flow configuration software getting started

16
User’s Manual FSA120 Flow Configuration Software Getting Started IM 01C25R51-10E IM 01C25R51-10E 8th Edition CONTENTS PART A (English version) 1. Components 2. To Start with 3. Installation Flow 4. Important Notice on Flow Configuration Wizard 5. Software Version 6. Information Provision Web Site Appendix A Flow Parameters Download Procedure Appendix B Flow configuration for EJX910A/EJX930A HART 7 model PART B (Japanese version) (和文版の簡易スタートマニュアルが記載されています) Revision Information R1.05

Upload: others

Post on 12-Feb-2022

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Flow Configuration Software Getting Started

User’sManual FSA120

Flow Configuration SoftwareGetting Started

IM 01C25R51-10E

IM 01C25R51-10E8th Edition

CONTENTSPART A (English version)

1. Components2. To Start with3. Installation Flow4. Important Notice on Flow Configuration Wizard5. Software Version6. Information Provision Web SiteAppendix A Flow Parameters Download ProcedureAppendix B Flow configuration for EJX910A/EJX930A HART 7 model

PART B (Japanese version)(和文版の簡易スタートマニュアルが記載されています)

Revision Information

R1.05

Page 2: Flow Configuration Software Getting Started

<A1. Header> 2

IM 01C25R51-10E

PART AThank you for purchasing FSA120 Flow Configuration Software.This document is intended to guide users what to do after receiving the software package.Please carefully read this document first when you receive the package and follow the instructions.

1. Components The following picture shows the items included in the FSA120 package.

FieldMate (bundled)

CD-ROM DVD-ROM

FieldMate

CD-ROM

FlowNavigator

FSA120

USB FieldMate Modem (Option)

Device Files

License NumberSheet

FieldMate

Paper Document

FieldMate

License NumberSheet

FlowNavigator

Disc No.1

Disc No.3

Disc No.2 License Sheet No.1 Document No.1 and No.2

License Sheet No.2

Paper Document

FlowNavigator

Document No.3 and No.4

F01E.ai

FlowNavigator

Figure 1 Components of FSA120

Each disk contains the following software.

● CD-ROM/DVD-ROM: 3 discs(1) FieldMate <Disc No.1>(2) Device Files (Includes Device DTM*) <Disc No.2> *: Device DTM is delivered by Yokogawa DTMLibrary HART/FOUNDATION fieldbus(3) FlowNavigator (Includes FlowNavigator Program and Resource) <Disc No.3>

● License Sheet: 2 sheets(1) FieldMate License Number Sheet (Basic or Advance, as specified in order) <License Sheet No.1>(2) FlowNavigator License Number Sheet <License Sheet No.2>

● Paper Document: 4 sheets(1) FieldMate Getting Started (IM 01R01A04-01E) <Document No.1>(2) FieldMate Operational Precaution (IM 01R01A01-91E) < Document No.2>(3) FlowNavigator Getting Started (IM 01C25R51-10E) < Document No.3>[This document](4) FlowNavigator License Agreement <Document No.4>

● USB FieldMate Modem (Option)

Page 3: Flow Configuration Software Getting Started

<A1. Header> 3

IM 01C25R51-10E

NOTEFor FSA120 R1.04 or later, the product name has been changed to “FieldMate FlowNavigator” because the DYFMVTool program for digitalYEWFLO Vortex Flowmeter has been added.Consequently, the following items have been renamed accordingly:<Disc No.3>: EJXMVTool Additional resource disk → FlowNavigator CD-ROM<License Sheet No.2>: EJXMVTool License Number Sheet → FlowNavigator License Number Sheet<Document No.3>: EJXMVTool Read Me First → FlowNavigator Getting Started<Document No.4>: EJXMVTool License Agreement → FlowNavigator License Agreement.

NOTEThe location of following software has been changed for FSA120 R1.04 or later.• Device Files DVD-ROM <Disc No.2>:FlowNavigator program has been moved from Yokogawa DTMLibrary HART/FOUNDATION fieldbus in Device Files DVD-ROM to FlowNavigator CD-ROM

• FlowNavigator CD-ROM <Disc No.3>:In addition to Resource, the FlowNavigator program (EJXMVTool and DYFMVTool) has been added.

