first results of fast ir camera diagnostic j-w. ahn and r. maingi ornl nstx monday physics meeting...

10
First results of fast IR camera First results of fast IR camera diagnostic diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX NSTX Supported by College W&M Colorado Sch Mines Columbia U CompX General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics New York U Old Dominion U ORNL PPPL PSI Princeton U Purdue U SNL Think Tank, Inc. UC Davis UC Irvine UCLA UCSD U Colorado U Illinois U Maryland U Rochester U Washington U Wisconsin Culham Sci Ctr U St. Andrews York U Chubu U Fukui U Hiroshima U Hyogo U Kyoto U Kyushu U Kyushu Tokai U NIFS Niigata U U Tokyo JAEA Hebrew U Ioffe Inst RRC Kurchatov Inst TRINITI KBSI KAIST POSTECH ASIPP ENEA, Frascati CEA, Cadarache IPP, Jülich IPP, Garching ASCR, Czech Rep U Quebec

Upload: neal-neal

Post on 18-Jan-2018

221 views

Category:

Documents


0 download

DESCRIPTION

NSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn)June 22, IR images of lower divertor for an ELMy H-mode View from the top, 128x128 pixels, 1.6kHz Radial cut for data analysis

TRANSCRIPT

Page 1: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

First results of fast IR camera diagnosticFirst results of fast IR camera diagnostic

J-W. Ahn and R. Maingi

ORNLNSTX Monday Physics Meeting

LSB-318, PPPLJune 22, 2009

NSTXNSTX Supported by

College W&MColorado Sch MinesColumbia UCompXGeneral AtomicsINELJohns Hopkins ULANLLLNLLodestarMITNova PhotonicsNew York UOld Dominion UORNLPPPLPSIPrinceton UPurdue USNLThink Tank, Inc.UC DavisUC IrvineUCLAUCSDU ColoradoU IllinoisU MarylandU RochesterU WashingtonU Wisconsin

Culham Sci CtrU St. Andrews

York UChubu UFukui U

Hiroshima UHyogo UKyoto U

Kyushu UKyushu Tokai U

NIFSNiigata UU Tokyo

JAEAHebrew UIoffe Inst

RRC Kurchatov InstTRINITI

KBSIKAIST

POSTECHASIPP

ENEA, FrascatiCEA, Cadarache

IPP, JülichIPP, Garching

ASCR, Czech RepU Quebec

Page 2: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 2June 22, 2009

Summary

• The new fast IR camera is working reliably to measure divertor heat flux with temporal resolution of 1.6 - 6.3kHz and spatial resolution of 6.4mm

• Temporal resolution is fast enough to resolve transient

events

• Time averaged temperature and heat flux profiles agree well with slow IR data

• Data analysis for various plasma conditions in progress

Page 3: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 3June 22, 2009

IR images of lower divertor for an ELMy H-mode

View from the top, 128x128 pixels, 1.6kHz

Radial cut for data analysis

Page 4: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 4June 22, 2009

Measured surface temperature

Temperature profiles from measured surface emissivity

1.6kHz

Page 5: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 5June 22, 2009

Calculated heat flux

Heat flux profiles from surface temperature by solving heat conduction equation

1.6kHz

Page 6: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 6June 22, 2009

ELM resolved surface temperature

1.6kHz

Short ELM rise time gives only one frame for a rising ELM even at 1.6kHz

Page 7: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 7June 22, 2009

ELM resolved heat flux

1.6kHz

ELMs push strike point out by 2-3cm

Page 8: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 8June 22, 2009

Comparison with slow IR measurement

30Hz 1.6kHz

Temp. profiles from slow IR Time averaged temperature profiles from fast IR

Page 9: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 9June 22, 2009

Comparison with slow IR measurement

30Hz 1.6kHz

Heat flux profiles from slow IR Time averaged heat flux profiles from fast IR

Page 10: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College

NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 10June 22, 2009

We appreciate excellent technical supports from PPPL staff members!!!