INSTRUCTOR GUIDE October 2008 Approved and Adopted by the Office of State Fire Marshal Recommended for adoption by the Statewide Training and Education Advisory Committee and the State Board of Fire Services CAL FIRE/OSFM State Fire Training D D R R I I V V E E R R / / O O P P E E R R A A T T O O R R 1 1 B B F F I I R R E E A A P P P P A A R R A A T T U U S S RETIRED CURRICULUM

Upload: phungliem

Post on 02-Jan-2017

265 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: fire apparatus driver/operator 1b

INSTRUCTOR GUIDE

October 2008

Approved and Adopted by the Office of State Fire Marshal

Recommended for adoption by the Statewide Training and Education Advisory Committee

and the State Board of Fire Services

CAL FIRE/OSFM State Fire Training

DDRRIIVVEERR//OOPPEERRAATTOORR 11BBFF II RR EE AA PP PP AA RR AA TT UU SS

RETIRED C

URRICULU

M

Page 2: fire apparatus driver/operator 1b

F IRE APPARATUS DRIVER /OPERATOR 1B P U M P O P E R A T I O N S

I N S T R U C T O R G U I D E

Published by STATE FIRE TRAINING PO Box 944246 Sacramento, CA 94244-2460

October 2008 RETIR

ED CURRIC

ULUM

Page 3: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

TABLE OF CONTENTS

State Fire Training .................................................................................................................... i Mission Statement ................................................................................................................ i California Fire Service Training and Education System........................................................ i Acknowledgments................................................................................................................. i

Student Profile .........................................................................................................................iii Target Group........................................................................................................................iii Prerequisites........................................................................................................................iii Desired Attendance Time Frame .........................................................................................iii

Class Requirements and Space ............................................................................................. iv Equipment........................................................................................................................... iv Pumping Grounds and Equipment ...................................................................................... iv Materials ............................................................................................................................. iv

Introduction to the Manual ...................................................................................................... vi Appendix A – Instructor Tests.............................................................................................vii Appendix B – Student Tests................................................................................................vii

Course Outline.......................................................................................................................viii Texts and References ............................................................................................................ ix Calendar of Events ................................................................................................................. xi INSTRUCTOR GUIDE Unit 1: Responsibilities, Standards, and Laws........................................Topics 1-1 through 1-2 Unit 2: Fire Pump Construction and Theory............................................Topics 2-1 through 2-7 Unit 3: Hydraulics .................................................................................Topics 3-1 through 3-10 Unit 4: Inspection, Maintenance, and Troubleshooting............................ Topic 4-1 through 4-5 Unit 5: Pump Practices .......................................................................... Topic 5-1 through 5-10 Unit 6: Pumping Exercises...........................................................................................Topic 6-1 Instructor Tests (With Answers)............................................................................... Appendix A Student Tests (Ready To Copy) .............................................................................. Appendix B RETIR

ED CURRIC

ULUM

Page 4: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 State Fire Training Page i

State Fire Training

Mission Statement The mission of State Fire Training is to enable the California fire service to safely protect life and property through education, training, and certification.

California Fire Service Training and Education System The California Fire Service Training and Education System (CFSTES) was established to provide a single statewide focus for fire service training in California. CFSTES is a composite of all the elements that contribute to the development, delivery, and administration of training for the California fire service. The authority for the central coordination of this effort is vested in the Training Division of the California State Fire Marshal's Office with oversight provided by the State Board of Fire Services. The role of CFSTES is one of facilitating, coordinating, and assisting in the development and implementation of standards and certification for the California fire service. CFSTES manages the California Fire Academy System by providing standardized curriculum and tests; accredited courses leading to certification; approved standardized training programs for local and regional delivery; administering the certification system; and publishing Certification Training Standards, Instructors Guides, Student Manuals, Student Supplements, and other related support materials. This system is as successful and effective as the people involved in it are. It is a fire service system developed by the fire service, for the fire service... and we believe it is the best one in the country.

Acknowledgments State Fire Training coordinated the development of the material contained in this guide. Before its publication, the Statewide Training and Education Advisory Committee (STEAC) and the State Board of Fire Services (SBFS) recommended this guide for adoption by the State Fire Marshal (SFM). This guide is appropriate for fire service personnel and for personnel in related occupations that are pursuing State Fire Training certification.

Ruben Grijalva Director of CAL FIRE

Kate Dargan State Fire Marshal

Tonya Hoover Assistant State Fire Marshal

Mike Richwine Chief, State Fire Training

Ron Coleman Chair, STEAC

RETIRED C

URRICULU

M

Page 5: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 State Fire Training Page ii

Special acknowledgement and thanks are extended to the following members of CDF/State Fire Training Curriculum Development Division for their diligent efforts and contributions that made the final publication of this document possible.

Alicia Hamilton Fire Service Training Specialist III

The material contained in this document was compiled and organized through the cooperative effort of numerous professionals within, and associated with, the California fire service. We gratefully acknowledge these individuals who served as principal developers for this document.

Special acknowledgement and thanks are extended to Mark Romer, Roseville Fire Department and Darren Hall for this updated 2008 edition.

David Anderson CDF – Riverside Unit

Tom Hostetter CDF – Nevada/Yuba/Placer Unit

Gus Bryant Kern County Fire Department

Don Mashburn Sacramento Fire Department

Robert Confer Tiburon And Ben Lomond Fire Districts

Tom Murray San Francisco Fire Department (Retired)

Tom Davis Modesto Regional Fire Training Center

Don Ockey Fresno City Fire Department

Roy Francis Pasadena Fire Department

John Owens CDF – San Luis Obispo Unit

Thomas D. Gallinatti Oakland Fire Department

Mark Romer, Team Leader Roseville Fire Department

"We gratefully acknowledge the hard work and accomplishments of those before us who built

the solid foundation on which this program continues to grow."

RETIRED C

URRICULU

M

Page 6: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Student Profile Page iii

Student Profile

Target Group Fire service emergency response personnel

Prerequisites California Drivers License, Class B, fire fighter restricted (minimum) Fire Fighter I training recommended

Desired Attendance Time Frame None

RETIRED C

URRICULU

M

Page 7: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Class Requirements and Space Page iv

Class Requirements and Space

The characteristics of the classroom and support facilities have a great impact on the learning environment and the instructor's success or failure. For this course, it is advisable for the instructor to adhere as closely as possible to the following guidelines.

Equipment Writing board with markers/erasers Appropriate audiovisual equipment Appropriate audiovisual materials

Pumping Grounds and Equipment 1. Fire apparatus

Materials Unit 1

Course outline Calendar of events Progress chart Activity 1-1-1: Math Skills Pretest

Unit 2 None

Unit 3 Activity 3-2-1: Mathematics Review Activity 3-6-1: Calculating gpm Activity 3-8-1: Calculating Friction Loss Activity 3-9-1: Calculating Pump Discharge Pressure Activity 3-10-1: Fireground Hydraulics

Unit 4 None

Unit 5 Activity 5-6-1: What's Wrong!

RETIRED C

URRICULU

M

Page 8: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Class Requirements and Space Page v

Unit 6 Pumping Exercise 6-1-1: Operating from Draft Pumping Exercise 6-1-2: Operating Using a Forward Lay Pumping Exercise 6-1-3: Operating Using a Reverse Lay Grading Sheet

Written Tests Test 1 Test 2 Test 3 Certification Exam

RETIRED C

URRICULU

M

Page 9: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Introduction to the Manual Page vi

Introduction to the Manual

The 2008 Fire Apparatus Driver/Operator 1B Instructor Guide has been updated to reflect current 2009 NFPA 1002 Standard for Fire Apparatus Driver/Operator Professional Qualifications. This course also requires two corresponding textbooks: the second edition of IFSTA's Pumping Apparatus Driver/Operator Handbook and the Fire Apparatus Driver/Operator 1B Student Supplement published by State Fire Training. All certification exam questions were developed using any one of these textbooks. During the revision process, the developers included the following:

• An increase in group and individual activities

• Endnotes detailing specific code sections as they relate to the lesson plan

• PowerPoint slides for all lesson plans

• Video clips for the pumping exercises

This publication is intended to serve as an instructor guide and includes lesson plans, a slide index, student activities, and tests. For each topic identified in the course outline, a lesson plan has been developed that contains: a time frame, level of instruction, behavioral objective, materials needed, references, preparation statement, lesson content, and endnotes. Suggested application methods have been identified throughout the lessons for you to use during your presentation.

• Time Frame: The estimated duration required for in-class presentation.

• Level Of Instruction: Identifies the instructional level that the material was designed to fulfill. Obviously, you have the latitude to increase the level based on available time, local conditions, and the students' apperceptive base.

• Behavioral Objective: The behavioral objective is a statement of the student's performance desired at the end of instruction. You must ensure that enough information is given in the presentation and/or activities to enable the student to perform according to the goal.

• Materials Needed: This should be a complete list of everything you will need to present the lesson, including visual aids, tests, and so on.

• References: These are the specific references the curriculum development team used when developing the lesson plan. In addition, references may be listed as additional study aids for instructors to enhance the lesson -- books, manuals, bulletins, scripts, visual aid utilization plans, and the like. The corresponding pages in the student supplement are also listed here.

RETIRED C

URRICULU

M

Page 10: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Introduction to the Manual Page vii

• Preparation: The motivational statement connects the student with the lesson plan topic through examples or illustrations relating to their occupation, injury, and even mortality. You will need to develop this statement to fit your target audience.

• Lesson Content: Includes information used in the four-step method of instruction.

Cognitive Lesson Plans PRESENTATION APPLICATION

Everything you say or display Content Notes

Student Participation • Questions • Activities • Audiovisual Cues

Psychomotor Lesson Plan

OPERATIONS KEY POINTS Specific actions to be performed by the students Begin with a verb, followed by a noun

The who, what, when, where, why, and how (the "tricks of the trade") Safety practices

Appendix A – Instructor Tests • Course tests with answer keys.

Appendix B – Student Tests • Test masters to copy for your students. Keep these in good condition to use for future

classes. Collect these tests after they have been graded and discussed in class. • Do not let the students keep them since you will be using the same tests for your

next class.

RETIRED C

URRICULU

M

Page 11: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Course Outline Page viii

Course Outline

Course Objectives: To…

a) Provide students with information on pump construction and theory of pump operations.

b) Provide students with methods for performing basic hydraulics. c) Provide students with information and techniques on basic inspections,

documentation, maintenance, and troubleshooting fire pumps. d) Provide students with the opportunity to increase their pumping skills during

simulated pumping conditions. Course Content................................................................................................................40:00 Unit 1: Responsibilities, Standards, and Laws

1-1 Orientation And Administration ..............................................................................1:30 1-2 Fire Apparatus Driver/Operator Responsibilities....................................................0:30

Unit 2: Fire Pump Construction and Theory 2-1 Types of Fire Pumps..............................................................................................0:45 2-2 Pump Mounting And Drive Arrangements .............................................................0:30 2-3 Pump Piping And Valves .......................................................................................0:15 2-4 Automatic Pressure Control Devices .....................................................................0:15 2-5 Priming Devices.....................................................................................................0:15 2-6 Pump Panel Instrumentation .................................................................................0:15 2-7 Auxiliary Cooling Devices ......................................................................................0:15

Unit 3: Hydraulics 3-1 Basic Hydraulic Terminology And Symbols ...........................................................0:30 3-2 Mathematics Review..............................................................................................1:00 3-3 Characteristics Of Water and Principles Of Pressure ............................................0:30 3-4 Principle Features Of Water Systems....................................................................0:15 3-5 Nozzle Theory .......................................................................................................0:30 3-6 Calculating Gallons Per Minute .............................................................................0:30 3-7 Principles Of Friction Loss.....................................................................................0:15 3-8 Friction Loss Formulas And Calculations...............................................................4:00 3-9 Pump Discharge Pressure.....................................................................................0:30

3-10 Fireground Hydraulic Calculations.........................................................................1:00 RETIR

ED CURRIC

ULUM

Page 12: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Texts and References Page ix

Unit 4: Inspection, Maintenance, and Troubleshooting 4-1 Inspecting The Pump Drive Systems.....................................................................0:15 4-2 Inspecting The Pump Priming Systems .................................................................0:15 4-3 Inspecting The Pump Pressure Control Systems ..................................................0:15 4-4 Pump Service Testing............................................................................................0:45 4-5 Maintenance Of The Pump And Control Systems .................................................1:00

Unit 5: Pump Practices 5-1 Making The Pump Operational (From Tank) .........................................................0:30 5-2 Transitioning To An External Water Supply...........................................................0:30 5-3 Operating From A Hydrant.....................................................................................0:30 5-4 Principles And Practices Of Drafting Operations ...................................................0:30 5-5 Principles Of Relay Pump Operations ...................................................................1:30 5-6 Troubleshooting Pump Operations ........................................................................1:00 5-7 Principles Of Tandem Pumping Operations...........................................................0:15 5-8 Principles Of Dual Pumping Operations ................................................................0:15 5-9 Principles And Practices Of Foam Operations.......................................................1:00

5-10 Sprinkler And Standpipe Support ..........................................................................0:30 Unit 6: Pumping Exercises

6-1 Introduction To The Pumping Exercises................................................................0:30 Practice and Testing the Pumping Exercises ...............................................................13:00 Unit Tests ...........................................................................................................................2:00 Review And Certification Exam........................................................................................2:00

Texts and References

• Driver Operator Training Program, Modesto Regional Training Center, Modesto Junior College, 2002 Edition

• Engineer Training Program, Tiburon Fire District, 2001 Edition • Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition • Fire Fighting Hydraulics, Purington, First Edition • Fire Service Instructor's Manual, Waterous Pump Company, 1996 Edition • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009

Edition • NFPA 1451: Standard for a Fire Service Vehicle Operations Training Program, 2007

Edition

RETIRED C

URRICULU

M

Page 13: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Texts and References Page x

• NFPA 1500: Standard on Fire Department Occupational Safety and Health Program, 2007 Edition

• NFPA 1582: Standard on Comprehensive Occupational Medical Program for Fire Departments, 2007 Edition

• NFPA 1901: Standard for Automotive Fire Apparatus, NFPA, 1999 Edition • NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive

Fire Apparatus, 2007 Edition • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition • Title 49 CFR Transportation, U.S. Government Printing Office, October 2006 Edition • Type III Training Manual, Rincon Valley Fire District, 2002 Edition

RETIRED C

URRICULU

M

Page 14: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Calendar of Events Page xi

Calendar of Events

DAY TOPIC TITLE TIME ACTIVITY EVALUATION 1-1 Orientation And Administration 1:30 1-1-1

1-2 Fire Apparatus Driver/Operator Responsibilities 0:30

2-1 Types Of Fire Pumps 0:45 2-2 Pump Mounting And Drive Arrangements 0:30 2-3 Pump Piping And Valves 0:15 2-4 Automatic Pressure Control Devices 0:15 2-5 Priming Devices 0:15 2-6 Pump Panel Instrumentation 0:15 2-7 Auxiliary Cooling Devices 0:15 3-1 Basic Hydraulic Terminology And Symbols 0:30 3-2 Mathematics Review 1:00 3-2-1

3-3 Characteristics Of Water And Principles of Pressure 0:30

3-4 Principle Features Of Water Systems 0:15 3-5 Nozzle Theory 0:30 3-6 Calculating Gallons Per Minute 0:30 3-6-1 3-7 Principles Of Friction Loss 0:15

Day 1

Day 1 Total 8:00

3-8 Friction Loss Formulas And Calculations 4:00 3-8-1 3-9 Pump Discharge Pressure 0:30 3-9-1

1:00 Test 1 3-10 Fireground Hydraulic Calculations 1:00 3-10-1 4-1 Inspecting The Pump Drive Systems 0:15 4-2 Inspecting The Priming Pump Systems 0:15

4-3 Inspecting The Pump Pressure Control Systems 0:15

4-4 Pump Service Testing 0:45

Day 2

Day 2 Total 8:00

4-5 Maintenance Of The Pump And Control Systems 1:00

0:30 Test 2 5-1 Making The Pump Operational (From Tank) 0:30 5-2 Transitioning To An External Water Supply 0:30 5-3 Operating From A Hydrant 0:30

5-4 Principles And Practices Of Drafting Operations 0:30

5-5 Principles Of Relay Pump Operations 1:30 5-6 Troubleshooting Pump Operations 1:00 5-6-1

Day 3

5-7 Principles Of Tandem Pumping Operations 0:15

RETIRED C

URRICULU

M

Page 15: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Calendar of Events Page xii

DAY TOPIC TITLE TIME ACTIVITY EVALUATION 5-8 Principles Of Dual Pumping Operations 0:15

5-9 Principles And Practices Of Foam Operations 1:00

5-10 Sprinkler And Standpipe Support 0:30 Day 3 Total 8:00 0:30 Test 3

6-1 Introduction To The Mandatory Pumping Exercises 0:30

Operating From Draft Exercise 6-1-1 Operating Using A Forward Lay Exercise 6-1-2 Operating Using A Reverse Lay Exercise

7:00 6-1-3

Day 4

Day 4 Total 8:00

Practice Pumping Exercises Graded Exercises

6:00 Performance Exams

Review And Certification Exam 2:00 Certification Exam Day 5

Day 5 Total 8:00 *Mandatory Pumping Exercises

RETIRED C

URRICULU

M

Page 16: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 1

TOPIC: 1-1: Orientation And Administration

TIME FRAME: 1:30

LEVEL OF INSTRUCTION: Level I

AUTHORITY: 2009 NFPA 1002: Chapters 1 and 4

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and oral evaluation

Behavior: The student will confirm knowledge of the course objectives by completing the activity and oral evaluation

Standard: To the instructor's satisfaction according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 1-8 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 1-10

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Progress chart • Individual Activity 1-1-1: Math Skills Pretest

REFERENCES: • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition, Chapters 1 and 4

• NFPA 1451: Standard for a Fire Service Vehicle Operations Training Program, 2007 Edition

• NFPA 1500: Fire Department Occupational Safety and Health Program, 2007 Edition, Chapter 6

• NFPA 1582: Standard on Medical Requirements for Fire Fighters, 2007 Edition

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition

• Pumping Apparatus Driver/Operator Handbook, IFSTA, First Edition, Pages 1-10

PREPARATION: Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

RETIRED C

URRICULU

M

Page 17: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 2

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 18: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 3

SLIDE: 1-1-1 I. INTRODUCTIONS

A. Introduce self and staff B. Cite background

1. Fire department experience 2. Education 3. Training 4. Teaching history 5. Instructor phone number(s)

Have the students introduce themselves. SLIDE: 1-1-2

C. Student Introductions NOTE: Announce that if there is a student with any special

needs to see the instructor in private. SLIDE: 1-1-3

II. COURSE PREREQUISITES A. California drivers license

1. Class B 2. Fire fighter restricted (minimum)

B. Fire Fighter I training recommended III. FACILITIES ORIENTATION

A. Classroom location(s) B. Restrooms C. Food locations D. Smoking E. Breaks F. Telephones G. Parking

RETIRED C

URRICULU

M

Page 19: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 4

IV. STUDENT REGISTRATION A. Forms

1. State Fire Training 2. College

NOTE: Provide step-by-step directions for completing the forms.

B. Resolve any tuition issues as needed SLIDE: 1-1-4

V. STUDENT EVALUATION A. Activities

1. Complete all activities B. Three written unit tests

1. Each followed with group discussion 2. All tests must be completed and passed with a

minimum score of 80% NOTE: Tests must be returned to the instructor after review.

C. Pumping exercises 1. Manipulative skills tracking and accountability 2. Minimum score of 80% required to pass each

mandatory manipulative performance test D. Progress chart

1. Use student identification numbers a) No names

2. Federal law prohibits publication of identifiable student grades

SLIDE: 1-1-5 E. State certification exam

1. Not related to final course grade 2. Must pass the class first before taking the exam 3. 50 question multiple-choice exam 4. Minimum 70% required to pass the cert exam

RETIRED C

URRICULU

M

Page 20: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 5

SLIDE: 1-1-6 VI. COURSE DESCRIPTION

A. 40-hour class 1. Classroom information and activities 2. Reading assignments 3. Apparatus inspection 4. Hands-on pumping exercises

B. Identify start and end times 1. Class will begin on time 2. Student attendance requirements

a) Must attend the entire course b) State Fire Training allows considerations for

excused absences up to four hours C. Proper attire

1. Classroom a) Station wear or equivalent b) Station boots or equivalent

2. Field exercises a) Station wear or equivalent b) Station boots or equivalent c) Helmet d) Gloves

D. Required textbooks 1. Pumping Apparatus Driver/Operator Handbook,

IFSTA, Second Edition 2. Student supplement published by State Fire

Training SLIDE: 1-1-7

VII. COURSE OBJECTIVES A. Provide the students with

1. Information on pump construction and theory of pump operations

RETIRED C

URRICULU

M

Page 21: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 6

2. Information on methods for performing basic hydraulics

3. Information and techniques on basic inspections, documentation, maintenance, testing, and troubleshooting fire pumps

4. The opportunity to increase their pumping skills during simulated pumping conditions

VIII. HISTORICAL OVERVIEW A. Course development

1. First as a career development guide 2. 1988, two courses were developed

a) Fire Apparatus Driver/Operator 1A 1) Emergency Vehicle Operations

b) Fire Apparatus Driver/Operator 1B 1) Pump Operations

c) 2003, courses were updated d) 2008, courses were updated to meet the

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition

SLIDE: 1-1-8 B. Experience has demonstrated that the following skills

and senses are needed to be a successful fire apparatus driver/operator 1. Reading

a) Able to read and understand the written word 2. Writing

a) Ability to write clearly and concisely 3. Mathematics

a) Basic mathematical skills for Fire Apparatus Driver/Operator 1A

b) Basic algebra skills necessary for hydraulics in Fire Apparatus Driver/Operator 1B

4. Physically fit a) Per department standards

RETIRED C

URRICULU

M

Page 22: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 7

5. Vision NOTE: NFPA 1582: Standard on Comprehensive

Occupational Medical Program for Fire Departments, 2007 Edition, Section 6.4

a) Category A medical condition 1) Far visual acuity less than 20/40 binocular,

corrected with contact lenses or spectacles, or far visual acuity less than 20/100 binocular for wearers of hard contacts or spectacles, uncorrected

2) Color perception

• Monochromatic vision resulting in inability to use imaging devices such as thermal imaging cameras

3) Monocular vision 4) Any eye condition that results in the

candidate not being able to safely perform one or more of the essential job tasks

b) Category B medical condition 1) Diseases of the eye such as retinal

detachment, progressive retinopathy, or optic neuritis

2) Ophthalmological procedures such as radial keratotomy, Lasik procedure, or repair of retinal detachment

3) Peripheral vision in the horizontal meridian of less than 110 degrees in the better eye or any condition that significantly affects peripheral vision in both eyes

6. Ears and hearing NOTE: NFPA 1582: Standard on Comprehensive

Occupational Medical Program for Fire Departments, 2007 Edition, Section 6.5

a) Category A medical condition 1) Chronic vertigo or impaired balance as

demonstrated by the inability to tandem

RETIRED C

URRICULU

M

Page 23: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 8

gait walk 2) On audiometric testing, average hearing

loss in the unaided better ear greater than 40 decibels (dB) at 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz when the audiometric device is calibrated to ANSI Z24.5, Audiometric Device Testing

3) Any ear condition (or hearing impairment) that results in the candidate not being able to safely perform one or more of the essential job tasks

b) Category B medical condition 1) Unequal hearing loss 2) Average uncorrected hearing deficit at the

test frequencies 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz greater than 40 dB in either ear

SLIDE: 1-1-9 7. Mechanical ability

a) To understand the operation and maintenance of apparatus

8. Basic supervisory skills 9. Ability to remain calm 10. Ability to avoid "tunnel vision" 11. Ability to identify safety hazards

IX. APPLICABLE STANDARDS SLIDE: 1-1-10

A. NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, NFPA, 2009 Edition 1. Chapter 1: Administration 2. Chapter 4: General Requirements 3. Chapter 5: Apparatus Equipped with Fire Pump 4. Appendix A: Explanatory Material

RETIRED C

URRICULU

M

Page 24: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 9

SLIDE: 1-1-11 B. NFPA 1911: Inspection, Maintenance, Testing, and

Retirement of In-Service Automotive Fire Apparatus, NFPA, 2007 Edition 1. Chapter 1 Administration 2. Chapter 4 General Requirements 3. Chapter 5 Retirement of Fire Apparatus 4. Chapter 6 Out-of-service Criteria 5. Chapters 7-15 Inspection and Maintenance 6. Chapter 16 Road Tests and Annual Weight

Verification 7. Chapters 17-23 Performance Testing

SLIDE: 1-1-12 C. NFPA 1451: Standard for a Fire Service Vehicle

Operations Training Program, NFPA, 2007 Edition 1. Chapter 1: Administration 2. Chapter 4: General Rules and Considerations 3. Chapter 5: Training and Education 4. Chapter 6: Laws and Liabilities 5. Chapter 10: Vehicle and Apparatus Care

SLIDE: 1-1-13 D. NFPA 1500: Fire Department Occupational Safety and

Health Program, NFPA, 2007 Edition 1. Chapter 6: Fire Apparatus, Equipment, and

Driver/Operators E. Other standards

1. Departmental SLIDE: 1-1-14

X. RELEVANCE OF STANDARDS A. Legal

1. Nationally recognized

RETIRED C

URRICULU

M

Page 25: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-1: Orientation And Administration Page 10

2. Upheld in court a) Liability b) Held personally accountable

3. Negligence/liability a) Possible affects

1) Driving record 2) Personal insurance 3) Career impact

ACTIVITY 1-1-1: Complete the activity in the student supplement.

NOTE: Administer the pretest. Review the results before teaching Topic 3-2 to assess the students' basic math levels.