2. To Start with1) FlowNavigator is the software utilizing FDT/DTM technology. To use this software, a frame application is required. ‘Field

Mate’ is bundled with this software package as Yokogawa standard frame application. The quality and operability of FlowNavigator is certified for use with FieldMate only. Please use ‘Field Mate’ as frame application. Also, you can use Field communication server included in FieldMate as a Communication DTM. For the installation and operation of FieldMate, please refer to the printed document

• “FieldMate Getting Started” (IM 01R01A04-01E) < Document No.1> • “FieldMate Operational Precaution” (IM 01R01A01-91E) < Document No.2> For the details of installation and operation, please also refer to the user’s manual of FieldMate in pdf format shown by start

menu.

2) Before starting any operation, please carefully read the instructions in the user’s manual of FlowNavigator and obtain nec-essary knowledge about installation and operation of the software. The User’s manual “FSA120 Flow Configuration Software” (IM 01C25R51-01E) is provided as a Portable Document For-mat (pdf) file in the CD-ROM labeled “FlowNavigator”, and is located at <FlowNavigator CD-ROM>: \EJXMVTool_Manual.pdf

<FlowNavigator CD-ROM>: \DYFMVTool_Manual.pdf Set the FlowNavigator CD-ROM in the CD-ROM drive of your computer and double click the name of the file.

To read the file in pdf format, Adobe Reader is required. If Adobe Reader is not on your PC, download and install Adobe Reader from the following website. <http://www.adobe.com/>

Page 4: Flow Configuration Software Getting Started

<A1. Header> 4

IM 01C25R51-10E

3. Installation FlowFollowings are the flow of standard installation. As the procedures may differ according to the condition, please find details in each designated manual and follow the instructions.

Step 1 Confirm incompatible software does not exist, PRM and FSA210 (Refer to < Document No.2>)

Step 2 Install communication device software (For FOUNDATION fieldbus communication)

Step 3 Install FieldMate (Refer to <Document No.1>)

1) Install FieldMate <Disc No.1 > 2) Enter the license number of FieldMate <License Sheet No.1 > 3) Install Device Files <Disc No.2 >

Step 4 Install FlowNavigator <Disc No.3 >

Step 5 Start FieldMate

1) Register yourself in FieldMate (Refer to <Document No.1>) 2) Start Device DTM

Step 6 Start FlowNavigator Program

1) Enter the license number of FlowNavigator <License Sheet No.2 >

4. Important Notice on Flow Configuration Wizard● Supplemental explanation regarding Apply button When you click the Apply button, the flow parameters are temporarily saved to an offline database on your PC. To down-

load the flow parameters to the device, set “Download to Device” in the Offline Parameter screen. For basic information on the procedure for downloading flow parameters to the device, refer to Appendix A.

● Supplemental explanation for EJX910A/EJX930A HART 7 model Flow parameter configuration by FlowNavigator can be done by “EJX910 V2.1” DTM.

Refer to Appendix B.

Page 5: Flow Configuration Software Getting Started

<A1. Header> 5

IM 01C25R51-10E

5. Software VersionFollowing is the information of the software version of the package and each software included in the package. For the latest information of software version/revision, please see the web site of FieldMate.For how to confirm version/revision of the software, please refer to the subsection 4.2.6 of IM 01C25R51-01E.

FSA120package

AdditionalResource Disk FieldMate

YokogawaDTM Library

(Device Files*)EJX910DTM

R1.02.00 R1.02.00 R1.02.10 HART 2006-3FOUNDATION fieldbus 2006-1

HART EJX910V1.1 1.4.124.19FOUNDATION fieldbus EJX910V1.2 1.1.15.14

R1.02.01 R1.02.01** R1.02.10 HART 2006-3FOUNDATION fieldbus 2006-1

HART EJX910V1.1 1.4.124.19FOUNDATION fieldbus EJX910V1.2 1.1.15.14

R1.02.02 R1.02.02 R1.03.00 HART 2008-1FOUNDATION fieldbus 2008-1(R1.01.00)

