Your Safety, Our Technology World Class Leaders in Fire Detection Since 1918 Low Cost High Quality Low Carbon Emissions Innovative Technology UK Manufactured Low Maintenance PRODUCT CATALOGUE The UK’s First Low Voltage, Intelligent, LED EMERGENCY LIGHTING SYSTEM Hochiki Europe is a member of BEST MEANS OF ESCAPE PRODUCT

Upload: others

Post on 26-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

Your

Saf

ety,

Our

Tec

hno

log

y

Wor

ld C

lass

Lea

der

s in

Fir

e D

etec

tion

Sin

ce 1

91

8

Low CostHigh Quality

Low Carbon EmissionsInnovative Technology

UK ManufacturedLow Maintenance

PRODUCT CATALOGUE

The UK’s First Low Voltage,Intelligent, LED EMERGENCYLIGHTING SYSTEM

HochikiEurope

is a memberof

BEST MEANS OF ESCAPE PRODUCT

Page 2: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

Contents

2

Introduction 3

A Greener Solution to Emergency Lighting 4

The Benefits of FIREscape 5

Operational Reliability 5

A Pioneer in Exit Lighting 5

System Topography 6

Quick and Easy Installation 6

Energy Consumption and CO2e Emissions 7

Automatic Monitoring 7

System Structure 8-9

FIREscape Products 10-19

FIREscape Accessories 20-23

FIREscape Software 24

FIREscape Photometric Data 25

Design Guide 26

Index 27

Page 3: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

Cost Effective and EnvironmentallyFriendly Emergency LightingHochiki Europe, world leaders in fire detection manufacturing introduces a brand new concept to theUK market - an innovative new Emergency Lighting system, FIREscape.

FIREscape is a unique, highly cost effective and environmentally friendly emergency lightingsystem based on LED technology and is the UK’s first to be fully intelligent.

FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable, self contained luminaires and signage connected via traditional low-voltage (24V) cabling.

With lighting units fitting directly onto the standard Hochiki Europe sensor base (YBN-R/3)FIREscape offers the installer a brand new and easy solution to the installation of emergencylighting and signage.

3

Low VoltageLess than 5% energy consumption comparedto traditional lighting*1

IntelligentUnique intelligent addressable technologyallows control and testing of individualluminaires

LED TechnologyLow carbon emissions – less than 5% CO2ecompared to traditional lighting*2

Manufactured inthe UKBuilt and tested by Hochiki Europe in UK

Low MaintenanceLess than 1% lamp changes when compared totraditional lighting*3

Simple InstallationLuminaires fit onto the standard HochikiEurope sensor mounting base (YBN-R/3)

*1 Figure based on tests of 100 luminaires over 10 years*2 Figure based on comparison of traditional fluorescent tubing with FIREscape installation of 100 luminaires*3 Figure based on lamp changes over a ten year period for a system of 100 luminaires

Graphics SoftwareAllows instant overview of complete systemand assists in maintenance tasks

Page 4: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

4

A Greener Solution to EmergencyLightingThe FIREscape system is based on LED (Light Emitting Diode) solutions that consider the usefullife of the entire emergency light system, from its installation to the recycling of the equipment at theend of the life-cycle.

The FIREscape emergency light system uses fully recyclable materials that do not place anunnecessary burden on the environment. Due to their unique low-voltage solution, cabling costs arereduced by 60% during installation when compared to old central battery-based systems.

Due to their self-contained backup power source, the FIREscape lighting devices can usescreened, non-fire rated cabling, instead of heavy and costly fire resistant cabling reducing theinstallation costs associated with traditional emergency lighting systems.

The environmentally friendly values in the FIREscape emergency lighting system are specificallyevident in the energy costs and CO2e emissions, which are associated with using and maintaining thesystem.

The graph (right) compares theenergy consumption and CO2eemissions of emergency light systemsusing traditional mains-poweredfluorescent technology, a mains-powered LED equivalent and the low-voltage FIREscape system, onan annual basis in a 100-luminariesinstallation.

