flowmeters - fluid transfer international · pdf fileindustrial metering applications....
TRANSCRIPT
The Satam flowmeter range
is used for the custody transfer measurement of liquid
hydrocarbons, liquid gas
and liquid chemicals.
Consisting of four distinct families, the range is able
to meet the needs of most industrial metering applications. Flowmeters
• Positive Displacement meter
• Coriolis mass flowmeter
• Turbine flowmeter
• Ultrasonic flowmeter
Areas of activity: • Oil depots • Metering for road tankers • Aviation • Transport via pipeline
Positive Displacement meter
ZC17
The SATAM Positive Displacement meter (PD meter) is a system with freely-moving blades used to measure "white" petroleum products such as fuels, bio-fuels and refined liquid hydrocarbons. Its simple design using only two pairs of blades and one moving rotor makes it exceptionally robust and allows the user to make significant savings on maintenance costs.
Sectors of application
• Oil depots For product reception and loading stations for trucks, wagons and ships
• Hydrocarbon transportation Distribution of fuel oil or fuel by road tanker
• Aircraft refuelling Aircraft dispensers and aircraft fuelling tankers
• Army Depot supplies and loading of trucks
• Transport companies Refuelling of locomotives, trucks and public transport coaches
• Marine applications Refuelling of ships
• Mining sites Refuelling of trucks or site machinery
Key points
> Reduced pressure loss 0,3 to 0.5 bar at maximum flow rate
> Low maintenance costs Simple and robust design with mechanical components interchangeable between the different models
> Stability of measurements Accuracy of measurement guaranteed over a period of many years without any drift in the calibration curve
> Modular design Wide range of accessories for performing customized measurement applications
> Robust construction Flowmeter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement. Few moving parts
Positive Displacement meter ZC17
Technical specifications
Model
Maximum flowrate (m3/h)
(l/mn)
(USGPM)
Minimum flowrate (m3/h)
(l/mn)
(USGPM)
Application
Connection - Flanges
Materials
Diameter
Manifold
Casing
Front and back flanges
Rotor
Blades
Gaskets
Operating conditions Pressure
Viscosity
Liquid temperature
Ambient temperature
Pressure drop
Internal construction Cyclic volume (litres)
(US gallons)
Metrological performance Accuracy
Mass repeatability
Installation
Custody transfer approval
Straight inlet and outlet sections
0,33
0,08
0,40
0,10
Aluminium
2” 2”
Aluminium
ZC17 12
12
200
53
1,2
20
5,3
ZC17 24
24
400
105
2,4
40
10,5
ZC17 48
48
800
210
4,8
80
21
ZC17 80
80
1333
360
8
133
36
ZC17 150
150
2500
660
15
250
66
ZC17 250
250
4166
1100
25
416
110
Multi-product metering
2” 3” 4” 6”
Steel Steel or aluminium
Ductile iron or Ni resist iron
Kanigen-plated steel
Aluminium
Graphite
Viton (option nitrile)
0 to 10 bar / 0 to 150 PSI
Max. 800 mPa.s/ 800 cPo / 3850 SSU
-40°C (-40°F) à +60°C (+140°F)
-40°C (-40°F) à +60°C (+140°F)
Max. 0.5 bar
0,80
0,21
2,27
0,6
4,54
1,12
6,82
1,8
< ± 0.15% / Option< ± 0.1% / For 10:1 measuring range
< ± 0,02 %
Not necessary
EC Evaluation Certificate N° LNE - 11052
Weight and dimensions
Model
Distance between flanges (mm)
(inches)
Width (mm)
(inches)
Depth (mm)
(inches)
Height (mm)
(inches)
Weight net kg (lbs)
Gross kg (lbs)
ZC17 12
180
7
180
7
215
8,5
221
8,7
14 (31)
32 (71)
ZC17 24
180
7
287
11,3
235
9,3
406
16
20 (44)
38 (84)
ZC17 48
180
7
287
11,3
269
10,6
406
16
25 (55)
43 (95)
ZC17 80
356
14
356
14
370
14,6
406
16
56 (123)
95 (209)
ZC17 150
432
17
432
17
497
19,6
405
16
85 (187)
124 (273)
ZC17 250
400
15,7
400
15,7
675
26,6
568
22,4
141 (311)
180 (387)
Coriolis mass flow meters
MFM
The Satam mass flowmeter is used to measure the mass and density of viscous products such as heavy fuel oil, engine oil, bitumen or crude oil. Its excellent pressure resistance qualities combined with its straight tube design without any moving mechanical parts means it is capable of providing reliable and accurate measurements for liquid gases such as LPG.