HART EJX910V1.1 1.4.124.16FOUNDATION fieldbus EJX910V1.2 1.2.64.89

R1.03.00 R1.03.00 R2.01.00 HART 2008-3FOUNDATION fieldbus 2008-3(R2.01.00)

HART EJX910V1.1 1.4.124.16FOUNDATION fieldbus EJX910V1.2 1.2.81.108 EJX910V2.1 1.2.81.108

FSA120package

FlowNavigatorDisk FieldMate

YokogawaDTM Library

(Device Files*)Device DTM

R1.04.00 R1.04.00 R2.02.00 HART 2010-1FOUNDATION fieldbus 2010-1(R3.01.00)

EJX910 HART: EJX910V1.1 1.4.124.16 EJX910V2.1 1.4.160.18EJX910 FOUNDATION fieldbus: EJX910V1.2 1.2.81.108 EJX910V2.1 1.2.81.108DYF(SoftDL) FOUNDATION fieldbus: DYF(SoftDL) V3.1 1.2.81.108

R1.05.00 R1.05.00 R2.04.00 HART 2011-3FOUNDATION fieldbus 2011-4(R3.03.00)

EJX910 HART: EJX910V1.1 1.4.124.16 EJX910V2.1 1.4.160.27EJX910 FOUNDATION fieldbus: EJX910V1.2 1.2.81.108 EJX910V2.1 1.2.81.108DYF(SoftDL) FOUNDATION fieldbus: DYF(SoftDL) V3.1 1.2.81.108

*: Compatibility between FieldMate and Device Files is indicated at the following URL. https://voc.yokogawa.co.jp/PMK/Top.do

**: The version number on the CD-ROM shows R1.02.01. On the other hand, the version number on the “Add/ remove program” screen of Windows Control Panel remains to show R1.02.00 even if the update files are installed.

To confirm whether the latest EJXMVTool R1.02.01 is correctly installed in your PC, please check the version number of Flow Configuration Wizard. Refer to 6.2.5 in IM 01C25R51-01E.

Page 6: Flow Configuration Software Getting Started

<A1. Header> 6

IM 01C25R51-10E

6. Information Provision Web SiteFor FieldMate and/or PRM users, the user’s web site has been already in operation as follows:https://voc.yokogawa.co.jp/PMK/Top.do

The FlowNavigator category within the above web site provides the latest software operation environment supporting information such as documents and update programs. After registration as a FieldMate user, you can find the “Download” → “FlowNavigator” menu by clicking the information icon on the top menu. Entering your FSA120 license number allows you to access the information menu for “FlowNavigator”.

Appendix A Flow Parameters Download ProcedureThe basic procedure for downloading the flow parameters to a device is as follows. Refer to Figure A-1, A-2.

Step1 Upload from Device

Perform “Upload from Device” so that the setting parameters (“Device Flow Parameters” and “Device General Parameters”) in the device are saved to the offline database on your PC.The parameters will then be displayed in the Offline Parameter screen.

Step2 Flow Configuration

Perform Flow configuration in accordance with the guidance in the Flow Configuration Wizard. “Device Flow Parameters” are output by Flow Configuration Wizard.Save “Device Flow Parameters” as XMV file (EJXMVTool) or VMV file (DYFMVTool) in the last menu, and click the “Apply” button.“Device Flow Parameters” are then stored to the offline database on your PC.

NOTEClicking on Apply does not download the flow parameters to the device.

Step3 Download to Device

Perform “Download to Device”. “Device Flow Parameters” will then be downloaded together with the “Device General Parameters” to the device.

