ð15Þ ð15Þ ð15Þ Since these special requirements, which are based on ser- vice, material, and thickness, do not apply to every welded joint, only those joints to which special require- ments apply are included in the categories. The special re- quirements apply to joints of a given category only when specifically stated. The joints included in each category are designated as joints of Categories A, B, C, and D. Figure NC-3351-1 illustrates typical joint locations included in each category. NC-3351.1 Category A. Category A comprises longi- tudinal welded joints within the main shell, communicat- ing chambers, 23 transitions in diameter, or nozzles; any welded joint within a sphere, within a formed or flat head, or within the side plates 24 of a flatsided vessel; circum- ferential welded joints connecting hemispherical heads to main shells, to transitions in diameters, to nozzles, or to communicating chambers. NC-3351.2 Category B. Category B comprises cir- cumferential welded joints within the main shell, commu- nicating chambers, 23 nozzles, or transitions in diameter including joints between the transition and a cylinder at either the large or small end; circumferential welded joints connecting formed heads other than hemispherical to main shells, to transitions in diameter, to nozzles, or to communicating chambers. NC-3351.3 Category C. Category C comprises welded joints connecting flanges, Van Stone laps, tubesheets, or flat heads to main shell, to formed heads, to transitions in diameter, to nozzles, or to communicating chambers 23 and any welded joint connecting one side plate 22 to another side plate of a flatsided vessel. NC-3351.4 Category D. Category D comprises welded joints connecting communicating chambers 23 or nozzles to main shells, to spheres, to transitions in diameter, to heads, or to flatsided vessels and those joints connecting nozzles to communicating chambers. For nozzles at the small end of a transition in diameter, see Category B. NC-3352 Permissible Types of Welded Joints The design of the vessel shall meet the requirements for each category of joint. Butt joints are full penetration joints between plates or other elements that lie approxi- mately in the same plane. Category B angle joints between plates or other elements that have an offset angle α not exceeding 30 deg are considered as meeting the require- ments for butt joints. Figure NC-3352-1 shows typical butt welds for each category joint. NC-3352.1 Joints of Category A. All welded joints of Category A shall meet the fabrication requirements of NC-4241 and shall be capable of being examined in accor- dance with NC-5210. NC-3352.2 Joints of Category B. All welded joints of Category B shall meet the fabrication requirements of NC-4242 and shall be capable of being examined in accor- dance with NC-5220. NC-3352.3 Joints of Category C. All welded joints of Category C shall meet the fabrication requirements of NC-4243 and shall be capable of being examined in accor- dance with NC-5230. NC-3352.4 Joints of Category D. All welded joints of Category D shall be in accordance with the requirements of NC-3359 and one of (a) through (e) below. Figure NC-3351-1 Welded Joint Locations Typical of Categories A, B, C, and D 90 ASME BPVC.III.1.NC-2015 For ASME Committee use only. Record #16-614 Page 1 of 10 3/9/2016

Upload: others

Post on 30-Apr-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: For ASME Committee use only

ð15Þ

ð15Þ

ð15Þ

Since these special requirements, which are based on ser-vice, material, and thickness, do not apply to everywelded joint, only those joints to which special require-ments apply are included in the categories. The special re-quirements apply to joints of a given category only whenspecifically stated. The joints included in each categoryare designated as joints of Categories A, B, C, and D. FigureNC-3351-1 illustrates typical joint locations included ineach category.

NC-3351.1 Category A. Category A comprises longi-tudinal welded joints within the main shell, communicat-ing chambers,23 transitions in diameter, or nozzles; anywelded joint within a sphere, within a formed or flat head,or within the side plates24 of a flat‐sided vessel; circum-ferential welded joints connecting hemispherical headsto main shells, to transitions in diameters, to nozzles, orto communicating chambers.

NC-3351.2 Category B. Category B comprises cir-cumferential welded joints within the main shell, commu-nicating chambers,23 nozzles, or transitions in diameterincluding joints between the transition and a cylinder ateither the large or small end; circumferential weldedjoints connecting formed heads other than hemisphericalto main shells, to transitions in diameter, to nozzles, or tocommunicating chambers.

NC-3351.3 Category C. Category C comprises weldedjoints connecting flanges, Van Stone laps, tubesheets, orflat heads to main shell, to formed heads, to transitionsin d iameter , to nozz les , or to communica t ingchambers23 and any welded joint connecting one sideplate22 to another side plate of a flat‐sided vessel.

NC-3351.4 Category D. Category D compriseswelded joints connecting communicating chambers23 ornozzles to main shells, to spheres, to transitions in

diameter, to heads, or to flat‐sided vessels and thosejoints connecting nozzles to communicating chambers.For nozzles at the small end of a transition in diameter,see Category B.