RETIRED C

URRICULU

M

Page 26: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 11

SUMMARY: The professional fire apparatus driver/operator must recognize his or her role in the fire service and the responsibility that entails. The ability to remain calm, think clearly, and act decisively with intent are just part of the traits that are critical for this position. EVALUATION: The student will complete the activity and oral evaluation at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 1-8 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 1-10 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 27: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 12

BEGINNING DATE: DRIVER/OPERATOR 1B PROGRESS CHART ENDING DATE:

CLASS SIZE LIMITED TO 25 STUDENTS

STUDENT IDENTIFICATION Act

ivity

1

-1-1

1 A

ctiv

ity

3-2

-1

Act

ivity

3

-6-1

A

ctiv

ity

3-8

-1

Act

ivity

3

-9-1

A

ctiv

ity

3-10

-1

Act

ivity

5-

6-1

Exer

cise

6

-1-1

Ex

erci

se

6-1

-2

Exer

cise

6

-1-3

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

RETIRED C

URRICULU

M

Page 28: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 13

BEGINNING DATE: DRIVER/OPERATOR 1B PROGRESS CHART ENDING DATE:

CLASS SIZE LIMITED TO 25 STUDENTS

STUDENT IDENTIFICATION Test

#1

Test

#2

Test

#3

Atte

ndan

ce

Day

1

Atte

ndan

ce

Day

2

Atte

ndan

ce

Day

3

Atte

ndan

ce

Day

4

Atte

ndan

ce

Day

5

PASS

/FA

IL

Cer

t Exa

m

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

RETIRED C

URRICULU

M

Page 29: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 14

INDIVIDUAL ACTIVITY 1-1-1

TITLE: Basic Math Skills

TIME FRAME: 0:30

MATERIALS NEEDED: • Calculator • Square root chart • Pen or pencil

INTRODUCTION: This activity provides the students the opportunity to become familiar with or sharpen their math skills as they relate to fire hydraulics.

DIRECTIONS: 1. Complete Sections I, II, III, and IV. 2. You have 15 minutes to complete this activity. 3. Be prepared to discuss your answers with the class.

SECTION I: CALCULATE THE FOLLOWING EQUATIONS

Whole Numbers 1. 18426 + 21575 40001 2. 95360 – 77469 17891 3. 156 x 38 5928 4. (128)(15) 1920 5. 352 ÷ 32 11 6. 4410/21 210

Decimals

7. 34.3 + 18.66 52.96

8. 29.05 – 6.1 22.95

9. 34.3 x 3.3 113.19

10. (2124.002)(10) 21240.02

11. 36.3 ÷ 3.3 11

12. 2124.002/10 212.4002

RETIRED C

URRICULU

M

Page 30: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 15

Fractions 13. 1/4 + 1/2 3/4 2/8 + 2/4 14. 1/4 – 1/8 1/8 2/8 – 1/8 15. 3/4 x 1/2 3/8 3 x 1/4 x 2 16. 1/4 ÷ 1/2 1/2 2/8 x 2/1

Percentages 17. 10% of 100 10 .10 x 100 18. 15% of 200 30 .15 x 200 19. 3/8 = _____% 24 .3 x 80

Proportion What is the value of x? 20. 1 2 x = 4 1(x) = (2)(2)

2 = x 1x = 4 Square Root 21. √ 9 3 see chart

22. √ 15 3.8730 see chart

23. √ 50 7.0711 see chart

24. √ 246 15.6844 see chart Numbers Squared 25. 72 49 7 x 7 26. 122 144 12 x 12 27. 162 256 16 x 16 28. 462 2,116 46 x 46 29. 1122 12,544 112 x 112

RETIRED C

URRICULU

M

Page 31: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 16

SECTION II: CONVERT THE FOLLOWING FRACTIONS TO A DECIMAL

30. 3/8 .0375 3 ÷ 8

31. 5/8 .625 5 ÷ 8

32. 1/16 .0625 1 ÷ 16

33. 3/4 .75 3 ÷ 4

34. 2/3 .667 2 ÷ 3

SECTION III: CALCULATE THE AREA OF EACH CIRCLE Round your answer to the nearest whole number.

35. Diameter = 6 feet 28 3.14 x 32

3.14 x 9

36. Diameter = 8 feet 50 3.14 x 42

3.14 x 16

37. Diameter = 14 feet 154 3.14 x 72

3.14 x 49

38. Diameter = 28 feet 615 3.14 x 142

3.14 x 196

39. Radius = 16 feet 804 3.14 x 162

3.14 x 256

SECTION IV: CALCULATE THE CAPACITY OF EACH CYLINDER TANK (IN GALLONS) Round your answer to the nearest whole number.

40. Diameter = 3 feet Length = 14 feet 756

(32 x 6)(14) (9 x 6)(14) (54)(14)

41. Diameter = 10 feet Length = 12 feet 7,200

(102 x 6)(12) (100 x 6)(12) (600)(12)

42. Diameter = 15 feet Length = 40 feet 54,000

(152 x 6)(40) (225 x 6)(40) (1,350)(40)

43. Diameter = 20 feet Length = 4 feet 9,600

(202 x 6)(4) (400 x 6)(4) (2,400)(4)

44. Diameter = 25 feet Length = 8 feet 30,000

(252 x 6)(8) (625 x 6)(8) (3,750)(8)

RETIR

ED CURRIC

ULUM

Page 32: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-1: Orientation And Administration Page 17

Square Roots of Numbers 1-250

n n n n n 1 1.000 51 7.1414 101 10.0499 151 12.2882 201 14.1774 2 1.414 52 7.2111 102 10.0995 152 12.3288 202 14.2127 3 1.732 53 7.2801 103 10.1489 153 12.3693 203 14.2478 4 2.000 54 7.3485 104 10.1980 154 12.4097 204 14.2829 5 2.236 55 7.4163 105 10.2470 155 12.4499 205 14.3178 6 2.449 56 7.4833 106 10.2956 156 12.4900 206 14.3527 7 2.646 57 7.5498 107 10.3441 157 12.5300 207 14.3875 8 2.828 58 7.6158 108 10.3923 158 12.5698 208 14.4222 9 3.000 59 7.6811 109 10.4403 159 12.6095 209 14.4568 10 3.162 60 7.7460 110 10.4881 160 12.6491 210 14.4914 11 3.3166 61 7.8102 111 10.5357 161 12.6886 211 14.5258 12 3.4641 62 7.8740 112 10.5830 162 12.7279 212 14.5602 13 3.6056 63 7.9373 113 10.6301 163 12.7671 213 14.5945 14 3.7417 64 8.0000 114 10.6771 164 12.8062 214 14.6287 15 3.8730 65 8.0623 115 10.7238 165 12.8452 215 14.6629 16 4.0000 66 8.1240 116 10.7703 166 12.8841 216 14.6969 17 4.1231 67 8.1854 117 10.8167 167 12.9228 217 14.7309 18 4.2426 68 8.2462 118 10.8628 168 12.9615 218 14.7648 19 4.3589 69 8.3066 119 10.9087 169 13.0000 219 14.7986 20 4.4721 70 8.3666 120 10.9545 170 13.0384 220 14.8324 21 4.5826 71 8.4261 121 11.0000 171 13.0767 221 14.8661 22 4.6904 72 8.4853 122 11.0454 172 13.1149 222 14.8997 23 4.7958 73 8.5440 123 11.0905 173 13.1529 223 14.9332 24 4.8990 74 8.6023 124 11.1355 174 13.1909 224 14.9666 25 5.0000 75 8.6603 125 11.1803 175 13.2288 225 15.0000 26 5.0990 76 8.7178 126 11.2250 176 13.2665 226 15.0333 27 5.1962 77 8.7750 127 11.2694 177 13.3041 227 15.0665 28 5.2915 78 8.8318 128 11.3137 178 13.3417 228 15.0997 29 5.3852 79 8.8882 129 11.3578 179 13.3791 229 15.1327 30 5.4772 80 8.9443 130 11.4018 180 13.4164 230 15.1658 31 5.5678 81 9.0000 131 11.4455 181 13.4536 231 15.1987 32 5.6569 82 9.0554 132 11.4891 182 13.4907 232 15.2315 33 5.7446 83 9.1104 133 11.5326 183 13.5277 233 15.2643 34 5.8310 84 9.1652 134 11.5758 184 13.5647 234 15.2971 35 5.9161 85 9.2195 135 11.6190 185 13.6015 235 15.3297 36 6.0000 86 9.2736 136 11.6619 186 13.6382 236 15.3623 37 6.0828 87 9.3274 137 11.7047 187 13.6748 237 15.3948 38 6.1644 88 9.3808 138 11.7473 188 13.7113 238 15.4272 39 6.2450 89 9.4340 139 11.7898 189 13.7477 239 15.4596 40 6.3246 90 9.4868 140 11.8322 190 13.7840 240 15.4919 41 6.4031 91 9.5394 141 11.8743 191 13.8203 241 15.5242 42 6.4807 92 9.5917 142 11.9164 192 13.8564 242 15.5563 43 6.5574 93 9.6437 143 11.9583 193 13.8924 243 15.5885 44 6.6332 94 9.6954 144 12.0000 194 13.9284 244 15.6205 45 6.7082 95 9.7468 145 12.0416 195 13.9642 245 15.6525 46 6.7823 96 9.7980 146 12.0830 196 14.0000 246 15.6844 47 6.8557 97 9.8489 147 12.1244 197 14.0357 247 15.7162 48 6.9282 98 9.8995 148 12.1655 198 14.0712 248 15.7480 49 7.0000 99 9.9499 149 12.2066 199 14.1067 249 15.7797 50 7.0711 100 10.0000 150 12.2474 200 14.1421 250 15.8114

n n n n n

RETIRED C

URRICULU

M

Page 33: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 1

TOPIC: 1-2: Fire Apparatus Driver/Operator Responsibilities

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of fire apparatus driver/operator responsibilities by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in the Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 9-10 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 1-20, 31-54, 99-131

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1451: Standard for a Fire Service Vehicle Operations Training Program, 2007 Edition, Chapter 5

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapters 1-4

• Pumping Apparatus Driver/Operator Handbook. IFSTA, Second Edition, Pages 1-20, 31-54, 99-131

• Title 49 CFR Transportation, U.S. Government Printing Office, October 2006 Edition, Part 396

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss

RETIRED C

URRICULU

M

Page 34: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 2

incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 35: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 3

SLIDE: 1-2-1 SLIDE: 1-2-2

I. SAFETY A. Personnel/apparatus riders

1. Remain seated 2. Wear seatbelts 3. Have a spotter

B. Public 1. Use caution with general public around apparatus

C. Driving (emergency and nonemergency) SLIDE: 1-2-3

D. Operating apparatus 1. Scene

a) Apparatus positioning What are some considerations when positioning your apparatus at an incident?

1) Building collapse 2) Electrical hazards 3) Hydrant locations 4) Other apparatus access

b) Hose lines 1) Attack 2) Supply

c) Electrical hazards 1) Generators and cords 2) Downed wires

d) Equipment 1) Doors left open 2) Ladder rack down 3) Tools not secured or stored

RETIRED C

URRICULU

M

Page 36: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 4

SLIDE: 1-2-4 E. Station

1. Apparatus bay doors 2. Compartment doors open 3. Shorelines

SLIDE: 1-2-5 II. DISTRICT KNOWLEDGE

What might you want to know about your district?

A. Response routes 1. Commercial verses residential areas

B. Target hazards C. Access problems

SLIDE: 1-2-6 D. Water supply and distribution systems

1. Water sources a) Natural b) Fabricated

2. Gravity/pump 3. Hydrants 4. Draft locations

SLIDE: 1-2-7 III. APPARATUS INSPECTION

When do we inspect? A. Daily

1. Required by law a) Title 49 CFR, Part 396: Inspection, Repair, and

Maintenance 2. Types of inspection

a) Pretrip b) Posttrip

RETIRED C

URRICULU

M

Page 37: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 5

B. Weekly/monthly 1. Not required by law 2. Per department SOPs 3. In accordance with the manufacturer's

recommendations and specifications C. Written documentation

When should written documentation be completed?

1. Completed daily 2. Title 49 CFR, Part 396 3. Per department SOPs

D. Out-at-service criteria 1. Per department SOPs 2. In accordance with the manufacturer's

recommendations and specifications 3. NFPA 1911: Inspection, Maintenance, Testing, and

Retirement of In-Service Automotive Fire Apparatus, 2007 Edition

SLIDE: 1-2-8 IV. APPARATUS MAINTENANCE

A. Regulated by Code of Federal Regulations 1. Title 49 CFR, Part 396

B. Daily 1. Required by law

a) Title 49 CFR, Part 396 2. Per department SOPs 3. In accordance with the manufacturer's

recommendations and specifications C. Weekly/monthly

1. Per department SOPs 2. In accordance with the manufacturer's

recommendations and specifications

RETIRED C

URRICULU

M

Page 38: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 6

D. Written documentation 1. Title 49 CFR, Part 396 2. Per department SOPs

SLIDE: 1-2-9 V. OPERATION

A. Spot apparatus accordingly B. Operate pump and associated components C. Secure a water supply D. Produce and maintain effective fire streams

SLIDE: 1-2-10 VI. TRAINING

A. Ongoing 1. NFPA 1451: Standard for a Fire Service Vehicle

Operations Training Program, 2007 Edition a) Chapter 5: Training and Education

1) 5.2.1: On-going training must be provided 2) 5.2.3: Appropriate training and education

must take place when changes in procedures and/or technology occur

2. Per department SOPs B. Mentoring/instructing

1. Assist interested personnel

RETIRED C

URRICULU

M

Page 39: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 1-2: Fire Apparatus Driver/Operator Responsibilities Page 7

SUMMARY: The importance of accepting the responsibility inherent with the position of fire apparatus driver/operator cannot be understated. Knowing all the elements of your apparatus, driving regulations, response district, water supply systems, and pump operations is part of the overall responsibility of the professional fire apparatus driver/operator. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 9-10 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 1-20, 31-54, 99-131 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 40: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-1: Types Of Fire Pumps Page 1

TOPIC: 2-1: Types Of Fire Pumps

TIME FRAME: 0:45

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of the types of fire pumps by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 266-281

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 266-281

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 41: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 2

SLIDE: 2-1-1 SLIDE: 2-1-2

I. TYPES OF FIRE PUMPS SLIDE: 2-1-3

A. Positive displacement SLIDE: 2-1-4

B. Centrifugal SLIDE: 2-1-5

II. POSITIVE DISPLACEMENT PUMPS What is the biggest advantage of a positive displacement pump?

A. The biggest advantage is that it can pump air B. Has a small amount of slippage

1. Slippage is defined as the ability of water to pass through the inner workings of the pump, not allowing 100% discharge

C. Has a fixed displacement of water SLIDE: 2-1-6

D. Types SLIDE: 2-1-7

1. Piston pumps a) Single action

1) Pumps in a forward stroke only b) Double action

1) Pumps in both forward and reverse strokes What are some different examples of a piston pump?

c) Examples 1) Backpack pump

RETIRED C

URRICULU

M

Page 42: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 3

2) Foam injection pump 3) Wells 4) Bicycle pump

SLIDE: 2-1-8 SLIDE: 2-1-9

2. Rotary pumps a) Commonly used in the fire service as a primer

pump b) Rotary gear

1) Two gears that rotate in a tightly meshed pattern forming pockets

2) As each gear tooth reaches the discharge chamber, the air or water contained in that pocket is forced out of the pump

SLIDE: 2-1-10 SLIDE: 2-1-11

c) Rotary vane 1) Movable vanes that automatically

compensate for wear and maintain a tighter fit

2) Vanes are forced against the outer housing by centrifugal force

SLIDE: 2-1-12 SLIDE: 2-1-13

III. CENTRIFUGAL PUMPS Can a centrifugal pump actually pump air?

A. Cannot pump air B. Capable of 100% slippage C. The main fire pump used on modern fire apparatus D. Classified as a nonpositive displacement pump E. Imparts velocity on water and converts it to pressure

RETIRED C

URRICULU

M

Page 43: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 4

F. Types 1. Single stage 2. Multi-stage

SLIDE: 2-1-14 G. Components

1. Intake 2. Impeller

a) Eye b) Hub c) Shroud d) Vanes

3. Casing a) Volute

4. Discharge 5. Shaft

a) Drives impeller 6. Transfer valve

a) Flap valve, clapper valve, or swing valve SLIDE: 2-1-15 SLIDE: 2-1-16 SLIDE: 2-1-17

7. Pump wear rings a) Located between the pump casing and the hub b) Seal between the lower pressure of the intake

side and the higher pressure in the volute c) Dirt and sediment can damage ring resulting in

decreased pump effectiveness 1) Can be replaced

SLIDE: 2-1-18

RETIRED C

URRICULU

M

Page 44: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 5

8. Pump packing a) Located around the pump shaft, within the

stuffing box b) Lubricates and seals pump shaft c) Too loose

1) Can result in drafting difficulties and pump efficiency

d) Too tight 1) Can result in damaging the pump shaft due

to overheating e) Can be replaced f) Should be adjusted by a qualified technician

SLIDE: 2-1-19 H. Principles of operation

1. Centrifugal force What is centrifugal force?

a) An outward force on a body rotating about an axis

2. The operation of a centrifugal pump is based on the principle that a rapidly revolving impeller hurls the water from the impeller eye outward

3. The faster the impeller is turned, the farther the water is thrown thus increasing the velocity

4. The casing collects the water and confines it in order to convert velocity to pressure, then directs the water to the discharge

SLIDE: 2-1-20 SLIDE: 2-1-21

5. Influencing factors of discharge pressure a) Amount of water being discharged b) Speed at which the impeller is turning

1) Doubling the speed results in four times the pressure

c) Pressure of water when it enters the pump from a pressurized source

RETIRED C

URRICULU

M

Page 45: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 6

6. Transfer valve settings SLIDE: 2-1-22

a) Series (pressure position) 1) Definition

• The operation of a multistage centrifugal pump in which water passes consecutively through each impeller to provide high pressure at reduced volume

When is higher pressure required?

2) Uses

• Long hose lay

• To overcome effects of head pressure due to uphill hose lay

• Handline operations 3) Normal operating position

SLIDE: 2-1-23 SLIDE: 2-1-24

b) Parallel (volume position) 1) Definition

• The operation of a multistage centrifugal pump in which each impeller discharges into a common outlet, thereby providing greater flow rate at reduced pressure

• Sometimes called "capacity operation" When might you use parallel operation?

2) Uses

• Master stream operations

• Multiple handlines

• Pump certification tests

RETIRED C

URRICULU

M

Page 46: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-1: Types Of Fire Pumps Page 7

3) Used when water flow exceeds 50% of rated capacity

SLIDE: 2-1-25

c) Net pump pressure should not exceed 50 psi when changing from volume to pressure or pressure to volume

RETIRED C

URRICULU

M

Page 47: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-1: Types Of Fire Pumps Page 8

SUMMARY: Understanding the construction and uses of the various types of fire pumps is imperative to providing a continuous, uninterrupted, and effective fire stream. While the actual method of changing from SERIES to PARALLEL can vary from manufacturer to manufacturer, the basic principles remain the same. In series operation, the water goes from one impeller to the next. In parallel operation, the water goes through all impellers at the same time. Change over from one mode to another must be done carefully. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 266-281 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 48: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-2: Pump Mounting And Drive Arrangements Page 1

TOPIC: 2-2: Pump Mounting And Drive Arrangements

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of pump mounting and drive arrangements by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 280-285

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 280-285

• Type III Training Manual, Rincon Valley Fire District, 2002 Edition, Pages 10-15

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 49: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 2

SLIDE: 2-2-1 SLIDE: 2-2-2

I. SIX METHODS OF TRANSMITTING POWER TO THE PUMP A. Auxiliary engine B. Power take-off C. Front-mount D. Midship transfer E. Rear-mount F. Hydrostatic

SLIDE: 2-2-3 II. AUXILIARY ENGINE DRIVEN PUMPS

A. Auxiliary engine-driven pumps are those pumps that are powered by a gasoline or diesel engine independent of an engine used to drive the vehicle 1. Portable 2. Skid-mount 3. Permanent mounting 4. Examples

a) Airport rescue and fire fighting (ARFF) vehicles b) Wildland fire apparatus c) Mobile water supply apparatus d) Trailer-mounted fire pumps e) Portable fire pumps

SLIDE: 2-2-4 SLIDE: 2-2-5 What are the advantages of independent engine driven pumps? SLIDE: 2-2-6

RETIRED C

URRICULU

M

Page 50: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 3

B. Advantages 1. Pump speed independent of vehicle speed 2. Pump and roll capability 3. Pump can be carried to a source of water

What are the disadvantages of independent engine driven pumps?

C. Disadvantages 1. Limited pressure and capacity 2. Additional engine to maintain 3. Extra supply of fuel, or two types of fuel

SLIDE: 2-2-7 III. POWER TAKE-OFF PUMPS

A. Gear assembly mounted on the side of the transmission 1. Limited to 35 horsepower due to torque limitations

and/or 500 gpm 2. Caused by the physical limits of the transmission

housing B. Flywheel mounted

1. Full torque application and/or 1,250 gpm 2. Directly connected to engine flywheel

SLIDE: 2-2-8 C. Advantages

1. Pump and roll capabilities 2. Pumps for different applications

a) Midship pump b) Booster pump

D. Disadvantages 1. Pump size limited unless flywheel mounted

RETIRED C

URRICULU

M

Page 51: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 4

SLIDE: 2-2-9 IV. FRONT-MOUNT PUMPS

A. Power is supplied through a coupling and/or clutch arrangement attached to crankshaft 1. Transmitted to gear box that steps up the pump

shaft rpm a) Pump speed runs faster than engine speed

B. Generally mounted between the frame rails and in front of grill

SLIDE: 2-2-10 What are some advantages of a front mount pump? SLIDE: 2-2-11

C. Advantages 1. Simplified Iinkage and controls 2. Pump is independent of drive wheels 3. Can pump while moving

What are the disadvantages of a front mount pump?

D. Disadvantages 1. Size of pump is limited 2. While moving, pump discharge depends on engine

speed 3. Components are susceptible to freezing

SLIDE: 2-2-12 V. MIDSHIP PUMPS

A. Also known as split-shaft pumps B. Most common application in fire service RETIR

ED CURRIC

ULUM

Page 52: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 5

What is the power source for a midship pump?

1. Power source is main engine in the vehicle 2. Power is transmitted from the engine through the

vehicle transmission to the pump gearbox 3. When the pump is engaged, power is redirected

from the rear axle to fire pump SLIDE: 2-2-13

C. Pump engagement 1. Either electrically, manually, air actuated or

vacuum operated 2. Most common method uses a sliding collar in the

pump transmission 3. Speedometer may read between 10-15 mph if in

proper gear 4. Manual transmissions

a) Clutch b) Gear selection – manufacturer's

recommendations 5. Automatic transmissions

a) Gear selection – manufacturer's recommendations

What keeps the transmission from shifting while in pump?

b) Transmission lock-outs 1) Transmission starts in pump gear instead

of shifting up through the gears 6. Manually engage/disengage pump

a) See manufacture recommendations RETIRED C

URRICULU

M

Page 53: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 6

What are some advantages of the midship pump operation? SLIDE: 2-2-14

D. Advantages 1. Full engine power is available 2. Pump size is unlimited, depending on horsepower

available from the engine E. Disadvantages

1. Power to rear wheels is disconnected 2. Complex mechanical operation 3. Need a backup system to engage pump

SLIDE: 2-2-15 SLIDE: 2-2-16

VI. REAR-MOUNT PUMPS A. Pump located in rear of apparatus

1. Powered by either a) Power take-off b) Split-shaft transmission

SLIDE: 2-2-17 B. Advantages

1. Provides weight distribution on chassis 2. Allows for more compartment space

C. Disadvantage 1. Operator exposed to oncoming traffic

NOTE: The following information on hydrostatic driven pumps if for general information only. Students will not be tested on Section VII.

SLIDE: 2-2-18 VII. HYDROSTATIC DRIVEN PUMPS

A. Primarily used on interface engines

RETIRED C

URRICULU

M

Page 54: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 7

B. Powered from a hydraulic pump that is driven directly off the crankshaft of the chassis engine

C. Hydraulic system 1. Four components

a) Hydrostatic pump b) Hydrostatic motor c) Hydraulic reservoir d) Pump control

SLIDE: 2-2-19 D. Hydrostatic pump

1. Mounted behind front bumper and in front of radiator

2. Driven by a drive shaft attached to the crankshaft of the apparatus engine

SLIDE: 2-2-20 SLIDE: 2-2-21

E. Hydrostatic motor 1. Mounted forward of the fire pump between chassis

frame rails 2. Provides the power necessary to turn the pump

shaft of the fire pump SLIDE: 2-2-22 SLIDE: 2-2-23

F. Hydraulic reservoir 1. Mounted adjacent to hydrostatic pump

SLIDE: 2-2-24 G. Pump control

1. Activates the hydraulic system and sets the desired pressure/flow during pumping operations

2. Can be done during stationary and mobile pumping operations

RETIRED C

URRICULU

M

Page 55: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-2: Pump Mounting And Drive Arrangements Page 8

SLIDE: 2-2-25 SLIDE: 2-2-26

H. Operation 1. Stationary pumping

a) Activate high idle switch b) Rotate pump control knob to desired pump

pressure 2. Mobile pumping

a) Rotate pump control valve to desired pump pressure 1) No more than 100 psi

SLIDE: 2-2-27 I. Advantages

1. Pump-and-roll capabilities 2. One of the simplest pump systems to operate

J. Disadvantages 1. Limited to pump size 2. Very noisy

RETIRED C

URRICULU

M

Page 56: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-2: Pump Mounting And Drive Arrangements Page 9

SUMMARY: There are six methods, used in the fire service today, that provide the power necessary to drive fire pumps. This lesson has attempted to cover a great deal of material related to the subject. All of it is critical to ensure a successful operation on the emergency scene. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 280-285 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 57: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-3: Pump Piping And Valves Page 1

TOPIC: 2-3: Pump Piping And Valves

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of pump piping and valves by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 285-293

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 285-293

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 58: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-3: Pump Piping And Valves Page 2

SLIDE: 2-3-1 SLIDE: 2-3-2

I. PIPING AND VALVES A. Intake manifolds and valves B. Discharge manifolds and valves C. Drains

SLIDE: 2-3-3 II. INTAKE MANIFOLD AND VALVES

A. Location of manifolds 1. Cast as integral part of pump case

a) Smooth interior b) No sharp bends c) Rectangular shape

Why do we use rectangular manifolds?