Sectors of application
• Oil depots For product reception and at loading stations for trucks, wagons and ships
• Oil production Metering for transfers of products via pipeline
• Marine applications Loading and unloading of tankers
• Refineries Internal metering and control of manufacturing processes
• Fuel storage Metering of heavy fuel oil at mixer intake
Key points
> Direct measurement of mass Direct measurement without any correction for temperature or viscosity
> Reliability of measurements Strain gauges for correction of dilatation effects related to temperature changes
> Flexibility of installation Patented construction allowing the system to be supported by its own housing or on the inlet and outlet pipes
> Low maintenance costs Simple and robust design without any moving mechanical parts
> Direct measurement of density Identification of liquid being measured and detection of any change of product
Coriolis mass flow meters MFM
Technical specifications
Models
Mass flowrate Maximum flowrate (kg/h)
(kg/mn)
Minimum flowrate (kg/h)
(kg/mn)
Applications
Connection - Flanges Pressure class
Diameter
Materials Measurement tube
Secondary containment and flanges
Operating conditions Pressure
Viscosity
Liquid temperature
Ambient temperature
Pressure drop
Internal construction
Max. 100 mPa.s
-40 à +100°C
-40 to +60°C
1 bar (at maximum flowrate, 1 mPa.s)
Single straight tube
318L stainless steel
304 stainless steel
0 to 63 bar
Unrestricted
-40 à +150°C
MFM S
430 000
7 167
480
8
MFM T
Multi-product metering for low viscosity products Multi-product metering and measurement of density
150lbs RF (standard), 300lbs, 600lbs, 900lbs RF & RTJ (optional)
3/4” to 4”
Grade 9 titanium
Measurement tube Single straight tube (S50 and S80) Dual straight tube (S15, S25, S40)
Measurement converter MFC300
< ± 0.2% + zero stability Metrological performance Mass accuracy
Mass repeatability
Density accuracy
Temperature accuracy
Zero stability
< ± 0.1% + zero stability
< ±0.025% + zero stability
< ± 0.002 g/cm3 <± 0.0005 g/cm3 after on site calibration
± 0,5°C
< ± 0.025% of sensor max. flowrate < 0.008% of sensor max. flowrate sensor
Installation Straight inlet and outlet sections
Protection class
EX approval
Not necessary
IP 67, equivalent to NEMA 6
EEx d e [ib] IIC T6
Measuring range - Weight and dimensions
Measuring range
Min. flowrate Max. flowrate MFM 7000
(kg/h)
T15
T25
T40
T50/S50
T80/S80
1 125
3 450
9 150
18 000
43 000
Weight and dimensions
A
(mm)
102
115
169
219
273
B
(mm)
311
317
344
370
398
E
(mm)
548
700
925
1101
1460
Weight
(kg)
23
35
80
145
260
(kg/h)
11 250
34 500
91 500
180 000
430 000
MFM 1000
S15
S25
S40
S50
480
2 000
6 000
12 500
4 800
20 000
60 000
125 000
102
114
169
219
311
317
344
370
520
565
742
896
13,5
16,5
29,5
57,5
Turbine flowmeter
SA-LM-ZN
The Satam turbine flowmeter is primarily used for high-capacity metering. Its 500mm measurement tube can accurately measure at flowrates of over 3000 m3/h. Its excellent pressure and temperature resistance qualities means it is capable of providing reliable and accurate measurements for liquid gases such as LPG, as well as for cryogenic liquids. The SA model comes fitted with a straight-bladed rotor. It is intended for use with single-product low- viscosity applications.
The LM and ZN models come fitted with a two-bladed helical rotor. This construction ensures low sensitivity to variations in viscosity.