NC-3352 Permissible Types of Welded JointsThe design of the vessel shall meet the requirements

for each category of joint. Butt joints are full penetrationjoints between plates or other elements that lie approxi-mately in the same plane. Category B angle joints betweenplates or other elements that have an offset angle α notexceeding 30 deg are considered as meeting the require-ments for butt joints. Figure NC-3352-1 shows typicalbutt welds for each category joint.

NC-3352.1 Joints of Category A. All welded joints ofCategory A shall meet the fabrication requirements ofNC-4241 and shall be capable of being examined in accor-dance with NC-5210.

NC-3352.2 Joints of Category B. All welded joints ofCategory B shall meet the fabrication requirements ofNC-4242 and shall be capable of being examined in accor-dance with NC-5220.

NC-3352.3 Joints of Category C. All welded joints ofCategory C shall meet the fabrication requirements ofNC-4243 and shall be capable of being examined in accor-dance with NC-5230.

NC-3352.4 Joints of Category D. All welded joints ofCategory D shall be in accordance with the requirementsof NC-3359 and one of (a) through (e) below.

Figure NC-3351-1Welded Joint Locations Typical of Categories A, B, C, and D

90

ASME BPVC.III.1.NC-2015

For ASME Committee use only.

Record #16-614Page 1 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Errata: Should be endnote 24, not endnote 22.
Page 2: For ASME Committee use only

(b) For through‐thickness temperature differences, adjacent points are defined as any two points on a line normal toany surface.

13 Normal service is defined as any set of service conditions other than startup and shutdown that are specified for thevessel to perform its intended function.

14 Adjacent points are defined as points that are spaced less than the distance from each other, where R and t arethe mean radius and thickness, respectively, of the vessel, nozzle, flange, or other part in which the points arelocated.

15 The head design curves have been developed considering membrane stress requirements, plastic collapse, cyclicload conditions, and the effects of maximum allowable tolerances in accordance with NC-4222. See Section III Ap-pendices, Nonmandatory Appendix A, Article A-4000 for the design equations for the curves of Figure NC-3224.6-1.

16 Heads having D/2h = 2 have equivalent torispherical properties of a torisphere of L/D = 0.90 and r/D = 0.17.

17 The minimum thickness for all pipe materials is the nominal thickness listed in Table 2 of ASME B36.10M less121/2%. For diameters other than those listed in the table, the minimum thickness shall be that of the next largerpipe size.

18 The equations provide safe construction as far as stress is concerned. Greater thicknesses may be necessary if de-flection would cause leakage at threaded or gasketed joints.

19 When axial compressive loadings occur in addition to the external pressure, the combined axial loading shall meetthe requirements of NC-3245.

20 Stress means the maximum normal stress.

21 Since Hr hr in some cases will subtract from the total moment, the moment in the flange ring when the internalpressure is zero may be the determining loading for the flange design.

22 The rules in NC-3329(f) apply to ligaments between tube holes and not to single openings. They may give lowerefficiencies in some cases than those for symmetrical groups that extend a distance greater than the inside diameterof the shell as covered in NC-3329(c). When this occurs, the efficiencies computed by the rules under NC-3329(b)shall govern.

23 Communicating chambers are defined as appurtenances to the vessel that intersect the shell or heads of a vessel andform an integral part of the pressure-retaining enclosure, such as sumps.

24 Side plates of a flat‐sided vessel are defined as any of the flat plates forming an integral part of the pressure-retainingenclosure.

25 Written for fittings with internal threads but also applicable to externally threaded and socket- or butt-weldedfittings.

26 All dimensions given are nominal.

27 It is recognized that other acceptable procedures may exist which also constitute adequate design methods, and it isnot the intention to rule out these alternative methods, provided they can be shown to have been satisfactory byactual service experience.

28 Expansion Joint Manufacturers Association, 25 North Broadway, Tarrytown, NY 10591.

29 See Section III Appendices, Mandatory Appendix II, II‐1520(g).

30 The pressure term in eqs. NC-3652(8), NC-3653.1(a)(9a), NC-3653.1(b)(9b)and NC-3653.2(c)(11) may not applyfor bellows and expansion joints.

31 Design Pressure may be used if the Design Specification states that peak pressure and earthquake need not be takenas acting concurrently.

32 Socket welds should not be used where the existence of crevices could accelerate corrosion.

33 Fillet and partial penetration welds should not be used where severe vibration is expected.

34 These rules do not limit storage tanks from being installed below grade or below ground, provided the tanks are notsubject to external pressure resulting from earth or fill.

ASME BPVC.III.1.NC-2015

300

For ASME Committee use only.

Record #16-614Page 2 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Correct endnote
rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
Page 3: For ASME Committee use only

NC-3853.7 Welding of Roof Plates. Roof plates shallbe welded in accordance with NC-4246.4. The size of theroof to top angle weld shall be 3/16 in. (5 mm) or less.