The FIREscape emergency lightsystem has also been designed,bearing operational safety and user-friendliness in mind. An internalcontrol system has been includedwithin the system. It constantlycontrols the condition of the lights’LEDs and batteries. If necessary, thesystem will provide specificinformation on the status, eitherlocally on a keypad or by representingit graphically at the control centre ofthe service provider using an IP orGSM network.

By using the optional PC-basedgraphical software, the luminairestatus information can be linked withfloor plans showing the alarmlocations.

Page 5: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

The Benefits of FIREscape

u Environmentally friendly in energy costs and C02 emissions

u A cost-efficient system to implement and maintain

u Exit and emergency lights, which use the same channel

u Easy installation

u Reduced cabling costs

u Bus length 500/1,000M

u Up to 127 luminaries, using one line

u Operational reliability, using luminary-specific backup power sources

u Easy to service and maintain

u The system includes an automatic testing feature

Operational Reliability

Totally unique within the emergency lighting industry, the FIREscape luminaries are connected

using just a standard screened 1.5mm2 cable, which reduces installation costs traditionally associated

with emergency lighting systems. A fire-rated cable is not required because all FIREscape

luminaries are equipped with integral batteries allowing the luminaires to function even in situations

where the control panel becomes damaged or inoperable or the line cable is severed. The luminaire

batteries allow continual operation for up to 3 hours.

In this way the FIREscape emergency light system fulfils all major security light standards, such

as BS5622 for example. See our freely available “Guide to BS5266” booklet for more details on the

system design standard.

A Pioneer in Exit Lighting

FIREscape is an intelligent emergency light system. The emergency light cabling is installed

using the ‘tree structure’ method, which means that several ‘branches’ can be isolated from the main

cable for different floors and areas of a building. Due to its programmability, exit and route lights can

be freely installed anywhere on the line without having to group them into either exit or route lights.

The EL-2 control panel constantly monitors the condition of the luminaires and regularly performs the

periodical testing required by legislation.

5

Page 6: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

6

System TopographyThe diagram below shows a typical multi-panel FIREscape installation. The two EL-2 controlpanels are networked and are controlled by EL-KP keypads. The diagram illustrates how the systemdoes not contain any mains wiring beyond the connection to the normal lighting circuit distributionboard via the EL-IO input/output module for monitoring purposes.

Quick and Easy InstallationInstaller-friendly emergency lights are literally fitted at the turn of a hand. The cabling and bases forthe luminaries can be installed in advance. The luminaires themselves can then be attached to thebases during the final phases of building construction. In this way, the units are protected fromconstruction-related dust, dirt, or damage.

1s 2s 3 seconds

Page 7: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

7

Energy Consumption and CO2eEmissionsA FIREscape exit sign luminaire consumes less than 0.5W, including the power loss. A similar 8Wfluorescent light exit sign luminaire will consume approximately 12W. When compared to 230V LEDlights, FIREscape products save more than 50% of energy. The lower energy consumptiondirectly correlates with lower CO2e emissions. For example, replacing 100 230V fluorescent exitluminaries with FIREscape LED-based exit lights, CO2e emissions would be reduced by 2,100 KGannually.

The graph below shows a total cost of ownership comparison based on a 1000 luminaires, 80% non-maintained 20% maintained, emergency lighting system for manual-test, self-test and Hochiki’sFIREscape system, over a 10 year period.

Automatic MonitoringFIREscape luminaires use LEDs in order to generate the necessary illumination whilst using aslow a current as possible. Even at its highest, the LED current usage is only 80% of the recommendedcurrents of LED manufacturers. In this way, the light power consumption has been kept to a minimumand the overall life of the LED has been extended.

In the case of the EL-DL1, the use of several LEDs in each luminaire is also a safety factor, as even withthe malfunction of one LED, the unit will still illuminate. FIREscape luminaires have an automaticbrightness control and monitoring system, which will increase the brightness of the other LEDs, whena malfunction of one or more LEDs is detected.

Page 8: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

8

System StructureFIREscape brings new technology with new opportunities and solutions for emergency exit lighting.