Page 7: Flow Configuration Software Getting Started

<A1. Header> 7

IM 01C25R51-10E

IMPORTANTFor FOUNDATION Fieldbus, following block must be checked on the “Download blocks” menu in the Offline Parameter screen to download “Device Flow Parameters” set by Flow Configuration Wizard.EJX910 FOUNDATION fieldbus DTM: FTB blockDYF(SoftDL) FOUNDATION fieldbus DTM: AR block

“Download blocks” menu(EJX910 FOUNDATION fieldbus DTM)

“Download blocks” menu (DYF(SoftDL) FOUNDATION fieldbus DTM)

Figure A-1 “Download blocks” menu in the Offline Parameter

Offline Parameter Flow Configuration Wizard Offline Parameter

OfflineDatabase

OfflineDatabase

OfflineDatabase

Step 1 Step 2 Step 3

Device General Parameters (Default value: , Configured value: )Device Flow Parameters (Default value: , Configured value: )

*: Confirm the checkbox on the “Download blocks” menu in the Offline Parameter (refer to Figure A-1)

*

Figure A-2 Procedure to Download the Parameters to the Device

Page 8: Flow Configuration Software Getting Started

<A1. Header> 8

IM 01C25R51-10E

Appendix B Flow configuration for EJX910A/EJX930A HART 7 modelFlow configuration for EJX910A/EJX930A HART 7 model is shown below.Open Segment Viewer on FieldMate.A device icon appears on the window if it is successful to connect to FieldMate.

Figure B-1 Segment Viewer

Select the icon of the target device. Click the [Action] → [Select DTM]Select “EJX910 V2.1” DTM and click OK.

Figure B-2 Select “EJX910 V2.1” DTM

For the following operations, perform in the same procedure as the flow configuration for EJX910A/EJX930A HART 5 model.

Page 9: Flow Configuration Software Getting Started

<A1. Header> 9

IM 01C25R51-10E

NOTEFlowNavigator works on following Device DTM.

Device DTM Name (EJX910 HART DTM)

Device DTM EJX Multivariable TransmitterName Model Name HART Protocol

RevisionDevice Type Device Revision

EJX910 V1.1

EJX910AEJX930A

5

EJX910(0x0054)

1

EJX910 V2.1 EJX910(0x0054)

2

EJX910 V2.1* 7 EJX910(0x3754)

10

*: For EJX910A/EJX930A HART 7 model, “EJX910 V2.1” DTM is used for FlowNavigator.

NOTEUse the device DTM “EJX910 V2.1” for EJX910A/EJX930A HART 7 model. “EJX910 V2.1” is a DTM which corresponds to EJX910A/EJX930A HART 5 model (Device revision 2). Flow parameter configuration by FlowNavigator can be done by this DTM.

NOTEGeneral parameter configuration for EJX910A/EJX930A HART 7 model (Device revision 10) can be done by “EJX910 HART7 DTM”. When starting FieldMate for EJX910A/EJX930A HART 7 model, “EJX910 HART7 DTM” is automatically assigned by default. So when using FlowNavigator, select “EJX910 V2.1” DTM manually.

Page 10: Flow Configuration Software Getting Started

<A1. Header> 10

IM 01C25R51-10E

PART B

目次1. 構成2. 使用に際しての注意3. インストールの流れ4. 流量設定ウィザードの重要な注意点5. ソフトウェアのバージョン6. 情報提供ウェブサイト付録1. 流量パラメータダウンロード手順付録2. EJX910A/EJX930A HART 7形の流量設定

このたびは、FSA120流量演算設定ソフトウェアをお買い上げいただきましてありがとうございます。本書は、ソフトウェアパッケージを入手後,ユーザが最初に行うことについて説明しています。パッケージを受領いたしましたら,本書をよくお読みいただき,指示の通りに操作していただけますようお願いいたします。

1. 構成FSA120パッケージに付属するアイテムを以下の図に示します。

FieldMate(付属)

ディスク No.1 ディスク No.2 ライセンスシート No.1 ドキュメント No.1, No.2

CD-ROM

FieldMate

DVD-ROM

Device Files

ライセンス番号シート

FieldMate

冊子ドキュメント

FieldMate

ディスク No.3

CD-ROM

FlowNavigator

ライセンスシート No.2 ドキュメント No.3, No.4

ライセンス番号シート

FlowNavigator

冊子ドキュメント

FlowNavigator

FSA120

USB FieldMate モデム(オプション)