NC-3854 Supported Flat RoofsNC-3854.1 General Requirements. The use of sup-

ported flat roofs shall be limited to tanks having dia-meters not greater than 35 ft (11 m). The design ofsupported flat roofs shall be in accordance withNC-3853 except as noted NC-3854.2.

NC-3854.2 Main Supporting Members.(a) Requirements of NC-3853.1 do not apply.(b) Supporting structural members may be either inter-

nal or external to the roof plate.(c) External rafters shall not be welded to the top angle

or attached to the shell plate.(d) External rafters shall be welded to the roof plate.

The weld shall be sized to carry the combined dead andlive loads on the roof plate.

NC-3855 Self-Supporting Cone RoofsNC-3855.1 Nomenclature. The symbols used are de-

fined as follows:

At = combined cross‐sectional area of roof plate, shellplate, and top shell angle, in.2 (mm2)

D = nominal diameter of tank shell, ft (m)f = tensile working stress for the material of the roof

plates, shell plates, or top shell angle, whichever isthe least value, at the service temperature, psi(MPa)

P = dead load of roof, plus the live load, lb/ft2 (kPa)R = radius of curvature of roof, ft (m)t r = nominal thickness of roof plates, in. (mm)θ = angle of cone elements with the horizontal, deg

NC-3855.2 Design Requirements. Self‐supportingcone roofs shall conform to the requirements40 of (a)through (c) below.(a) Slope

(1)Maximum θ = 37 deg (tangent = 9:12)(2)Min imum s in θ = 0 .165 [s lope 2 in ./ f t

(167 mm/m) (16.7%)](b) Plate Thickness

(1)Minimum/Maximum

(U.S. Customary Units)

(SI Units)

(2) Self‐supporting roofs having the roof plates stif-fened by sections welded to the plates need not conformto the minimum thickness requirements but shall be notless than 3/16 in. (5 mm).(c) Top Angle to Roof‐to‐Shell Joint. The cross‐sectional

area of the top angle, in.2 (mm2), plus the cross‐sectionalareas of the shell and roof plates within a distance of 16times their thicknesses, measured from their most remotepoint of attachment to the top angle, shall equal orexceed:

(U.S. Customary Units)

(SI Units)

NC-3856 Self-Supporting Dome and UmbrellaRoofs

NC-3856.1 Nomenclature. See NC-3855.1 fornomenclature.

NC-3856.2 Design Requirements. Self‐supportingdome and umbrel la roofs shal l conform to therequirements37 of (a) through (c) below.(a) Radius of Curvature

(b) Plate Thickness(1)Minimum/Maximum

(U.S. Customary Units)

(SI Units)

(2) Self‐supporting roofs having the roof plates stif-fened by sections welded to the plates need not conformto the minimum thickness requirements but shall be notless than 3/16 in. (5 mm).(c) Top Angle to Roof‐to‐Shell Joint. The cross‐sectional

area of the top angle, in.2 (mm2), plus the cross‐sectionalareas of the shell and roof plates within a distance of 16

166

ASME BPVC.III.1.NC-2015

For ASME Committee use only.

Record #16-614Page 3 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Errata: Should be end note 40, not end note 37.
Page 4: For ASME Committee use only

35 The limitation of the Design Pressure to atmospheric is not intended to preclude the use of these tanks at vapor pres-sure slightly above or below atmospheric within the range normally required to operate vent valves. If these pres-sures or vacuums exceed 0.03 psi (0.2 kPa), especially in combination with large diameter tanks, the forces involvedmay require special consideration in the design.

36 Any specified corrosion allowance for the shell plates shall be added to the calculated thickness.

37 The nominal thickness of shell plates refers to the tank shell as constructed. The thicknesses specified are based onerection requirements.

38 API Standard 2000, 1968 Edition, Venting Atmospheric and Low Pressure Storage Tanks, American Petroleum In-stitute, 1220 L Street, NW, Washington, DC, 20005‐4070.

39 The decrease in yield stress at Design Temperature shall be taken into account.

40 The equations applying to self‐supporting roofs provided for a uniform live load of 25 lb/ft2 (1.2 kPa).

41 Whenever a tank is to be operated with liquid levels that at no time reach the top of the roof but is to be filled to thetop of the roof during the hydrostatic test, it shall be designed for both of these maximum liquid level conditions,using in each case the density of the liquid employed. If a tank is not designed to be filled to the top of the roof, over-fill protection is required.

42 A suitable margin shall be allowed between the pressure normally existing in the gas or vapor space and the pres-sure at which the relief valves are set so as to allow for the increases in pressure caused by variations in the tem-perature or gravity of the liquid contents of the tank and other factors affecting the pressure in the gas or vaporspace.