The core of the FIREscape emergency lighting system is the addressable EL-2 emergency light controlpanel. Altogether 127 exit signs and/or route lights can be connected to each of the two addressable linestotalling 254 devices per panel. Both exit signs and route lights utilise LED (Light Emitting Diode) technology,which guarantees around 10 years lifetime (for maintained devices). The unique ‘Flex-it’ hinge system in theexit signs allows both wall and ceiling mounting utilising the standard Hochiki sensor mounting base, YBN-R/3.

The system is controlled by the discreet EL-KP keypad which features an LCD graphic display. The keypaddisplay can show the address and area text of a device activated or in fault.

MaintenanceThe EN 50172 emergency lighting system standard hasplaced particular attention on the operationalcondition of emergency light systems. The systemshould be regularly tested once a month, as aminimum. TheEL-2 control panel continuously monitors and teststhe functionality of the system automatically.Information on completed tests is stored in thememory of the panel and test reports can be printed forend-user records. Malfunction/alarm information isdisplayed on the screen of the keypad.

CablingCabling of the FIREscape system is easily andquickly achieved using standard, screened cable. Fire-rated cable is not required because each luminaire onthe system contains an integrated rechargeable batterybackup. The system can be wired as a spur and exitlights can be connected in parallel without grouping.FIREscape allows the connection of the cabling toluminaire bases before installing the light units. Unitsare fitted to the base with a simple and fast ‘twist-fit’method, reducing installation time.

Control CentreAny fault information from the FIREscapeemergency light system can be displayed using theoptional EL-GRAPH graphic software which canshow actual building floor-plans with activated points.This software can allow the FIREscape emergencylighting system to be maintained from a controlroom/centre.

Page 9: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

9

GSMRemote control of the EL-2 emergency lightingsystem control panel is possible utilising the GSMalarm transfer unit. Fault data is easily transmitted toend user or service company GSM numbers. EachGSM number can be stored in an ‘alarm ring’ so thateach responsible person can be contacted in turn ifany others are unavailable.

Control StationFIREscape emergency lighting system alarm andfault data, can be linked to a graphics softwarepackage located in a control centre. The softwaredepicts the plan view of the building indicating bothalarm and fault states. By using the FIREscapeINSTALL program it is possible to monitor theemergency lighting system from a central controlstation.

Page 10: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

10

The EL-2 emergency light control panel features two lines, each line canaccommodate 127 exit signs and/or route lights. The EL-2 supplies the operationalvoltage to the light units during normal conditions, whilst also completing thecontinuous testing and monitoring of the equipment on the system. All monitoredevent information is saved in the memory of the control panel, and this can beaccessed by a connected EL-KP key pad (see page 11).

NOTE: Must be used in conjunction with the EL-35V Transformer - see page 20.

Number of lights/signs supported 254 Connection voltage 35 Va.c. (222 VA)Nominal voltage 12 Vd.c.Internal batteries capacity 7.2 AhI/O outputs 2 relay outputsModem connection RS-232User panel connection RS-485/9600 baudEvent memory 500 eventsDimensions (mm) 295W x 475H x 100DMaterial/Colour Sheet steel, powder coated/WhiteWeight including batteries (kg) 8

EL-2 Addressable Control Panel

Page 11: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

11

EL-KP is an emergency lighting control panel keypad for use with the EL-2 panel.The control panel is operated and interrogated through the compact backlit LCDgraphical display, which can be used to check on system status of the lighting unitsincluding battery charge and LED faults. The complete system can support a total of 8keypad units.

Nominal voltage 12 Vd.c.Display LCD graphical display 128 x 64 pixelsDisplay viewing area (mm) 60.0 x 32.5Case colour Light greyDimensions (mm) 147W x 144H x 29DMaterial/Colour Metal alloy, powder coated/IvoryWeight (g) 410

EL-KP Lighting System Keypad

Page 12: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

12

A LED-based, addressable 40m viewable exit light with a flexible ‘flex it’ hingesolution. The exit light’s hinge cup contains the address unit and back-up battery andallows the unit to attach to the standard Hochiki YBN-R/3 sensor mounting base. Thecup also features a bicoloured status LED indicating charge/fault status (green forcharging, red for fault).