1) To cut down "vortex" turbulence 2. Covers eye of the impeller(s)

SLIDE: 2-3-4 SLIDE: 2-3-5

B. Intakes 1. Large intake

a) Sizes vary by pump capacity b) Bolts on to casting flange c) May or may not be valved d) Usually on eye of the pump

2. Small intake a) Valved b) Enters into large intake c) Usually 2½" female coupling d) May have small plumbing

RETIRED C

URRICULU

M

Page 59: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-3: Pump Piping And Valves Page 3

e) Be sure plumbing size is adequate to provide needed fire flow

f) If not, you must use the large intake SLIDE: 2-3-6 SLIDE: 2-3-7

3. Auxiliary intakes a) Front or rear b) Size varies by apparatus c) Valved d) Due to bends and length of piping, may not

allow the pump to supply its rated capacity SLIDE: 2-3-8

4. Tank suction intake What is the purpose of the tank suction intake?

a) Connects tank to pump b) Bolts to flange on manifold c) Valved

1) Also known as "tank-to-pump valve" d) Has check valve

1) Won't allow water to go back into tank e) Piping should be of sufficient size

1) Pumps rated less than 500 gpm should be capable of flowing 250 gpm from the tank

2) Pumps rated greater than 500 gpm should be capable of flowing 500 gpm from the tank

SLIDE: 2-3-9 RETIRED C

URRICULU

M

Page 60: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-3: Pump Piping And Valves Page 4

SLIDE: 2-3-10 III. DISCHARGE MANIFOLD AND VALVES

A. Locations 1. Water enters discharge manifold

a) From outlet of impeller case(s) b) Usually cast as integral part of pump case c) Made with smooth passages

1) No bends 2) Round passage ways

SLIDE: 2-3-11 SLIDE: 2-3-12

B. Attachment of valves 1. Manufacturers provide attachment "embossments"

in the casting a) Some open b) Some have threaded plugs c) Some need to be drilled out

SLIDE: 2-3-13 SLIDE: 2-3-14

C. Valves and piping 1. Various sizes 2. Size depends on volume of water needed at

discharge device 3. Each discharge will have its own valve 4. Types of valves

What are the different types of valves? SLIDE: 2-3-15

a) Piston SLIDE: 2-3-16

b) Butterfly

RETIRED C

URRICULU

M

Page 61: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-3: Pump Piping And Valves Page 5

SLIDE: 2-3-17 c) Ball

1) ¼ turn d) Gate

SLIDE: 2-3-18 D. Tank filler

What is the tank filler used for?

1. Used to fill tank once attached to water supply a) Do not exceed a loss of 10 psi on the

compound gauge if attack lines are in service 2. Can be used as a circulating valve to keep pump

cool while not flowing water E. Circulating valve

1. Also know as a "churn valve" 2. A small tube that connects the discharge side of

the pump to the tank 3. Opens with a valve on the pump panel 4. Used to keep pump from overheating 5. Normally left open/on at all times

a) Unless drafting SLIDE: 2-3-19

IV. DRAINS A. Drains are used to relieve or remove pressure or water

from 1. Suction intakes 2. Discharges 3. Main pumps

SLIDE: 2-3-20 B. Bleeder lines

1. Used to bleed air from large diameter supply lines to keep air from entering pump

RETIRED C

URRICULU

M

Page 62: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-3: Pump Piping And Valves Page 6

SUMMARY: The intake manifold and valves provide a smooth system of water delivery to the pump. The discharge manifold and valves bring all of the work of the pump together and provide the means to get the water out to the attack lines. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 285-293 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 63: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-4: Automatic Pressure Control Devices Page 1

TOPIC: 2-4: Automatic Pressure Control Devices

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of automatic pressure control devices by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 293-298

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 293-298

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 64: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-4: Automatic Pressure Control Devices Page 2

SLIDE: 2-4-1 SLIDE: 2-4-2

I. TYPES OF PRESSURE CONTROL DEVICES A. Pressure relief valves B. Pressure governor

II. PRESSURE RELIEF VALVES Why do we need pressure relief valves? SLIDE: 2-4-3

A. Purpose 1. Control excessive pressure

a) Protects fire fighters and equipment from water hammer

2. Works on the principle of pressure differential SLIDE: 2-4-4

B. Operation 1. Discharge pressure relief valve

a) Reroutes water from the pressure side of the pump to the inlet side of the pump

b) Adjustable to needed pressure of the attack lines

c) Components 1) Pilot valve/controller

• Controls the relief valve 2) Four-way valve

• On/off valve 3) Relief valve

• Mounted to pump casing SLIDE: 2-4-5 SLIDE: 2-4-6

RETIRED C

URRICULU

M

Page 65: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-4: Automatic Pressure Control Devices Page 3

SLIDE: 2-4-7 2. Intake pressure relief valve

a) Excess pressure from the supply line is exhausted out of system

b) Outlet to open ground c) Some not easily adjustable on demand d) Can be external to pump panel or mounted

internally onto the pump intake manifold SLIDE: 2-4-8

1) External piston valves are added by the department

• Works only when supply line is attached to valve

SLIDE: 2-4-9 2) Internal relief valves is added by the

engine manufacturer

• Works for all intakes III. PRESSURE GOVERNOR

SLIDE: 2-4-10 A. Purpose

1. Control excessive pressure a) Protects fire fighters and equipment from water

hammer B. Operation

How does a pressure governor operate?

1. Controls pump pressure by opening and closing the throttle to the engine a) Electronic b) Manual

SLIDE: 2-4-11

RETIRED C

URRICULU

M

Page 66: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-4: Automatic Pressure Control Devices Page 4

SUMMARY: There are two basic types of pressure control systems: pressure relief valves and pressure governors. Both control excessive pressures that could injure personnel and damage equipment. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 293-298 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 67: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-5: Priming Devices Page 1

TOPIC: 2-5: Priming Devices

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of priming methods and devices by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 298-301

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapters 9 and 18

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 298-301

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 68: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-5: Priming Devices Page 2

SLIDE: 2-5-1 SLIDE: 2-5-2

I. PRIMING DEVICES OVERVIEW Why are priming devices needed?

A. Priming devices are an essential part of centrifugal fire pumps 1. Centrifugal pumps cannot pump air 2. Provides water to the impeller

B. Priming devices operate as the result of air pressure differential 1. Relies on atmospheric pressure 2. Reduces atmospheric pressure within pump cavity

C. Uses 1. Pump tests 2. When drafting 3. When apparatus tank water does not reach fire

pump SLIDE: 2-5-3

D. NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition recommends specific priming device performance 1. Must be able to develop 22 in. Hg (mercury) 2. Must be able to pull a draft within 30 seconds

a) 45 seconds for 1500 gpm or larger fire pumps II. TYPES OF PRIMING DEVICES

SLIDE: 2-5-4 A. Positive displacement pumps

1. Used as primers on centrifugal pumps 2. Rotary gear and rotary vane

RETIRED C

URRICULU

M

Page 69: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-5: Priming Devices Page 3

3. Power sources a) Electric motor b) Mechanically driven off pump transmission

4. Components a) Vanes or gears b) Oil tank

1) Oil provides sealing and lubrication 2) Vent hole in cap

c) Tube with hole to break siphon 1) Known as the anti-siphon hole

SLIDE: 2-5-5 SLIDE: 2-5-6 SLIDE: 2-5-7

B. Vacuum primers Why aren't vacuum primers used on diesel engines?

1. Diesel engines produce no vacuum 2. Gasoline engines create vacuum at intake manifold 3. Connected between pump and intake manifold to

use vacuum when necessary 4. Considerations when using vacuum primers

a) Check valve prevents water from being drawn into engine

b) Check valve prevents gases being forced into the pump

c) If check valves fail, dangerous conditions can result

C. Engine exhaust priming system 1. An integral part of the exhaust system

a) A separate chamber

RETIRED C

URRICULU

M

Page 70: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-5: Priming Devices Page 4

2. Operation How does an exhaust primer work? SLIDE: 2-5-8

a) Venturi principle 1) Works on the same principle as a foam

eductor 2) The gases are diverted to a chamber

where the velocity of the gases passing through a venturi creates a vacuum

b) Relatively high engine rpms are needed SLIDE: 2-5-9

RETIRED C

URRICULU

M

Page 71: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-5: Priming Devices Page 5

SUMMARY: There are three types of priming systems; positive displacement, vacuum, and exhaust. Priming systems are necessary when using centrifugal pumps. The operator must know and understand the purpose and operation of priming systems to be successful on the fire ground. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 298-301 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 72: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-6: Pump Panel Instrumentation Page 1

TOPIC: 2-6: Pump Panel Instrumentation

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of pump panel instrumentation by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 301-307

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1901: Standard for Automotive Fire Apparatus, 2009 Edition, Chapter 16

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 301-307

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 73: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 2

SLIDE: 2-6-1 SLIDE: 2-6-2

I. PUMP PANEL COMPONENTS A. Gauges and indicators B. Throttle control C. Primer control D. Tank level indicators

1. Water 2. Foam

E. Standards and recommendations SLIDE: 2-6-3 SLIDE: 2-6-4 SLIDE: 2-6-5

II. GAUGES AND INDICATORS A. Gauges are an essential part of the pump operators

panel 1. Gauges provide the operator with information on

current operating conditions B. Indicators provide information on the status of other

various systems C. Types of gauges

SLIDE: 2-6-6 1. Analog

a) Bourdon tube 1) As pressure is applied to a curved tube,

the tube will straighten thus moving the indicator dial

SLIDE: 2-6-7 2. Digital

SLIDE: 2-6-8 D. Each gauge furnishes information on a particular

condition

RETIRED C

URRICULU

M

Page 74: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 3

What does the master pump suction gauge indicate?

1. The master pump suction gauge indicates existing conditions on the intake side of the pump impeller a) It indicates vacuum to 30" Hg. and pressure up

to maximum (300-600 psi) b) Also called a compound gauge

2. The master pump discharge pressure gauges indicates current conditions on the discharge side of the pump impeller a) It indicates pressure from zero to maximum

(300-600 psi) 3. Pressure gauges for each 1½" or larger pump

outlet indicate current conditions beyond any valve that can control flow through the outlet a) It indicates pressure in psi from zero to a

maximum reading which conforms with that of the main pump gauge

SLIDE: 2-6-9 4. The engine tachometer indicates the present

engine speed in revolutions per minute 5. The engine oil pressure gauge represents the

current oil pressure of the pump engine 6. The engine coolant temperature gauge registers

the current pump engine coolant temperature 7. The voltage meter monitors the output of the main

engines charging system 8. "OK to Pump" indicates that the pump is engaged,

the chassis transmission is in neutral, and the parking brake is engaged

9. "Pump Engaged" indicates that the pump shift has been successfully completed

SLIDE: 2-6-10

RETIRED C

URRICULU

M

Page 75: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 4

10. "Throttle Ready" indicates the "OK to Pump" indicator is energized or when the chassis transmission is in neutral and the parking brake is engaged

SLIDE: 2-6-11 III. THROTTLE CONTROL

A. Used to increase or decrease the speed of the engine that is powering the pump

B. Types 1. Electronic control 2. Manual control

Why does the operator need to control the engine rpms?

C. Changing the speed of the engine changes the pump pressure

SLIDE: 2-6-12 IV. PRIMER CONTROL

A. Used to operate the primer system B. Types

1. Push button 2. Toggle switch

SLIDE: 2-6-13 3. Pull lever

SLIDE: 2-6-14 V. TANK LEVEL INDICATORS

A. Water tank level 1. Indicates the amount of water that is in the water

tank of the apparatus a) Types

1) Series of lights 2) Clear site tube 3) Digital readouts

RETIRED C

URRICULU

M

Page 76: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 5

Why would knowing the water level be important?

2. Vital to operator supplying attack lines to know when they will run out of water and need an outside water source

B. Foam tank level 1. Used to monitor the amount of foam concentrate in

the foam tank a) Types

1) Series of lights 2) Clear site tube 3) Digital readouts

SLIDE: 2-6-15 SLIDE: 2-6-16

VI. NFPA 1901 STANDARDS AND RECOMMENDATIONS NOTE: From NFPA 1901: Standard For Automotive Fire

Apparatus, NFPA, 2009 Edition, Section 16.12. What gauges must appear on a pump operator's panel? SLIDE: 2-6-17

A. The following controls and instruments shall be provided and installed as a group on the pump operator's panel 1. Master pump intake pressure gauge 2. Master pump discharge pressure gauge 3. Pumping engine tachometer 4. Pumping engine coolant temperature gauge 5. Pumping engine oil pressure gauge 6. Voltmeter 7. Pump pressure control(s) 8. Pumping engine throttle

RETIRED C

URRICULU

M

Page 77: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 6

9. Primer control 10. Water tank–to–pump valve control 11. Water tank fill valve control 12. Water tank level gauge

B. The instruments and controls shall be placed so as to keep the pump operator as far as practicable from all discharge and intake connections and in a location where the instruments and controls are visible and operationally functional while the operator remains stationary

SLIDE: 2-6-18 C. Some gauges require specific placement

1. Master pump intake and pump discharge pressure gauges shall be located within 8 inches of each other, edge to edge a) Intake pressure gauge to the left of or below

the pump discharge pressure gauge SLIDE: 2-6-19

D. Some gauges require a specific size 1. There shall be at least a 1 inch diameter differential

in viewing area between the master gauges and the individual discharge gauges a) The master gauges being the larger

2. Numerals for analog master gauges shall be a minimum of 0.25 inches

3. Digital numerals for the master gauges must have numerals at least ½ inch in height

What special construction features are required of the gauges? SLIDE: 2-6-20

E. Instrumentation exposed to the elements shall be weatherproof

RETIRED C

URRICULU

M

Page 78: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-6: Pump Panel Instrumentation Page 7

F. The pumping engine oil pressure and engine coolant temperature gauges shall be equipped with audible and visual warnings

G. Connections for test gauges shall be provided at the pump operator's panel

RETIRED C

URRICULU

M

Page 79: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-6: Pump Panel Instrumentation Page 8

SUMMARY: The gauges and indicators located at the driver/operator's pump panel serve a key role in providing essential information to the pump operator. This data is used to insure correct pump and engine operating conditions. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 301-307 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 80: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-7: Auxiliary Cooling Devices Page 1

TOPIC: 2-7: Auxiliary Cooling Devices

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Chapter 5

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of auxiliary cooling devices by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 307-309

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1901: Standard for Automotive Fire Apparatus, NFPA, 2009 Edition, Chapter 16

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 307-309

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 81: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-7: Auxiliary Cooling Devices Page 2

SLIDE: 2-7-1 SLIDE: 2-7-2

I. AUXILIARY COOLING DEVICES A. Indirect cooler B. Direct cooler

SLIDE: 2-7-3 II. REASONS FOR AUXILIARY COOLING DEVICES

What are some reasons for auxiliary cooling systems?

A. Stationary pumping 1. Limited air movement over engine 2. On skid mounted pump/engine equipment, main

engine can overheat at idle speed 3. Options/additions to auxiliary coolers

a) Raise idle to 1000-1200 rpm to keep air flow over engine

b) Lift hood or engine compartment to lower engine temperature

B. High ambient temperature 1. Summer temps in excess of 100°F can cause

extreme engine heat C. Off-road pumping

1. Weeds and grain chafe can clog radiator D. Automatic transmissions may become overheated on

pump-and-roll operations E. Low radiator level

1. Coolant level may drop during extended pumping SLIDE: 2-7-4

III. INDIRECT COOLER A. Water from fire pump does not mix with radiator coolant B. Inserted into one of the hoses used in the engine

cooling systems

RETIRED C

URRICULU

M

Page 82: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-7: Auxiliary Cooling Devices Page 3

C. Engaged by opening valve on pump panel a quarter of a turn at a time 1. Water from discharge goes into coil 2. This water absorbs heat from radiator coolant

flowing around the coil of tubing 3. This process is called "heat exchange"

a) Heat transfers from a warm source to a cooler source

4. Water then returns to suction side of the pump D. Should be engaged whenever going off road E. Types

1. Marine a) Engine coolant travels through the tubes b) Pump water surrounds tubes within body

2. Immersion a) Engine coolant travels through the body b) Pump water travels through the tubes

SLIDE: 2-7-5 SLIDE: 2-7-6

IV. DIRECT COOLER A. Water from the pump enters directly into the radiator

1. Sometimes called "radiator filler" a) Used to refill the radiator if the coolant level

drops too low for effective cooling during a pumping operation

b) The radiator fill valve should only be used in an emergency

What is a major disadvantage of the direct cooler?

2. May cause catastrophic failure of radiator due to overpressure

RETIRED C

URRICULU

M

Page 83: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 2-7: Auxiliary Cooling Devices Page 4

3. Remove radiator cap, if this system is to be used 4. After use coolant is contaminated – service or test

B. Engaged by opening valve on pump panel 1. Water flows through tubing on discharge side of the

pump to radiator and then out to the ground C. NFPA 1901: Standard for Automotive Fire Apparatus,

2009 Edition, Section 16.3.5.1 1. States that pump water cannot mix with radiator

fluid a) Still found on older apparatus

RETIRED C

URRICULU

M

Page 84: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 2-7: Auxiliary Cooling Devices Page 5

SUMMARY: Auxiliary coolers can provide additional cooling capacity under extreme operating conditions. The indirect cooler has definite advantages and should be required in some situations. The direct cooler may be useful to add water to the radiator, but must be used with caution. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 307-309 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 85: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 1

TOPIC: 3-1: Basic Hydraulic Terminology And Symbols

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2.1(A)

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of basic hydraulic terminology and symbols by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in the Fire Apparatus Driver/Operator Student Supplement, SFT, 2008 Edition, Pages 18-21 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 571-587

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Driver Operator Training Program, Regional Training Center, Modesto Junior College, 2002 Edition, Basic Terminology Section

• Engineer Training Program, Tiburon Fire District, 2001 Edition, Pages 01-1 and 01-2

• Fire Fighting Hydraulics, Purington, First Edition, Pages 16 and 23

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 571-587

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students

PREPARATION:

Desire (stimulate) Experience

RETIRED C

URRICULU

M

Page 86: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 2

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 87: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 3

SLIDE: 3-1-1 I. BASIC HYDRAULICS

A. Terms and symbols SLIDE: 3-1-2

1. Pi a) Symbol = π

Where does π come from?

b) The constant derived from the length of the circumference of a circle (3.14 times the diameter length); used as part of the formula to determine the volume of a round area

2. Appliance loss a) Symbol = AL b) Portion of pressure lost when water flows

through an appliance 1) Friction loss

3. Area a) Symbol = A b) Surface measurement c) Noted as a squared linear measurement

1) Such as square inches SLIDE: 3-1-3

4. Atmospheric pressure a) Weight of the air or atmosphere b) 14.7 psi at sea level c) Pressure gauge that reads zero is actually

14.7 psi What is cavitation?

5. Cavitation a) The formation of a vacuum around a propeller

or fan, revolving at a speed above a certain critical value

RETIRED C

URRICULU

M

Page 88: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 4

b) Vacuum pockets form in a pump and cause vibrations, loss of efficiency

6. Circumference a) Symbol = c b) The distance around the outside of a circle c) If the circumference were stretched out in a

straight line, it would be 3.14 times as long as the diameter

7. Coefficient a) Symbol = C b) Assigned to a math equation

SLIDE: 3-1-4 8. Constant

a) A fixed value assigned to a mathematical equation

9. Critical velocity a) The friction loss becomes so great that the

entire stream is agitated by the resistance and causes turbulence

b) At this point, it becomes necessary to parallel lines to reduce the friction

10. Diameter a) Symbol = d b) The distance from one edge of a circle to the

other passing through the center SLIDE: 3-1-5

11. Elevation pressure a) Symbol = EP

What is EP? b) Gain or loss of pressure in a hoseline due to

change in elevation c) The pressure lost from overcoming the effects

of forcing water above the level of the pump discharge

RETIRED C

URRICULU

M

Page 89: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 5

12. Feet per second a) Symbol = fps

13. Flow pressure a) Symbol = FP b) Forward velocity pressure measured at a

discharge opening c) Can be measured with a pitot tube and gauge

14. Friction loss a) Symbol = FL

What is friction loss? b) That part of the total pressure lost while forcing

water through pipe, fittings, hoselines, adapters, and appliances

c) Varies with the type of construction and shape of pipe, fittings, hoselines, adapters, and appliances

SLIDE: 3-1-6 15. Gallons per minute

a) Symbol = gpm b) The measure of water flow c) Volume per time measurement

16. Gravity a) Symbol = G

17. Head pressure a) Water pressure due to elevation b) Measured from the surface of the water source

to the discharge orifice c) 0.434 psi per foot of elevation

18. Height a) Symbol = h b) Measurement of elevation above a given point

RETIRED C

URRICULU

M

Page 90: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 6

SLIDE: 3-1-7 19. Hydraulics

What is hydraulics? a) The science that treats the mechanics of fluid

at rest and in motion 20. Inches in mercury

a) Symbol = in. Hg 21. Length

a) Symbol = L 22. Length of line

a) Symbol = LL SLIDE: 3-1-8

23. Lift Who can explain what lift is?

a) Elevation difference between the surface of the static water source and the eye of the pump impeller

b) Distance from the surface of the water to the center of the pump

24. Net pump discharge pressure a) Symbol = NPDP b) Actual amount of pressure being produced by

the pump SLIDE: 3-1-9

25. Normal operating pressure a) Pressure normally found in a water distribution

system during normal consumption demands 26. Nozzle pressure

a) Symbol = NP What is nozzle pressure?

b) Pressure of the water discharged at the nozzle

RETIRED C

URRICULU

M

Page 91: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 7

27. Nozzle reaction a) Symbol = NR b) Counterforce directed against a person holding

a nozzle SLIDE: 3-1-10

28. Pounds per square inch a) Symbol = psi

29. Pounds per square inch gauge a) Symbol = psig

30. Pressure a) Symbol = P b) Has a variety of meanings c) Generally defined as the force per unit area d) Measured in pounds per square inch (psi)

31. Pump discharge pressure a) Symbol = PDP b) Pressure of the water as it leaves the pump

32. Quantity of water a) Symbol = Q

SLIDE: 3-1-11 33. Radius

a) Symbol = r b) The distance from the outer edge of the circle

to the center of the circle 34. Residual pressure

What is residual pressure?

a) Remaining water pressure while water is flowing (left over)

b) Available pressure c) Measured at compound gauge with water

flowing

RETIRED C

URRICULU

M

Page 92: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 8

35. Specific gravity a) Symbol = sg b) The weight of a substance compared with the

weight of an equal volume of water SLIDE: 3-1-12

36. Square root a) Symbol = √ b) A given number multiplied by itself

37. Static pressure a) Water pressure that is not flowing (standing

still) b) Stored potential energy to force water through

pipe, hoselines, and fittings 38. Suction (draft)

Who can explain what suction or "draft" is?

a) Process of taking water from static sources located below the level of the eye of the pump

b) By exhausting the air from the pump chamber and using atmospheric pressure to force water through the suction hose and into the pump

SLIDE: 3-1-13 39. Total pressure loss

a) Symbol = TPL b) The amount of pressure loss due to total

friction loss and elevation pressure loss 40. Vacuum

How does a vacuum work to establish a draft?

a) Any pressure below atmospheric pressure b) A negative pressure

1) Usually indicated in inches of mercury

RETIRED C

URRICULU

M

Page 93: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 9

SLIDE: 3-1-14 41. Velocity

a) The speed of travel b) Linear measurement per time measurement

1) Feet per second (fps) or miles per hour (mph)

42. Volume a) Symbol = V b) Measurement of cubic scale in a container c) Noted as a cubed linear measurement

1) Cubic inches 43. Water flow

a) Measure in gallons per minute (gpm) 44. Water hammer

What is a water hammer? a) Force created by the sudden deceleration or

acceleration of water

RETIRED C

URRICULU

M

Page 94: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-1: Basic Hydraulic Terminology And Symbols Page 10

SUMMARY: Fire apparatus driver/operators are charged with the responsibility to develop effective hose streams, pump supply lines, and solve hydraulic problems on the fireground. All driver/operators must know and understand basic hydraulic terminology and symbols in order to apply them to hydraulic formulas. Although complex calculations are not performed in the field, driver/operators must know how to solve and apply them to provide a basis for developing hose streams. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read the Fire Apparatus Driver/Operator Student Supplement, SFT, 2008 Edition, Pages 18-21 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 571-587 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 95: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-2: Mathematics Review Page 1

TOPIC: 3-2: Mathematics Review

TIME FRAME: 1:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1(A), 5.2.2(A), and 5.2.4(A)

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of basic mathematics by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 22-24

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Individual Activity 3-2-1: Mathematics Review

REFERENCES: • Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 22-24

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIR

ED CURRIC

ULUM

Page 96: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-2: Mathematics Review Page 2

NOTE: Review the students' math pretest administered in Topic 1-1 to check their knowledge of basic math. Adjust the following review accordingly.

SLIDE: 3-2-1 SLIDE: 3-2-2

I. BASIC MATH SKILLS A. Addition B. Subtraction C. Multiplication D. Division

SLIDE: 3-2-3 E. Decimals

1. One number to the right of the decimal a) Tenths

2. Two numbers to the right of the decimal a) Hundreds

3. Three numbers to the right of the decimal a) Thousands

4. Rounding Who can explain what rounding is?

a) Truncate decimals two places to the right b) Make all calculations using this number c) When calculation is completed

1) Round .50 or higher - round up to a whole number

2) .49 or lower - round down to a whole number

SLIDE: 3-2-4 F. Fractions

1. When adding or subtracting a) Use common denominator

RETIRED C

URRICULU

M

Page 97: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-2: Mathematics Review Page 3

2. When multiplying a) Multiply numerators first b) Multiply denominators second

3. When dividing a) Invert second fraction b) Then multiply

SLIDE: 3-2-5 G. Percentages

1. Percent means a given value per 100 a) 45 of 100 = 45%

2. Multiply the number by the percentage SLIDE: 3-2-6

H. Square root 1. A quantity of which a given quantity is the square

a) √ 64 = 8 What is the square root of 81?

b) √ 81 = 9 SLIDE: 3-2-7

I. Numbers squared 1. A number multiplied by itself

a) 82 1) 8 x 8 = 64

What is 9 squared? b) 92

1) 9 x 9 = 81 SLIDE: 3-2-8

J. Fraction to decimal 1. Divide top number by bottom number

a) ½ = 0.5

RETIRED C

URRICULU

M

Page 98: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-2: Mathematics Review Page 4

What is ¾ in decimal form?

b) ¾ = 0.75 SLIDE: 3-2-9

K. Area of a circle

1. A = πr2

a) π = 3.14 b) r = radius (half of diameter) c) A = 3.14 x r2

If "r" is 2 feet, what is the area?

2. A = 3.14 x 22 a) A = 3.14 x 4 b) A = 12.56

SLIDE: 3-2-10 L. Capacity of a cylinder tank

1. Gallons = d26L a) d = diameter b) 6 = constant for gallons formula c) L = length

If a cylinder tank is 10 feet long and 5 feet in diameter, what is its capacity? SLIDE: 3-2-11

2. Gallons = (52 x 6)(10) a) Gallons = (25 x 6)(10) b) Gallons = (150)(10) c) Gallons = 1,500

SLIDE: 3-2-12

RETIRED C

URRICULU

M

Page 99: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-2: Mathematics Review Page 5

If a cylinder tank is 30 feet long and 10 feet in diameter, what is its capacity?

3. Gallons = (102 x 6)(30) a) Gallons = (100 x 6)(30) b) Gallons = (600)(30) c) Gallons = 18,000

ACTIVITY 3-2-1: Complete the activity in the student supplement.