43 This partial vacuum shall be greater than that at which the vacuum relief valves are set to open.

44 Recommended Rules for Design and Construction of Large, Welded, Low‐Pressure Storage Tanks, published byAmerican Petroleum Institute, 1220 L Street, NW, Washington, DC 20005‐4070.

45 These rules do not apply when the circumferential stress on a cylindrical wall is compressive as in a cylinder actedupon by external pressure.

46 In these expressions if the unit force is latitudinal, R shall be considered to be R1 and, if meridional, R shall be con-sidered as equal to R2 .

47 (a) Equation NC-3932.2(a)(2) has been derived from a summation of the components, normal to the surface, of theT1 and T2 forces acting on a unit area of the tank wall subjected only to a pressure P . To be technically correct, thenormal to the surface components of other loads, such as metal, snow, or insulation, should be added to or sub-tracted from the term P . For the usual internal Design Pressure, these added loads are small compared to the pres-sure P , and can be omitted without significant error. When the pressure P is relatively small, including the case of apartial vacuum loading, the other load components can have a substantial effect on the calculated T2 force and theresultant thickness.(b) Example F.3.01 in Appendix F of API 620 Feb. 1970 Edition calculates the required roof thicknesses under a smallvacuum by considering the metal, insulation, and snow loads in eqs. NC-3932.2(a)(1), NC-3932.2(a)(2),NC-3932.2(e)(1)(3), and NC-3932.2(e)(1)(4). The designer should note that if these loads had been omitted the cal-culated thicknesses would have been much less than the correct values.(c) In eqs. NC-3932.2(a)(1), NC-3932.2(e)(1)(3), NC-3932.2(e)(2)(6), and NC-3932.2(e)(3)(8), the term W is in-tended to include loads, such as metal weight, of significant value. At points away from the vertical center line ofthe roof, the value of T2 is required for the thickness calculations of eqs. NC-3932.3(d), Step 1(16), NC-3932.3(d), Step 3(18), and NC-3932.3(d), Step 5(20), and the value of P in eqs. NC-3932.2(a)(2), NC-3932.2(e)(1)(4),and NC-3932.2(e)(2)(7) must be modified by the normal components of the added loads for the correct determina-tion of T2.

48 These rules do not contain provisions in respect to the design of cylindrical sidewalls subject to partial internal vac-uum in tanks constructed for storage of gases or vapors alone.

49 The vacuum relief valve or valves shall be set to open at a smaller partial vacuum so that the 1 oz/in.2 (0.43 kPa)partial vacuumwill not be exceeded when the inflow of air or gas through the valves is at its maximum specified rate.

50 If external anchor bolts are used for resisting such uplift, it is recommended that their nominal diameter be not lessthan 1 in. (25 mm) plus a corrosion allowance of at least 1/4 in. (6 mm) on the diameter.

ASME BPVC.III.1.NC-2015

301

For ASME Committee use only.

Record #16-614Page 4 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Correct endnote
rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
Page 5: For ASME Committee use only

ð15Þ

th = thickness, in. (mm), of the roof or bottom plate atand near the juncture of the roof or bottom andsidewalls, including corrosion allowance

Wc = corresponding width, in. (mm), of the participatingsidewall plate

Wh = width, in. (mm), of the roof or bottom plate consid-ered to participate in resisting the circumferentialforce acting on the compression ring region

α = angle between the direction of T1 and a verticalline. In a conical surface it is also one‐half of the to-tal vertex angle of the cone.

NC-3933.2 General Requirements. When the roof orbottom of a tank is a cone or partial sphere and is at-tached to cylindrical sidewalls, the membrane stressesin the roof or bottom act inward on the periphery of thesidewalls. This results in circumferential compressiveforces at the juncture, which shall be resisted either bya knuckle curvature in the roof or bottom or by a limitedzone at the juncture of the intersecting roof or bottomplates and sidewall plates, supplemented in some casesby an angle, a rectangular bar, or a ring girder.

NC-3933.3 Requirements for Knuckle Regions.(a) If a curved knuckle is provided, a ring girder or

other form of compression ring shall not be used andthere shall be no sudden changes in the direction of ameridional line at any point. In addition, the radius of cur-vature of the knuckle in a meridional plane shall not beless than 6%, and preferably not less than 12%, of the dia-meter of the sidewalls.52 Subject to the provisions of (b)below, the thickness of the knuckle at all points shall sa-tisfy the requirements of NC-3932.(b) Application of the equations in NC-3932.2 to levels

immediately above and below a point where two surfacesof differing meridional curvature have a common meri-dional tangent, as at the juncture between the knuckle re-gion and the spherically dished portion of a torisphericalroof, will result in the calculation of two latitudinal unitforces, differing in magnitude and possibly in sign, atthe same point. The latitudinal unit force at such a pointwill be between the two calculated values, depending onthe geometry of the tank wall in that area.