Cup colour WhiteMaterial Fire resistant PC + ABS plastic (FR3010)

Plexiglass-8N (sign)Fire class UL94 V-OViewing distance 40mModels available EL-40L (arrow to left)

EL-40R (arrow to right)EL-40D (arrow down)

Operation time 1 hour/3 hourDimensions (mm) 328W x 290H x 100D (inc cup)Distance from wall (in wall installation) 75 (inc 8mm for YBN-R/3 base)Drop from ceiling (in ceiling installation) 295 (inc 8mm for YBN-R/3 base)Weight including battery (g) 690

EL-40 Addressable Exit Sign

EL-40D

Page 13: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

13

A LED-based, addressable 20m viewable exit light with a flexible ‘flex it’ hingesolution. The exit light’s hinge cup contains the address unit and back-up battery andallows the unit to attach to the standard Hochiki YBN-R/3 sensor mounting base. Thecup also features a bicoloured status LED indicating charge/fault status (green forcharging, red for fault).

Cup colour WhiteMaterial Fire resistant PC + ABS plastic (FR3010)

Plexiglass-8N (sign)Fire class UL94 V-OViewing distance 20mModels available EL-20L (arrow to left)

EL-20R (arrow to right)EL-20D (arrow down)

Operation time 1 hour/3 hourDimensions (mm) 202W x 210H x 100D (inc cup)Distance from wall (in wall installation) 75 (inc 8mm for YBN-R/3 base)Drop from ceiling (in ceiling installation) 217 (inc 8mm for YBN-R/3 base)Weight including battery (g) 330

EL-20 Addressable Exit Sign

EL-20D

Page 14: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

14

LED-based, addressable exit lights mounted within a flush-fit ceiling plate with springloaded clips for secure fixing to most hollow ceiling materials. The exit light’s cup (withinthe ceiling void) contains the address unit and back-up battery. The cup also features abicoloured status LED indicating charge/fault status (green for charging, red for fault)which is viewable through a small inspection hole in the ceiling plate. The ceiling platefeatures a standard Hochiki YBN-R/3 sensor mounting base for easy wiring. Available intwo sizes, 20m viewable and 40m viewable.

Ceiling plate colour WhiteMaterials Ceiling plate Powder-coated metal

Cup and sign bar Fire resistant PC + ABS plastic (FR3010)Sign Plexiglass-8N

Fire class UL94 V-OViewing distance EL-F20X - 20m, EL-F40X - 40mModels available EL-F40L (arrow left), EL-F40R (arrow right),EL-F40D (arrow down)

EL-F20L (arrow left), EL-F20R (arrow right),EL-F20D (arrow down) Operation time 1 hour/3 hourOverall dimensions (mm) 251L x 121W x 221H Sign dimensions (mm when installed) 200W x 112H x 6DCut-out dimensions (mm) 225 x 95Maximum ceiling thickness (mm) 20Weight including battery (g) 860 (20m) 1350 (40m)

EL-F20 & EL-F40 Flush-Fit Addressable Exit Signs

EL-F20D

Page 15: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

EL-DL1 is a LED-based, addressable route light/downlighter featuring ten LEDs.The installation interval of the lights is 7.7m, at an installation height of 3.5m. Theunit’s cup-shaped body contains the address unit and the back-up battery. The cupalso features a bicoloured status LED indicating charge/fault status (green forcharging, red for fault) .

The unit has been designed to easily fit onto Hochiki’s standard sensor base, the YBN-R/3.

Case colour WhiteCase material Fire resistant PC + ABS plastic (FR3010)Fire class UL94 V-OOperation time 1 h/3hDimensions (mm) 100 Ø x 50H (inc 8mm for YBN-R/3 base)Weight including battery (g) 100

EL-DL1 Addressable Downlighter

15

Page 16: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

16

EL-DL2 is a LED-based, addressable corridor downlighter featuring one high-powered LED with a specially engineered ‘bubble’ lens. The unit’s body contains theaddress unit and the back-up battery and features a bicoloured status LED indicatingcharge/fault status (green for charging, red for fault).

The unit has been designed to easily fit onto Hochiki’s standard sensor base, the YBN-R/3.