RETIRED C

URRICULU

M

Page 100: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-2: Mathematics Review Page 6

SUMMARY: The basic math skills used by the driver/operator are vital to an effective operation. The ability for the driver/operator to understand the limitations of their apparatus equipment can be enhanced with a working knowledge of basic math. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 22-24 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 101: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-2: Mathematics Review Page 7

INDIVIDUAL ACTIVITY 3-2-1

TITLE: Mathematics Review

TIME FRAME: 0:15

MATERIALS NEEDED: • Square root chart • Calculator • Pen or pencil

INTRODUCTION: This activity provides the students the opportunity to reference and sharpen their math skills as they relate to fire hydraulics.

DIRECTIONS: 1. Complete Sections I through V. 2. You have 10 minutes to complete this activity. 3. Be prepared to discuss your answers with the class.

SECTION I: CALCULATE THE FOLLOWING SQUARE ROOTS

1. √ 8 2.82 See chart 2. √ 20 4.47 See chart 3. √ 100 10 See chart 4. √ 300 17.32 See chart

SECTION II: SQUARE THE FOLLOWING NUMBERS

5. 62 36 6 x 6 6. 92 81 9 x 9 7. 182 324 18 x 18 8. 1012 10201 101 x 101

RETIRED C

URRICULU

M

Page 102: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-2: Mathematics Review Page 8

SECTION III: CONVERT THE FOLLOWING FRACTIONS TO A DECIMAL

9. 7/8 .87 7 ÷ 8

10. 1/8 .12 1 ÷ 8

11. 1/4 .25 1 ÷ 4

12. 1/2 .50 1 ÷ 2

SECTION IV: CALCULATE THE AREA OF EACH CIRCLE Round your answer to the nearest whole number. (πr2)

13. Radius = 2 feet 13 3.14 x 22

3.14 x 4

14. Radius = 10 feet 314 3.14 x 102

3.14 x 25

15. Radius = 15 feet 706.5 3.14 x 152

3.14 x 56.25

16. Radius = 20 feet 1256 3.14 x 202

3.14 x 196

SECTION V: CALCULATE THE CAPACITY OF EACH CYLINDER TANK Round your answer to the nearest whole number. (d26L)

17. Diameter = 2 feet Length = 14 feet 336

(22 x 6)(14) (4 x 6)(14) 24 x 14

18. Diameter = 10 feet Length = 10 feet 6,000

(102 x 6)(10) (100 x 6)(10) 600 x 10

19. Diameter = 15 feet Length = 3 feet 4,050

(152 x 6)(3) (225 x 6)(3) 1,350 x 3

20. Diameter = 20 feet Length = 5 feet 12,000

(202 x 6)(5) (400 x 6)(5) 2,400 x 5

RETIRED C

URRICULU

M

Page 103: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-2: Mathematics Review Page 9

Square Roots of Numbers 1-250

n n n n n 1 1.000 51 7.1414 101 10.0499 151 12.2882 201 14.1774 2 1.414 52 7.2111 102 10.0995 152 12.3288 202 14.2127 3 1.732 53 7.2801 103 10.1489 153 12.3693 203 14.2478 4 2.000 54 7.3485 104 10.1980 154 12.4097 204 14.2829 5 2.236 55 7.4163 105 10.2470 155 12.4499 205 14.3178 6 2.449 56 7.4833 106 10.2956 156 12.4900 206 14.3527 7 2.646 57 7.5498 107 10.3441 157 12.5300 207 14.3875 8 2.828 58 7.6158 108 10.3923 158 12.5698 208 14.4222 9 3.000 59 7.6811 109 10.4403 159 12.6095 209 14.4568 10 3.162 60 7.7460 110 10.4881 160 12.6491 210 14.4914 11 3.3166 61 7.8102 111 10.5357 161 12.6886 211 14.5258 12 3.4641 62 7.8740 112 10.5830 162 12.7279 212 14.5602 13 3.6056 63 7.9373 113 10.6301 163 12.7671 213 14.5945 14 3.7417 64 8.0000 114 10.6771 164 12.8062 214 14.6287 15 3.8730 65 8.0623 115 10.7238 165 12.8452 215 14.6629 16 4.0000 66 8.1240 116 10.7703 166 12.8841 216 14.6969 17 4.1231 67 8.1854 117 10.8167 167 12.9228 217 14.7309 18 4.2426 68 8.2462 118 10.8628 168 12.9615 218 14.7648 19 4.3589 69 8.3066 119 10.9087 169 13.0000 219 14.7986 20 4.4721 70 8.3666 120 10.9545 170 13.0384 220 14.8324 21 4.5826 71 8.4261 121 11.0000 171 13.0767 221 14.8661 22 4.6904 72 8.4853 122 11.0454 172 13.1149 222 14.8997 23 4.7958 73 8.5440 123 11.0905 173 13.1529 223 14.9332 24 4.8990 74 8.6023 124 11.1355 174 13.1909 224 14.9666 25 5.0000 75 8.6603 125 11.1803 175 13.2288 225 15.0000 26 5.0990 76 8.7178 126 11.2250 176 13.2665 226 15.0333 27 5.1962 77 8.7750 127 11.2694 177 13.3041 227 15.0665 28 5.2915 78 8.8318 128 11.3137 178 13.3417 228 15.0997 29 5.3852 79 8.8882 129 11.3578 179 13.3791 229 15.1327 30 5.4772 80 8.9443 130 11.4018 180 13.4164 230 15.1658 31 5.5678 81 9.0000 131 11.4455 181 13.4536 231 15.1987 32 5.6569 82 9.0554 132 11.4891 182 13.4907 232 15.2315 33 5.7446 83 9.1104 133 11.5326 183 13.5277 233 15.2643 34 5.8310 84 9.1652 134 11.5758 184 13.5647 234 15.2971 35 5.9161 85 9.2195 135 11.6190 185 13.6015 235 15.3297 36 6.0000 86 9.2736 136 11.6619 186 13.6382 236 15.3623 37 6.0828 87 9.3274 137 11.7047 187 13.6748 237 15.3948 38 6.1644 88 9.3808 138 11.7473 188 13.7113 238 15.4272 39 6.2450 89 9.4340 139 11.7898 189 13.7477 239 15.4596 40 6.3246 90 9.4868 140 11.8322 190 13.7840 240 15.4919 41 6.4031 91 9.5394 141 11.8743 191 13.8203 241 15.5242 42 6.4807 92 9.5917 142 11.9164 192 13.8564 242 15.5563 43 6.5574 93 9.6437 143 11.9583 193 13.8924 243 15.5885 44 6.6332 94 9.6954 144 12.0000 194 13.9284 244 15.6205 45 6.7082 95 9.7468 145 12.0416 195 13.9642 245 15.6525 46 6.7823 96 9.7980 146 12.0830 196 14.0000 246 15.6844 47 6.8557 97 9.8489 147 12.1244 197 14.0357 247 15.7162 48 6.9282 98 9.8995 148 12.1655 198 14.0712 248 15.7480 49 7.0000 99 9.9499 149 12.2066 199 14.1067 249 15.7797 50 7.0711 100 10.0000 150 12.2474 200 14.1421 250 15.8114

n n n n n

RETIRED C

URRICULU

M

Page 104: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-3: Characteristics Of Water And Principles Of Pressure Page 1

TOPIC: 3-3: Characteristics Of Water And Principles Of Pressure

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of the characteristics and principles of water and pressure by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 135-161

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 135-161

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 105: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-3: Characteristics Of Water And Principles Of Pressure Page 2

SLIDE: 3-3-1 I. CHARACTERISTICS OF WATER

A. Water can exist in three forms SLIDE: 3-3-2

1. Liquid a) Exists at temperatures between 32°F - 212°F

SLIDE: 3-3-3 2. Solid

At what temperature will water not be in the liquid form?

a) Freezing occurs at temperatures below 32°F and converts it to ice

SLIDE: 3-3-4 3. Gas

a) Converts to a vapor or steam at temperatures above 212°F

SLIDE: 3-3-5 B. Weight of water

How much does 1 gallon of fresh water weigh?

1. Fresh water weighs 8.33 pounds per gallon 2. Salt water weighs 8.6 pounds per gallon 3. 1 cubic foot of water weighs 62.5 lbs.

SLIDE: 3-3-6 C. Water expansion

1. When converted to steam, expands 1,700 times SLIDE: 3-3-7

D. Water hammer What is a water hammer?

1. Force created by the sudden deceleration or acceleration of water

RETIRED C

URRICULU

M

Page 106: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-3: Characteristics Of Water And Principles Of Pressure Page 3

2. Causes a) Sudden opening and closing of nozzles or

valves 3. Damaging effects to

a) Hoselines b) Water mains c) Hydrants d) Fire pumps and its related accessories

1) Piping 4. Life safety

a) Sudden, violent jerking of hoselines and possible rupturing creates extreme, unsafe conditions

5. Corrective measures a) All controls should be moved slowly

1) Nozzles 2) Hydrants 3) Valves 4) Hose clamps

II. HOW PRESSURES ACT ON FLUIDS SLIDE: 3-3-8

A. First principle 1. Fluid pressure is perpendicular to any surface on

which it acts SLIDE: 3-3-9

B. Second principle 1. Fluid pressure at a point in a fluid at rest is of the

same intensity in all directions a) Fluid pressure at a point, at rest, has no

direction

RETIRED C

URRICULU

M

Page 107: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-3: Characteristics Of Water And Principles Of Pressure Page 4

SLIDE: 3-3-10 C. Third principle

1. Pressure applied to a confined fluid from without is transmitted equally in all directions

SLIDE: 3-3-11 D. Fourth principle

1. The pressure of a liquid in an open vessel is proportional to its depth

2. Example a) 1 square inch (cross-sectional area) in a

vertical container 1) At 1 foot = .434 pounds 2) At 2 feet = .868 pounds 3) At 3 feet = 1.302 pounds

NOTE: Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 143, Figure 6.16.

SLIDE: 3-3-12 E. Fifth principle

1. The pressure of a liquid in an open vessel is proportional to the density of the liquid

2. Example a) Container with 1 inch of mercury and a

container with 13.55 inches of water will exert the same pressure at the bottom

SLIDE: 3-3-13 F. Sixth principle

1. The pressure of a liquid on the bottom of a vessel is independent of the shape of the vessel

Water that is 1 foot in depth will exert how much pressure?

a) Four containers with different shapes with 1 foot of water in each will all exert .434 psi at the bottom

RETIRED C

URRICULU

M

Page 108: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-3: Characteristics Of Water And Principles Of Pressure Page 5

SUMMARY: Efficiently using water resources are vital to incident effectiveness. The ability to relate water characteristics and principles of pressure to the operation will help ensure successful completion of assignments. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 135-161 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 109: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-4: Principle Features Of Water Systems Page 1

TOPIC: 3-4: Principle Features Of Water Systems

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1(A) and 5.2.2(A)

BEHAVIORAL OBJECTIVE:

Condition: A written test

Behavior: The student will confirm a knowledge of the principal features of water systems by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 151-161 and 325

MATERIALS NEEDED: • Writing board with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Engineer Training Program, Tiburon Fire District, 2001 Edition, Page 03-3

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 151-161 and 325

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 110: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-4: Principle Features Of Water Systems Page 2

SLIDE: 3-4-1 SLIDE: 3-4-2

I. WATER SUPPLY SOURCES A. Surface water

1. Lakes, rivers, ponds, etc. B. Ground water

1. Wells or water producing stream How does the water get from the source to the hydrant? SLIDE: 3-4-3

II. PUMPS AND PUMPING STATIONS A. Used when gravity system not available or reliable

1. May be used as adjunct to gravity system B. Generally highly efficient

1. Usually completely automated C. Pumping capacity

1. Varies from a few hundred gallons per minutes to millions of gallons per day

2. Diesel pumps permit greater capacity and fuel economy

What is the most economical type of distribution system? SLIDE: 3-4-4

III. GRAVITY SYSTEM A. Uses natural elevation

1. Most practical method of delivery 2. Most economical method of delivery 3. Least installation costs 4. Least maintenance costs

RETIRED C

URRICULU

M

Page 111: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-4: Principle Features Of Water Systems Page 3

B. Capacity limited by basin or reservoir 1. System may operate with or without pumps

SLIDE: 3-4-5 IV. COMBINATION SYSTEM

A. Combines gravity flow and pumps 1. Used in majority of communities 2. Gravity system can operate if pumps fail

What can be done to provide a better supply of water at a dead end?

3. Tanks used on dead ends B. Combined storage

1. Elevated reservoirs 2. If not in use, water tenders can be utilized

SLIDE: 3-4-6 V. DISTRIBUTION SYSTEMS

A. Elements 1. Pipes 2. Valves 3. Hydrants 4. Meters 5. Other appliances for conveying water

B. System design 1. Grid

a) Provides circulating feed from several mains b) Most common c) Interlooped and connected at standard

intervals 2. Looped line or circulation feed

a) A hydrant that receives water from two or more directions

RETIRED C

URRICULU

M

Page 112: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-4: Principle Features Of Water Systems Page 4

3. Dead-end a) A hydrant that receives water from only one

direction C. Grid system piping

1. Primary feeder (mains) a) Large pipes b) Wide spacing c) High capacity d) 8-52 inches or greater e) Carries water to points for local distribution

2. Secondary feeders a) Intermediate-sized pipes b) Forms loops closely spaced c) High capacity d) 8-36 inches or greater e) Carries water to distribution lines

3. Distributors a) Smaller internal grid arrangements that serve

consumer blocks and individual fire hydrants b) Close spacing c) High capacity d) Pipe size

1) Residential/multiple housing districts

• 6-inch minimum

• Should be closely gridded by 8-inch cross-connecting mains at intervals of not more than 600 feet

• May need larger size main depending on layout and occupancy

RETIRED C

URRICULU

M

Page 113: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-4: Principle Features Of Water Systems Page 5

2) Shopping/commercial districts • 8-inch minimum • With cross-connecting mains every

600 feet • May need larger size main depending

on layout and occupancy 3) 12-inch mains may be used in principal

streets and in long mains not cross-connected at frequent intervals

SLIDE: 3-4-7 VI. GENERAL INFORMATION

What is the purpose of main line valves in the distribution system?

A. Main valves 1. Used to provide flow control in the water system 2. Valves should be tested each year

What is the suggested spacing for valves in high value districts?

3. High value area spacing a) 500 feet

4. Other areas' spacing a) 800 feet

B. Water main pipe 1. Usually good for 30 years service

C. Hydrant color codes 1. Based on gallons per minute of flow 2. Normally painted on the discharge caps and tops 3. NFPA color codes

a) Light blue 1) Class AA

• 1,500 gpm or greater

RETIRED C

URRICULU

M

Page 114: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-4: Principle Features Of Water Systems Page 6

b) Green 1) Class A

• 1,000-1,499 gpm c) Orange

1) Class B

• 500-999 gpm d) Red

1) Class C

• 499 or less

RETIRED C

URRICULU

M

Page 115: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-4: Principle Features Of Water Systems Page 7

SUMMARY: It is important that you determine the main components and features of a modern water system. You should also determine the types of water distribution systems and what types of problems can be anticipated within the modern water system. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 151-161 and 325 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 116: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-5: Nozzle Theory Page 1

TOPIC: 3-5: Nozzle Theory

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1, 5.2.2(B), 5.2.4(B)

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of nozzle theory by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 165-179

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 165-179

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 117: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-5: Nozzle Theory Page 2

SLIDE: 3-5-1 SLIDE: 3-5-2

I. TYPES OF NOZZLES A. Handline nozzles

1. Range in size from ¾" booster line nozzles 2. To nozzles designed for 3" hoseline

What is the maximum flow for a handline?

3. Generally 350 gpm is maximum flow B. Master stream nozzles

1. Usually designed to flow 350 gpm or greater SLIDE: 3-5-3

II. HANDLINE NOZZLES A. Solid stream nozzles

1. Produced from smooth bore nozzle 2. Operates at 50 psi

B. Fog stream nozzles 1. Constant flow nozzles

a) Operate at 100 psi b) Low pressure nozzles operate at 75 psi

2. Manually adjustable nozzles a) Operate at 100 psi b) Low pressure nozzles operate at 75 psi

3. Automatic nozzles What pressure is maintained by an automatic nozzle?

a) Automatically regulate the opening to maintain 100 psi

b) Driver/operator can "dial" up the pressure and volume when water supply permits

c) Driver/operator controls gpm flow

RETIRED C

URRICULU

M

Page 118: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-5: Nozzle Theory Page 3

1) Nozzle person does not d) Low pressure nozzles operate at 75 psi

4. High pressure fog nozzles a) Operate at pressure up to 800 psi b) Low volume flow is 8-15 gpm

C. Broken stream nozzles What is an example of a broken stream nozzle?

1. Special purpose nozzles 2. Cellar and pier nozzles

a) Distributors 3. Water curtain nozzles 4. Piercing nozzles

a) Deliver about 100 gpm 5. Chimney nozzles

a) Operate at 100 psi b) Deliver only 1½-3 gpm

SLIDE: 3-5-4 III. MASTER STREAMS

A. Smooth bore operates at 80 psi B. Fog operates at 100 psi C. Four basic categories

1. Monitor a) Three basic types

1) Fixed • Permanently mounted on apparatus

2) Combination

• Mounted on apparatus • Can be used as a turret

• Removed and used as a portable monitor

RETIRED C

URRICULU

M

Page 119: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-5: Nozzle Theory Page 4

3) Portable • Carried to location where needed

2. Turret pipe a) Also known as deck gun or deck pipe

3. Deluge set a) Large capacity nozzle on a playpipe supported

by a tripod and connected by a short length of large diameter hose

4. Elevated master stream a) Large capacity nozzle that is designed to be

placed on an aerial apparatus elevating device SLIDE: 3-5-5 What is nozzle reaction?

IV. NOZZLE REACTION A. Force pushing back on the fire fighter handling the

hoseline 1. Counterforce

B. For every action there is an equal and opposite reaction

C. Calculation 1. Solid tip nozzle

a) NR = (1.57 x d2)(NP) 2. Fog nozzle

a) NR = (0.0505 x Q)(√NP) b) NR = Q/2 or NR = ½ gpm

RETIRED C

URRICULU

M

Page 120: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-5: Nozzle Theory Page 5

SUMMARY: The driver/operator is responsible for safely operating the apparatus and all its appliances. Having the knowledge of nozzle types and nozzle reaction will help ensure a safe efficient operation. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 165-179 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 121: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 1

TOPIC: 3-6: Calculating Gallons Per Minute

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and written test

Behavior: The student will confirm a knowledge of calculating gpm by completing the activity and written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator Student Supplement, SFT, 2008 Edition, Pages 28-30 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 166 and 179

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Individual Activity 3-6-1: Calculating gpm

REFERENCES: • Driver Operator Training Program, Modesto Regional Training Center, 2002 Edition, Calculating GPM Section

• Engineer Training Program, Tiburon Fire District, 2001 Edition, Pages 28-1, 28-2, 28A-1, 28A-2

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 166 and 179

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the

RETIRED C

URRICULU

M

Page 122: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 2

heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 123: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-6: Calculating Gallons Per Minute Page 3

SLIDE: 3-6-1 I. NOZZLE GPM

SLIDE: 3-6-2

A. gpm = (29.7)(d2 x √NP) 1. 29.7 = a constant 2. d2 = diameter of the nozzle orifice squared

3. √ = square root 4. NP = nozzle pressure

SLIDE: 3-6-3 If the nozzle diameter is 2" and the NP is 80 psi, what is the gpm?

5. Example

a) gpm = (29.7)(22 x √80) b) gpm = (29.7)(4 x 8.94) c) gpm = (29.7)(35.76) d) gpm = 1,062.072 e) gpm = 1062 (round off)

SLIDE: 3-6-4 II. HYDRANT GPM

A. Slightly different than the formula for nozzles 1. gpm formula for hydrants (open butts) adds a

coefficient step 2. Pressure is flow pressure (FP)

B. gpm = (29.7)[c x (d2 x √ FP)] 1. 29.7 = a constant 2. c = coefficient based on hydrant design 3. d2 = diameter of the discharge orifice squared

4. √ = square root 5. FP = flow pressure

RETIRED C

URRICULU

M

Page 124: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-6: Calculating Gallons Per Minute Page 4

SLIDE: 3-6-5 C. Coefficient is assigned as a on the friction loss

depending on the hydrant's construction type 1. .7, .8, or .9

a) .7 would denote the greatest FL b) .9 would denote the least FL c) A hydrant with no FL would have a coefficient

of 1 2. Usually affected by the hydrant's configuration 3. Multiplied into the equation

If the coefficient is .8, the diameter of the orifice is 2.5 inches, and the FP is 30 psi, what is the gpm? SLIDE: 3-6-6

D. Example

1. gpm = (29.7)[.8 x (2.52 x √ 30)] 2. gpm = (29.7)[.8 x (6.25 x 5.48)] 3. gpm = (29.7)(.8 x 34.25) 4. gpm = (29.7)(27.4) 5. gpm = 813.78

NOTE: For calculating FL, round off to the whole number (814).

ACTIVITY 3-6-1: Complete the activity in the student supplement.

RETIRED C

URRICULU

M

Page 125: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 5

SUMMARY: The knowledge of formulas for calculating gpm is a vital part of the driver/operator's responsibilities. This knowledge can be key in testing and incident situations. The more accurate the calculations are, the more effective and efficient the overall operations will be. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator Student Supplement, SFT, 2008 Edition, Pages 28-30 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 166 and 179 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 126: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 6

INDIVIDUAL ACTIVITY 3-6-1

TITLE: Calculating Nozzle and Hydrant gpm

TIME FRAME: 0:20

MATERIALS NEEDED: • Pen or pencil

INTRODUCTION: This activity provides the students the opportunity to calculate gpm for nozzles and hydrants in a step-by-step format using standard formulas.

DIRECTIONS: 1. Calculate the gpm for each of the following using the appropriate formula.

2. You have 15 minutes to complete this activity. 3. Be prepared to discuss your answers with the class.

NOZZLES

1. Nozzle = 1⅛" tip and NP of 60 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(1.1252x √ 60) gpm = (29.7)(1.27 x 7.75) gpm = (29.7)(9.84) gpm = 292

2. Nozzle = 1" tip and NP of 50 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(12 x √ 50) gpm = (29.7)(1 x 7.07) gpm = (29.7)(7.07) gpm = 210

RETIRED C

URRICULU

M

Page 127: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 7

3. Nozzle = 1¼" tip and NP of 50 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(1.252 x √ 50) gpm = (29.7)(1.56 x 7.07) gpm = (29.7)(11.03) gpm = 328

4. Nozzle = 1½" tip and NP of 80 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(1.52 x √ 80) gpm = (29.7)(2.25 x 8.94) gpm = (29.7)(20.12) gpm = 598

5. Nozzle = 1¾" tip and NP of 80 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(1.752 x √ 80) gpm = (29.7)(3.06 x 8.94) gpm = (29.7)(27.36) gpm = 813

6. Nozzle = ⅞" tip and NP of 50 psi

gpm = (29.7)(d2 x √ NP)

gpm = (29.7)(.8752 x √ 50) gpm = (29.7)(.77x 7.07) gpm = (29.7)(5.44) gpm = 162

RETIRED C

URRICULU

M

Page 128: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 8

HYDRANTS

7. Hydrant = .7 coefficient, 2½" outlet, and FP of 43 psi gpm = (29.7)[c x (d2 x √ FP)] gpm = (29.7)[.7 x (2.52 x √ 43)] gpm = (29.7)[.7 x (6.25 x 6.56)] gpm = (29.7)(.7 x 41) gpm = (29.7)(28.7) gpm = 852

8. Hydrant = .8 coefficient, 2½" outlet, and FP of 90 psi gpm = (29.7)[c x (d2 x √ FP)] gpm = (29.7)[.8 x (2.52 x √ 90)] gpm = (29.7)[.8 x (6.25 x 9.49)] gpm = (29.7)(.8 x 59.31) gpm = (29.7)(47.45) gpm = 1,409

9. Hydrant = .7 coefficient, 2½" outlet, and FP of 86 psi gpm = (29.7)[c x (d2 x √ FP)] gpm = (29.7)[.7 x (2.52 x √ 86)] gpm = (29.7)[.7 x (6.25 x 9.27)] gpm = (29.7)(.7 x 57.94) gpm = (29.7)(40.56) gpm = 1205

RETIRED C

URRICULU

M

Page 129: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-6: Calculating Gallons Per Minute Page 9

10. Hydrant = .9 coefficient, 2½" outlet, and FP of 75 psi gpm = (29.7)[c x (d2 x √ FP)] gpm = (29.7)[.9 x (2.52 x √ 75)] gpm = (29.7)[.9 x (6.25 x 8.66)] gpm = (29.7)(.9 x 54.13) gpm = (29.7)(48.72) gpm = 1,447

RETIRED C

URRICULU

M

Page 130: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-7: Principles Of Friction Loss Page 1

TOPIC: 3-7: Principles Of Friction Loss

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of factors affecting friction loss by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 147-150

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Engineer Training Program, Tiburon Fire District, 2000 Edition, Pages 30-1 and 30-2

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 147-150

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 131: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-7: Principles Of Friction Loss Page 2

SLIDE: 3-7-1 SLIDE: 3-7-2

I. FRICTION LOSS A. That part of total pressure that is used to overcome

friction while forcing water through pipes, fittings, fire hose and adapters

B. The difference in pressures in a hoseline between a nozzle and a pumper is a good example for friction loss

What causes friction loss? SLIDE: 3-7-3

II. CAUSES OF FRICTION LOSS A. Movement of water molecules against each other B. Fire hose type, lining, and age C. Crushed couplings D. Sharp bends E. Change in size of orifice by adapters

SLIDE: 3-7-4 III. FOUR BASIC PRINCIPLES OF FRICTION LOSS

A. All other conditions being the same, the loss by friction varies directly with the length of hoseline or pipe 1. A hoseline 100 feet long and a hoseline 200 feet

long, both flowing 200 gpm, have different friction loss because of their length

B. When the same size of hoseline is used, the friction loss will vary approximately with the square of the increase in the velocity of the flow 1. When the flow through a 3" hoseline doubles from

200 gpm to 400 gpm, the friction loss increases four times

2. When the flow is tripled from 200 gpm to 600 gpm, the friction loss increases nine times

RETIRED C

URRICULU

M

Page 132: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-7: Principles Of Friction Loss Page 3

C. For the same discharge, friction loss varies inversely as the fifth power of the diameter of the hose 1. This can be illustrated by comparing the friction

loss factor in a 3" hoseline and 4" hoseline 2. The 3" hoseline has four times the friction loss as

the 4" hoseline D. For a given velocity of flow, the friction loss in hoseline

is approximately the same, whatever the pressure on the water may be 1. A 1½" hoseline flowing 100 gpm and a PDP of 124,

friction loss is 24 psi 2. When the PDP is doubled to 248 but the flow

remains at 100 gpm, the friction loss does not change

What is critical velocity? SLIDE: 3-7-5

IV. CRITICAL VELOCITY A. When the velocity of a fire stream becomes so great

that the entire stream is agitated by resistance, causing turbulence

B. Increased friction loss How can FL be reduced? SLIDE: 3-7-6

V. TO REDUCE FRICTION LOSS A. Check for rough linings in old hose B. Replace crushed couplings C. Eliminate sharp bends D. Use adapters only when necessary E. Keep nozzles and valves fully open when possible F. Use gaskets of proper size G. Use shorter hose lays when at all possible H. When flow must be increased, use larger hoselines or

multiple lines

RETIRED C

URRICULU

M

Page 133: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-7: Principles Of Friction Loss Page 4

SUMMARY: Friction loss is one of the largest factors that must be overcome when pumping hoselines. A pump operator who knows how friction loss affects pump operations will be able to overcome friction loss problems and successfully develop effective hose streams. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 147-150 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 134: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 1

TOPIC: 3-8: Calculating Friction Loss In Hose Lays

TIME FRAME: 4:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1(A) and 5.2.2(A)

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and written test

Behavior: The student will confirm a knowledge of calculating friction lossin hose lays by completing the activity and written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 32-40 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 185-209

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Individual Activity 3-8-1: Calculating Friction Loss

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 185-209

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 135: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 2

SLIDE: 3-8-1 SLIDE: 3-8-2

I. FRICTION LOSS FORMULA A. FL = (C x Q2)(L) B. C = Coefficient for hose diameter C. Q = Quantity

1. Flow rate in hundreds of gallons per minute 2. gpm/100

D. L = Length 1. Number of 100-foot lengths of hoseline 2. L/100

II. FRICTION LOSS COEFFICIENTS What is a coefficient? SLIDE: 3-8-3

A. C factors refer to the third principle of friction loss 1. Are the base of the friction loss equation 2. Assigned based on the diameter of the hose

a) The larger the diameter of hose, the friction loss is greatly decreased

B. Reflects a worst-case scenario 1. Results are probably slightly higher than the actual

friction loss SLIDE: 3-8-4

C. Standard (coefficients) 1. 1" = 150 2. 1½" = 24 3. 1¾" = 10* 4. 2½" = 2 5. 3" = 0.8

* Friction loss coefficient determination from IFSTA used for 1¾" hoseline.

