flexible ac current probe - u-flex series (head) 170918 01
TRANSCRIPT
Universal Technic
Website : www.universal-technic.com Email : [email protected]
1, Rue Robert et Sonia DELAUNAY 75011 PARIS – France Tél. : (33) 01 43 70 08 00 Fax : (33) 01 43 48 44 07
SPECIFICATION
MODEL UF 3000-c UF 3000-d
Output Sensitivity 103 mV/kA @ 50Hz 445 mV/kA @ 50Hz
Output Sensitivity Tolerance ± 7 %
Linearity (10% to 100% of range) ± 0.2% of reading
Internal resistance (2” / 3” / 4”) 118 / 157 / 236 / 314Ω nominal 551 / 734 / 1100 / 1465 Ω nominal
Frequency Range 10Hz to 20kHz (-1dB) 10Hz to 5kHz (-1dB)
Phase Error ≤ 1°
Conductor Position Sensitivity ± 2.% of reading
Probe Length 450mm (18”), 610mm (24”), 915mm (36”), 1220mm (48”)
Working Voltage 1000V ACRMS or DC
Probe Cable Diameter 9.9 mm
Output Cable Length 2 m
Operating Temperature -20C to 65C)
Temp. Coefficient ± 0.05% of reading per C
Storage Temperature -40C to 75C
Ingress Protection IP65 Dust and Water Resistant IEC 60529:2013
Flexible AC current Probe - U-Flex Series The U-Flex is a flexible AC current probe utilises the Rogowski principle. After appropriate signal conditioning, it can be used with digital multimeters, recorders and other suitable equipment to measure current from very low frequencies up to 20kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
All Accuracies Stated at: 23C ± 1C
Website : www.universal-technic.com Email : [email protected] 1, Rue Robert et Sonia DELAUNAY 75011 PARIS – France Tél. : (33) 01 43 70 08 00 Fax : (33) 01 43 48 44 07
Safety Standards EN 61010-1 EN 61010-2-032 1000V RMS Measurement Category III 600V RMS Measurement Category IV Pollution Degree 2 Dimensions
in mm
60.0
R1
R2
SCREEN
HEADRESISTANCE
LOADRESISTANCE
P3
P2
P1
FLEXPROBE INTER FACE
CALIBRATION CIRCUIT
9.9
34.0
22.5
2000.0
Schematic