NC-3933.4 Requirements for Compression Rings.(a) If a curved knuckle is not provided, forces shall be

resisted by other means in the compression ring regionof the tank walls. The zone of the tank walls at the junc-ture between the roof or bottom and the sidewalls in-cludes that width of plate on each side of the juncturewhich is considered to participate in resisting these forces[Figure NC-3933.4(a)-1]. The thickness of the wall plateon either side of the juncture shall not be less than thethickness needed to satisfy the requirements of

NC-3932, and the widths of plate making up the compres-sion ring region shall be computed from the followingequations:

ð22Þ

ð23Þ

(b) The magnitude of the total circumferential forceacting on any vertical cross section through the compres-sion ring region shall be computed as follows:

ð24Þ

and the net cross‐sectional area provided in the compres-sion ring region shall not be less than that found to be re-quired by the following equation:

(U.S. Customary Units)

ð25Þ

(SI Units)

depending on whether the value of Q as determined byeq. (24) is negative53 or positive.

NC-3933.5 Details of Compression Ring Regions.

(a) If the force Q is negative, indicating compression,the horizontal projection of the effective compressionring region shall have a width in a radial direction not lessthan 0.015 times the horizontal radius of the tank wall atthe level of the juncture between the roof or bottom and

Figure NC-3933.4(a)-1Compression Ring Region

186

ASME BPVC.III.1.NC-2015

For ASME Committee use only.

Record #16-614Page 5 of 10

3/9/2016

rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
Page 6: For ASME Committee use only

ð15Þ

the sidewalls. If such projected width does not meet thisrequirement, appropriate corrective measures shall be ta-ken as specified in this subparagraph.

(b)Whenever the circumferential force Q determinedin accordance with NC-3933.4 is of such magnitude thatthe area required by eq. NC-3933.4(b)(25) is not providedin a compression ring region with plates of the minimumthicknesses established by the requirements of NC-3932,or when Q is compressive and the horizontal projection ofthe width wh is less than specified in (a), the compressionring region shall be reinforced either by thickening theroof or bottom and sidewall plates as required to providea compression ring region having the necessary cross‐sectional area and width as determined on the basis ofthe thicker plates,54 or by adding an angle, a rectangularbar, or a ring girder at the juncture of the roof or bottomand sidewall plates, or by a combination of thesealternatives.

(c) An angle, bar, or ring girder, if used, may be locatedeither inside or outside of the tank55 and shall have across section of such dimensions that:

(1) its area makes up the deficiency between the areaAc , required by eq. NC-3933.4(b)(25), and the cross‐sectional area provided by the compression ring regionin the walls of the tank;

(2) the horizontal width of the angle, bar, or ring gir-der is not less than 0.015 times the horizontal radius Rc ofthe tank wall at the level of the juncture of the roof or bot-tom and the sidewalls, except that, when the cross‐sectional area to be added in an angle or bar is not morethan one ‐half of the total area required by eq.NC-3933.4(b)(25), the width requirement for this mem-ber may be disregarded, provided the horizontal projec-tion of the width wh of participating roof or bottomplates alone is equal to or greater than 0.015Rc or, withan angle or bar located on the outside of a tank, thesum of the projection of the width wh and the horizontalwidth of the added angle or bar is equal to or greater than0.015Rc .

(3)when bracing must be provided as specified in(h), the moment of inertia of the cross section about ahorizontal axis shall be not less than that required byeq. (h)(26).

(d)When the vertical leg of an angle ring or a verticalflange of a ring girder is located on the sidewall of thetank, it may be built into the sidewall if its thickness isnot less than that of the adjoining wall plates. However,if this construction is not used, the leg, edge, or flangeof the compression ring next to the tank shall make con-tact with the wall of the tank around the entire circumfer-ence and, except as provided in (e) below, shall beattached along both the top and bottom edges by contin-uous fillet welds. These welds shall be of sufficient size totransmit the portion, Qp of the total circumferential forceQ , to the compression ring angle, bar, or girder, assuming,in the case of welds separated by the width of a leg orflange of a structural member as shown in Figure

NC-3933.5(d)-1 sketches (a) and (d), that only the weldnearest the roof or bottom is effective. The part thick-nesses and weld sizes in Table NC-4247.6(d)-1 relate todimensions in the as-welded condition before deductionof corrosion allowances, but all other part thicknessesand weld sizes referred to, in this subparagraph, relateto dimensions after deduction of corrosion allowance.