Case colour WhiteCase material Fire resistant PC + ABS plastic (FR3010)Fire class UL94 V-OOperation time 1 h/3hDimensions (mm) 100 Ø x 48H (inc 8mm for YBN-R/3 base)Weight including battery (g) 100

EL-DL2

AVAILABLE END OF 2011

NEW

Page 17: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

17

EL-DL3 is a LED-based, addressable open space downlighter featuring one high-powered LED with a specially engineered ‘bubble’ lens. The unit’s body contains theaddress unit and the back-up battery and features a bicoloured status LED indicatingcharge/fault status (green for charging, red for fault).

The unit has been designed to easily fit onto Hochiki’s standard sensor base, the YBN-R/3.

Case colour WhiteCase material Fire resistant PC + ABS plastic (FR3010)Fire class UL94 V-OOperation time 1 h/3hDimensions (mm) 100 Ø x 48H (inc 8mm for YBN-R/3 base)Weight including battery (g) 100

EL-DL3NEW

AVAILABLE END OF 2011

Page 18: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

18

The EL-DL9 is a non-addressable LED downlighter/route light for use on theFIREscape system. Compatible with the EL-2 Control Panel, the unit has beenspecifically designed for high ceilings to a maximum of 9 metres.

NOTE: A remote power supply is required to power any non-addressable slaveluminaires such as the EL-DL9.

Installation height (m) 9 (max)Fitting method Flush mountingFace colour Silver/greyFace material AluminiumDimensions (mm) 103 Ø x 20H (2mm when fitted)Weight (g) 160

EL-DL9 Downlighter

Page 19: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

19

An LED-based, addressable step lighting unit, which is installed in a standard singlegang electrical back box for a flush-fitting. The back-up battery is contained withinthe back box.

Although low-level lighting is not a requirement under BS5266 this attractive anddiscreet unit is ideal for lighting stairway treads and changes in floor levels.

Case colour WhiteMaterial Fire resistant PC + ABS plastic (FR3010)Fire class UL94V-OOperation time 1 h/3 hDimensions (mm) 80W x 80H x 12DWeight including battery (g) 110

EL-SL Addressable Step Luminaire

Page 20: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

20

FIREscape Accessories

EL-PSUis a bus-controlled Power Supply,which operates with theFIREscape system providingcharge to luminaire batteries.NOTE: A remote power supply isrequired to power any non-addressable slave luminaires (EL-DL9 for example).

u Switched-mode power sourceu Parallel connection for outputs

max. 2.5mm2

u Outputs: 12 Vdc / 24 Vdc(2 x 5 A)

u Batteries: 2 units, 7 Ah / 1 hr standby time

u Group-specific monitoring of emergency lighting

u Controlled using EL-IO unitsu Designed for 12/24 lights

EL-35Vis a transformer for the EL-2emergency light control panel.

u 35 VAC, 220 VAu Output: 35 Vac / 220 VAu Protection class: IP44u Operational temperature: max.

30°Cu Wall installation: with four

screwsu Manufacturing class: SS

4270203 (EN60742)u Weight: 3.2 kg

EL-PMis an under-voltage monitoringdevice that constantly assesses thecondition of a mains lighting circuit.When the lighting circuit is deemedfaulty, the unit will provide a signalthat can be relayed to the controlequipment to initiate emergencyluminaire activation.

EL-FSis ‘flag support’ type fixing for theemergency lighting exit signs EL-20 and EL-40.

EL-CSis a ceiling support fixing for theemergency lighting exit signs EL-20 and EL-40.

Page 21: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

21

FIREscape Accessories

EL-BATis a rechargeable Lithium/Polymerback-up battery for use withluminaires and exit signs within theFIREscape range.

u 320 mAhu 7.4 Vu For use with FIREscape luminaires

and exit signsu Ideal for cold facilities, minimum

operating temperature -25o Cu Provides the BS5266 minimum

3h backup time

EL-1RCis a relay card for use with the EL-2 Emergency Light ControlPanel.

u Equipped with one volt-freerelay output

u Control voltage 12 Vdcu Electricity consumption 37.5 mA

(at 12 Vdc)u Dimensions: 50 x 37 mm

EL-BDCis a battery monitoring card for usewith the EL-2 Emergency LightControl Panel.