F01.ai

FlowNavigator

図1 FSA120の構成

Page 11: Flow Configuration Software Getting Started

<A1. Header> 11

IM 01C25R51-10E

それぞれのディスクは以下のソフトウェアを含みます。

●CD-ROM/DVD-ROM:ディスク3枚(1) FieldMate<ディスクNo.1>(2) DeviceFiles(機器DTM*を含む)<ディスクNo.2> *:機器DTMはYokogawaDTMLibraryHART/FOUNDATIONfieldbusにより配布されます。(3) FlowNavigator(FlowNavigatorプログラムとリソースを含む)<ディスクNo.3>

●ライセンスシート:2部(1) FieldMateライセンス番号シート(BasicまたはAdvanceをオーダ時に選択) <ライセンスシートNo.1>(2) FlowNavigatorライセンス番号シート<ライセンスシートNo.2>

●冊子ドキュメント:4部(1) FieldMateGettingStarted(FieldMate機器調整・設定ソフトウェア 簡易スタートマニュアル)

(IM01R01A04-01E)<ドキュメントNo.1>(2) FieldMateOperationalPrecaution(操作注意事項)(IM01R01A01-91E)<ドキュメントNo.2>(3) FlowNavigatorGettingStarted(FSA120流量演算設定ソフトウェア 簡易スタートマニュアル)

(IM01C25R51-10E)<ドキュメントNo.3>(本冊子)(4) FlowNavigatorソフトウェア使用許諾契約書<ドキュメントNo.4>

●USBFieldMateモデム(オプション)

2. 使用に際しての注意1) FlowNavigatorはFDT/DTM技術を使用したソフトウェアです。このソフトウェアを使用する場合は,フレームア

プリケーションが必要です。横河電機の標準フレームアプリケーションとしてFieldMateが付属しています。 FlowNavigatorの品質と操作性はFieldMate上のみで保障されます。FieldMateをフレームアプリケーションと

して使用してください。さらに,通信DTMとしてFieldMateに付属するフィールド通信サーバーを使用することができます。FieldMateのインストールと操作は以下の冊子ドキュメントを参照ください。

 ・ FieldMateGettingStarted(FieldMate機器調整・設定ソフトウェア 簡易スタートマニュアル)(IM01R01A04-01E)<ドキュメントNo.1>

 ・ FieldMateOperationalPrecaution(操作注意事項)(IM01R01A01-91E)<ドキュメントNo.2>

インストールと操作の詳細は,スタートメニューから表示されるpdf形式のFieldMate取扱説明書も合わせて参照してください。

2) 実際の操作を始める前にはFlowNavigator取扱説明書をよく読み,インストールと操作に関する知識を習得してください。

FSA120流量演算設定ソフトウェアの取扱説明書(IM01C25R51-01JA)はFlowNavigatorと印字されたCD-ROM中のpdf形式のファイルとして提供され,以下の場所にあります。

<FlowNavigatorCD-ROM>:¥EJXMVTool_Manual.pdf

<FlowNavigatorCD-ROM>:¥DYFMVTool_Manual.pdf

FlowNavigatorのCD-ROMをPCのCD-ROMドライブにセットしファイル名をダブルクリックします。pdf形式のファイルを読むためには,AdobeReaderが必要となります。AdobeReaderがPCにない場合は,以下ウェブサイトからダウンロードし,インストールしてください。

http://www.adobe.com/

3. インストールの流れ以下は標準のインストール手順です。条件により手順は異なってきますので,それぞれ指定された取扱説明書の中に記載されている内容を読んで,指示に従ってください。

Step 1共存できないソフトウェアが存在しないことを確認します(<ドキュメントNo.2>)

Page 12: Flow Configuration Software Getting Started

<A1. Header> 12

IM 01C25R51-10E

Step 2 通信機器(FOUNDATIONフィールドバス通信)用のソフトウェアをインストールします

Step 3 FieldMateをインストールします(<ドキュメントNo.1>)

1) FieldMateをインストールします<ディスクNo.1>2) FieldMateのライセンス番号を入力します<ライセンスシートNo.1>3) DeviceFilesをインストールします<ディスクNo.2>

Step 4 FlowNavigatorをインストールします<ディスクNo.3>

Step 5 FieldMateを起動します

1) FieldMateのユーザ登録,アクティベーションキーの入力を行います(<ドキュメントNo.1>)

