flowIQ® 3101D A T A S H E E T

� Ultrasonic measurement

� Pinpoint accuracy

� Longevity

� Long range

� Leak detection

� Vacuum-sealed construction

� Lead-free and certified to NSF/ANSI61

Ultrasonic measurement flowIQ® 3101 measures cold water consumption in multi-unit and com-mercial buildings.

Ultrasonic flow measurement guarantees pinpoint accuracy and longevity. Ultrasonic flow measure-ment is based on the transit time method and all measurements, references, readings, calculations and data communication are controlled by an advanced, specially designed, electronic circuit. Thus, the meter has no moving parts, which makes flowIQ® 3101 resistant to wear and impurities in the water.

Long rangeTo meet increasing market demands for smart metering flow IQ® 3100 comes with the newest radio tech-nology, including integrated 915 Mhz band RF which complies with Part 15 of the FCC Rules and enables remote reading of consump-tion data. Consumption data can also

be read manually directly from the display or by an optical eye.

The long range antenna transmits high-power radio signal with intelli-gent coding - which can be read from a long distance with ‘drive-by’.

Leak detectionflowIQ® 3101 includes leak detection. This means that the utility and the consumer can quickly discover and repair costly leaks while avoiding further water loss.

Construction The meter is hermetically closed and vacuum-sealed to prevent humidity from reaching the electronics and avoid condensation between the glass and display. The meter is IP68 (submersible) type tested and suit-able for installation in meter pits.

An internal lithium battery, powers the meter and guarantees the me-ter’s total longevity.

Lead-free and certified to NSF/ANSI61 The meter housing is made of plastic material polyphenylene sulfide (PPS) and is mounted on a measuring part made of stainless steel. The meter can be installed vertically or horizon-tally and quickly mounted independ-ent of existing piping and installation conditions.

The unique combination of flowIQ® 3101 features reduces cur-rent operating costs to measure wa-ter usage and minimizes unexpected expenses in connection with possible leakage.

Electronic ultrasonic meter for cold residential water

Kamstrup Water Metering LLC · 1040 Crown Pointe Pkwy Ste. 320 · Atlanta, GA 30338 · Tel: +1 (404) 835-6716 · [email protected] · www.kamstrup.com

flowIQ® 3101D A T A S H E E T

2 58101228_D1_US_12.2014

Contents

General description 3

Material 4

Tecnical data 4

Meter sizes 5

Meter details 6

Encoded output 7

Measurement of temperatures 8

Display and information codes 10

Data registers 11

915MHz band RF– wireless radio communication 12

Pressure loss 14

Ordering details 15

Configuration 16

Dimensioned sketches 17

Accessories 20

flowIQ® 3101D A T A S H E E T

358101228_D1_US_12.2014

DimensionSketch4WEIGHT:

A3

SHEET 1 OF 1SCALE:1:5

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

General description

flowIQ® 3101 is a series of integrated water meters intended for consumption and distribution measurement of cold residential water in large multi-unit and commercial buildings. The meter fits perfectly into a network of flowIQ® 2100 household meters.

flowIQ® 3101 is a static water meter based on the ultrasonic principle. The water meter has been developed on the basis of Kamstrup’s experience since 1991 with the development and production of static ultrasonic meters.

This technology has many advantages, including no moving parts so the meter is unaffected by parti-cles in the water and measures consistently throughout its lifetime.

flowIQ® 3101 has been subjected to a comprehensive set of tests to meet AWWA standards and is certified to NSF/ANSI61.

flowIQ® 3101 is constructed as a vacuum chamber of molded composite material, which is mounted on a measuring tube of stainless steel. Thus, the electronics are fully protected against penetration of water, both from medium pipes and the environment. The meter is IP68 rated for submersible envi-ronments. Hence, the meter is specially suited for small pump stations and distribution wells, as well as meter pits, which are frequently filled with water.

The volume is measured using bidirectional ultrasonic technique based on the transit time method, proven a long-term stable and accurate measuring principle. Two ultrasonic transducers send sound signals with and against the flow, respectively. The ultrasonic signal traveling with the flow reaches the opposite transducer first. The time difference, between the two signals, can be converted into flow velocity and thereby the volumetric flow rate can be calculated.

The accumulated water consumption is displayed by flowIQ® 3101 in gallons, or cubic feet with nine digits and up to three decimals. The display has been specially designed to obtain long lifetime and sharp contrast in a wide temperature range.