EL-EXPis an expansion unit used forexpanding the serial ports of theEL-2 Emergency Light ControlPanel. The unit provides twoadditional ports, SER1 and SER2.

EL-8RCis a relay card which adds 8 relayoutputs to the EL-2 EmergencyLight Control Panel. Each outputcan be programmed with allnecessary functions, including linksto other systems. Upto 4 cards canbe connected to the panelsimultaneously.

u Provides 8 relay outputs 1A at 30V

u RS-485 channel connection (DIL-128)

u A total of 4 cards can be connected to the same channel

u Dimensions: 110 x 75 x 42mmu Fits to DIN rail

u The unit is used to prevent the deep discharge of the panel’s battery during long-duration (over 50 h) power outages

u Provides two additional serial ports within the control panel

u Ports can be configured either as RS-232 or RS-485

u Four integral LEDs to indicate communications

Page 22: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

22

FIREscape Accessories

EL-IOis an I/O unit which is linked to thebus channel (line) of the EL-2Emergency Light Control Panel, fromwhich it receives its operationalvoltage. The unit links startswitches and phase monitors to theFIREscape system.

u 4 inputsu 2 outputsu Dimensions: 100 x 110 x 35 mm

EL-ISOLis an isolator device which shouldbe used when connecting externalequipment to the EL-2 EmergencyLight Control Panel’s RS232outputs, to avoid ground leakages.

EL-LANis a network card, RS232 toethernet adapter, designed forconnecting the EL-2 EmergencyLight Control Panel to anEthernet network.

u 10/100 Mbit/su Operational voltage 9-30 Vdcu Power feed from the EL-2

Emergency Light Control Panel(PRG screw connector)

u Maximum distance from the panel is 200 m

EL-SWT5is a 5-port Ethernet switch whichcan be used for splitting an Ethernetnetwork and extending CAT cabling.

u RJ45 connectorsu Maximum distance to the next

switch or terminal unit 100 mu 10/100 Mbit/su Operational voltage 18.5 to

30.2 Vdcu Electricity consumption ~ 90 mA

(at 24 Vdc)u For power feed HEDSAM POW5

EL-SWT8is an 8-port Ethernet switch whichcan be used for splitting an Ethernetnetwork and extending CAT cabling.

u as per EL-SWT5 above

Page 23: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

23

FIREscape Accessories

EL-MCis a media adaptor capable ofconverting a dual cable to Ethernetin order to extend an Ethernetnetwork across a dual cableconnection

u RJ45 connector for Ethernet / screw connector for dual cable

u Maximum distance 1500 mu Installation in pairs (‘master’ and

‘slave’ units)u No MAC or IP addressesu Transfer capacity: 95 Mbit/s/

200 m ; 20 Mbit/s/1500 mu Operational voltage 5 Vdcu Power consumption max 2 Au HEDSAM POW5 for power feed

and voltage reducer SC-24/5

YBN-R/3is a common mounting base whichis used to mount the FIREscaperange of luminaires and exit signs.

u Electronics freeu Stainless steel contactsu Takes 2.5 mm2 cablesu Slim profile - only 8 mmu Facility for remote indicator u Quick and easy ‘twist on’

connection

TCH-B100is a Hand Held Address Programmerdesigned to address theFIREscape range of luminairesand exit signs. Designed to belight, robust and easy to use itoperates from a single PP3 sizebattery which can provide over8000 operations.(shown with luminaire fitted – not supplied)

u Lightweight designu Quick and reliable addressingu Over 8000 address settings from

one battery

EL-DEis an external weather-proofenclosure designed to allow theexternal mounting of the EL-DLdown lights. The enclosure features1 cable entry which can be glandedand provides an ingress protectionrating of IP67.

