flex! flexible power from 100% till 150% flexible input from 115 till 500vac flexible short circuit...

17
FLEX! Flexible power from 100% till 150% Flexible inpu from 115 till 500Vac Flexible short circuit and overload protectio Extremely compact design Input voltages 115 - 230 - 400 - 500Vac Single-phase, two-phase, three-phase Output 12 - 24 - 48Vdc Output protection mode, selectable among Hiccup, Manual Restart and Fold Back Temperature Operation range: from - 25/+70°C DIN rail mounting: fast and reliable clip on device Your freedom of choice in power supply

Upload: jeffry-brooks

Post on 18-Jan-2016

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX!

Flexible power from 100% till 150%

Flexible inputfrom 115 till 500Vac

Flexible short circuit and overload protection

Extremely compact designInput voltages 115 - 230 - 400 - 500VacSingle-phase, two-phase, three-phase Output 12 - 24 - 48Vdc Output protection mode, selectable among Hiccup, Manual Restart and Fold BackTemperature Operation range: from -25/+70°C DIN rail mounting: fast and reliable clip on device

Your freedom of choice in power supply

Page 2: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX!

Based on Semi-resonant Switching Technology: high performance till 93% and highly dynamic output power.

Very compact in size and cost-effective, they are the perfect choice when power supply is needed for electronic loads, PLCs, sensors, resistive, inductive and capacitive loads.

One single article in your stock suits all input voltage options.

High reliability and durability: MTBF values up to 500.000 hours. 3 years Warranty.

A new range of stabilized power supplies for industrial use

Page 3: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! line products

Model Output Current A @40°C

Input Voltage

Vac

Output voltage

Vdc

FLEX6024A 3 115 - 230 24

FLEX9024A 5 115 - 230 24

FLEX17024A 7.5 115 - 230 24

FLEX28024A 14.5 115 - 230 24

FLEX50024A 25 115 - 230 24

FLEX9024B 5 230-400-500 24

FLEX17024B 7.5 230-400-500 24

FLEX28024B 15 230-400-500 24

FLEX50024B 25 400-500 3ph 24

Page 4: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! line products

Page 5: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

Very small dimensions

The higher performances obtained with the FLEX! line, allow almost half dimensions as conventional technology and higher performances. An example is Flex6024A 60W with maximum current till 6A. In permanent duty at 40°C it can deliver 3A at 24Vdc.

100mm

50mm

50mm

115mm

110mm

50mm

Power supply actually in the

market

Flex6024A

Page 6: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! Products 90, 170 and 280 B, can be used with the most common mains voltage input

It simplifies stock management.

Wide Range input voltage 230-400-500 Vac

230 Vac400 Vac500 Vac

Page 7: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

… Or we can obtain a higher operating temperatures till 70°C with

5 A at 60 °C Power Boost 7,5 A (3 minutes)

withFlex 17024…

We can obtain more current … 7.5 A at 40 °C

Do you need more current? Do you need a wider operating temperature range?

Just One Power Supply for all needs

FLEX! fits all applications

Page 8: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FFLEX! supplies 50% more permanent current in applications at 40°C.

uDuring transients FLEX! can supply up to 100% more current than rated. As a consequence it is not necessary to step up the size of the power supply to meet peak load requirements.

Higher Current / Power100% Power 60°C

150% Power at 60°C

Page 9: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! 280 e 500 can be easily connected in parallel to increase available power.

They don’t need a centesimal adjustment, just use a tester to regulate the first and than the second.

Just remove the jumper and it is done.

Easy parallel for double power

Remove Jumpers

Double Power

Page 10: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! devices 170 - 280 and 500W are equipped with Power Good relais contact

“Power Good” Output voltage status control

The Power Good contact switches from NC to NA when the output voltage goes below -10% of rated (20Vdc at rated 24Vdc).Over Load Situation.

It is particulary useful as monitor, in redundancy applications

Page 11: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

1st protection mode“Hiccup”

HICCUP (automatic restart):

This is the default factory setting of all FLEX! units

In case of short-circuit or overloading, the output current is interrupted. The device tries again to reestablish output voltage and normal condition about every 2 second till the problem is cleared.

Jumper position

Page 12: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

2nd protection mode“Manual reset”

MANUAL RESET (manual restart by operator): In case of short-circuit or overloading, the output current is interrupted. In order to restart the output it is necessary to interrupt the input circuit for about 1 minute.

This protection mode is particulary suggested in applications where safety procedures require that reset be carried out by an authorized physical person.

Jumper position

Page 13: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

3rd protection mode“Continuous Out Mode”

Over load Short Circuit

FFOLD BACK In case of a short-circuit or overload this protection mode does not shut down the output but reduce the voltage and regulate current.

WWhen a short circuit or an overload occur the FLEX! unit output can accept up to 1,5 times rated current (In) at 60°C (in some units even more). The output voltage is gradually reduced till almost zero as the current increase. In this mode the unit never switches off.

Jumper position

Page 14: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

FLEX! MeetsEN 60204-1 Regulation

The regulation EN60204-1 addresses safety issues in industrial applications where power supply to a load is delivered by electronic stabilized power supply devices.

Safety in case of overload is a specific focus of the norm. Particularly in case the load is subdivided in more circuits with individual overload protection devices

The main requirement of the norms is that the power supply must be able to withstand a current at least 50% higher than its rated value for 1hr, while at the same time keeping the output voltage within -10% of rated value

Page 15: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

Conforming to EN60204-1 requirements implies a …

If the power supply does not meet the requirements …

…change in circuit design criteria

…it is no longer allowed to use a power supply whose rated current is the same of rated

load demand

Important, immediate and practical consequence

FLEX! MeetsEN 60204-1 Regulation

Page 16: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

In choosing the protection devices for a selective protection of the output loads conforming with EN60204-1, a good safety margin is needed between the thermal overload threshold of each protection device and the rated current of the power supply. This because if they are too close, the power supply will switch off before the protection device has the time to sense the overload.

There are only two possible solutions: increase the size of the power supply to

achieve the required margin (more expensive)

or use devices designed specifically for this conditions, as FLEX!

FLEX! MeetsEN 60204-1 Regulation

Page 17: FLEX! Flexible power from 100% till 150% Flexible input from 115 till 500Vac Flexible short circuit and overload protection  Extremely compact design

With FLEX! it is possible to have 50% more current than the rated value at 60°C. In this way FLEX! guarantee the selective protection of individual output lines

Example in previous slide: Flex28024A can supply a continuous load of 10A (@ 40°C). In case of overload, it will deliver up to 15A and keep the output voltage within -10% of rated (as EN60204-1 requires). This allows to choose a magneto-thermic switch with a tripping threshold set within 50% above rated current of the power supply. In case of overload on one of the output lines, the magneto-thermic switch protecting that line will have the time to intervene, thereby assuring a continuing power supply to the other line (PLC) of the circuit.

In x 1.5

FLEX! MeetsEN 60204-1 Regulation