Sectors of application
• Marine applications Loading and unloading of tankers
• Oil production Metering for transfers of crude oil and condensate via pipeline
• Oil depots For product reception and at loading stations for wagons and ships
• Refineries Internal metering and control of manufacturing processes
Key points
> Low maintenance costs Simple and robust design with interchangeable mechanical components
> Stability of measurements Not sensitive to variations in pressure. Integrated flow straightener
> Wide range of uses Available for liquid and for gas from 10 l/h to 6 000 m3/h
Turbine flowmeter SA-LM-ZN
Technical specifications
Model SA
1,36 to 3 406 m3/h
6 to 15 000 USGPM
Single-product
Pressure class
Diameter
Materials Measurement tube & flanges
Bearings
Turbine rotor
Operating conditions Pressure
Viscosity
Liquid temperature
without preamplifier
With preamplifier
Internal construction Turbine rotor
Pulser
Preamplifier
Measurement chamber
Metrological performance Volume accuracy
Repeatability
Installation Straight sections
Protection class
EX approval
Inlet 10 DN / Outlet 5 DN
IP65
EEx ia IIC T6
Fixed
< 1 bar
Straight multi-blade
1 or 2
ANSI 150 to ANSI 1500 DN 25 to DN 300
1" to 12”
LM
3 to 300 m3/h
13 to 1320 USGPM
Single and multi-product
ANSI 150 ANSI 300 DN 50 to DN100
2" to 4”
316L stainless steel (other materials available on request)
ZN
0,012 to 6 000 m3/h
0,05 to 26 400 USGPM
Single and multi-product
ANSI 150 to ANSI 2500 DN10 to DN 500
1/2" to 20”
Flow rate
Application
Connection - Flanges
Ceramic, tungsten carbide
304 L stainless steel
0 to 200 bar
0,1 to 10 cSt
-270 to +230°C
Graphite, tungsten carbid
Aluminium / Titanium (optional)
0 to 40 bar
0,1 to 15 cSt
-40 to +180°C
-20 to 80°C
< 1 bar
Helical twin-blade
2
Optional
Removable
< ± 0.15%
< ± 0.02%
Inlet 0 DN / Outlet 0 DN
IP65
EEx ia IIC T6 and EEx d ia II C T6
Graphite, tungsten carbid
Aluminium / Titanium (optional)
0 to 420 bar
0,1 to 1000 cSt
-40 to +180°C
< 0,8 bar
Helical twin-blade
2
Removable
Inlet 10 DN / Outlet 5 DN
IP66
EEx ia IIC T6 and EEx d ia II C T6
Measuring range
SA model
Nominal diameter Min. flowrate
m3/h
1/2” 1” 1”1/2 2” 2”1/2 3” 4” 6” 8” 10” 12” 14” 16” 18” 20”
- 1,36 2,95 5,1 40 65 28,4 65,9 118 182 273 - - - -
USGPM
Max. flowrate
m3/h
- 13,6 29,5 51 400 650 284 659 1180 1820 2730 - - - -
USGPM
LM model
Min. flowrate
m3/h
- - - 3 - 5 30 - - - - - - - -
USGPM
Max. flowrate
m3/h
- - - 30 - 50 300 - - - - - - - -
USGPM
ZN model
Min. flowrate
m3/h
0,012 0,2 0,8 3 - 7 20 40 80 120 240 350 400 480 600
USGPM
0,053 0,88 3,52 13,2
30,8 880 176 352 528 1056 1541 1760 2113 2642
Max. flowrate
m3/h
0,12 2 8 30 - 70 200 400 800 1200 2400 3500 4000 4800 6000
USGPM
0,53 8,8 35,2 132
308 8800 1760 3520 5280 10560 15410 17600 21130 26420
6 13 22,4 176 286 125 290 520 801 1202
60 130 224 1760 2860 1250 2900 5200 8010 12020
13,2
22 132
132
220 1320
Ultrasonic flowmeter
UFM III
The Satam ultrasonic flowmeter is used for measuring refined petroleum liquids. It is capable of measuring high-pressure fluids such as LPG or any other liquid gas. Its measurement tube without any intrusive elements or moving mechanical parts results in very little pressure drop and nearly no maintenance costs at all. Because of the measurement method used, ultrasonic flowmeters are available in diameters of up to 40 inches and provide exceptional accuracy of measurement.