Available end of 2011

u Robust designu Provides IP67 protectionu Cable entry can be glandedu Metal, powder-coated body,

acrylic dome

Page 24: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

24

EL-IMPis an installation and programmingsoftware application which can beused to remotely program lightlevels, set up lighting areas, createinput and output parameters etc.

u Allows remote setting of light levels

u Access to Maintained or Non- Maintained settings

u Control over system statusu Allows remote setting of input/

output parametersu Assists in fault findingu Allows uploading and

downloading of datau Assists in report generation

FIREscape Software

EL-GRAPHis an alarm graphics software whichallows the end-user to visuallycheck on the status of the completeFIREscape system, down toindividual point status.

u Fully integrated graphics package

u Individual point monitoringu Reports point status informationu Point interrogation and control

EL-CABis a connection cable for usebetween the EL-2 EmergencyLight Control Panel and a PC/laptop.

USB to Serialcable for use in conjunction with theEL-CAB for connection toPCs/laptops that don’t feature aSerial Port.

Page 25: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

25

FIREscape Photometric Data

MountingHeight (m)

1 LuxAxial to Wall

1 Lux Axial

SpacingBetween

Corridor

2.0 2.27 4.902.5 2.68 6.003.0 3.12 6.903.5 3.45 7.704.0 3.72 8.504.5 2.50 9.205.0 0.70 9.80

EL-DL1 - Corridor Emergency Luminaire

EL-DL9 - Down Light

MAINTAINED Open Area to 0.5 Lux

MountingHeight (m)

0.5 LuxSpacing to Wall

0.25 LuxSpacing Between

2.0 0.95 1.102.5 1.10 1.263.0 1.22 1.393.5 1.36 1.534.0 1.48 1.684.5 1.60 1.805.0 1.70 1.936.0 1.85 2.187.0 1.90 2.468.0 1.64 2.559.0 1.41 2.68

MAINTAINED 2m Wide Corridor

MountingHeight (m)

1.0 LuxSpacing to Wall

0.5 LuxSpacing Between

2.0 1.19 2.702.5 1.37 3.103.0 1.54 3.443.5 1.69 3.844.0 1.81 4.204.5 1.89 4.525.0 1.90 4.806.0 1.50 5.227.0 1.29 5.368.0 1.00 4.649.0 0.50 4.00

NONMAINTAINED

Open Area to 0.5 Lux

MountingHeight (m)

0.5 LuxSpacing to Wall

0.25 LuxSpacing Between

2.0 0.99 1.142.5 1.13 1.303.0 1.27 1.443.5 1.40 1.584.0 1.53 1.734.5 1.65 1.855.0 1.76 1.996.0 1.94 2.237.0 2.05 2.478.0 1.99 2.679.0 1.70 2.82

NONMAINTAINED

2m Wide Corridor

MountingHeight (m)

1.0 LuxSpacing to Wall

0.5 LuxSpacing Between

2.0 1.21 2.802.5 1.41 3.203.0 1.58 3.583.5 1.75 3.964.0 1.89 4.324.5 1.99 4.665.0 2.06 4.986.0 1.86 5.507.0 1.51 5.808.0 1.30 5.649.0 1.00 4.80

MountingHeight (m)

0.5 LuxTransverse to Wall

0.5 LuxTransverse

SpacingBetween

0.5 LuxAxial to Wall

0.5 Lux Axial

SpacingBetween

Open Area

2.0 1.40 1.60 3.00 5.502.5 1.40 1.70 3.50 6.503.0 1.40 1.90 3.60 7.303.5 1.50 2.00 4.50 8.304.0 1.50 2.00 4.30 9.204.5 1.50 2.00 5.00 9.705.0 1.50 2.30 5.00 11.20

Page 26: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

26

Design Guide Non-MaintainedThe lighting only operateswhen the normal mains supplyfails (emergency lightingonly).

MaintainedThe lighting operates normallyand continues to operate whenthe normal mains supply fails(mains lighting and emergencylighting only).

Locating Luminaires - Points of Emphasis

Near StairsEach tread should receivedirect light from the installedemergency lightingluminaire(s), so that theminimum luminance on eachstair tread is 1 Lux.

Near Changes ofLevelSteps or other changes of levelshould receive direct lightfrom an emergency lightingluminaire.

At Each Change ofDirectionEmergency lighting luminairesshall be installed near eachchange of direction as well asnear each intersection ofcorridors on the designatedescape route.