Tests resulted in a coefficient of 9.9. Recommended FL coefficient is 10.

RETIRED C

URRICULU

M

Page 136: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 3

6. 4" = 0.2 7. 4½" = 0.1 8. 5" = 0.08

SLIDE: 3-8-5 SLIDE: 3-8-6

III. CALCULATING "Q" A. Second step of friction loss formula B. Must be calculated, then applied to friction loss formula

If gpm is 200, what is Q? C. Q = 200 (gpm)/100

1. Q = 2 If gpm is 400, what is Q?

D. Q = 400 (gpm)/100 1. Q = 4

IV. CALCULATING FRICTION LOSS If gpm is 200 and 100-feet of 2½" hoseline is laid, what is the FL? SLIDE: 3-8-7

A. FL = (C x Q2)(L) 1. FL = (2 x 22)(1) 2. FL = (2 x 4)(1) 3. FL = (8)(1) 4. FL = 8 psi

V. SINGLE HOSELINE FRICTION LOSS A. Most commonly used hose lay B. Simplest friction loss calculation

What is the FL for a 300-foot 2½" hoseline if the gpm is 100? SLIDE: 3-8-8

RETIRED C

URRICULU

M

Page 137: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 4

C. Example 1. FL = (2 x 12)(3) 2. FL = (2 x 1)(3) 3. FL = 2 x 3 4. FL = 6 psi

SLIDE: 3-8-9 VI. MULTIPLE HOSELINES OF EQUAL SIZE AND LENGTH

A. Calculate FL for one hoseline only if other hoselines will have the same pressure and gpm

What is the friction loss of two 2½" hoselines with 400 feet of hose each and a 1" nozzle? SLIDE: 3-8-10

B. Example 1. Calculating Q

a) gpm = (29.7)(d2 x √ NP)

b) gpm = (29.7)(12 x √ 50)

c) gpm = (29.7)(1 x 7.0711) d) gpm = (29.7)(7.0711) e) gpm = 210 psi = 200 psi

1) Round off for when calculating Q f) Q = 200

100 g) Q = 2

SLIDE: 3-8-11 2. Calculating friction loss

a) FL = (C x Q2)(L) b) FL = (2 x 22)(4) c) FL = (2 x 4)(4) d) FL = (8)(4) e) FL = 32 psi

RETIRED C

URRICULU

M

Page 138: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 5

SLIDE: 3-8-12 VII. WYED HOSE LAY OF EQUAL LENGTHS

A. One hoseline supplies two other hoselines B. A wye appliance takes one hoseline in and splits two

hoselines out 1. Two 1½" or 1¾" attack lines wyed from a 2½"

supply is common C. Calculate FL for supply line and one wyed hoseline,

then add the two together D. Only one of the wyed hoselines needs to be considered

when computing total FL because they both carry equal amounts of water

What is the correct FL? 2½" line: 200-feet 1¾" wye line: 150-feet gpm = 150 each line SLIDE: 3-8-13

E. Example 1. Calculating Q for 2½" line

a) Q = 300 100

b) Q = 3 2. Calculating Q for 1¾" wyed hoseline

a) Q = 150 100

b) Q = 1.5 SLIDE: 3-8-14

3. Calculating friction loss for 1¾" wyed hoseline a) FL = (C x Q2)(L) b) FL = (10 x 1.52)(1.5) c) FL = (10 x 2.25)(1.5) d) FL = (22.5)(1.5) e) FL = 34 psi

RETIRED C

URRICULU

M

Page 139: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 6

4. Calculating friction loss for 2½" hoseline a) FL = (C x Q2)(L) b) FL = (2 x 32)(2) c) FL = (2 x 9)(2) d) FL = (8)(2) e) FL = 36 psi

5. Add FL together a) 34 psi

36 psi 70 psi

SLIDE: 3-8-15 VIII. SIAMESE HOSELINES OF EQUAL LENGTH

A. Two or more hoselines laid parallel to each other B. Divide gpm by the number of hoselines, then calculate

FL for one line C. For two siamese lines of equal size and length, take ½

of the gpm flow and figure the FL for one line D. Coefficients are used in calculating FL for multiple lines

What is the correct FL? Siamese lines: 1,000-feet of 3" 2½" line: 300-feet" @ 300 gpm SLIDE: 3-8-16

E. Example 1. Calculating Q for siamese lines

a) Divide gpm by 2 (number of hoselines) b) Q = 150

100 c) Q = 1.5

2. Calculating Q for 2½" line a) Q = 300

100 b) Q = 3

RETIRED C

URRICULU

M

Page 140: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 7

SLIDE: 3-8-17 3. Calculating friction loss for siamese lines

a) FL = (C x Q2)(L) b) FL = (.8 x 1.52)(10) c) FL = (.8 x 2.25)(10) d) FL = (1.8)(10) e) FL = 18 psi

4. Calculating friction loss for 2½" a) FL = (C x Q2)(L) b) FL = (2 x 32)(3) c) FL = (2 x 9)(3) d) FL = (18)(3) e) FL = 54 psi

SLIDE: 3-8-18 5. Add FL together

a) 54 psi 18 psi 72 psi

SLIDE: 3-8-19 IX. MULTIPLE HOSELINES OF UNEQUAL LENGTH

A. Calculate FL for each line B. Pump for highest pressure needed C. Gate-down discharge of lines needing less pressure

What is the correct FL? Line 1 = 300-feet of 2½" Line 2 = 500-feet of 2½" gpm = 250 each line SLIDE: 3-8-20

D. Example 1. Calculating Q

a) Q = 250 100

b) Q = 2.5

RETIRED C

URRICULU

M

Page 141: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 8

SLIDE: 3-8-21 2. Calculating friction loss for Line 1

a) FL = (C x Q2)(L) b) FL = (2 x 2.52)(3) c) FL = (2 x 6.25)(3) d) FL = (12.5)(3) e) FL = 37.5 f) FL = 38 psi (round to whole number)

3. Calculating friction loss for Line 2 a) FL = (C x Q2)(L) b) FL = (2 x 2.52)(5) c) FL = (2 x 6.25)(5) d) FL = (12.5)(5) e) FL = 62.5 f) FL = 63 psi (round to whole number)

Which FL pressure would be used for PDP?

4. Use 63 psi for the most hydraulically demanding line

SLIDE: 3-8-22 X. WYED HOSE LAY OF UNEQUAL LENGTH

A. The addition of hose lengths to an existing wyed hoseline assembly may result in unequal length attack lines

B. Calculate FL for supply line and both wyed hoselines C. Pump to the highest wyed line and gate-down the other

wyed line What is the correct FL? 2½" line: 200-feet 1½" wye line: 150-feet 1½" wye line: 200-feet gpm = 100 each line

RETIRED C

URRICULU

M

Page 142: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 9

SLIDE: 3-8-23 D. Example

1. Calculating Q for 2½" line a) Q = 200

100 b) Q = 2

2. Calculating Q for wye line a) Q = 100

100 b) Q = 1

SLIDE: 3-8-24 3. Calculating friction loss for 2½" line

a) FL = (C x Q2)(L) b) FL = (2 x 22)(2) c) FL = (2 x 4)(2) d) FL = (8)(2) e) FL = 16 psi

4. Calculating friction loss for 150-foot wye line a) FL = (C x Q2)(L) b) FL = (24 x 12)(1.5) c) FL = (24 x 1)(1.5) d) FL = (24)(1.5) e) FL = 36 psi

5. Calculating friction loss for 200-foot wye line a) FL = (C x Q2)(L) b) FL = (24 x 12)(2) c) FL = (24 x 1)(2) d) FL = (24)(2) e) FL = 48 psi

RETIRED C

URRICULU

M

Page 143: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 10

SLIDE: 3-8-25 6. Add FL together

a) 48 psi 16 psi 64 psi

SLIDE: 3-8-26 XI. SIAMESE HOSELINES OF UNEQUAL LENGTH

A. Add the lengths of each line together, then divide by the number of lines

What is the correct FL? 3" siamese line: 900-feet 3" siamese line: 1,000-feet 2½" line: 100-feet @ 250 gpm

SLIDE: 3-8-27 B. Example

1. Calculating Q for siamese lines a) Divide gpm by 2 (number of hoselines) b) Q = 125

100 c) Q = 1.25

2. Calculating Q for 2½" line a) Q = 250

100 b) Q = 2.5

SLIDE: 3-8-28 3. Calculate L for siamese lines

a) Add the lengths of each line 1) 900

1,000 1,900

b) Divide by 2 (number of siamese lines) 2) 1,900 ÷ 2 = 950

RETIRED C

URRICULU

M

Page 144: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 11

c) Divide total length by 100 3) 950 ÷ 100 = 9.5 4) L = 9.5

4. Calculating friction loss for siamese lines a) FL = (C x Q2)(L) b) FL = (.8 x 1.252)(9.5) c) FL = (.8 x 1.56)(9.5) d) FL = (1.25)(9.5) e) FL = 12 psi

SLIDE: 3-8-29 5. Calculating friction loss for 2½" line

a) FL = (C x Q2)(L) b) FL = (2 x 2.52)(1) c) FL = (2 x 6.25)(1) d) FL = (12.5)(1) e) FL = 13 psi

6. Add FL together a) 13 psi

12 psi 25 psi

RETIRED C

URRICULU

M

Page 145: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 12

FRICTION LOSS COEFFICIENT DETERMINATION CHART

Date: 11/06/2002

Hose Size: 1¾"

Hose Construction: Double jacket, rubber lined

Person(s) Conducting The Tests: R. Confer, G. Bryant, T. Hostetter, D. Ockey

Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 Column 8 Column 9

Test Run #

Pump Discharge Pressure

psi

Pressure @ Gauge

1 psi

Pressure @ Gauge

2 psi

Nozzle Pressure*

psi

Flow from Flow

meter or by

Equation**

1 40 30 15 8 n/a

7.5 6.29

2 180 150 50 30 n/a

50 11.90

3 115 100 35 20 n/a

32.5 11.52

4

Total of all Column 9 answers

29.71 Average C = # of tests

conducted

*Not necessary if flow meter is used

**gpm = 29.7 d2 √NP

Average C =

9.90

RETIRED C

URRICULU

M

Page 146: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 13

SUMMARY: The theories involved in calculating friction loss are vital to the overall success of a pumping operation. The driver/operator must be able to correctly apply the proper friction loss formulas and coefficients to the related hose lays to produce an effective fire stream. Fire stream production and proper hose lays are the responsibility of the driver/operator. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 32-40 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 185-209 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 147: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 14

INDIVIDUAL ACTIVITY 3-8-1

Title: Calculating Friction Loss

TIME FRAME: 0:50

MATERIALS NEEDED: • Calculator • Pen or pencil

introduction: This activity provides the students the opportunity to strengthen their use of the friction loss formulas and sharpen their math skills.

DIRECTIONS: 1. Calculate the friction loss for each of the following. 2. Convert all letter values to number values first. 3. You have 30 minutes to complete this activity. 4. Be prepared to discuss your answers with the class.

RETIRED C

URRICULU

M

Page 148: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 15

SECTION I: SIMPLE HOSE LAYS

1. Find the correct friction loss.

FL = (C x Q2)(L) C = 2

Q = 2 (200/100)

L = 3 (300/100)

FL = (2 x 22)(3)

FL = 24 psi

200 gpm

300-feet of 2½"

RETIRED C

URRICULU

M

Page 149: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 16

2. Find the correct friction loss.

FL = (C x Q2)(L) C = 10

Q = 2 (200/100)

L = 2 (200/100)

FL = (10 x 22)(2)

FL = 80 psi

200-feet of 1¾" "

200 gpm

200-feet of 1¾"

200 gpm

RETIRED C

URRICULU

M

Page 150: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 17

3. Find the correct friction loss.

2½" Line: Wye Line:

FL = (C x Q2)(L) FL = (C x Q2)(L) C = 2 C = 10

Q = 3 (300/100) Q = 1.5 (150/100)

L = 1.5 (150/100) L = 1 (100/100)

FL = (2 x 32)(1.5) FL = (10 x 1.52)(1)

FL = 27 psi FL = 23 psi (22.5)

150-feet of 2½"

150 gpm

150 gpm

150-feet of 1¾"

150-feet of 1¾"

RETIRED C

URRICULU

M

Page 151: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 18

4. Find the correct friction loss.

Siamese Lines: 2½" Line:

FL = (C x Q2)(L) FL = (C x Q2)(L) C = .8 C = 2

Q = 1.25 (125/100) Q = 2.5 (250/100)

L = 9 (900/100) L = 1 (100/100)

FL = (.8 x 1.252)(9) FL = (2 x 2.52)(1)

FL = 11 psi (11.25) FL = 13 psi (12.5)

TOTAL FL = 24 psi (11 psi + 13 psi)

900-feet of 3"

250 gpm 900-feet of 3"

100-feet of 2½"

RETIRED C

URRICULU

M

Page 152: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 19

SECTION II: COMPLEX HOSE LAYS

5. Find the correct friction loss.

Line 1: Line 2:

FL = (C x Q2)(L) FL = (C x Q2)(L) C = 2 C = 2

Q = 2.5 (250/100) Q = 2.5 (250/100)

L = 1.5 (150/100) L = 2.5 (250/100)

FL = (2 x 2.52)(1.5) FL = (2 x 2.52)(2.5)

FL = 19 psi (18.75) FL = 31 psi (31.25)

250 gpm Line 1: 150-feet of 2½"

250 gpm

Line 2: 250-feet of 2½"

RETIRED C

URRICULU

M

Page 153: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 20

6. Find the correct friction loss.

2½" Line: 150' Wye Line:

FL = (C x Q2)(L) FL = (C x Q2)(L) C = 2 C = 10

Q = 2.5 (250/100) Q = 1.25 (125/100)

L = 3 (300/100) L = 1.5 (150/100)

FL = (2 x 2.52)(3) FL = (10 x 1.252)(1.5)

FL = 38 psi FL = 24 psi (23.4)

200' Wye Line:

FL = (C x Q2)(L) C = 10

Q = 1.25 (125/100)

L = 2 (200/100)

FL = (10 x 1.252)(2)

FL = 31 psi (31.2)

150-feet of 1¾"

300-feet of 2½"

125 gpm

125 gpm

200-feet of 1¾"

RETIRED C

URRICULU

M

Page 154: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-8: Calculating Friction Loss In Hose Lays Page 21

7. Find the correct friction loss.

Total length of Line 1 and Line 2 = 1,900 feet

50% of total length = 950 feet (1,900/2)

Siamese Lines: 2½" Line:

FL = (C x Q2)(L) FL = (C x Q2)(L) C = .8 C = 2

Q = 1.25 (125/100) Q = 2.5 (250/100)

L = 9.5 (950/100) L = 1 (100/100)

FL = (.8 x 1.252)(9.5) FL = (2 x 2.52)(1)

FL = 12 psi (11.87) FL = 13 psi (12.5)

TOTAL FL = 25 psi (12 psi + 13 psi)

900-feet of 3"

250 gpm

1,000-feet of 3"

100-feet of 2½"

RETIRED C

URRICULU

M

Page 155: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 1

TOPIC: 3-9: Pump Discharge Pressure

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2.4(A)

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and written test

Behavior: The student will confirm a knowledge of pump discharge pressure (PDP) by completing the activity and written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 41-47 and Pumping Apparatus Driver/Operator Handbook, IFSTA, First Edition, Pages 209-213

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Activity 3-9-1: Calculating Pump Discharge Pressure

REFERENCES: • Engineer Training Program, Tiburon Fire District, 2000 Edition, Pages 33-4 through 33-12

• Pumping Apparatus Driver/Operator Handbook, IFSTA, First Edition, Pages 209-213

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 156: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-9: Pump Discharge Pressure Page 2

SLIDE: 3-9-1 SLIDE: 3-9-2

I. PUMP DISCHARGE PRESSURE (PDP) FORMULA A. Nozzle pressure plus friction loss, plus appliance

friction loss, plus or minus elevation pressure loss SLIDE: 3-9-3

B. PDP = Nozzle pressure plus total pressure loss 1. PDP = NP + TPL

C. NP = nozzle pressure D. TPL = Total pressure loss

1. FL = friction loss in hose 2. AL = appliance friction loss

3. EP = elevation pressure ( + ) SLIDE: 3-9-4

II. NOZZLE PRESSURE A. The water pressure desired at the nozzle B. 1½" and 1¾" hoselines

1. NP = SOPs 2. NP = 100 psi (rule of thumb) for fog nozzles 3. NP = 50 psi for smooth bore tips 4. NP = 55-75 psi for low pressure fog nozzles

SLIDE: 3-9-5 C. 2½" hoselines

1. Smooth bore tip a) ½" through 1¼" tips considered handline use at

50 psi b) Should not be larger than one-half the diameter

of the hoseline in order to be considered a handline

c) 2½" hoseline = 1¼" tip d) Maximum use as a handline

RETIRED C

URRICULU

M

Page 157: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-9: Pump Discharge Pressure Page 3

2. 1" smooth tip a) 50 psi @200 gpm

3. Fog nozzle a) 100 psi @ 250 gpm

4. Monitor a) 80 psi for smooth bore b) 100 psi for fog

SLIDE: 3-9-6 D. Master streams

1. Any fire stream too large to be controlled without mechanical aid and above 50 psi

SLIDE: 3-9-7 III. APPLIANCE FRICTION LOSS

A. Friction loss in fire fighting appliances due to increased turbulence of water in motion

B. Standard friction loss values added to the friction loss found in hoselines 1. Wye (>350 gpm) = 10 psi 2. Siamese (>350 gpm) = 10 psi 3. Portable monitor = 25 psi 4. Standpipe = 25 psi

SLIDE: 3-9-8 IV. ELEVATION PRESSURE

A. Gained or lost pressure due to elevation B. .434 psi per foot C. 5 psi per story minus ground floor

1. Average story = 10 feet D. Add 5 psi per 100-feet of hoseline uphill E. Subtract 5 psi per 100-feet of hoseline downhill

RETIRED C

URRICULU

M

Page 158: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-9: Pump Discharge Pressure Page 4

V. CALCULATING PDP

A. PDP = NP + FL + AL + EP If NP=50, FL=10, AL=10, and EP=5, what is the PDP? SLIDE: 3-9-9

1. PDP = 50 + [10 + (10 + 5)] 2. PDP = 50 + (10 + 15) 3. PDP = 50 + 25 4. PDP = 75 psi

RETIRED C

URRICULU

M

Page 159: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 5

SUMMARY: Accurately calculating PDP will help ensure a safe and efficient operation. The pump operator's knowledge of how PDP will aid in or adversely affect the overall operation of an incident is vital. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 41-47 and Pumping Apparatus Driver/Operator Handbook, IFSTA, First Edition, Pages 209-213 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 160: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 6

INDIVIDUAL ACTIVITY 3-9-1

Title: Calculating Pump Discharge Pressure

TIME FRAME: 0:20

MATERIALS NEEDED: • Calculator • Pen or pencil

introduction: This activity provides the students the opportunity to develop their skill to calculate PDP using the proper formula.

DIRECTIONS: 1. Complete all problems using the pump discharge pressure formula.

2. You have 15 minutes to complete this activity. 3. Be prepared to discuss your answers with the class.

RETIRED C

URRICULU

M

Page 161: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 7

1. Calculate the correct pump discharge pressure.

2½" Line: 1¾" Line:

PDP = NP + [FL + (AL +/- EP)] PDP = NP + [FL + (AL +/- EP)] NP = 100 (fog) NP = 100 (fog)

FL = 19 FL = 80

AL = 0 AL = 0

EP = 0 EP = 0

PDP = 119 psi PDP = 180 psi

Pump discharge pressure should be 180 psi. The less demanding line(s) are "gated" down to their required pressure.

200-feet of 1¾"

200 gpm

150-feet of 2½"

250 gpm

RETIRED C

URRICULU

M

Page 162: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 8

2. Calculate the correct pump discharge pressure.

Line 1: Line 2:

PDP = NP + [FL + (AL +/- EP)] PDP = NP + [FL + (AL +/- EP)] NP = 100 (fog) NP = 100 (fog)

FL = 27 FL = 31

AL = 0 AL = 0

EP = 0 EP = 0

PDP = 127 psi PDP = 131 psi

Pump discharge pressure should be 131 psi. The less demanding line(s) are "gated" down to their required pressure. In reality, the PDP would be 130 psi for both lines.

Line 2: 250-feet of 2½"

250 gpm

Line 1: 150-feet of 2½"

300 gpm

RETIRED C

URRICULU

M

Page 163: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 9

3. Calculate the correct pump discharge pressure.

2½" Line: Wye Line:

PDP = NP + [FL + (AL +/- EP)] PDP = NP + [FL + (AL +/- EP)] NP = 100 (fog) NP = 100

FL = 72 FL = 35 (19 +16)

AL = 0 AL = 0

EP = 0 EP = 0

PDP = 172 psi PDP = 135 psi Pump discharge pressure should be 172 psi. The less demanding line is "gated" down to the required pressure.

150-feet of 2½"

400-feet of 2½"

300 gpm

125 gpm 125 gpm 100-feet of 1¾"

100-feet of 1¾"

RETIRED C

URRICULU

M

Page 164: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 10

4. Calculate the correct pump discharge pressure.

2½" Line: Wye Line:

PDP = NP + [FL + (AL +/- EP)] PDP = NP + [FL + (AL +/- EP)] NP = 100 (fog) NP = 100

FL = 25 FL = 61 (38 + 23)

AL = 0 AL = 0

EP = 0 EP = 0

PDP = 125 psi PDP = 161 psi

Pump discharge pressure should be 161 psi. The less demanding line is "gated" down to the required pressure.

300-feet of 2½"

200-feet of 2½"

250 gpm

125 gpm

125 gpm

150-feet of 1¾"

150-feet of 1¾"

RETIRED C

URRICULU

M

Page 165: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 11

5. Calculate the correct pump discharge pressure.

PDP = NP + [FL + (AL +/- EP)]

NP = 100

FL = 50

AL = 0

EP = 0

PDP = 150 psi

250 gpm

400-feet of 2½"

RETIRED C

URRICULU

M

Page 166: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-9: Pump Discharge Pressure Page 12

6. Find the correct pump discharge pressure for the hoselines connected to a standpipe, with fire floor on the third floor, and using 100-feet of 2 ½" hoseline with a fog nozzle at 200 gpm.

PDP = NP + [FL + (AL +/- EP)] NP = 100 (fog)

FL = 11 (3 + 8)

AL = 25

EP = 10

PDP = 146 psi

200-feet of 2½" 100 gpm

100-feet of 2½" 100 gpm

Line 3: 100-feet of 2½"

200 gpm

RETIRED C

URRICULU

M

Page 167: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 1

TOPIC: 3-10: Fireground Hydraulic Calculations

TIME FRAME: 1:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1(A) and 5.2.2(A)

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and written test

Behavior: The student will confirm a knowledge of fireground hydraulic calculations by completing the activity and written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 48-56 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 251-261

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Activity 3-10-1: Fireground Hydraulics

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 251-261

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 168: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-10: Fireground Hydraulic Calculations Page 2

SLIDE: 3-10-1 SLIDE: 3-10-2

I. FIREGROUND HYDRAULICS A. Fire streams calculations on the fireground require a

method that is easily understood and applicable to mnemonic use

B. Memorizing a few common elements that contribute to hydraulic calculations is an effective means in determining the necessary fire stream calculations

C. Individual departments should develop fireground hydraulic charts for their application

SLIDE: 3-10-3 II. RULE OF THUMB CHARTS

A. Common nozzle pressures and flows for 2½" hoselines 1. 1" smooth bore tip nozzle

a) 50 psi b) 200 gpm

What is the standard pressure for fog nozzles?