In addition to volume reading, a number of information codes are displayed. The meter also measures ambient temperature continuously, storing minimum, mean and maximum temperatures daily.

All registers are saved daily in the meter memory for 460 days. Monthly data for the latest 36 months are also saved.

flowIQ® 3101 comes with integrated 915MHz band RF radio

flowIQ® 3101 is fitted with an optical eye, which makes it possible to read consumption data and information codes, stored in the meter’s data logger. The optical eye gives access to configure the meter.

The water meter is powered by an internal lithium battery.

Placement in prolonged direct sunlight must be avoided.

The meter can and may only be opened by Kamstrup Headquarters. If the meter has been opened, and the sealing has thus been broken, the meter is no longer valid for billing purposes. Furthermore, the factory waranty no longer applies.

The ultrasonic principle

Characteristics:• ultrasonic metering• accurate and reliable• low start and stop flow • no moving parts• no wear • large clear display• multiple info codes• long-term stable• long life• powered by a lithium battery• hermetically sealed • fully waterproof• suitable for mounting in pits.

flowIQ® 3101D A T A S H E E T

4 58101228_D1_US_12.2014

Wetted partsFlow part, threaded Stainless Steel 316

Flow part, flanged Stainless steel 316

O-ring EPDM

Measuring tube PPS with glass fiber

Reflectors Stainless steel, 304L, 316, 316L

External meter partsMeter housing Polyphenylene sulfide (PPS)

Cover Glass

Top ring (sealing) Polycarbonate (gray)

Material

Tecnical data

Electrical dataBattery 3.65 VDC, 1 C cell lithium

Mechanical dataAmbient temperature 35 °F...130 °F

Protection class IP68-rated (waterproof-submersible)

Fluid temperature 33...85 °F

Storage temp. empty meter -10 °F...140 °F

Max. operating pressure– Thread mounted 250 PSI (17 bar)– Flange mounted 250 PSI (17 bar)

flowIQ® 3101D A T A S H E E T

558101228_D1_US_12.2014

flowIQ® 3101 is available in the following combinations:

*) Encoded output – avaiable for all meter sizes (03U-20-C0X-8XX)

Tecnical data

Meter sizes

Type number *) Meter size

Max. flow for continuous operation

Start flow Min. flowTransition

flowPressure

loss at max flowConnection

on meter

Lay

Length

GPM (3) GPM (S) GPM (1) GPM (2) PSINPSM

thread/flange

Inches /(mm)

03U-56-C02-8XX 1” 55 0.04 0.25 0.4 4.0 5/4” thread 10 ¾ “ /(273)

03U-56-C04-8XX 1½” 120 0.06 0.4 1.2 8.0 1½” thread 12 5/8 “ /(321)

03U-56-C06-8XX 1½” 120 0.06 0.4 1.2 8.0 1½” flange 13” /(330)

03U-56-C07-8XX 2” 160 0.1 0.5 1.5 2.0 2” thread 15 1/4 “ /(387)

03U-56-C08-8XX 2” 160 0.1 0.5 1.5 2.0 2” flange 17” /(432)

100

101

102

103

104

105

106

99

98

97

96

95

94

s 1 2 GPM

S: Start �ow / low �ow cut-o�1: Min. low �ow2: Low �ow / transition �ow3: Max. �ow for continuous operation and max. �ow

extended low �ow rangeleak �ow detection

normal �ow range

3

AccuracyMPE (maximum permissible error)

According to AWWA C-708

± 3 % in extended low flow range

± 1.5 % in ‘normal flow’ range

flowIQ® 3101D A T A S H E E T

6 58101228_D1_US_12.2014

Meter details

Meter information in permanent laser engraved text.

Optional customer label, water company logo , serial no, etc. (15x38 mm available)

Bar code with serial number

Temperature range

Nominal Meter size - Max. flow for continous opera-tion

Software version

FCC identification

IP68 (Waterproof/ sub-mersible)

Optical eye for reading and configuration

Type number (includes information on meter size, overall length, etc.)

Configuration of the adjustable parameters

Serial number and production year

flowIQ® 3101D A T A S H E E T

758101228_D1_US_12.2014

Encoded output

General description Encoded Output is compatible with a number of RF network systems. The systems consist of a number of endpoints, each of these is electrically connected to a meter. Each endpoint sends RF to a collector.