Near Fire FightingEquipment andManual Call PointsWithin 2 metres of all firefighting and fire alarm callpoints an illuminance level of5 Lux is required. This wouldalso apply to a fire alarmcontrol panel on an escaperoute .

Outside and Near toEach Final ExitThe escape route outside ofthe final exit(s) to a place ofsafety shall be illuminated.

Near Each First AidPointThis is a requirement includedin BS 5266 part 7 1999,clause 4. All types of first aidpost including first aid roomsare to be illuminated to a levelof 5 Lux.

Exit DoorsEmergency lighting luminairesshall be installed (near) eachexit door to provideappropriate illuminance nearthe door and at the threshold. However, to provide the 1 Luxon the centre line, theluminaire may need to becloser than the 2msuggested in the diagram.

To Illuminate SafetySignsEmergency lighting luminairesshall be installed to illuminateeach escape sign and safetysign. For externallyilluminated sign boards, aluminaire should be within 2mof the sign. Any further than2m away would be unlikely toilluminate the signsufficiently.

Interpretation:Where a point of emphasis requires a luminaire to be "at", this is not always practical, because, for example, there might be another fitment alreadyat the same point. The luminaire would then be placed at a suitable position no further than 2m from the point of emphasis. Remember the 1 Luxalong the centre line of escape route corridors and stairways should be designed. Where a point of emphasis requires a luminaire to be "near", thisis stated as within 2m horizontally, as seen on a plan. Further information available in our Guide to BS5266 booklet

Page 27: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

Index

27

Automatic Monitoring 7Benefits of FIREscape 5Cabling 8Control Centre 8Control Station 9Design Guide 26Energy Consumption & CO2e Emissions 7EL-1RC Relay Card 21EL-2 Addressable Control Panel 10EL-20 Addressable Exit Sign 13EL-35V Transformer 20EL-40 Addressable Exit Sign 12EL-8RC Relay Card 21EL-BAT Rechargeable Battery 21EL-BDC Battery Monitoring Card 21EL-CAB 24EL-CS Ceiling Support 20EL-DE Downlighter Enclosure 23EL-DL1 Addressable Downlighter 15EL-DL2 Addressable Downlighter 16EL-DL3 Addressable Downlighter 17EL-DL9 Addressable Downlighter 18EL-EXP Expansion Unit 21EL-F20 & EL-F40 Flush-fit Addressable Exit Signs 14EL-FS Flag Support 20EL-GRAPH 24EL-IMP 24EL-IO Input/Output Unit 22EL-ISOL Isolator Device 22EL-KP Lighting System Keypad 11EL-LAN Network Card 22EL-MC Media Adaptor 23FIREscape Photometric Data 25EL-PM Phase Monitor 20EL-PSU Power Supply 20EL-SL Addressable Step Luminaire 19EL-SWT5 5-Port Ethernet Switch 22EL-SWT8 8-Port Ethernet Switch 22Greener Solution to Emergency Lighting 4GSM 9Operational Reliability 5Maintenance 8System Structure 8System Topography 6TCH-B100 23USB to Serial 24YBN-R/3 Mounting Base 23

Page 28: FIREscape Catalogue - 1SS3 - May11 - 1f Layout 1 Catalogue.pdf · FIREscape is based around an addressable, emergency lighting control panel with battery back-up and features addressable,

Hochiki Europe (UK) Ltd. reserves the right to alter thespecification of its products from time to time withoutnotice. Although every effort has been made to ensure theaccuracy of the information contained in this document itis not warranted or represented by Hochiki Europe (UK)Ltd. to be a complete and up-to-date description.

HOCHIKI EUROPE (UK) LIMITEDGrosvenor Road, Gillingham Business ParkGillingham, Kent, ME8 0SA, United KingdomTelephone: +44 (0)1634 260133 Facsimile: +44 (0)1634 260132e-mail (UK): [email protected] (Non UK): [email protected]

Quality System Certificate No. 164 Assessed to ISO9001

Environmental Management SystemCertificate No. EMS 286Assessed to ISO 14001 : 1996

Learn more about the full FIREscape range atwww.hochikieurope.com/firescape

9-5-0-419/ISS3/AUG11