Sectors of application
• Transport of petroleum products via pipeline Metering stations, leak detection
• Oil depots For product reception and at loading stations for wagons and ships
• Marine applications Loading and unloading of tankers
• Chemical industry Metering stations for non-corrosive liquids
Key points
> Minimum pressure drop Measurement tube of same diameter as the flanges No intrusive element
> Low maintenance costs Totally static measurement system No need for filtering
> Exceptional reliable measurements Three-channel redundant configuration for measurement validation
> Easy installation Bi-directional measurement Reduced weight in a compact design
Ultrasonic flowmeter UFM III
Technical specifications
Model
Flow rate
Application
Connection - Flanges Pressure class
Diameter
Material Flanges, measurement tube, housing
UFM III
7 to 29 200 m3/h / 30 to 128 550 USGPM
Single-product metering
150lbs RF (standard), 300lbs, 600lbs, 900lbs RF & RTJ (optional)
2’’ to 40’’
316L stainless steel (other materials available on request)
Operating conditions
Operating pressure
Liquid temperature
Ambient temperature
Viscosity
Pressure loss (1 cSt, Qmax)
Internal construction Ultrasound transmitters
Measurement lines
Metrological performance Measured parameter
Volume accuracy
Repeatability
Installation Straight sections
Protection class
EX approval
0 to 63 bar
+25 to +140°C
-40 to +70°C
0,1 to 10 mPa.s
< 0.1 bar
Windows incorporated into wall of measurement tube
3 parallel channels
Actual volume
< ± 0.15%
< ± 0.02%
Inlet 10 DN / Outlet 5 DN
IP 66, equivalent to NEMA 4/4X/6 to IEC 529
EEx d [ib] II C T6 and EEx d e [ib] II C T6
Measuring range - Weight and dimensions
Measuring range Nominal diameter Min. flowrate Max. flowrate
(m3/h)
2”
3”
4”
6”
8”
10”
12”
14”
16”
18”
20”
24”
28”
32”
36”
40”
7
16
29
66
117
182
263
358
467
591
730
1051
1430
1868
2364
2919
Weight and dimensions
a
(mm)
290
330
380
440
600
640
710
770
830
900
950
Di
(mm)
49,2
73
97,2
154,1
202,7
254,4
304,7
336,5
387,3
438,1
484
W
(mm)
150
200
220
270
370
420
470
500
550
600
650
T
(mm)
345
380
412
466
523
582
645
687
744
788
845
Weight
(kg)
14
26
33
45
72
105
145
179
221
256
335
(m3/h)
73
164
292
657
1167
1824
2627
3575
4670
5910
7297
10507
14301
18679
23641
29196
•
Oil transport chain
Satam meters
for oil transport chain
• : Ideally suited • • : Suitable subject to certain conditions
PD meter
Mass flowmeter
Turbine flowmeter
Ultrasonic flowmeter
Metering station for crude oil on pipeline •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Loading and unloading station for crude oil tankers
Loading and unloading station for crude oil tanker wagons
Refining and intermediary storage
Road tanker loading station
Delivery of domestic fuel oil by road tanker
Aircraft refuelling
•
By liquid
Type of liquid
Premium grade fuel, gasoline
Ethanol
Diesel
Fatty Acid Methyl Ester (FAME)
Kerosene
Bio-diesel
E5...E85
Heavy fuel oil
Bitumen
Pitch
LPG
LNG
Light crude oils
Condensates
Industrial oils
Flowmeter selection table
• : Ideally suited • • : Suitable subject to certain conditions
PD meter
Mass flowmeter
Turbine flowmeter
Ultrasonic flowmeter
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
By applications
Type of application
Truck loading station
Wagon loading/unloading station
Tanker loading/unloading station
Aircraft refuelling
On-board metering for road tankers
Preparation and metering of bio-fuels
Metering for light crude oil on pipeline
Metering for condensate on pipeline
Multi-product metering on pipeline
Product identification on multi-product pipeline
Control of mixer flowrate for preparation of maritime fuel oils
PD meter
Mass flowmeter
Turbine flowmeter
Ultrasonic flowmeter
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Worldwide Sales
• Headquarters - Sales Department 5, rue des Chardonnerets BP 45 027 Tremblay 95 912 Roissy Charles de Gaulle Cedex FRANCE Tél. : +33 (0)1 49 90 77 00 Fax : +33 (0)1 49 90 77 99 E-mail : [email protected] Website : www.tokheim-satam.com
• Manufacturing facility 14, avenue de Verdun BP 129 14700 Falaise Cedex FRANCE Tél. : +33 (0)2 31 41 41 41 Fax : +33 (0)2 31 40 75 61
• Headquarter
• Manufacturing facility
• Subsidiary
• Representative office
• Agents
As Tokheim regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
BO42 - GB - RO - 02/08 - Marketing Communication Tokheim Group SAS - Marketing SATAM - Création & Impression : DARMON IMPRESSIONS