Encoded output is specified by the type number: 03U-20-C0X-8XX.

CableLength of cable is 5 feet – corresponds to approx. 1.5 metres

EndpointsEncoded Output can emulate data protocols for the following end points:

Encoded OutputThe meter can emulate a number of meters:

Telegram name Telegram no. Content Length

Sensus 9-digit #1 Volume (9 digits), serial number 25 * 10 bits

Sensus 6-digit #2 Volume (6 digits), serial number 22 * 10 bits

Neptune E-Coder #4 Volume (8 digits), serial number, info codes 34 * 11 bits

Provider/Telegram Endpoint

Sensus 9-digit Itron 100W

Sensus 6-digit

Itron - 60WMueller HotrodBadgerKP

Neptune E-coder R900

flowIQ® 3101D A T A S H E E T

8 58101228_D1_US_12.2014

Measurement of temperatures

Temperature monitoringflowIQ® 3101 measures the ambient temperature. The measurements can be used to monitor the installation and to provide an indication of the ambient conditions.

Temperatures are logged in the daily and monthly records.

Minimum, mean and maximum values are logged daily. The register contains the last 460 days.

On the first day of each month the minimum, maximum and average temperatures, recorded in the past month, are stored in the register. The register stores the last 36 months of values.

Temperature values are referred to in Fahrenheit and can be read via the optical eye and send by the Wireless M-Bus radio signal. Optional temperature combinations in the radio package are described in the section ’Optional data in data logger’.

Ambient temperaturesMonitoring the ambient temperature of the installation can be used as a warning of freezing temperatures or unintended high temperatures. The measurement in the meter housing corresponds to the ambient temperature where the meter is installed.

The temperature is measured every minute. The maximum and minimum values are calculated based on a 2 minutes averaging value. The average temperature is a time-weighted mean value.

Consumption valuesBesides readout of the current total registered water use the meter saves a number of other consumption data.

Following values can be send via the Wireless M-Bus radio signal:

· Target Volume - ie meter reading the first day of the month

· Maximum flow - daily

· Maximum flow - monthly

· Selected values of ambient temperature.

flowIQ® 3101D A T A S H E E T

958101228_D1_US_12.2014

Ambient temperature

Consumption values

Data collection

Average daily

Monthly target volume

R-value

Maximum flow daily

Minimum month

Maximum month

Monthly target volume

Drive-by

3

9

5

7

Measurement of temperatures

Optional registers in data loggerSome of the data sent via the Wireless M-Bus radio is optional. It is possible to select one data package; content is illustrated below. The choices are determined by means of the selected R-value when ordering a water meter, as shown to the right in the figure.

flowIQ® 3101D A T A S H E E T

10 58101228_D1_US_12.2014

Display and information codes

flowIQ® 3101 can be read from the large, easily readable, specially designed display. Nine large fig-ures indicate gallons or cubic feet. The last three figures may indicate decimals.

The information codes in the display have the following meaning and function:

Info code flashes in the display

Meaning

FLOW Indicates water flow through the meter. If there is no flow, the text will be off. This text is not flashing

LEAK The water has not been stagnant in the meter during the last few days.This can be a sign of a leaky tap or toilet.

BURST The water flow has exceeded a preprogrammed limit for a minimum of 30 minutes which is a sign of a burst pipe.

TAMPER Attempt of fraud. The meter is no longer valid for billing.

Gal / ft3 / m³ Consumption is indicated in gallons, cubic feet or cubic meters

VERIFIC Will always be off when the meter is in operation - text will be on during factory control and verification of the meter.

DRY The meter is not water-filled. In this case nothing will be measured.

REVERSE The water flows through the meter in the wrong direction.

RADIO OFF The meter is still in transport mode with the built-in radio transmitter turned off. The transmitter turns on automatically when the first quarter gallon of water has run through the meter.

Squared ‘dot’ One small square flashing indicates that the meter is active.

‘A’ followed by a number Change log

Indicates the number of metrologic changes the meter has gone through after factory verification. If no adjustments have been made both the A symbol and the digit are inactive

Information codes ‘LEAK’, ‘BURST’, ‘DRY’ and ‘REVERSE’ switch off automatically when the conditions that activated them no longer exist. In other words, ‘LEAK’ disappears when the water is stagnant; ‘BURST’ disappears when the consumption falls to normal level; ‘REVERSE’ disappears when the water no longer flows in the wrong direction; ‘DRY’ disappears when the meter is filled with water.

flowIQ® 3101D A T A S H E E T

1158101228_D1_US_12.2014

Data registers

flowIQ® 3101 has a permanent memory (EEPROM), in which the values of various data loggers are saved.