2) 機器DTMを起動します

Step 6 FlowNavigatorプログラムを起動します

1) FlowNavigatorのライセンス番号を入力します<ライセンスシートNo.2>

4. 流量設定ウィザードの重要な注意点

●[Apply]ボタンに関する補足説明[Apply]ボタンをクリックしたとき,流量パラメータは一時的にPCのオフラインデータベースに保存されます。流量パラメータを機器にダウンロードするために,オフラインパラメータ画面の「機器にダウンロード」を実施します。流量パラメータのダウンロード手順に関する基本情報については付録1を参照してください。

●EJX910A/EJX930AHART7形の製品に関する補足説明FlowNavigatorによる流量パラメータ設定は“EJX910 V2.1”DTMによって実行されます。詳細は付録2を参照してください。

5. ソフトウェアのバージョン以下に,パッケージのソフトウェアバージョン情報をまとめてあります。なお,ソフトウェアの最新バージョン/レビジョン番号はFieldMateのウェブサイトで確認してください。ソフトウェアのバージョン/レビジョン番号の確認方法は,取扱説明書IM 01C25R51-01JA の4.2.6項を参照してください。

FSA120パッケージ

FlowNavigatorディスク FieldMate

YokogawaDTMLibrary(DeviceFiles*)

機器DTM

R1.05.00 R1.05.00 R2.04.00 HART 2011-3FOUNDATIONfieldbus 2011-4(R3.03.00)

EJX910HART: EJX910V1.1 1.4.124.16 EJX910V2.1 1.4.160.27EJX910FOUNDATIONフィールドバス: EJX910V1.2 1.2.81.108 EJX910V2.1 1.2.81.108DYF(SoftDL)FOUNDATIONフィールドバス: DYF(SoftDL)V3.1 1.2.81.108

*:FieldMateとDeviceFilesの相互運用性については下記のアドレスで確認できます。https://voc.yokogawa.co.jp/PMK/Top.do

Page 13: Flow Configuration Software Getting Started

<A1. Header> 13

IM 01C25R51-10E

6. 情報提供ウェブサイトFieldMateとPRMのユーザ向けウェブサイトが以下のアドレスで公開されています。 https://voc.yokogawa.co.jp/PMK/Top.do

上記のウェブサイトのFlowNavigatorのカテゴリでは,最新のソフトウェア動作環境をサポートする情報(例えばドキュメントや更新プログラム)が用意されています。FieldMateのユーザとして登録したのち,トップメニューから[ダウンロード]→[FlowNavigator]とアイコンをクリックするとFlowNavigatorのライセンス入力画面が表示されます。ライセンス番号を入力するとFlowNavigatorの情報メニューにアクセスすることができるようになります。

付録1. 流量パラメータダウンロード手順流量パラメータを機器にダウンロードする基本手順は以下の通りです。図付1.2を参照してください。

Step 1 機器からのアップロード

PCのオフラインデータベースに機器の設定データ(機器流量パラメータと機器汎用パラメータ)を保存するために「機器からアップロード」を実行します。アップロードされたパラメータはオフラインパラメータ画面に表示されます。

Step 2 流量設定

流量設定ウィザードの案内に従って流量設定を実行してください。流量設定ウィザードにより機器流量パラメータが計算されます。最後の画面のメニューで機器流量パラメータをXMVファイル(EJXMVTool)またはVMVファイル(DYFMVTool)形式で保存したうえで,“Apply”ボタンを押してください。機器流量パラメータはPCのオフラインデータベースに保存されます。

注記

Applyを押すだけでは,流量パラメータは機器にダウンロードされません。

Step 3 機器へのダウンロード

「機器にダウンロード」を実行します。機器流量パラメータは機器汎用パラメータと共に機器にダウンロードされます。

Page 14: Flow Configuration Software Getting Started

<A1. Header> 14

IM 01C25R51-10E

重要

FOUNDATIONフィールドバスでは,流量設定ウィザードで設定・計算された機器流量パラメータをダウンロードするためには,オフラインパラメータ画面中の“Downloadblocks”メニューで以下のブロックをチェックしてください。 EJX910FOUNDATIONフィールドバスDTM:FTBブロック DYF(SoftDL)FOUNDATIONフィールドバスDTM:ARブロック