(e) If a continuous weld is not needed for strength or asa seal against corrosive elements, attachment welds alongthe lower edge of a compression ring on the outside of atank may be intermittent, provided:

(1) the summation of their lengths is not less thanone‐half the circumference of the tank;

(2) the unattached width of tank wall between theends of welds does not exceed eight times the tank wallthickness exclusive of corrosion allowance;

(3) the welds are of such size as needed for strengthbut in no case smal ler than speci f ied in TableNC-4247.6(d)-1.

(f) The projecting part of a compression ring shall beplaced as close as possible to the juncture between theroof or bottom plates and the sidewall plates.

(g) If a compression ring on either the inside or outsideof a tank is of such shape that liquid may be trapped, itshall be provided with adequate drain holes uniformlydistributed along its length. Similarly, if the shape of acompression ring on the inside of a tank is such that gaswould be trapped on the underside thereof when the tankis being filled with liquid, adequate vent holes shall beprovided along its length. Where feasible, such drain orvent holes shall be not less than 3/4 in. (19 mm) indiameter.

(h) The projecting part of a compression ring withoutan outer vertical flange need not be braced, providedthe width of such projecting part in a radial vertical planedoes not exceed 16 times its thickness. With this excep-tion, the horizontal part of the compression ring shallbe braced at intervals around the circumference of thetank with brackets or other suitable members securely at-tached to both the ring and the tank wall to prevent suchpart of the ring from buckling laterally. When such bra-cing is required, the moment of inertia of the cross sectionof the angle, bar, or ring girder about a horizontal axisshall be not less than that calculated to be required bythe following equation:56

(U.S. Customary Units)

ð26Þ

(SI Units)

187

ASME BPVC.III.1.NC-2015

For ASME Committee use only.

Record #16-614Page 6 of 10

3/9/2016

rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
Page 7: For ASME Committee use only

where

I1 = required moment of inertia, in.4 (mm4), for thecross section of a steel compression ring with re-spect to a horizontal axis through the centroid ofthe section, not taking credit for any portion ofthe tank wall, except that, in the case of an anglering whose vertical leg is attached to or forms apart of the tank wall, the moment of inertia of onlythe horizontal leg shall be considered, and it shallbe figured with respect to a horizontal axis throughthe centroid of such leg55

k = a constant whose value depends on the magnitudeof the angle θ, subtended at the central axis of thetank by the space between adjacent brackets, orother supports, which value shall be determinedfrom the following tabulation in which n is thenumber of brackets or other supports evenlyspaced around the circumference of the tank

Some Values for k Based on n , θ

n 30 24 20 18 15 12θ , deg 12 15 18 20 24 30

k 186.6 119.1 82.4 66.6 45.0 29.1

Table continued

n 10 9 8 6 5 4θ , deg 36 40 45 60 72 90

k 20.0 16.0 12.5 6.7 4.4 2.6

GENERAL NOTE: In no case shall θ be larger than 90 deg.

Qp = that portion of the total circumferential force Q , lb(N), [eq. NC-3933.4(b)(24)] that is carried by thecompression ring angle, bar, or girder, as computedfrom the ratio of the cross‐sectional area of thecompression ring to the total area of the compres-sion zone

Rc = horizontal radius, in. (mm), of the cylindrical side-wall of the tank at its juncture with the roof orbottom

NC-3934 Nozzle Piping TransitionsThe stress limits of Table NC-3921.8-1 shall apply to all

portions of nozzles which lie within the limits of rein-forcement given in NC-3334, except as provided in

Figure NC-3933.5(d)-1Permissible Details of Compression Ring

t

(a)

16t, max.

Bracket

Permissible

Permissible Permissible where roof or bottom plate thickness is not over 1/4 in. (6 mm)

Built-up channel girders may also be used

t

16t, max.

Bracket

(b)

(d)

(c)

cL

(e)

NC-3933.5(d)

GENERAL NOTE: NC-3350 gives limitations concerning location where various types of welded joints may be used.

188

ASME BPVC.III.1.NC-2015

For ASME Committee use only.

Record #16-614Page 7 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Errata: Should be end note 56, not end note 55.
Page 8: For ASME Committee use only

51 These forces are computed by the applicable equations in NC-3932.

52 Use of a knuckle radius as small as 6% of the sidewall diameter will frequently require an excessively heavy thick-ness for the knuckle region. The thickness requirements for such region will be found more reasonable if a largerknuckle radius is used.

53 Because of the discontinuities and other conditions found in a compression ring region, biaxial stress design criteriaare not considered applicable for a compressive force determined as in eq. NC-3933.4(b)(24). Experience has shownthat a compressive stress of the order of 15.0 ksi (103 MPa) as indicated in eq. NC-3933.4(b)(25), is permissible inthis case, provided the requirements of NC-3933.5 are satisfied.