The meter includes the following registers:

Data logging interval Data logging depth Logged value

Monthly logger 36 months See table below

Daily logger 460 days See table below

Info logger 50 events Info code, meter reading and date

Thus, it is always possible to read target volume and information codes for each of the latest 36 months as well as corresponding meter reading and possible information codes for each of the latest 460 days. The loggers can only be read via the meter's optical eye.

The monthly logger is written on the first day of the month, the daily logger is written at midnight. The following registers are logged:

Every time the information code changes, date and information codes are logged. Thus, it is possible to read the latest 50 changes of the information code as well as the date the change took place. Read-ing is only possible via the optical eye.

Register type Description Monthly logger, 36 months

Daily logger, 460 days

Date (YY.MM.DD) Logging time, year, month and day • •

Volume Current meter reading (legal) • •

Operating hour counter Accumulated number of operating hours • •

Info Information code • •

Vol Reverse Volume during reverse flow • –

Date of max. flow Date stamp of max. flow during period • –

Max. flow, V1 Value of max. flow during period • •

Date of min. flow, V1 Date stamp of min. flow during period • –

Min. flow V1 Value of min. flow during period • •

Min. temp. Meter temperature – minimum • •

Max. temp. Meter temperature – maximum • •

Medium temp. Meter temp. – time weighted average • •

flowIQ® 3101D A T A S H E E T

12 58101228_D1_US_12.2014

915MHz band RF– wireless radio communication

flowIQ® 3101 communicates via a high-power antenna and integrated 915MHz band RF, which gives access to easy and fast wireless reading of the meter.

The integrated 915MHz band RF transmits a data package every 16 seconds. In order to obtain long battery lifetime, the data package has been compressed and includes only the most important meter readings.

By connecting Kamstrup USB Meter Reader to an antenna on the roof of the car, the meter can be read via ‘drive-by’.

The following details are transmitted:

• Current meter reading

• Optional register combination of:

Target volume – monthly / max. flow / ambient temperature

• List of active information codes

• List of information codes which have been active within the latest 30 days

The list of information codes, which have been active, also includes information on how long they have been active.

915MHz band RF is an open standard, following en13757-4 : 2010, which means that while the flowIQ® 3101 can be configured with or with-out encryption of the transmitted signal, encryption is required in the United States.

Encryption protects personal data against unauthorized monitoring. Furthermore, the encryption file provides easy access to import meter data for reading programs.

flowIQ® 3101 can now also be read by using for example the ’READy’ – Kamstrup’s mobile app – which is ideal for ’walk-by’ and ’drive-by’ reading.

Below is a screen shot of how a reading may appear on the user’s smart phone.

flowIQ® 3101D A T A S H E E T

1358101228_D1_US_12.2014

915MHz band RF– wireless radio communication

Below an example of the graphics from READy Manager program on the PC.

flowIQ® 3101D A T A S H E E T

14 58101228_D1_US_12.2014

Pressure loss

According to AWWA standards the maximum pressure loss must not exceed 15 PSI at safe maximum operating capasity. The pressure loss in a meter increases with the square of the flow and can be stated as:

Q=kv x √∆p

where:

Q = volume flow rate GPM

kv = volume flow rate at 1PSI pressure loss

∆p = pressure loss PSI

Graph GPM Size

kv Theoreticalflowrate at 15 PSI

GPM

A 55 5/4” 28 110

B 120 1 1/2” 42 160

C 160 2“ 117 450

flowIQ® 3101D A T A S H E E T

1558101228_D1_US_12.2014

Ordering details

Start your order by stating the type number of the selected model of flowIQ® 3101. The type number includes information on meter type, meter size, overall length, communication, country code etc.

Some of the features included in the type number cannot be changed.

Subsequently the meter configuration, which determines customer specific requirements such as number of digits in display etc., is selected. The configuration is completed during programming of the final meter.

Finally, required accessories, if any, like e.g. gaskets, are selected.

Accessories are enclosed separately to be mounted by the installer.