“Download blocks” メニュー (EJX910 FOUNDATION フィールドバス DTM)

“Download blocks” メニュー (DYF(SoftDL) FOUNDATION フィールドバス DTM)

図付1.1オフラインパラメータ内の“Downloadblocks”メニュー

オフラインパラメータ 流量設定ウィザード オフラインパラメータ

オフラインデータベース

オフラインデータベース

オフラインデータベース

Step 1 Step 2 Step 3

機器汎用パラメータ(デフォルト値:□,設定値:■)機器流量パラメータ(デフォルト値:○,設定値:●)

*:オフラインパラメータの“Download blocks” メニューのチェックボックスを確認してください。(図付1.1参照)

*

図付1.2機器へのダウンロード手順

Page 15: Flow Configuration Software Getting Started

<A1. Header> 15

IM 01C25R51-10E

付録2. EJX910A/EJX930A HART 7形の流量設定以下に、EJX910A/EJX930A HART 7形の流量設定方法を示します。FieldMate でセグメントビューワを実行します。

FieldMateが通信の接続に成功した場合,画面に機器のアイコンが表示されます。

図付2.1セグメントビューワ

対象機器のアイコンを選択します。[アクション] → [DTMを選択]をクリックします。“EJX910 V2.1” DTMを選択し,OKをクリックします。

図付2.2 “EJX910V2.1”DTMを選択

以降はEJX910A/EJX930A HART 5形の流量設定と同様の手順で操作を行ってください。

Page 16: Flow Configuration Software Getting Started

<A1. Header> 16

IM 01C25R51-10E

注記

FlowNavigatorは以下の機器DTMで実行されます。

機器DTM名称(EJX910HARTDTM)

機器DTM EJXマルチバリアブル伝送器

名称 モデル名 HART通信レビジョン 機器タイプ 機器レビジョン

EJX910V1.1 EJX910AEJX930A

5 EJX910(0x0054)

1

EJX910V2.1 EJX910(0x0054)

2

EJX910V2.1* 7 EJX910(0x3754)

10

*: EJX910A/EJX930AHART7形ではFlowNavigatorを使用する場合は“EJX910V2.1”DTMを使用します。

注記

EJX910A/EJX930AHART7形に対しては,機器DTMとして“EJX910V2.1”を使用してください。“EJX910V2.1”はEJX910A/EJX930AHART5形(機器レビジョン2)に対応するDTMです。FlowNavigatorによる流量パラメータ設定はこのDTMを使用して行います。

注記

EJX910A/EJX930AHART7形(機器レビジョン10)の汎用パラメータ設定は“EJX910HART7DTM”を使用して行います。EJX910A/EJX930AHART7形に対してFieldMateを起動すると“EJX910HART7DTM”が自動的に割り付けられます。FlowNavigatorを使用するときは“EJX910V2.1”DTMを手動で割り付けます。

Revision InformationJanuary 2007/1st Edition Newly published.April 2007/2nd Edition Add Important notice regarding flow configuration wizard.August 2007/3rd Edition Delete Important notice regarding the setting of External temperature and Pressure. Add the additional installer to update R1.02.00 to R1.02.01.February 2008/4th Edition Add “VI. Information Provision web Site” for EJXMVTool Revise the information of FieldMate components. Delete the additional installer to update R1.02.00 to R1.02.01December 2008/5th Edition Add the latest revision information for FSA120 due the release of FieldMate R2.June 2010/6th Edition Full-fledged revision because of adding the DYFMVTool program for digitalYEWFLO

Vortex Flowmeter and change of the product name to “FieldMate FlowNavigator”.September 2011/7th Edition Add supplemental explanation for EJ910A/EJX930A HART protocol revision 7 model. Correspond to R1.05. • Display image is showed in Windows 7 environment. • Add PART B (Japanese version)August 2012/8th Edition Add the USB FieldMate Modem as option.