2. Fog nozzles a) 100 psi b) 250 gpm

SLIDE: 3-10-4 3. Master stream nozzles

a) Smooth bore tip 1) 80 psi 2) 1¼" tip = 400 gpm 3) 1⅜" tip = 500 gpm 4) 1½" tip = 600 gpm 5) 1⅝" tip = 700 gpm

RETIRED C

URRICULU

M

Page 169: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-10: Fireground Hydraulic Calculations Page 3

6) 1¾" tip = 800 gpm 7) 2" tip = 1,000 gpm

b) Fog 1) 100 psi 2) Flows can vary by manufacturer

SLIDE: 3-10-5 B. Common friction losses in fire hoseline

1. 3" hoseline a) ⅞" tip

1) FL = 2 psi 2) gpm = 150

b) 1" tip 1) FL = 4 psi 2) gpm = 200

c) 1⅛" tip 1) FL = 6 psi 2) gpm = 250

d) 1¼" tip 1) FL = 8 psi 2) gpm = 300

e) FL = Q2 1) Flow less than 500

SLIDE: 3-10-6 2. 2½" hoseline

a) ⅞" tip 1) FL = 5 psi 2) gpm = 150

b) 1" tip 1) FL = 10 psi 2) gpm = 200

RETIRED C

URRICULU

M

Page 170: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-10: Fireground Hydraulic Calculations Page 4

c) 1⅛" tip 1) FL = 15 psi 2) gpm = 250

d) 1¼" tip 1) FL = 20 psi 2) gpm = 300

SLIDE: 3-10-7 C. Common friction losses in hoseline appliances

1. Wye = 10 psi 2. Siamese = 10 psi

What is the friction loss for a portable monitor?

3. Portable monitor = 25 psi 4. Standpipe = 25 psi

SLIDE: 3-10-8 D. Common pressure usages

1. Preconnect 1½" and 1¾" a) PDP = 135 psi

2. PDP a) Do not exceed 250 psi

3. Intake (residual pressure) a) Do not drop below 20 psi

SLIDE: 3-10-9 4. Use volume mode

a) Two or more 2½" or larger hoselines pumping 50% or more of pump capacity

5. Elevation a) PDP = 5 psi per story

1) Minus first story

RETIRED C

URRICULU

M

Page 171: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-10: Fireground Hydraulic Calculations Page 5

6. Supplying an engine a) 50 psi to start

What is the PDP and total gpm when pumping through 300 feet of 2½" hoseline with a 1" smooth bore tip? SLIDE: 3-10-10

III. RULE OF THUMB FOR 2½" HOSELINE A. Example

1. gpm = 200 2. PDP = NP + FL 3. PDP = 50 + (10 x 3) 4. PDP = 50 + 30 5. PDP = 80 psi

What is the PDP and total gpm when pumping through 400 feet of 3" hoseline with a fog nozzle? SLIDE: 3-10-11

IV. RULE OF THUMB FOR 3" HOSELINE A. Example

1. gpm = 200 2. PDP = NP + FL 3. PDP = 100 + (4 x 4) 4. PDP = 100 + 16 5. PDP = 116 psi RETIR

ED CURRIC

ULUM

Page 172: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 3-10: Fireground Hydraulic Calculations Page 6

What is the PDP and total gpm when pumping to 150 feet of wyed 1½" hoselines using fog nozzles through 100 feet of 2½ " hoseline? SLIDE: 3-10-12

V. RULE OF THUMB FOR WYED HOSELINES A. Example

1. gpm = 200 2. PDP = NP + FL + AL 3. PDP = 135 + (10 x 1) + 10 4. PDP = 135 + 20 + 10 5. PDP = 155 psi

What is the PDP and total gpm when pumping to a ⅞" smooth bore tip nozzle through 200 feet of 2½" hoseline up to a third floor? SLIDE: 3-10-13

VI. RULE OF THUMB FOR ELEVATION LOSS A. Example

1. gpm = 150 2. PDP = NP + FL +/- EL 3. PDP = 50 + (10 x 1) + 10 4. PDP = 50 + (10) + 10 5. PDP = 50 + 20 6. PDP = 70 psi

RETIRED C

URRICULU

M

Page 173: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 7

SUMMARY: The driver/operator should understand and be able to calculate friction loss on the fireground. The ability to use "rule of thumb" calculations during critical periods of the incident can save time and increase efficiency. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 48-56 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 251-261 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 174: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 8

INDIVIDUAL ACTIVITY 3-10-1

TITLE: Fireground Hydraulics

TIME FRAME: 0:30

MATERIALS NEEDED: • Rule of Thumb charts • Calculator • Pen or pencil

INTRODUCTION: This activity provides the students the opportunity to become familiar with and sharpen their skills on fireground hydraulics.

DIRECTIONS: 1. Using the Rule of Thumb charts, calculate the gpm and PDP for the following scenarios.

2. You have 0:15 minutes to complete this activity. 3. Be prepared to discuss your answers with the class.

RETIRED C

URRICULU

M

Page 175: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 9

Rule Of Thumb Charts

NOZZLE PRESSURE FIRE HOSELINE FRICTION LOSS

PER 100' OF HOSELINE Nozzle psi gpm 3" FL Tip Size gpm 2½" FL

Smooth Tip (1") 50 200 2 ⅞" 150 5

Fog Nozzles 100 200 4 1" 200 10

Portable Monitor Same as above 6 1⅛" 250 15

8 1¼" 300 20

Q2 Flow less than 500

APPLIANCE FRICTION LOSS MASTER STREAM FLOWS

(80 psi) Appliance psi Tip gpm

Wye 10 1¼" 400

Siamese 10 1⅜" 500

Portable Monitor 25 1½" 600

Standpipe 25 1⅝" 700

1¾" 800

2" 1,000

Preconnect 1½" and 1¾" ........PDP = 135 psi PDP ........................................Do Not Exceed 250 psi Intake (Residual Pressure) .....Do Not Drop Below 20 psi Use Volume Mode ..................2 or more 2½" or larger hoselines are used

pumping 50% or more than the pump capacity Elevation.................................PDP 5 psi per story minus first story Supplying an Engine...............50 psi to start

RETIRED C

URRICULU

M

Page 176: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 10

1. Find the correct gpm and PDP for the hose lay using the information in the Rule of Thumb chart.

gpm = 200

PDP = NP + FL PDP = 50 + (10 x 4)

PDP = 50 + 40

PDP = 90

1" tip

400-feet of 2½"

RETIRED C

URRICULU

M

Page 177: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 11

2. Find the correct gpm and PDP for the hose lay using the information in the Rule of Thumb chart.

gpm = 300

PDP = NP + FL PDP = 50 + (20 x 6)

PDP = 50 + 120

PDP = 170

1¼" tip

600-feet of 2½"

RETIRED C

URRICULU

M

Page 178: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 12

3. Find the correct gpm and PDP for the hose lay using the information in the Rule of Thumb chart.

gpm = 250

PDP = NP + FL PDP = 50 + (6 x 8)

PDP = 50 + 48

PDP = 98

1⅛" tip

800-feet of 3"

RETIRED C

URRICULU

M

Page 179: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 13

4. Find the correct gpm and PDP for the hose lay using the information in the Rule of Thumb chart.

gpm = 200

PDP = NP + FL PDP = 100 + (4 x 5)

PDP = 100 + 20

PDP = 120

Fog nozzle

500-feet of 3"

RETIRED C

URRICULU

M

Page 180: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 14

5. Find the correct PDP for the hose lay using the information in the Rule of Thumb chart.

PDP = NP + FL

135

100 gpm

150-feet of 1½"

100 gpm

150-feet of 1½"

RETIRED C

URRICULU

M

Page 181: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 15

6. Find the PDP for the hose lay using the information in the Rule of Thumb chart.

Wye line: 2½" Line:

PDP 135 gpm = 200

FL = 10 x 4

FL = 40

PDP = 175 Wye Line PDP + 2½" Line FL

400-feet of 2½"

100 gpm

100 gpm

150-feet of 1½"

RETIRED C

URRICULU

M

Page 182: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 3-10: Fireground Hydraulic Calculations Page 16

7. Find the correct gpm and PDP for the hose lay up to the fourth floor of a building using the information in the Rule of Thumb chart.

gpm = 200

PDP = NP + FL + EL PDP = 50 + (10 x 3) + 15

PDP = 50 + 30 + 15

PDP = 95

4th Floor 1" tip

300-feet of 2½"

RETIRED C

URRICULU

M

Page 183: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-1: Inspecting The Pump Drive Systems Page 1

TOPIC: 4-1: Inspecting The Pump Drive Systems

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of Inspecting pump drive system by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 280-285

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition, Chapter 5

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapter 6

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 280-285

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 184: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-1: Inspecting The Pump Drive Systems Page 2

SLIDE: 4-1-1 I. INSPECTING PUMP DRIVE SYSTEMS AND

COMPONENTS SLIDE: 4-1-2

A. Auxiliary engine-driven pumps 1. Daily inspections

a) Operate on a daily basis b) Check all fluid levels

1) Auxiliary engine oil 2) Auxiliary fuel tank level if equipped

c) Inspect drive belts SLIDE: 4-1-3

2. Weekly inspections a) Check pump gear box

1) For proper oil level 2) For traces of water 3) For leakage of fluids

SLIDE: 4-1-4 B. Power take-off (PTO)

1. Daily inspections a) Operate on a daily basis b) Inspect drive shafts and universal joints

1) For bent or damaged drive shafts 2) For missing or loose retainers 3) For leakage of fluids

SLIDE: 4-1-5 C. Front-mounted

1. Daily inspections a) Operate on a daily basis

RETIRED C

URRICULU

M

Page 185: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-1: Inspecting The Pump Drive Systems Page 3

b) Inspect universal joints 1) For missing or loose retainers 2) For damage to clutch or universal joints

SLIDE: 4-1-6 2. Weekly inspections

a) Check pump gear box 1) For proper oil level 2) For traces of water 3) For leakage of fluids

D. Midship transfer drive SLIDE: 4-1-7

1. Daily inspections a) Operate on a daily basis b) Inspect drive shafts and universal joints

1) For missing or loose retainers 2) For bent or damaged drive shafts

SLIDE: 4-1-8 2. Weekly inspections

a) Check pump gear box 1) For proper oil level 2) For traces of water 3) For leakage of fluids

SLIDE: 4-1-9 E. Rear-mounted

1. Daily inspections a) Operate on a daily basis b) Inspect drive shafts and universal joints

1) For missing or loose retainers 2) For bent or damaged drive shafts

RETIRED C

URRICULU

M

Page 186: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-1: Inspecting The Pump Drive Systems Page 4

SLIDE: 4-1-10 2. Weekly inspections

a) Check pump gear box or transfer case 1) For proper oil level 2) For traces of water 3) For leakage of fluids

SLIDE: 4-1-11 II. ADDITIONAL INSPECTION INFORMATION

A. In accordance with manufacturer's recommendations and specifications

B. Per department SOPs SLIDE: 4-1-12

III. OUT-OF-SERVICE CRITERIA A. NFPA 1911: Inspection, Maintenance, Testing, and

Retirement of In-Service Automotive Fire Apparatus, 2007 Edition recommendations 1. Pump will not engage 2. Pump shift indicators in cab and on operator's

panel do not function properly 3. Pressure control system is not operational 4. Pump transmission components have Class 3

leakage 5. Pump operator's panel throttle is not operational 6. Pump operator's engine speed advancement

interlock is not operational 7. A qualified technician shall conduct an out-of-

service evaluation of the systems or components and make a written report, including recommendations to the AHJ

RETIRED C

URRICULU

M

Page 187: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-1: Inspecting The Pump Drive Systems Page 5

SUMMARY: An integral part of the fire pump system is the pump drive system. Each system has certain characteristics that make it more or less adaptable to a particular fire department need. As a driver/operator, you have the responsibility to perform routine inspections of the pump drive system. Inspections will involve maintenance, troubleshooting the system and identify deficiencies to insure trouble free operation. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 280-285 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 188: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-2: Inspecting The Priming Pump Systems Page 1

TOPIC: 4-2: Inspecting The Priming Pump Systems

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of inspecting the pump priming systems by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 299-301

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition, Chapter 5

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapter 6

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 299-301

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 189: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-2: Inspecting The Priming Pump Systems Page 2

SLIDE: 4-2-1 How often is the priming pump inspected? SLIDE: 4-2-2

I. WEEKLY INSPECTIONS A. Operate the pump primer

1. With all pump valves closed B. Check level in oil/fluid reservoir

1. Proper type of oil/fluid 2. Ensure vent hole is cleaned and opened if

equipped 3. Ensure anti-siphon hole (line vent) is clean and

open C. Check for fluid leakage D. Security of mounting

1. Check for loose or missing fasteners SLIDE: 4-2-3

II. ADDITIONAL INSPECTION INFORMATION A. In accordance with manufacturer's recommendations

and specifications B. Per department SOPs

RETIRED C

URRICULU

M

Page 190: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-2: Inspecting The Priming Pump Systems Page 3

SUMMARY: The ability for fire apparatus to successfully draft water, it must have several key components. One critical component is the priming pump. The driver/operator's have the responsibility to perform routine inspection of the priming pump system. This will involve maintenance, troubleshooting the system, and identifying deficiencies in the system. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 299-301 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 191: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-3: Inspecting The Pump Pressure Control Systems Page 1

TOPIC: 4-3: Inspecting The Pump Pressure Control Systems

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of inspecting the pump control pressure systems by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 293-298

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition, Chapter 5

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapter 6

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 293-298

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 192: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-3: Inspecting The Pump Pressure Control Systems Page 2

SLIDE: 4-3-1 Why should you check the pressure control device? SLIDE: 4-3-2

I. PURPOSE A. Ensures systems are in a safe operating condition and

operating within the required pressures set by the manufacturer

SLIDE: 4-3-3 II. INSPECTION CHECKS

A. Operational check 1. In accordance with

a) Manufacturer's recommendations and specifications

b) Department SOPs c) IFSTA recommends a weekly schedule

SLIDE: 4-3-4 2. Procedure

a) Engage pump b) Open tank-to-pump valve slightly

1) To flow water c) Throttle up to 150 psi d) Set pressure control device e) Throttle up

1) Should not exceed 30 psi above the set level

SLIDE: 4-3-5 f) NFPA 1911: Inspection, Maintenance, Testing,

and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition 1) System opens within 3-10 seconds

RETIRED C

URRICULU

M

Page 193: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-3: Inspecting The Pump Pressure Control Systems Page 3

2) Discharge pressure shall not exceed 30 psi above the set pressure

SLIDE: 4-3-6 B. Visual check

1. Confirm all components have no obvious defects 2. Mountings secure 3. No broken or loose lines 4. Strainer in pilot valve control is clean

a) If equipped SLIDE: 4-3-7

III. OUT-OF-SERVICE CRITERIA A. NFPA 1911: Inspection, Maintenance, Testing, and

Retirement of In-Service Automotive Fire Apparatus, 2007 Edition 1. Pressure control system that is not operational

RETIRED C

URRICULU

M

Page 194: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-3: Inspecting The Pump Pressure Control Systems Page 4

SUMMARY: A critical component for safe fireground operations is the pressure control system. It is imperative that this system be inspected and maintained according to the manufacture's recommendations and department SOPs. As a driver/operator, your inspections will involve maintenance, troubleshooting and identifying deficiencies in the system. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54 and 293-298 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 195: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-4: Pump Service Testing Page 1

TOPIC: 4-4: Pump Service Testing

TIME FRAME: 0:45

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of pump service testing by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 486-505

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 2009 Edition, Chapter 5

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapter 18

• Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 486-505

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 196: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-4: Pump Service Testing Page 2

SLIDE: 4-4-1 SLIDE: 4-4-2 What are the three required preservice tests? SLIDE: 4-4-3

I. PRESERVICE TESTS A. Manufacturer's test

1. Hydrostatic test B. Pump certification tests

1. Pumping tests 2. Pumping engine overload test 3. Pressure control system test 4. Priming device test 5. Vacuum test 6. Water tank-to-pump flow test

C. Acceptance testing II. PUMP SERVICE TESTS

SLIDE: 4-4-4 A. Engine speed test

1. Done under no load conditions What is the purpose of an engine speed test?

2. Ensures that the pump engine is still running at the same governed speed that is was rated for when the apparatus was new

SLIDE: 4-4-5 B. Dry vacuum test

1. Checks the priming device, pump, and hard intake hose for air leaks a) Pump must be dry

RETIRED C

URRICULU

M

Page 197: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-4: Pump Service Testing Page 3

b) All intakes open and capped c) All discharges closed and caps removed

2. Usually performed at the beginning of a pump service test

SLIDE: 4-4-6 C. Pumping test

1. Annual test 2. Checks the overall condition of the pump and

engine a) Capacity test - 150 psi (net pump pressure)

1) Twenty minute test 2) Record reading for 20 minutes at 5 minute

intervals of 100% of its rated capacity 3) Transfer valve in VOLUME position

b) Second test - 200 psi 1) 10 minute test

During this test, what capacity should the pump deliver?

2) Pump should deliver 70% of its rated volume capacity

• According to NFPA 1911 some pumps can run in either VOLUME (parallel) or PRESSURE (series)

• Check data plate on pump panel c) Third test - 250 psi

1) Ten minute test 2) Pump should deliver 50% of its rated

volume capacity 3) Pump must be in PRESSURE (series) for

this test SLIDE: 4-4-7

RETIRED C

URRICULU

M

Page 198: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-4: Pump Service Testing Page 4

D. Pressure control devices 1. Ensures that they maintain a safe level of pressure

on the pump when valves are closed a) Three part sequence test

1) Test at 90, 150, and 250 psi b) Close valves slowly during test

1) Valves should close within 3-10 seconds During this test, the pressure should not rise more than how many psi?

c) Pressure should not rise more than 30 psi SLIDE: 4-4-8

E. Discharge pressure gauge operational test 1. Ensures that the gauges are providing accurate

discharge information a) Test at 150, 200, and 250 psi b) Discharges to be capped except the one being

tested c) Quick visual of master discharge gauge should

match each individual gauge 2. Any gauge off by more than 10% should be

recalibrated, repaired, or replaced SLIDE: 4-4-9

F. Flow meter operational test 1. Ensures that the flow meter is providing accurate

discharge information a) Not a simple test b) Not all discharges have to be tested at once c) Test at 150, 200, and 250 psi d) Use hoseline with a solid stream nozzle

RETIRED C

URRICULU

M

Page 199: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-4: Pump Service Testing Page 5

What is used to measure the flow?

e) A pitot tube is used to measure the flow 2. Any flow meter off by more than 10% should be

recalibrated, repaired, or replaced SLIDE: 4-4-10

G. Tank-to-pump flow test 1. Ensures that the piping between the water tank and

pump is sufficient to supply the minimum amount of water specified by NFPA 1901

This test flow how many gallons per minute?

a) 500 gpm capacity or greater 1) Test should flow at least 500 gpm

SLIDE: 4-4-11 III. DOCUMENTATION

A. All calculations, figures, and pumping problems determined during the test should be recorded so that they may be filed 1. Per department SOPs

SLIDE: 4-4-12 IV. POSSIBLE PROBLEMS DURING PUMP SERVICE

TESTING A. Transmission in wrong gear B. High gear lockup not functioning (automatic

transmission) C. Clutch slipping D. Engine overheating E. Muffler clogged F. Tachometer inaccurate G. Nozzle too large

RETIRED C

URRICULU

M

Page 200: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-4: Pump Service Testing Page 6

SLIDE: 4-4-13 H. Transfer valve in wrong position I. Intake screens clogged J. Pump impeller(s) are clogged K. Pitot tube is clogged L. Vacuum leaks M. Excessive wear on wear rings

SLIDE: 4-4-14 V. OUT-OF-SERVICE CRITERIA

A. NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition 1. If the pump test indicates a deficiency, a qualified

technician shall conduct an out-of-service evaluation and make a written report, including recommendations to the AHJ

RETIRED C

URRICULU

M

Page 201: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-4: Pump Service Testing Page 7

SUMMARY: As fire apparatus get older, it is important that fire departments do an annual pump service test and record the test data in order to determine the dependability of a fire pump. Test data can show potential problems that can be repaired before a major breakdown occurs. This can prevent costly repairs, reduce down time, or fireground tragedies. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 486-505 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 202: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 1

TOPIC: 4-5: Maintenance Of The Pump And Control Systems

TIME FRAME: 1:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of maintenance of the pump and control systems by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 61-64

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 61-64

• Fire Service Instructor's Manual, Waterous Pump Company, 1996 Edition, Form 1077

• NFPA 1911: Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus, 2007 Edition, Chapter 18

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 203: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 2

SLIDE: 4-5-1 I. AFTER EACH OPERATION

A. Usually operations of 1 hour or more in duration What maintenance should occur after each operation of the pump? SLIDE: 4-5-2

B. Transfer valve 1. If transfer valve has lubrication fitting, add grease

and switch back and forth between positions 2. Also known as a changeover valve

C. Priming pump 1. Operate primer

a) Tighten all pump caps b) Close all pump valves c) Pull the primer control while watching for a

below zero reading on the master intake gauge d) Verify that the master intake gauge readings

hold for approximately 5 minutes after primer control is released

D. Priming tank 1. Check lubricant level; add if necessary

SLIDE: 4-5-3 II. WEEKLY

A. Relief valve system or governor 1. Test at 150, 200, 250 psi

B. Transfer valve (if applicable) 1. Test two-stage pumps only 2. Manual transfer valves

a) With the apparatus engine turned off, turn the handwheel between the volume pressure positions a few times to verify that the valve operates freely

RETIRED C

URRICULU

M

Page 204: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 3

b) Set for pumping, with the transfer valve in the volume position

c) Leave the engine at idle speed d) Move the transfer valve to the pressure

position e) Verify that the discharge pressure gauge

readings have approximately doubled 3. Power transfer valves

a) With the apparatus engine turned off, follow the manufacturer's recommendations and specifications to verify that the valve operates freely

b) Set for pumping, with the transfer valve in the volume position 1) Note the discharge gauge readings

c) Leave the engine at idle speed d) Move the transfer valve to the pressure

position e) Verify that the master intake gauge readings

have approximately doubled C. All valves

1. Operational a) Discharge b) Suction c) Hose d) Drain e) Multi-drain

2. Lubricate with dry molly spray D. Remote valve controls

1. Clean and lubricate as necessary a) Do not use grease

E. Pump shift warning indicator lights 1. Check for operation

RETIRED C

URRICULU

M

Page 205: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 4

How do we test the pump shift warning light?

2. Move the in-cab pump shift control valve from the ROAD position to the PUMP position a) The shift warning light should light within a few

seconds indicating a complete shift F. Pump gear box

1. Check fluid level and add if needed a) In accordance with manufacturer's

recommendations and specifications G. Pump packing

1. Check leakage and adjust if necessary How many drops per minute should be coming out from the packing?

a) 8-10 drops per minute at 100-150 psi b) Adjust packing gland if necessary c) Slight leakage will lubricate and cool shaft d) Replace packing if leak cannot be stopped per

manufacturer's recommendations and specifications

H. Suction tube threads 1. Lubricate

a) Do not use excessive grease I. Intake strainer

1. Clean 2. Check for loss of zinc anode

J. Cap gaskets 1. Inspect and replace if cracked or hard

K. Clapper valve 1. Check and exercise if applicable 2. In accordance with manufacturer's

recommendations and specifications

RETIRED C

URRICULU

M

Page 206: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 5

SLIDE: 4-5-4 III. MONTHLY

A. Hydraulic clutch reservoir 1. Check fluid level and add if needed

B. Chain drive transmission 1. Check lubricant level and add if needed

C. Transfer valve 1. Shift back and forth between positions

D. Priming pump 1. Perform vacuum test

E. Pilot valves 1. Check operation and clean strainer

F. Intake screens 1. Check condition

SLIDE: 4-5-5 IV. ANNUALLY

A. Anodes 1. Check condition

How often should anodes be replaced?

2. Replace when over 75% of the zinc has been consumed

3. Performance will vary with water quality and pH B. Gear drive transmission

1. Change lubricant C. Chain drive transmission

1. Change lubricant 2. Clean lubricant pump

a) Sump strainer if provided

RETIRED C

URRICULU

M

Page 207: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 6

D. Impeller shaft bearing(s) 1. Add grease

E. Mechanical seal 1. Flush seal chamber

F. Service test 1. Perform service test according to NFPA 1911

standards G. Pump gear box

1. Drain and refill 2. Check magnetic plug 3. In accordance with manufacturer's

recommendations and specifications H. Drain lines

1. Drain and purge with air to ensure they are functioning properly and are not clogged with sediment or debris

I. Transfer valves 1. Lubricate

What kind of lubricant should be used on transfer valves?

a) Use white lithium grease or dry molly spray J. Pump packing

1. Recommend replacing every 2-3 years NOTE: Consult pump manufacturer's recommendations and

specifications and your department SOPs for maintenance.

RETIRED C

URRICULU

M

Page 208: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 4-5: Maintenance Of The Pump And Control Systems Page 7

SUMMARY: You have been shown the basics of pump maintenance. Make sure that you take the time to read and review the operator's manual for the apparatus you will be operating. In addition, adhere to your department's policies and manufacturers specifications. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 61-64 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 209: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-1: Making The Pump Operational (From Tank) Page 1

TOPIC: 5-1: Making The Pump Operational (From Tank)

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 4.2.1, 4.2.2, 5.1.1, 5.2.1, 5.2.2, 8.1.1, 8.2.1, 8.2.2, and 10.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of making the pump operational by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54, 288-290, and 315-323

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54, 288-290, and 315-323

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation. RETIRED C

URRICULU

M

Page 210: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 2

SLIDE: 5-1-1 I. PREPARATION

SLIDE: 5-1-2 A. Daily inspections prior to operation

1. Operate the pump drive control and make sure that the pump can be engaged a) Proper positioning and safety measures must

be in place prior to engaging the pump 2. Make sure the auxiliary fuel tank is full in the case

of separate engine-driven pumps a) For pumps with fuel supplies independent of

the main apparatus fuel tank 3. Make sure all gauges and valves on the pump

panel are in working order 4. Inspect the water and foam tanks for proper fluid

level SLIDE: 5-1-3

5. Check the underside of the apparatus and inside compartments for evidence of water or foam leaks

6. Test roof and bumper turrets for proper operation and full range of motion

7. If weather in your area is a factor, make sure that the fire pump and booster lines are completely drained of water a) To prevent damage from freezing

8. Once the pump is inspected, it should be operationally tested a) It is not necessary to test the pump at full

capacity SLIDE: 5-1-4

II. INITIAL PROCEDURES A. Once the apparatus is in position, the parking brake

must be set

RETIRED C

URRICULU

M

Page 211: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 3

1. IFSTA recommends that the apparatus wheels be chocked anytime the apparatus is parked

2. For an added measure of safety B. Most pumps are engaged before the driver leaves the

cab 1. Varies with the type of pump drive and

manufacturer SLIDE: 5-1-5

2. Most operations include a) Placing transmission in neutral b) Engaging the pump control lever c) Placing transmission into the appropriate gear

Where would the driver/operator find an indication that the pump is in the proper gear?