54 Note that, unless the effect of the unit forces T2 and T2 s on the resulting increments in width of participating platemay safely be neglected, the use of thicker plates involves recomputing not onlywh andwc but also Q and Ac for theincreased plate thicknesses; hence, the design of the compression ring region in this case resolves into a trial anderror procedure.

55 See Figure NC-3933.5(d)-1 for some acceptable details of construction of compression rings.

56 Note that the value required for I1 as calculated from eq. NC-3933.5(h)(26) is not applicable for materials other thansteel.

57 See NC-4246 and NC-4247 for special weld joint requirements in storage tanks.

58 One test specimen may represent a group of forgings, provided they are of the same nominal dimensions, from thesame heat of material and the same heat treatment lot, and forged in the same manner.

59 Written and illustrated with internal threads but also applicable to externally threaded and socket- or butt-weldedfittings.

60 An intermediate postweld heat treatment for this purpose is defined as a postweld heat treatment performed on aweld within a temperature range not lower than the minimum holding temperature range to which the weld will besubjected during the final postweld heat treatment.

61 See NC-5250 for vessels designed to NC-3200. See NC-5280 for requirements for storage tank welds.

62 Welds in branch piping runs shall be examined as required by NC-5212 and NC-5222.

63 SNT‐TC‐1A is a Recommended Practice for Nondestructive Testing Personnel Qualification and Certification pub-lished by the American Society for Nondestructive Testing, 1711 Arlingate Lane, P.O. Box 28518, Columbus, Ohio43228‐0518.

64 Personnel qualified by examination and certified to previous editions of SNT‐TC‐1A are considered to be qualified tothe edition referenced in Table NCA‐7100-2 when the recertification is based on continuing satisfactory perfor-mance. All reexaminations and new examinations shall be in accordance with the edition referenced in TableNCA‐7100-2.

65 Employer as used in this Article shall include: N Certificate Holders; Quality System Certificate Holders; Material Or-ganizations that are qualified in accordance with NCA‐3842; and organizations who provide subcontracted nondes-tructive examination services to organizations described above.

66 These tests may be made with the item being tested partially filled with liquid, if desired.

67 Temperature fluctuations within the piping system may affect the pressure. Precautions must be taken to ensurethat the test is not biased by temperature effects.

68 Wherever the word system appears in this Article, it refers to the component or group of components for which over-pressure protection is provided as described in the Overpressure Protection Report.

69 A pressure relief device is designed to open to prevent a rise of internal fluid pressure greater than a specified value,resulting from exposure to pressure transient conditions. It may also be designed to prevent excessive internal vac-uum. It may be a pressure relief valve, a nonreclosing pressure relief device, or a vacuum relief valve.

70 A pressure relief valve is a pressure relief device that is designed to reclose and prevent the further flow of fluid afternormal conditions have been restored.

71 A nonreclosing pressure relief device is a pressure relief device designed to remain open after operation.

ASME BPVC.III.1.NC-2015

302

For ASME Committee use only.

Record #16-614Page 8 of 10

3/9/2016

rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Correct endnote
Page 9: For ASME Committee use only

(b) Plate Thickness

(U.S. Customary Units)

(SI Units)

but not less than 3/16 in. (5 mm) nominal.

(c) Top Angle to Roof‐to‐Shell Joint. The cross‐sectionalarea of the top angle, in square inches (mm2), plus thecross‐sectional areas of the shell and roof plates withina distance of 16 times their thicknesses, measured fromtheir most remote point of attachment to the top angle,shall equal or exceed

(U.S. Customary Units)

(SI Units)

ND-3856 Self-Supporting Dome and UmbrellaRoofs

ND-3856.1 Nomenclature. See ND-3855.1 fornomenclature.

ND-3856.2 Design Requirements for Ferrous Mate-rial. Self‐supporting dome and umbrella roofs shall con-form to the requirements33 of (a) through (c) below.

(a) Radius of Curvature

R = D unless otherwise specified

Minimum R = 0.80D

Maximum R = 1.2D

(b) Plate Thickness

(1)Minimum but not less

than 3/16 in. (5 mm). Maximum t = 1/2 in. (13 mm)

(2) Self‐supporting roofs having the roof plates stif-fened by sections welded to the plates need not conformto the minimum thickness requirements but shall be notless than 3/16 in. (5 mm).

(c) Top Angle to Roof‐to‐Shell Joint. The cross‐sectionalarea of the top angle, in square inches (mm2), plus thecross‐sectional areas of the shell and roof plates withina distance of 16 times their thicknesses, measured fromtheir most remote point of attachment to the top angle,shall equal or exceed

(U.S. Customary Units)

(SI Units)

ND-3856.3 Design Requirements for AluminumMa-terial. Self‐supporting dome and umbrella roofs shallconform to the requirements of (a) through (c) below:

(a) Radius of Curvature

Minimum R = 0.80D

Maximum R = 1.2D

(b) Plate Thickness

(U.S. Customary Units)

(SI Units)

but not less than 3/16 in. (5 mm) nominal.

