Four (4) 14’ x 16’ grade level loading doors. B-1: Two (2) of same. The grade door shall be a 24 gauge sectional vertical lift, manually operated and non-insulated door

SKYLIGHTS:286-degree fusible link, single dome, Laine Air or equal, to exceed code minimum. ±2% of the roof area

FIRE PROTECTION:ESFR fire-sprinkler system designed to meet current fire

ELECTRICAL SERVICE:The Premises will feature 277/480 volt, 3-phase, 4-wire, 800 amp service for B-1 and B-2 (1,600 A total for both buildings). Emergency lighting at man door exits

CLEAR HEIGHT:The clear height for the warehouse area of the building will be ±30’ min at the first column line past the speed bay

WAREHOUSE LIGHTING: TBD

WAREHOUSE COOLING: TBD

*All improvements/specifications subject to changes

FLOOR PLAN - BUILDING B

Lease Rate: $0.62-$0.72

GRADE LEVEL LOADING DOOR

DOCK DOOR LOADING DOOR

Page 7: FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - … · 2019-05-22 · FOR LEASE 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 ±101,308 SF SWC DIABLO DRIVE AND EDMOND STREET,

FOR LEASE - 3 INDUSTRIAL BUILDINGS RANGING FROM ±23,546 - ±101,308 SF

SW C DI A B LO DR I V E A N D E D M ON D S T R E E T, L A S V E G A S , N V 8 9 1 1 8

NEVADA STATE INDUSTRIAL PARK

E

4

D

C

B

A

3 2 1150'-0"

50'-0" 50'-0" 50'-0"

200'

-0"

75'-0"25'-0"50'-0"

60'-0"

100'

-0"

50'-0

"50

'-0"

30'-0

"

BUILDING23,547 S.F.

RISER75 S.F.

TRUCK DOCK

CO

NT

RA

CT

OR

:T

hese

pla

ns a

re p

repa

red

and

subm

itted

by

the

cont

ract

oras

an

exem

ptio

n to

NR

S 62

3.33

0 fo

r w

ork

unde

r co

ntra

ctor

licen

se c

ateg

ory

auth

oriz

ed u

nder

NR

S 62

4.

LM

CO

NST

RU

CT

ION

CO

.(C

ompa

ny N

ame)

# 0

0425

96A

(Con

trac

tors

Lic

ense

#)

MIK

E B

RO

WN

(Pla

ns P

repa

red

By)

(Sig

natu

re)

Cop

yrig

ht

©M

ater

ial .

All

right

s re

serv

ed

None

of t

he m

ater

ials

prov

ided

on

this

docu

men

t may

be

used

, rep

rodu

ced

ortra

nsm

itted,

in w

hole

or in

par

t, in

any f

orm

or b

y any

mea

ns, e

lectro

nic o

r mec

hanic

al,inc

luding

pho

toco

pying

, rec

ordin

g or

the

use

of a

ny in

form

ation

stor

age

and

retri

eval

syste

m wi

thout

the pe

rmiss

ion in

writi

ng fr

om th

e pub

lishe

r. To

requ

est s

uch p

ermi

ssion

and

for f

utur

e in

quire

s, c

onta

ct L

M C

onst

ruct

ion

Co. L

LC. F

urth

erm

ore,

the

work

s of

auth

orsh

ip c

onta

ined

in th

ese

plan

s, in

cludi

ng b

ut n

ot lim

ited

to a

ll des

ign,

text

and

imag

es, a

re o

wned

, exc

ept a

s ot

herw

ise s

tate

d, b

y L

M C

onst

ruct

ion

Co. L

LC.

or o

ne o

f its

affi

liate

s an

d m

ay n

ot b

e co

pied

, rep

rodu

ced,

tran

smitt

ed, d

ispla

yed,

perfo

rmed

, dis

tribu

ted,

rent

ed, s

ub li

cens

ed, a

ltere

d, s

tore

d fo

r sub

sequ

ent

use

in w

hole

or i

n pa

rt in

any

man

ner w

ithou

t the

exp

ress

ed w

ritte

n co

nsen

t of

L M

C

on

stru

ctio

n C

o. L

LC

.

USE

OF

THES

E DR

AWIN

GS

IS L

IMIT

ED T

O A

SPE

CIFI

ED P

ROJE

CT F

OR

PERS

ONS

NAM

ED H

EREO

N AN

D FO

R TH

E CO

NSTR

UCTI

ON O

F ON

E PR

OJEC

T.

CO

NST

RU

CTI

ON

CO

.50

75 C

AM

ER

ON

SU

ITE

#H

LAS

VE

GA

S, N

EV

AD

A 8

9118

(702

) 262

-603

2, F

AX

(702

) 262

-615

0N

EV

AD

A L

IC. #

004

2596

A

PRELIMINARY

DRAWN BY:CHECKED BY:JOB NUMBER:DATE:

DESCRIPTION DATE

P3318

PRO

POSE

D O

FFIC

E/W

AR

EHO

USE

LAS

VEG

AS,

NV

891

18SW

CO

RN

ER O

F D

IAB

LO &

ED

MO

ND

S

A1.1C

FLO

OR

PL

AN

-BU

ILD

ING

"C

"

SCALE:11 FLOOR PLAN-BUILDING "C"3/32" = 1'-0"

NORTH 5-4-18

C-2±23,546 SF

CONSTRUCTION: The structure is to be a rear loaded concrete tilt up building.

DEMISING WALL: N/A

PAVING:All Auto paving 2” AC over 6” Type II, All Truck paving 3” AC over 6” Type II or as recommended by the Project’s soils engineer.

SLAB ON GRADE:Slab on grade to be nominal 6” thick 4,500 psi material, reinforced with #4 rebar at 18” OCTW

DOCK APRON: 60’ concrete dock apron out from the building wall.

COLUMN SPACING: Varies, but approximately 50’x50’ typical.

STAIRS: Dock stairs as required by code

ROOFING:Single-ply, TPO roof, with hybrid wood deck and steel truss, 10 year manufacturer’s warranty

INSULATION: R-30 batt insulation at underside of roof deck and white scrim sheet

DOCK DOORS: Two (2) 9’-6” x 10’ dock high loading doors

DOCK EQUIPMENT Dock bumpers installed at each dock door

GRADE DOORS:Two (2) 14’ x 16’ grade level loading door. The grade doo shall be a 24 gauge sectional vertical lift, manually operated and non-insulated door

SKYLIGHTS:386-degree fusible link, single dome, Laine Air or equal, to exceed code minimum. ±2% of the roof area.

FIRE PROTECTION:Fire-sprinkler system designed to .45/3,000 density for ability to include “High pile storage”

ELECTRICAL SERVICE:The Premises will feature 277/480 volt, 3-phase, 4-wire, 800 amp service. Emergency lighting at man door exits

CLEAR HEIGHT:The clear height for the warehouse area of the building will be ±28’ min at the first column line past the speed bay

WAREHOUSE LIGHTING: TBD

WAREHOUSE COOLING: TBD

*All improvements/specifications subject to changes

FLOOR PLAN - BUILDING C

Lease Rate: $0.82

GRADE LEVEL LOADING DOOR