1) Proper gear may be indicated on or near the transmission controls

• May have a lock out device to keep it in the proper gear

2) Some pump controls automatically go into the proper gear by selecting drive

d) Confirm pump engagement 1) Increase in speedometer

• Should register 10-15 2) Pump indicator light 3) Audible change with engine

SLIDE: 5-1-6 C. Once the driver exits the cab and chocks the wheels,

the driver proceeds to the pump panel 1. Once the pump is operating, water must be moving

through the pump

RETIRED C

URRICULU

M

Page 212: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 4

2. Sources include a) Apparatus water tank b) Pressurized source c) Static source

What source is predominantly used during pump operations?

D. Initiating pump operations 1. Pump operations are almost always initiated from

the apparatus water supply a) Most incidents operate solely from the

apparatus water tank SLIDE: 5-1-7

2. The "Tank-to-Pump" valve must be opened to allow water to enter the pump a) Even if the pump is already full of water, a

constant source must be established 3. At this point, the pump should be turning and

building pressure Where can the driver/operator check to determine if water pressure is building within the pump?

a) Determined by a quick check of the master pump discharge gauge 1) If pump is operating properly, the gauge

will show a positive pressure reading 4. If the pump is a multi-stage pump, it must be

placed in the proper position before pressure builds SLIDE: 5-1-8

5. If hoselines are not ready to be charged, the "Tank Fill" valve can be partially opened to allow water to flow through the pump

RETIRED C

URRICULU

M

Page 213: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 5

a) This helps prevent the pump from over heating while not supplying hoselines

6. At this point, barring any problems, the pump is ready to start operations

7. The driver/operator must monitor all gauges while pumping a) The driver/operator must be ready to act

immediately to correct any problems that may occur

III. SETTING AUTOMATIC PRESSURE CONTROL DEVICES SLIDE: 5-1-9

A. Setting the pressure relief valve 1. Adjust the pump to the desired pressure 2. Turn handwheel counterclockwise until relief valve

opens a) Indicated by a sharp decrease in pressure b) An indicating light may also illuminate

3. Turn handwheel clockwise, slowly, until pump returns to desired pressure a) A properly set relief valve will be in the closed

position at the desired operating pressure b) NFPA 1901 requires the relief valve to open

within 3-10 seconds after the discharge pressure rises 30 psi above set pressure

4. Pressure relief valve may also include an on/off switch a) Normally these switches are used in case the

relief valve is stuck in the "Open" position and pump pressure cannot be increased

b) It is not recommended that pump operations be continued without a properly operating relief device

NOTE: There are a number of pressure relief valves available. Include a review of your department specific types.

RETIRED C

URRICULU

M

Page 214: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 6

SLIDE: 5-1-10 B. Setting the pressure governor

1. Some governors need to be set with water flowing and some do not a) Refer to manufacturer's recommendations and

specifications for department specific governors

2. Settings for most governors include a pressure selection device and an activation switch a) Refer to manufacturer's recommendations and

specifications 3. Set the pressure selection device once desired

pressure is determined 4. Engage the governor activation switch

a) Governor should now be set 5. Shutdown

a) Often is the reverse order NOTE: There are a number of pressure governors available.

Include a review of your department specific types. SLIDE: 5-1-11

IV. ON-GOING SAFETY PROCEDURES A. Water must be circulated through the pump while in

operation 1. If hoselines are used intermittently, the circulator

valve or "Tank Fill" valve must be opened to circulate water through the pump

2. If an external source is established, a waste line can be slightly opened so as not to overfill the water tank

SLIDE: 5-1-12 B. The driver/operator must be aware of the water tank

level when operating without an external supply 1. The driver/operator must be able to

a) Estimate the amount of water being used

RETIRED C

URRICULU

M

Page 215: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-1: Making The Pump Operational (From Tank) Page 7

b) Estimate the amount of time the remaining water will last

2. The driver/operator should warn the officer in charge as to the status of the water tank supply

SLIDE: 5-1-13 V. SHUTDOWN PROCEDURES

A. Slowly close unneeded lines 1. During partial shutdowns

a) Monitor the engine speed and other gauges 2. Ensure that water is moving through the pump if

lines are used intermittently B. Reduce throttle to idle C. Take transmission out-of-gear D. Disengage pump

1. Refill tank a) Unless water is contaminated source water

SLIDE: 5-1-14 E. Shut-off valve from external supply

1. Refill tank first F. Open drain valves G. Disconnect lines H. Drain pump if necessary I. Make pump ready for operation

RETIRED C

URRICULU

M

Page 216: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-1: Making The Pump Operational (From Tank) Page 8

SUMMARY: With a good understanding of the basics of pump operation, the driver/operator can then apply those skills in more complex situations. In fact, practice scenarios should closely resemble the real situations. This is essential for skill development. Entire operations can hinge on the driver/operator's ability to perform successfully. The driver/operator should strive for nothing less than complete competence. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 51-54, 288-290, and 315-323 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 217: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-2: Transitioning To An External Water Supply Page 1

TOPIC: 5-2: Transitioning To An External Water Supply

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1 and 5.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of transitioning to an external water supply by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 320-323 and 352-356

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 320-323 and 352-356

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 218: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-2: Transitioning To An External Water Supply Page 2

SLIDE: 5-2-1 SLIDE: 5-2-2

I. PROCEDURE A. Connect supply line to apparatus

1. Keep intake valve shut 2. Connect hose to appropriate intake 3. Bleed off air in supply line

How should the air in a supply line be purged?

a) Open bleed valve at inlet b) Charge line

SLIDE: 5-2-3 B. Open intake valve

When? 1. Once a continuous stream of water has been

discharged from bleed valve 2. Slowly and completely

SLIDE: 5-2-4 C. Pump panel adjustments

1. Pump discharge pressure a) Possible increase due to incoming psi b) Adjust accordingly

1) Simultaneously while opening intake valve 2) Per department SOPs

2. Tank-to-pump valve a) Leave open or close b) Per department SOPs

3. Tank fill valve a) Refill tank if adequate water supply is available b) Monitor in order to close valve if necessary

RETIRED C

URRICULU

M

Page 219: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-2: Transitioning To An External Water Supply Page 3

SUMMARY: The ability of the driver/operator to rapidly and effectively secure a continuous water supply from an external water source has prevented many emergency situations from resulting in a high loss of life and property. The skill and ability of the driver/operator to take immediate action in securing a water supply is imperative to successfully mitigating those incidents that warrant such. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 320-323 and 352-356 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 220: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-3: Operating From A Hydrant Page 1

TOPIC: 5-3: Operating From A Hydrant

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections: 5.2.1 and 5.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of operating from a hydrant by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 107-115, 323-334, and 357-361

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 107-115, 323-334, and 357-361

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIR

ED CURRIC

ULUM

Page 221: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 2

SLIDE: 5-3-1 What is the first consideration when selecting a hydrant?

I. HYDRANT CONSIDERATIONS A. The first consideration in selecting a hydrant is to

determine which hydrant is most appropriate in terms of fire fighting and safety needs

SLIDE: 5-3-2 B. Location

1. Safety a) Location to the incident

1) Too close to actual incident 2) Collapse zone

• Falling debris 3) Radiant heat 4) Overhead wires 5) Crossing main thoroughfares

• Same side of incident if possible 2. Distance to incident

a) Amount of hose on apparatus b) Friction loss

3. Obstacles a) Railroad tracks b) Road barriers/closures

C. Hydrant size and supply 1. Hydrant main size 2. Discharge diameter

What is the main disadvantage of connecting to a 2½" discharge?

a) Limits water flow

RETIRED C

URRICULU

M

Page 222: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 3

3. Grid versus dead-end main Which location is less desirable?

a) Dead-end mains are less desirable SLIDE: 5-3-3

II. SPOTTING THE APPARATUS A. At the hydrant

1. Front/rear suction a) Apparatus aimed at hydrant at a 45º angle or

less 1) Eliminate kinks

b) Distance out dependant upon length of supply line

c) Use apparatus to block traffic if possible 2. Side suction

If using the side intake, how should the front tires be positioned?

a) Front wheels at 45º angle to hydrant b) Distance out dependant upon length of supply

line 1) Eliminate kinks

c) Use apparatus to block traffic if possible B. At the incident

1. Per direction of Incident Commander/company officer

SLIDE: 5-3-4 III. HOSE EVOLUTIONS

A. Forward lay 1. Stopping at a hydrant, dropping the end of one or

more supply lines at the hydrant, and proceeding to the fire location

RETIRED C

URRICULU

M

Page 223: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 4

a) May use a four-way hydrant valve b) Second pumper connects to second discharge

of four-way 1) No interruption of flow

c) Second intake on four-way allows pumper connection for pressure increase

d) Equipped with a shut-off valve SLIDE: 5-3-5

B. Reverse lay 1. Hose is laid from the fire to the water source 2. Used when a pumper must first go to the fire

location so that a size-up can be made before laying a supply line

3. Most expedient method if apparatus must stay with water source

4. May be used in relay operations 5. Disadvantage

a) Equipment must be removed from the apparatus

SLIDE: 5-3-6 IV. HYDRANT CAPACITIES

A. Hydrant output capacity 1. Outlets

a) Number and size(s) NOTE: For hydrant color codes, refer to Unit 3 - Topic 4.

2. Main size a) Small feeder b) Dead-end main

B. A static pressure needs to be recorded from the master intake gauge prior to flowing water

C. Pressures defined

RETIRED C

URRICULU

M

Page 224: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 5

SLIDE: 5-3-7 1. Static

a) The water pressure in the water system, which is taken when the pump is full and the system has stabilized

b) The master intake gauge indicates the static pressure in the water system

What is residual pressure? SLIDE: 5-3-8

2. Residual a) Remaining pressure in the system when the

apparatus is discharging water b) The intake gauge reading is in the residual

pressure D. Percentage method

1. First, calculate the drop in pressure as a percentage after the first hoseline flows water

SLIDE: 5-3-9 2. Formula

a) % Drop = (Static – Residual)(100) Static

SLIDE: 5-3-10 3. Example

a) % Drop = (70 – 63)(100) 70

b) % Drop = (7)(100) 70

c) % Drop = 700 70

d) % Drop = 10 E. First-digit method

1. Quicker and easier method

RETIRED C

URRICULU

M

Page 225: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 6

2. Steps a) Find the difference in psi between the static

and residual pressures b) Multiply the first digit of the static pressure by

1, 2, or 3 to determine how many additional lines of equal flow may be added

SLIDE: 5-3-11 c) Additional water available at a hydrant d) Percent decrease of pumper intake pressure

determines additional water available 1) 0%-10% 3 times amount being

delivered 2) 11%-15% 2 times amount being

delivered 3) 16%-25% Same amount as being

available 4) 25+% More water might be

available, but not as much as is being delivered

3. Formula a) Difference in psi

1) Static pressure – Residual pressure 4. Example

a) Difference in psi = 65-58 b) Difference in psi = 7 c) First digit of static pressure x 1 d) 6 x 1 = 6 e) 7 is not less than 6 but is less than 12 (2 x 6),

so two more lines at 250 gpm each can be added

SLIDE: 5-3-12 V. HYDRANT PUMPING OPERATIONS

A. Establish a water supply 1. Flush hydrant

RETIRED C

URRICULU

M

Page 226: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 7

2. Connect supply line from hydrant to engine inlet 3. Open hydrant outlet 4. Open connected supply line intake

B. Pump panel operations 1. Monitoring gauges/valves

a) Master/compound pressure gauge 1) psi increases with incoming pressure

b) Transfer valve 1) In proper position prior to increasing rpm

• Based on gpm need of the incident c) Pressure relief valve

1) Set per department SOPs d) Tank-to-pump valve

1) Open if valve has a clapper • Per department SOPs

2. Charging the hoseline a) When requested b) Open gradually to avoid injury and water

hammer c) Increase throttle pressure to desired psi as

calculated VI. SHUTDOWN PROCEDURES

SLIDE: 5-3-13 A. Gauges/valves

1. "Tank Fill" valve a) Ensure engine water tank is full

2. Tank-to-pump valve a) Per department SOPs

3. Throttle a) Down to idle if not pumping

4. Intake valve closed a) Open bleed valve to relieve pressure

RETIRED C

URRICULU

M

Page 227: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-3: Operating From A Hydrant Page 8

SLIDE: 5-3-14 B. Hydrant

When shutting down a hydrant, what must you always be alert for?

1. Water hammer 2. Shutdown valve 3. Remove hose once pressure is relieved 4. Replace hydrant caps

SLIDE: 5-3-15 C. Disengage pump

1. When pumping evolution is complete 2. As directed by IC/company officer 3. Per department SOPs

SLIDE: 5-3-16 D. Supply hose

1. Drain water from hose as necessary 2. Wash/clean hose per department SOPs

RETIRED C

URRICULU

M

Page 228: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-3: Operating From A Hydrant Page 9

SUMMARY: Having the ability to effectively pump water into a hoseline or fire appliance by using a fire engine supplied by a fire hydrant is a critical and primary skill of any driver/operator. A key consideration all driver/operators should have is water supply, which is usually provided by the nearest available hydrant to the emergency incident. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 107-115, 323-334, and 357-361 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 229: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-4: Principles And Practices Of Drafting Operations Page 1

TOPIC: 5-4: Principles And Practices Of Drafting Operations

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1 and 5.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of principles and practices of drafting operations by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 334-346

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 334-346

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 230: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 2

SLIDE: 5-4-1 SLIDE: 5-4-2

I. PRINCIPLES OF LIFT A. All fire department pumpers should be capable of

pumping water from a static water supply B. The static water supply is most often located at a lower

level than the fire pump 1. It is not possible to pull water into the pump from a

lower level C. It is possible to evacuate some of the air inside the fire

pump What principle allows water to enter the pump from a lower static source?

1. A pressure differential (partial vacuum inside the pump), allows atmospheric pressure acting on the surface of the water to force water into the fire pump

SLIDE: 5-4-3 2. The weight of the water, combined with the

reduced air pressure acting on its surface, creates a balance

3. An airtight, non-collapsible waterway (hard intake hose) is needed between the fire pump and the body of water to be used

SLIDE: 5-4-4 D. Lift is affected by additional pressure losses

encountered 1. Any type of fire hose, strainer, or appliance creates

a certain amount of friction loss a) Proportional to the amount of water moving

through it 2. The inertia of or movement of water is an additional

pressure loss

RETIRED C

URRICULU

M

Page 231: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 3

3. The amount of energy consumed in getting the water at rest to begin to move and increase its velocity sufficiently to supply the amount of water needed

SLIDE: 5-4-5 4. The total pressure available to overcome all

pressure losses is limited to atmospheric pressure at sea level a) 14.7 psi

1) For every 1 psi of atmospheric pressure, water can be lifted 2.3 feet

b) Decreases .5 psi per 1,000 feet of elevation increase

SLIDE: 5-4-6 5. While the pump is moving water, the vacuum

reading on the master intake gauge indicates the remaining pump capacity

What is the maximum amount of vacuum that most pumps develop?

a) The maximum amount of vacuum that most pumps develop is approximately 22 inches of mercury

b) A reading that is approaching this amount indicates that the pump is close to the limits of its ability

SLIDE: 5-4-7 E. Cavitation - water being discharged from the pump

faster than it is coming in 1. "The pump is running away from the water" 2. Air cavities are created in the pump or bubbles

pass through the pump a) They move from the point of highest vacuum

into the pressurized section where they collapse or fill with fluid

RETIRED C

URRICULU

M

Page 232: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 4

b) The high velocity of the water filling these cavities causes a severe shock to the pump

c) May cause damage to the in pump 3. Temperature of the water, the height of the lift, and

the amount of water being discharged affect the point at which cavitation begins a) Water temperatures below 35°F or above 90°F b) Maximum theoretical lift is 33.9 feet in perfect

conditions 1) Realistic conditions can greatly reduce this

SLIDE: 5-4-8 4. Indications that a pump is cavitating

a) Hose streams and the pressure gauge on the pump will fluctuate

b) Sounds described as a popping or sputtering as the water leaves the nozzle

SLIDE: 5-4-9 c) Severe cavitation

1) The pump itself will be noisy 2) Sounding like gravel passing through it

d) The best indication - the lack of reaction on the pressure gauge to changes in the setting of the throttle 1) Increasing pump rpm will not increase

discharge pressure when there is no more water available to be supplied

SLIDE: 5-4-10 e) Caused by

1) Inadequate piping from the water tank 2) While operating from a poor hydrant or

supply system RETIR

ED CURRIC

ULUM

Page 233: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 5

When is cavitation most likely to occur?

3) Most often occurs during drafting operations

SLIDE: 5-4-11 II. SELECTING A DRAFTING SITE

A. Dictated by the following factors 1. Amount of water available 2. Type of water 3. Accessibility of water

SLIDE: 5-4-12 B. Amount of water available

1. Size of static source is important a) Due to the fact that there needs to be a

minimum of 24 inches of water all around the strainer

2. Types of sources such as shallow streams can be dammed to increase water depth a) Shallow drafting strainers are also available

3. Bodies of water with tidal movements may not be dependable all the time a) Low tide can make a site unusable

SLIDE: 5-4-13 C. Type of water

1. In an emergency, any water can be used 2. Nonpotable, salt, or contaminated water can

damage the pump What must be done to the pump if contaminated water is used?

a) If these types of sources are used, the pump should be thoroughly flushed

RETIRED C

URRICULU

M

Page 234: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 6

3. Water with debris can clog suction strainers and limit the capacity that can be pumped

4. Water with high concentrations of sand or dirt can pass into the pump and severely damage components a) Sand can be forced into the pump packing

under discharge pressure b) The packing then becomes contaminated and

can not be adjusted SLIDE: 5-4-14

D. Accessibility 1. Accessibility is an important factor in reducing

amount of lift a) Atmospheric pressure has to overcome

elevation and friction losses b) As lift increases

1) Elevation pressure increases 2) Less friction loss can be overcome 3) Capacity of the pump decreases

c) Pumpers are rated to flow their capacity at 10 feet of lift

d) Most pumpers in good condition can lift water 23 or 24 feet

e) Practically 20 feet is the maximum considered What capacity can be expected at 20 feet of lift?

1) The pump's capacity with this amount of lift is 60%

f) It is important to keep lift to a minimum SLIDE: 5-4-15

2. Others considerations a) Ground stability

RETIRED C

URRICULU

M

Page 235: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 7

b) Time of year c) Connecting hoselines d) Safety of the driver/operator

SLIDE: 5-4-16 III. SPOTTING THE APPARATUS

A. Once a proper site is identified, the driver/operator should move the apparatus into place 1. Sometimes can be parked and the suction hose

deployed 2. Oftentimes the opposite is true

a) Adequate drafting sites can have limited access

b) Suction hose has to be connected or partially deployed

c) The apparatus is then moved into place B. Once the apparatus is in its final position, the brake

must be set and the wheel chocks in place C. The sections of hard suction and strainer are then

connected 1. Make sure all gaskets are in place 2. All connection need to be air tight

a) Use a rubber mallet if necessary SLIDE: 5-4-17

D. Ensure that there is enough help during the connection process 1. To keep the hose out of the dirt 2. For safety of operation

E. Attach strainer rope F. Ensure that no part of the suction hose is above the

eye of the pump RETIR

ED CURRIC

ULUM

Page 236: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 8

Why must the eye of the pump be the highest point in the suction hose?

1. An air pocket may form and prevent effective drafting

G. Secure the strainer rope 1. Strainer should be suspended off the bottom of the

water source a) Tie rope off to the pumper, tree, or other

natural object 2. Other objects such as roof ladders or scoop

shovels can be used to keep the strainer off the bottom if necessary

SLIDE: 5-4-18 IV. PRIMING THE PUMP AND BEGINNING OPERATIONS

A. The first step in operation is to prime the pump 1. If operating a two stage pump, the pump should be

placed in the PARALLEL position Why is PARALLEL the preferred position for the transfer valve?

a) In SERIES, air can become trapped in the pump

2. Set engine rpms a) Transfer case driven primers need 1,000 to

1,200 rpms to operate optimally b) Electric motor primers should operate at about

1,000 to 1,200 rpms 1) Helps ensure that the alternator is charging

sufficiently 2) Also helps to prevent the loss of prime

once achieved c) Vacuum primers should be operated at the

lowest engine rpms without stalling

RETIRED C

URRICULU

M

Page 237: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 9

3. Operate primer 4. Observe the master intake gauge

a) One inch of vacuum lift equals about one foot of lift

5. Observe physical indicators a) As the hose fills, the weight of water will cause

it to drop and b) The primer discharges water on the ground

How long should the priming process take?

c) Entire process normally takes 10-15 seconds, but should not take any more than 30 seconds for a 1,250 gpm pumper 1) Up to 45 seconds for a 1,500 gpm pumper

6. Increase engine rpms prior to opening discharge valves a) Pressure should be boosted to 50-100 psi

SLIDE: 5-4-19 7. Open valve(s) slowly

a) Observe master intake gauge b) If the pressure drops below 50 psi, allow

pressure to stabilize before continuing 1) Reactivate primer if it continues to drop

c) This helps prevent air from entering the pump 8. If lines are not ready to be charged

a) Discharge water through a waste line or "Tank Fill" valve 1) Helps keep prime and pump cool

b) Be careful as to not compromise vehicle stability 1) By soaking the ground below

RETIRED C

URRICULU

M

Page 238: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-4: Principles And Practices Of Drafting Operations Page 10

c) Be careful as to not compromise water source 1) Waste line can be directed back to the

source as long as it does not disrupt the water and cause air to be drawn into the suction hose

B. Operating from draft 1. Monitor all gauges and be prepared to correct any

problem 2. Watch for developing problems

SLIDE: 5-4-20 V. SHUTTING THE OPERATION DOWN

A. Fill tank if source in not contaminated B. Slowly decrease rpms C. Take the pump out of gear D. Allow pump to drain E. Allow engine temperature to stabilize

SLIDE: 5-4-21 F. Shut-off engine G. Disconnect all hose and attachments H. Operate primer for a few seconds

Why operate the primer after operations and the pump is empty?

1. This lubricates the priming pump and helps preserve it

I. Flush pump if unclean or contaminated water was drawn through the pump

RETIRED C

URRICULU

M

Page 239: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-4: Principles And Practices Of Drafting Operations Page 11

SUMMARY: Drafting, oftentimes, is rarely practiced or used. This is especially true in departments with reliable pressurized water systems. It is however, an essential skill that needs to be as polished as any other. The need for a drafting operation can occur at any time. The situation should not be further complicated by the lack of preparation. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 334-346 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 240: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-5: Principles Of Relay Pump Operations Page 1

TOPIC: 5-5: Principles Of Relay Pump Operations

TIME FRAME: 1:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1, 5.2.2, 5.2.4, 8.2.1, and 8.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of the principles of relay pump operations by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 395-413 and 583

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 395-413 and 583

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 241: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 2

SLIDE: 5-5-1 SLIDE: 5-5-2

I. RELAY PUMPING PRINCIPLES A. Definitions

1. Relay a) Using two or more pumpers to move water

from distances that would require excessive pressures if only one pumper was employed

2. Relay operation a) Using two or more pumpers to move water

over a long distance by operating them in series

SLIDE: 5-5-3 b) Water discharged from one pumper flows

through hoses to the inlet of the next pumper, and so on

c) Also called relay pumping B. Purpose

What is the purpose of relay pumping?

1. To boost inadequate water pressure over an extensive distance from source to incident

SLIDE: 5-5-4 C. Apparatus relay principles

1. Source pumper a) Apparatus connected to the actual water

source 1) Largest capacity pumper 2) Strongest operational pumper

2. Relay pumper (in-line pumper) a) Pumper(s) connected within a relay b) Receives water from the source pumper c) Boosts the water pressure and supplies water

to the next in-line pumper or attack pumper

RETIRED C

URRICULU

M

Page 242: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 3

SLIDE: 5-5-5 3. Attack pumper

a) Pumper located at the incident scene b) Receives water from the in-line pumpers c) Supplies water to the appliances necessary for

fire suppression 4. Determination of maximum relay capacity

What is the maximum capacity of a relay operation limited to?

a) Limited to the capacity of the smallest pump b) Limited to the smallest hoseline used within the

relay II. TYPES OF RELAY PUMPING OPERATIONS NOTE: There are two basic designs or relay pumping

operations: The maximum distance relay and the constant pressure relay.

SLIDE: 5-5-6 A. Maximum distance relay

1. Involves flowing a predetermined volume of water for the maximum distance

SLIDE: 5-5-7 2. Maximum distance relay chart

a) Used to determine maximum pumping distance through a particular hose lay

b) Based upon 1) 20 psi residual pressure available at the

next, in-line pumper 2) Discharge pressure of 200 psi for 2½" and

3" hose 3) Discharge pressure of 185 psi for 4" and 5"

hose

RETIRED C

URRICULU

M

Page 243: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 4

NOTE: Table 13.1 on page 402 in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition must be understood and used by the student to determine the distance that a certain flow may be pumped through the type of hose carried on the apparatus.

SLIDE: 5-5-8 3. Minimum pump capacities based upon maximum

distance relay chart (Table 13.3) and the above criteria a) 250 and 500 gpm flows: a 750 gpm rated

pumper b) 750 gpm flow: a 1,250 gpm rated pumper c) 1,000 gpm flow: a 1,500 gpm rated pumper d) 1,250 gpm flow: a 1,750 gpm rated pumper

4. Formula to determine number of pumpers needed to relay

SLIDE: 5-5-9 Equation U Relay distance MDR + 1 = Total number of pumpers MDR = maximum distance relay lengths table

NOTE: Tables 13.1 on page 402 in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition.

5. Example a) 2,000

1,600 = 1.25 + 1 = 2.25 or 3 pumpers b) Always round up to the nearest whole number

when using the above formula 1) If answer is 3.2, you actually need 4

pumpers to achieve the flow SLIDE: 5-5-10

B. Constant pressure relay

RETIRED C

URRICULU

M

Page 244: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 5

1. Method establishes the maximum flow available from a particular relay setup a) By using a constant pressure in the system

2. Dependant upon a constant flow provided on the fireground

3. To maintain the flow, the driver/operator may a) Open a discharge b) Secure a waste line to handle above the fire

flow SLIDE: 5-5-11

4. Advantages What are some advantages of this method?

a) Speeds relay activation b) Requires no complicated calculations c) Radio traffic reduced d) Attack pumper driver/operator able to govern

hoselines with greater ease e) Driver/operator guides and adjusts pressure to

one constant figure 5. Constant pressure relay formation

SLIDE: 5-5-12 a) Position attack pumper at the fire b) Largest capacity pumper at the water source c) Lay hose from the relay pumpers according to

department SOPs 1) Leave minimum of two hose lengths in bed

in case of a hose failure d) Connect supply lines to the pumpers e) Driver/operators (except source pumper) open

an unused discharge gate if pumper has no relay relief valve

RETIRED C

URRICULU

M

Page 245: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 6

f) Pump 175 psi from the water source g) Driver/operator on first relay pumper closes the

unused discharge gate once a steady stream of water occurs

SLIDE: 5-5-13 h) Relay pumper then pumps to next pumper at

175 psi i) Driver/operator sets the pressure regulating

device 1) Each successive driver/operator follows

the same procedure j) Attack pumper driver/operator adjusts the

discharge pressure(s) to supply the attack line(s)

SLIDE: 5-5-14 k) Maintain the flow from the attack pumper

during temporary shutdowns 1) One or more discharge gates as waste or

dump lines l) For a ruptured hoseline, open a discharge gate

on the relay pumper before the rupture to dump water until line is replaced

m) For additional water on the fireground, lay additional hoselines between apparatus

SLIDE: 5-5-15 6. Pump discharge pressure at 175 psi until

a) Intake pressure from pressurized sources drops below 20 psi

What happens if the residual does drop below 20 psi?