(c) Top Angle to Roof‐to‐Shell Joint. The cross‐sectionalarea of the top shell angle, in square inches, plus thecross‐sectional areas of shell and roof plates within a dis-tance of 16 times their thicknesses, measured from theirmost remote point of attachment to the top shell angle,shall equal or exceed

(U.S. Customary Units)

(SI Units)

ND-3856.4 Top Angle Attachment for Self-Supporting Roofs.

(a) The top angle sections for self‐supporting roofsshall meet the requirements of ND-4246.6(d). Joint effi-ciency factors need not be applied.

(b) For self‐supporting roofs, the edges of the roofplates may be flanged horizontally to rest flat againstthe top angle to improve welding conditions.

153

ASME BPVC.III.1.ND-2015

For ASME Committee use only.

Record #16-614Page 9 of 10

3/9/2016

rzziegler
Rectangle
rzziegler
Rectangle
rzziegler
Callout
Errata: Should be endnote 35, not endnote 33.
Page 10: For ASME Committee use only

17 Communicating chambers are defined as appurtenances to the vessel that intersect the shell or heads of a vessel andform an integral part of the pressure-retaining closure, e.g., sumps.

18 Side plates of a flat sided vessel are defined as any of the flat plates forming an integral part of the pressure-retainingenclosure.

19 Written for fittings with internal threads but also applicable to externally threaded and socket or butt weldedfittings.

20 tD is defined in Section III Appendices, Mandatory Appendix XI, XI-3130.

21 All dimensions given, for size of vessel on which inspection openings are required, are nominal.

22 It is recognized that other acceptable procedures may exist that also constitute adequate design methods, and it isnot the intention to rule out these alternative methods provided they can be shown to have been satisfactory byactual service experience.

23 Expansion Joint Manufacturers Association, 25 North Broadway, Tarrytown, NY 10591.

24 See Section III Appendices, Mandatory Appendix II, II‐1520(g).

25 The pressure term in eqs. ND-3652(8), ND-3653.1(a)(9a), ND-3653.1(b)(9b) and ND-3653.2(c)(11) may not applyfor bellows and expansion joints.

26 Design Pressure may be used if the Design Specification states that peak pressure and earthquake need not be takenas acting concurrently.

27 Socket welded joints should not be used where the existence of crevices could result in accelerated corrosion.

28 Fillet and partial penetration welds should not be used where severe vibration is expected.

29 These rules do not limit storage tanks from being installed below grade or below ground, provided the tanks are notsubject to external pressure resulting from earth or fill.

30 The limitation of the Design Pressure to atmospheric is not intended to preclude the use of these tanks at vapor pres-sure slightly above or below atmospheric within the range normally required to operate vent valves. If these pres-sures or vacuums exceed 1/2 oz/in.

2, especially in combination with large diameter tanks, the forces involved mayrequire special consideration in the design.

31 Any specified corrosion allowance for the shell plates shall be added to the calculated thickness.

32 The nominal thickness of shell plates refers to the tank shell as constructed. The thicknesses specified are based onerection requirements.

33 API Standard 2000, 1968 Edition, Venting Atmospheric and Low Pressure Storage Tanks, American Petroleum In-stitute, 1220 L Street, NW, Washington, DC 20005‐4070.

34 The decrease in yield stress at Design Temperature shall be taken into account.

35 The equations applying to self‐supporting roofs provide for a uniform live load of 25 lb/ft2 (1.2 kPa).

36 Whenever a tank is to be operated with liquid levels that at no time reach the top of the roof, but is to be filled to thevery top of the roof during the hydrostatic test, it shall be designed for both of these maximum liquid level condi-tions, using in each case the density of the liquid employed. If a tank is not designed to be filled to the very top of theroof, overfill protection is required.

37 A suitable margin shall be allowed between the pressure normally existing in the gas or vapor space and the pres-sure at which the relief valves are set, so as to allow for the increases in pressure caused by variations in the tem-perature or gravity of the liquid contents of the tank and other factors affecting the pressure in the gas or vaporspace.

38 The partial vacuum shall be greater than that at which the vacuum relief valves are set to open.

39 Recommended Rules for Design and Construction of Large, Welded Low‐Pressure Storage Tanks, published byAmerican Petroleum Institute, 1220 L Street, NW, Washington, DC 20005‐4070.

ASME BPVC.III.1.ND-2015

284

For ASME Committee use only.

Record #16-614Page 10 of 10

3/9/2016

rzziegler
Text Box
NO CHANGES. THIS PAGE FOR INFORMATION ONLY
rzziegler
Rectangle
rzziegler
Callout
Correct endnote
rzziegler
Rectangle