Communication

915 MHz US 56

Encoded Output 20

Supply

Battery (C-cell) C

Meter size

GPM ConnectionLength

[inches/mm]

55 1” / 5/4” thread 10 ¾” / 273 2

120 1½” / 1½” thread 12 5/8” / 321 4

120 1½” / 1½” flange 13” / 330 6

160 2” / 2 “ thread 151/4 “ / 387 7

160 2” flange 17” / 432 8

Meter type

Cold water meter 8

Time zone

Eastern UE

Central UC

Mountain UM

Pacific UP

flowIQ® 3101 Type 03U 0

flowIQ® 3101D A T A S H E E T

16 58101228_D1_US_12.2014

Configuration

Unless otherwise stated in the order, Kamstrup supplies the following:

Target date 01

Average time of max. values - 2 minutes 002

Customer label 2005 -MMM MMM

Leakage message limit

Continuous GPH for 24 hours – for meter size: 1” 1½” 2”

OFF -- -- -- 0

Flow continuously > 0.5% of max. flow 17 36 48 1

Flow continuously > 1.0% of max. flow 33 72 96 2

Flow continuously > 2.0% of max. flow 66 144 192 3

Flow continuously > 0.25% of max. flow 8 18 24 4

Flow continuously > 0.1% of max. flow 3 7 10 5

Pipe burst limit

Total gallons within 30 minutes – for meter size: 1” 1” 1½” 1½ 2”

OFF -- -- -- 0

Flow > 5% of max. flow for 30 minutes 83 180 240 1

Flow > 10% of max. flow for 30 minutes 165 360 480 2

Flow > 20% of max. flow for 30 minutes 330 720 960 3

Optional register in data logger

Monthly target volume and daily average meter temperature 3

Monthly target volume and monthly minimum meter temperature 5

Monthly target volume and monthly maximum meter temperature 7

Max flow last day and daily average meter temperature 9

Display resolution (unit of measure)

000000.001 m3 0

000000001 Gal 1

00000000.1 Gal 2

0000000.01 Gal 3

000000001 ft3 5

00000000.1 ft3 6

0000000.01 ft3 7

000000.001 ft3 8

Encryption level

No encryption (not available - encryption is required in the US) 0

Encryption with separately forwarded key 3

01 002 000 2 3 5 1 3

KK LLL MMM N P R S T

flowIQ® 3101D A T A S H E E T

1758101228_D1_US_12.2014

Dimensioned sketches

13”

Type: 6 - GPM 1201½” / 1 ½” x 13” (330 mm)

10 ¾”

Type: 2 - GPM 551” / 5/4” x 10 ¾” (273 mm)

12 5/8”

Type: 4 - GPM 1201½” / – TBD – x 12 5/8” (321 mm)

flowIQ® 3101D A T A S H E E T

18 58101228_D1_US_12.2014

17”

Type: 8 - GPM 1602” / 2” x 17” (432 mm)

151/4”

Type: 7 - GPM 1602” x 151/4” (387 mm)

Dimensioned sketches

flowIQ® 3101D A T A S H E E T

1958101228_D1_US_12.2014

L

H

B

Målskitse10m3_3D_dimensionsWEIGHT:

A4

SHEET 1 OF 1SCALE:1:5

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

MATERIAL:

DATESIGNATURENAME

DEBUR AND BREAK SHARP EDGES

FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:

Q.A

MFG

APPV'D

CHK'D

DRAWN

Dimensioned sketches

GPM Connection L

H

h A C d Weight approx.

[Lbs]

Meter type

55 5/4” thread10 ¾”

/ 273 mm3.7”/ 95

-- -- -- -- 4.1 2

120 – TBD –12 5/8”

/ 321 mm3.9”

/ 100-- -- -- -- 6.0 4

120 1½” flange13”

/ 330 mm4.3”

/ 1223.6 / 92

4.0/102

5.7/146

0,79/ 20

13 6

160 2” thread15 1/4” / (387)

4.33”/110

-- -- -- -- 9.2 7

160 2” flange17”

/ 432mm

5.31” /135

5.3/146

4.13”/ 105

4.49”/ 114

6.54/ 166

0,79 / 20

19 8

L

H

h

Dimensions: [Inches / mm]

d

3.61/ 91.6

A

H

C

3.61/ 91.6

L (for meter type 6 and 8)

flowIQ® 3101D A T A S H E E T

20 58101228_D1_US_12.2014

Accessories

See Accessories for Water Meters: 5810-1270