1) Danger of cavitation b) Operating hand throttle does not increase rpm

1) Engine reached governed speed

RETIRED C

URRICULU

M

Page 246: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 7

7. Constant pressure of 175 psi may be modified a) Variations in relay pumper spacing

1) Increase for greater spacing 2) Decrease for lesser spacing

b) Severe elevation differences 1) Decrease pumping downhill 2) Increase pumping uphill

c) Increase fire flow d) Large diameter hose

1) Requires lower discharge pressure SLIDE: 5-5-16

8. Relay pressure adjustment a) Increase relay pressure

1) Adjust the source pumper until the desired pressure is reached

2) Adjust successive pumper similarly b) Decrease relay pressure

1) Attack pumper throttles down

• Open dump line 2) Relay pumpers toward the water source, in

decreasing succession SLIDE: 5-5-17

III. OPERATIONAL CONSIDERATIONS/GUIDELINES A. Basis for relay operation

1. Amount of water required at the emergency scene 2. The distance from the emergency scene to the

water source B. Methods to increase flow through a relay RETIR

ED CURRIC

ULUM

Page 247: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 8

What are some methods used to increase flow through a relay?

1. Increase size of hose a) Increase numbers of hoselines in relay

2. Increase pump discharge pressure of the pumpers used in the relay

3. Increase number of pumpers used in relay SLIDE: 5-5-18

C. General rules 1. A relay operation always begins with the source

pumper 2. Largest diameter hose should be used at the

beginning of the relay SLIDE: 5-5-19

3. Once water has been established, the source pumper opens an uncapped discharge or allows water to waste through a dump line until the first relay pumper is ready for water a) From static source, this prevents losing prime

4. Relay pressure not to exceed the maximum operating pressure rating for the hose

5. Elevation pressures a) Uphill

1) Calculate elevation pressure and friction loss

b) Downhill 1) Calculate additional psi and friction loss

due to lower elevation SLIDE: 5-5-20

D. Placing a relay into operation RETIR

ED CURRIC

ULUM

Page 248: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 9

At a relay operation, where should the largest capacity pumper be placed?

1. The largest capacity pumper should be at the source

2. Source and relay pumper ready for water a) Discharge supply the hoseline on the source

pumper is opened b) Valve on the dump line is closed in conjunction c) If only minutes before receiving water, the

pump on the receiving pump may be engaged. If longer, disengage pump as not to run dry and overheat

At what psi should the intake pressure be maintained?

3. Maintain an intake pressure of 20 psi 4. If relay pumper is receiving an intake pressure

greater than 50 psi a) Adjust valve on the dump line on the relay

pumper to a maximum residual of 50 psi SLIDE: 5-5-21

5. Receiving water at the attack pumper a) Bleed out air from the supply line

1) Open bleed valve on the intake being used b) Open discharge c) Close dump line

E. Operating the relay 1. Once water is flowing

a) Driver/operators set automatic pressure control devices

2. Attack pumper has an intake relief valve a) Set between 50 and 75 psi

RETIRED C

URRICULU

M

Page 249: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-5: Principles Of Relay Pump Operations Page 10

3. Small variations in pressure are not significant a) Intake pressure should not drop below 20 psi

nor increase above 100 psi SLIDE: 5-5-22

F. Relay operation shutdown 1. Shutdown from the fire scene first 2. Driver/operators should shut down in succession

a) Slowly decrease the throttle b) Open the dump line c) Take pump out of gear

RETIRED C

URRICULU

M

Page 250: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-5: Principles Of Relay Pump Operations Page 11

SUMMARY: There is a high likelihood that at some point in your career, you will be placed in a situation where the water source is at a greater distance from the emergency than a single pumper can reasonably supply. With a thorough knowledge of relay operations, you should be able to effectively deploy fire attack lines by recognizing the need and utilizing the necessary resources appropriately. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 395-413 and 583 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 251: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 1

TOPIC: 5-6: Troubleshooting Pump Operations

TIME FRAME: 1:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 4.2.1, 4.2.2, 5.1.1, 5.2.1, 5.2.2, 8.1.1, 8.2.1, 8.2.2, and 10.1.1

BEHAVIORAL OBJECTIVE:

Condition: Given an activity and written test

Behavior: The student will confirm a knowledge of troubleshooting the pump by completing the activity and written test

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 70-75 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 366-373

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Group Activity 5-6-1: What's Wrong!

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 366-373

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 252: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 2

ACTIVITY 5-6-1: Complete the activity in the student supplement.

NOTE: DO NOT lecture on this material. Activity 5-6-1 provides the opportunity for the students to learn this information in a dynamic approach. If necessary, use the information below to clarify any points of debate brought up by the students during the review of the activity.

I. TROUBLESHOOTING PROBLEMS COMMON TO ALL TYPES OF OPERATIONS A. Unable to get a reading on the pressure gauge when

the pump is put in service 1. Symptom: Green light indicating that the pump shift

transfer is complete is not illuminated a) Probable cause

1) Pump drive system is not fully engaged b) Possible corrective action

1) Check the position of the shift transfer control • If it is in the proper position, release

the transfer control • Allow the gears to turn

• Operate shift transfer again c) Possible corrective action - automatic

transmission 1) Repeat pump shifting procedure to ensure

power transfer to pump operation 2. Symptom: Green light is on, no mph reading

registers on the speedometer a) Probable cause

1) Clutch is not engaged b) Possible corrective action

1) Check the remote clutch control on the driver/operator's panel

RETIRED C

URRICULU

M

Page 253: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 3

c) Probable cause 1) Road transmissions is not in the proper

gear 2) Automatic transmission selector is in wrong

position d) Possible corrective action

1) Check the shift lever • Lock it in the proper position for pump

operation 3. Symptom: Speedometer reading is normal for

pump operation, all indications are correct, and rpm reading is as specified a) Probable cause

1) No water in pump b) Possible corrective action

1) Check water supply 2) Ensure that all applicable valves are open 3) Primer pump may need to be operated

• To eliminate air in the main pump c) Probable cause

1) Gauge is defective • Pressure is there but not reading on

the master pressure gauge d) Possible corrective action

1) Check the shutoff (snubber) dampening valve associated with the gauge

2) Open the gate valve to one of the capped discharge outlets • Look for pressure reading on the

individual line gauge 3) Open an uncapped discharge outlet from

the pump • To see if water is discharged under

pressure

RETIRED C

URRICULU

M

Page 254: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 4

B. Pump will not develop sufficient pressure 1. Symptom: The rpm reading on the tachometer is

normal when compared with the UL plate a) Probable cause - two-stage pump

1) Pump transfer valve is in the wrong position

b) Possible corrective action 1) Transfer valve should be in the SERIES or

PRESSURE position anytime more than 200 psi is needed

c) Probable cause 1) Swing check valve may be leaking if the

pump is in the SERIES position d) Possible corrective action

1) Set the discharge pressure within 50 psi of compound (intake) pressure

2) Change from SERIES to PARALLEL 3) Listen for the metallic sound of the valve

operating 4) If it is blocked, remove the strainer from the

large intake and clear the valve seat of any debris

e) Probable cause 1) Transfer valve has not completed its travel

and is only partially operated f) Possible corrective action

1) Check all mechanical and electrical indicators

2) Observe pressure gauge readings as valve is operated

3) If equipped, use manual override controls to complete valve operation

4) May be possible to assist the action of the valve mechanically if the power transfer mechanism is faulty

RETIRED C

URRICULU

M

Page 255: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 5

g) Probable cause - automatic transmission 1) Transmission not staying in pumping gear

lockup and is downshifting as load increases

h) Possible corrective action 1) Remove pump from service 2) Must be adjusted or repaired

i) Probable cause 1) Wear on the clearance rings inside the

pump may cause excessive slippage j) Possible corrective action

1) Take out-of-service until repaired 2. Symptom: Relief valve is operating and the

indicator light is on a) Probable cause

1) Relief valve pressure adjustment set too low

b) Possible corrective action 1) Increase operating pressure of relief valve

• By turning the adjustment control clockwise

• Until it closes 3. Symptom: Indicator light shows that the relief valve

is closed a) Probable cause

1) Relief valve may be stuck open or may not be properly seated

• Allows water to bypass back to the intake

b) Possible corrective action 1) Turn the relief valve operating control to

the OFF position

RETIRED C

URRICULU

M

Page 256: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 6

2) Increase the setting of adjustment control to maximum clockwise position

3) Exercise valve

• By rapidly turning control valve on and off or

• Alternately increasing and decreasing the pressure adjustment control

• To cause valve to operate 4. Symptom: Engine rpm cannot be raised to the level

required as determined by the UL plate, even at full throttle; tachometer reading is low and pressure gauge reading is too low a) Probable cause

1) Flow requirements may be exceeding the capacity of the pump

b) Possible corrective action 1) Capacity of pump in the SERIES or

PRESSURE position is limited to 50% of its rated capacity at 250 psi and

2) 70% at 200 psi net pump pressure c) Probable cause

1) Throttle linkage may have slipped or be stuck

d) Possible corrective action 1) Check linkage action 2) It may be possible to override action of the

throttle

• By using the accelerator or hand throttle in the cab

or

• Manually operating the linkage at the carburetor

RETIRED C

URRICULU

M

Page 257: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 7

e) Probable cause 1) Severe engine overheating can reduce the

power available to drive the pump f) Possible corrective action

1) Check engine temperature gauge 2) Adjust auxiliary cooling valve

• To maintain proper operating temperature

3) Check level of coolant in radiator

• If it is too low and the water being pumped is clean and pure, open radiator fill valve

• To bring the coolant up to proper level g) Probable cause

1) Reduced engine power h) Possible corrective action

1) No field correction 2) If additional pressure is essential, use

another pumper 3) Take out-of-service until repaired

C. Pump is unable to supply its rated capacity 1. Symptom: The rpm reading on the tachometer is

normal when compared to the UL plate a) Probable cause - Two-stage pump

1) Transfer valve is wrong position b) Possible corrective action

1) Transfer valve should be in PARALLEL or VOLUME position anytime 50% or more of the capacity of the pump is needed

c) Probable cause 1) Swing check valve is not opening

completely

RETIRED C

URRICULU

M

Page 258: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 8

d) Possible corrective action 1) Remove strainer from large intake opening

on each side of pump 2) Make sure valve swings freely

• By inserting a rod and pushing on the face of valve

2. Symptom: Intake gauge registers "0" or has a positive pressure indicated a) Intake pressure or supply is not the problem b) Probable cause

1) Blockage in the waterways of the pump

• An object lodged inside the impeller can reduce the capacity

c) Possible corrective action 1) Thoroughly back-flush the pump

• In accordance with manufacturer's recommendations and specifications

• By connecting a supply line to the highest discharge outlet and opening the large intake fittings

d) Probable cause 1) Wear in the pump, usually the clearance

rings or relief valve

• Allowing slippage from the discharge back to the intake

e) Possible corrective action 1) Take out-of-service until repaired

3. Symptom: Intake compound gauge is registering a high vacuum, and the discharge pressure gauge is fluctuating (cavitation) a) Probable cause

1) Blockage of strainer at the intake fitting of pump

RETIRED C

URRICULU

M

Page 259: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 9

b) Possible corrective action 1) Disconnect intake line 2) Clean any accumulated debris from

strainer c) Probable cause

1) Inadequate water supply or supply lines d) Possible corrective action

1) Connect additional supply line to intake of the pump

2) Reduce the amount of discharge lines being supplied

3) Lower the discharge pressure

• To reduce the amount of water flowing through the lines

4. Symptom: Unable to develop enough engine rpm at full throttle to supply the rated capacity a) Probable cause

1) Flow requirements may be exceeding the capacity of the pump

b) Possible corrective action 1) Capacity of pump in the SERIES or

PRESSURE position is limited to 50% of its rated capacity at 250 psi and

2) 70% at 200 psi net pump pressure c) Probable cause

1) Throttle linkage may have slipped or be stuck

d) Possible corrective action 1) Check linkage action 2) It may be possible to override action of the

throttle

RETIRED C

URRICULU

M

Page 260: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 10

• By using the accelerator or hand throttle in the cab or Manually operating the linkage at the carburetor

e) Probable cause 1) Severe engine overheating can reduce the

power available to drive the pump f) Possible corrective action

1) Check engine temperature gauge 2) Adjust auxiliary cooling valve

• To maintain proper operating temperature

3) Check level of coolant in radiator

• If it is too low and the water being pumped is clean and pure, open radiator fill valve

• To bring the coolant up to proper level g) Probable cause

1) Reduced engine power h) Possible corrective action

1) No field correction 2) If additional pressure is essential, use

another pumper 3) Take out-of-service until repaired

D. Pump overheats while in operation 1. Symptom: Warning light is on or seen through

physical observation a) Probable cause

1) Inadequate flow through the pump while operating under pressure

b) Possible corrective action 1) Open booster cooling valve

RETIRED C

URRICULU

M

Page 261: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 11

2) Set circulator valve to TANK or SPILL position as appropriate

3) Open tank fill valve if it is connected to the discharge side of the pump

4) Use the booster line to maintain a minimum flow of water while pumping

c) Probable cause 1) Excessive throttle on relief valve-equipped

pumps d) Possible corrective action

1) Reduce engine rpm E. Relief valve is inoperative or slow acting

1. Symptom: Pressure surges are excessive when individual hoselines are shutdown a) Probable cause

1) Strainer in the pressure line to the pilot valve is dirty

b) Possible corrective action 1) Open the flush line while pumping clean

water to back-flush the in-line strainer 2) Remove strainer element and wash in

clear water c) Probable cause

1) Relief valve is corroded or dirty d) Possible corrective action

1) If relief valve is equipped with a shut-off

• Set the discharge pressure on the pump to 150 psi

• Set the relief valve adjustment control to minimum

• Alternately turn the valve off and on for 60 seconds

RETIRED C

URRICULU

M

Page 262: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 12

2) If no control is provided

• Set the pump pressure to 150 psi 3) Operate the relief valve by cranking the

adjustment control in and out rapidly e) Probable cause

1) Defective relief valve f) Possible corrective action

1) Have relief valve serviced/repaired II. TROUBLESHOOTING TANK OPERATIONS

A. Unable to establish an adequate operating pressure or a loss of pressure occurs when the first discharge valve is opened 1. Symptom: Pressure increases with the engine rpm

up to a point, then holds steady or fluctuates a) Probable cause

1) Trapped air in pump b) Possible corrective action

1) Operate priming pump

• Per department SOPs 2) Switch transfer valve between SERIES to

PARALLEL several times

• At low rpm 3) Open discharge in order to "burp" out air 4) Open pump-to-tank valve or small

handlines

• Increase water velocity through pump c) Probable cause

1) Automatic transmission - intermittent slippage

d) Possible corrective action 1) Have transmission repaired or adjusted

RETIRED C

URRICULU

M

Page 263: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 13

e) Probable cause 1) Low transmission fluid level

f) Possible corrective action 1) Increase fluid level

g) Probable cause 1) Transmission not remaining in correct

pumping gear h) Possible corrective action

1) Have transmission repaired or adjusted B. Fluctuation of the pressure gauge and a reduction of

discharge pressure when additional lines are put in service 1. Symptom: High vacuum reading on intake

compound gauge a) Probable cause

1) Tank-to-pump valve partially closed b) Possible corrective action

1) Fully open and lock if possible c) Probable cause

1) Tank-to-pump valve piping too small to supply the amount of water required from hoselines

d) Possible corrective action 1) Shutdown hoselines

• As fire permits 2) Reduce discharge pressure until fluctuation

stops and pressure gauge begins to drop C. While pumping, the discharge pressure drops to a low

value and water supply is interrupted 1. Symptom: Compound gauge on the intake reads

"0" or fluctuates; engine speed increases

RETIRED C

URRICULU

M

Page 264: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 14

a) Probable cause 1) Air leak in the pump

b) Possible corrective action 1) Check caps and valves on the intake side

of the pump c) Probable cause

1) Water supply from the tank is nearly or completely exhausted

d) Possible corrective action 1) Reduce pressure until gauge becomes

steady and flow resumes 2) Arrange for another water supply as soon

as possible III. TROUBLESHOOTING HYDRANT OPERATIONS

A. Suction line collapses when the discharge valve to a hoseline is opened 1. Symptom: Intake pressure drops to less than "0"

and discharge pressure also drops a) Probable cause

1) Too small of a suction line for needed water flow

b) Possible corrective action 1) For 2½" or 3" suction line, bring into the

large intake through a suction siamese or bell reducer

2. Symptom: Water is coming out of the ground around the barrel of the hydrant a) Probable cause

1) Hydrant not fully opened b) Possible corrective action

1) Turn hydrant counterclockwise until completely opened

RETIRED C

URRICULU

M

Page 265: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 15

B. While supplying water, the suction line collapses and the pump begins to cavitate 1. Symptom: Intake pressure drops to less than "0"

and discharge pressure fluctuates and decreases a) Probable cause

1) Greater water demand by the hoselines being supplied

b) Possible corrective action 1) Reduce the number of hoselines in service 2) Reduce the flow settings on the nozzles 3) Reduce the PDP until cavitation stops

c) Probable cause 1) Additional demands on the water system

may have reduced the residual pressure in the system

d) Possible corrective action 1) Decrease water use by

• Changing the nozzle settings

• Taking attack lines out-of-service 2) Obtain a supplementary water supply from

another hydrant, relay, or water shuttle C. While supplying water, the suction line is charged and

the pump begins to cavitate 1. Symptom: Intake pressure drops to less than 0;

discharge pressure fluctuates and decreases a) Probable cause

1) Pump inlet from hydrant closed 2) Clogged strainer

b) Possible corrective action 1) Open pump inlet valve fully 2) Place an additional suction line in-service 3) Inspect inlet strainer for obstructions

• Clean if necessary

RETIRED C

URRICULU

M

Page 266: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 16

IV. TROUBLESHOOTING DRAFTING OPERATIONS A. Pump will not prime

1. Symptom: Unable to get water into the pump through the hard suction hose and no vacuum reading is registered on the intake compound gauge a) Probable cause

1) Drain valve left open b) Possible corrective action

1) Make sure master drain valve is fully closed

2) Check individual drain valves for governor, auxiliary cooler, and so on

c) Probable cause 1) Intake valves left open or caps not tight

d) Possible corrective action 1) Tighten caps on large suction fittings that

are not being used 2) Make sure tank-to-pump valve is closed

• If tank is empty e) Probable cause

1) Intake relief valve may be leaking f) Possible corrective action

1) If relief valve is equipped with a shut-off valve, close it

2) If it has fire hose threads on the discharge opening, put a cap on it

g) Probable cause 1) Suction hose connections are not airtight

h) Possible corrective action 1) Listen for air leaks at each connection 2) Tighten with a rubber mallet if any

connection appears to be leaking

RETIRED C

URRICULU

M

Page 267: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 17

i) Probable cause 1) Suction hose connection to floating strainer

not airtight j) Possible corrective action

1) Tighten coupling with a rubber mallet or spanner wrench

k) Probable cause 1) Pump packing is too loose and leaking air

l) Possible corrective action 1) Take out-of-service until packing can be

adjusted or pump repacked m) Probable cause

1) Not operating the primer long enough to get rid of air

n) Possible corrective action 1) Typical pump requires 15 seconds to prime

through 20 feet of suction

• May take as long as 30 seconds to prime completely

o) Probable cause 1) Tank-to-pump valve not sealing with an

empty tank p) Possible corrective action

1) Temporary

• Partially fill tank 2) Permanent

• Repair valve 3) Engage pump

• Build up 100 psi

• Discharge water from booster line

• While keeping end of suction hose submerged

RETIRED C

URRICULU

M

Page 268: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 18

• Take cap off end and install strainer • Slowly close tank-to-pump valve • While continuing to flow water from

booster line • Pump is now primed

q) Probable cause 1) Engine rpm is too low

r) Possible corrective action 1) Engine rpm should be as specified in

manufacturer's instructions • Usually 1,000 to 1,200 rpm

s) Probable cause 1) No oil in the reservoir for the priming pump

t) Possible corrective action 1) Supply of oil should be carried on any

pumper that uses oil for priming • If this is the case, oil can be put in the

reservoir to replenish supply 2) If regular priming oil is not available,

putting water in reservoir may enable primer to operate • It should be thoroughly cleaned out

and a supply of oil put in at the first opportunity

2. Symptom: Electric motor will not operate to drive the primer a) Probable cause

1) Bad battery or poor connection between the cable and battery terminals

b) Possible corrective action 1) Inspect battery terminals

• If they are corroded, may be possible to loosen the fastening and clean the terminal sufficiently to run

RETIRED C

URRICULU

M

Page 269: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 19

3. Symptom: Very little air is being discharged from the primer a) Probable cause

1) Priming valve may have not opened b) Possible corrective action

1) Ensure that the priming activation lever is fully engaged in order to open the valve

c) Probable cause 1) Defective primer

d) Possible corrective action 1) If primer will not operate for mechanical

reasons • Prime the pump by connecting the

hard suction hose to the pump and

• Installing the cap on the end of the hose then

• Submerging hose under water • Open tank-to-pump valve • Allowing suction hose to fill with water

as well as the pump B. Pump loses its prime when the first discharge valve is

opened and water begins to flow 1. Symptom: Discharge pressure gauge drops sharply

a) Probable cause 1) Valve may have been opened too rapidly

b) Possible corrective action 1) Carefully observe pressure gauge 2) While slowly opening discharge valve 3) If pressure begins to drop suddenly

• Pause and allow it to stabilize before continuing

RETIRED C

URRICULU

M

Page 270: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 20

c) Probable cause 1) Pump not completely primed 2) Still had some air trapped in it when primer

was released d) Possible corrective action

1) Allow primer to continue to operate

• Until a steady stream of water is discharging from it

• Before closing the priming valve 2) If pressure drops suddenly while opening a

discharge valve, operate primer momentarily

• To remove any remaining air from the pump

e) Probable cause 1) Pump may not be turning fast enough to

sustain the prime when water begins to flow

f) Possible corrective action 1) Adjust discharge pressure to 75 psi or

more 2) Before opening the discharge valve

g) Probable cause 1) Priming valve can stick causing air to leak

into pump h) Possible corrective action

1) Make sure priming valve control is in CLOSED position

2) Exercise valve

• To clear any debris from valve seat i) Probable cause

1) Rock or debris in impeller

RETIRED C

URRICULU

M

Page 271: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 21

j) Possible corrective action 1) Take out-of-service until repaired

2. Symptom: Reading on pressure gauge drops sharply and intake gauge returns to "0" reading a) Probable cause

1) High spot in suction line trapped a quantity of air when pump was primed

2) Air drawn into pump when the water began to move through suction hose

b) Possible corrective action 1) Attempt to eliminate high spot, by moving

suction hose 2) Prime pump again 3) If high spot cannot be eliminated, it may be

possible to scavenge the air from the suction hose

• By operating the primer again each time the pressure begins to drop

C. Pump loses its prime during the course of a pumping operation 1. Symptom: Pump loses its prime when all nozzles

are closed and no water is flowing a) Probable cause

1) Air leak on the intake side of pump b) Possible corrective action

1) Make sure all connections are airtight c) Probable cause

1) Packing may be misadjusted

• Allowing air to break into the pump around the shaft

d) Possible corrective action 1) Open a discharge outlet

RETIRED C

URRICULU

M

Page 272: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 22

2) Allow water to flow at all times

• To maintain a higher vacuum reading in the intake side of the pump

3) If the problem becomes acute, take out-of-service until repaired

2. Symptom: Pump loses its prime when it is operating near its maximum capacity and the vacuum reading on the intake gauge is near "0" and is fluctuating a) Probable cause

1) Whirlpool over strainer is allowing air to get into the pump through the suction hose

b) Possible corrective action 1) Put a board or other object over the

whirlpool

• To break up the whirling motion and

• Stop air from getting into the suction hose

c) Probable cause 1) Air leak on the intake side of the pump

d) Possible corrective action 1) Check all connections

D. Pump goes into cavitation when the flow increases 1. Symptom: Intake gauge registers more than 22

inches of vacuum, the pressure gauge fluctuates and decreases reading a) Probable cause

1) Flow exceeds the capacity of the pump at the lift that is required

• Capacity of pump decreases as the lift increases

RETIRED C

URRICULU

M

Page 273: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 23

b) Possible corrective action 1) Reduce flow or demand on pump

• At a 20-foot lift, the lift capacity of the pump is only 60% of what is would be with a 10-foot lift

c) Probable cause 1) Suction line may be partially blocked

d) Possible corrective action 1) Debris blocking strainer on suction hose

• Clean strainer manually 2) Debris is trapped in strainer at the pump

intake

• Shutdown the pump

• Remove suction hose

• Clean the strainer e) Probable cause

1) Inner rubber liner of suction hose has become separated from hose

2) Resulting in restriction caused by the "bubble" of inner liner

f) Possible corrective action 1) Suction hose can collapse

• Will have to be replaced if reduced capacity is unacceptable

2) Replace suction hose V. TROUBLESHOOTING RELAY PUMP OPERATIONS

A. Intake supply line collapses when throttle setting is increased to establish initial discharge pressure as required 1. Symptom: Intake pressure gauge reading is

negative, reading vacuum instead of pressure

RETIRED C

URRICULU

M

Page 274: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 24

a) Probable cause 1) Dump line or uncapped discharge used to

waste water while establishing the relay may still be open

b) Possible corrective action 1) Close the valve to any uncapped discharge

or dump line 2) If pumper is operating as terminal unit

• Adjust the valve on the dump line To bring the residual pressure at the intake of pump to 50 psi

c) Probable cause 1) Attack pumper may be attempting to take

more water from the relay than it can supply

d) Possible corrective action 1) Notify water supply officer that relay is

unable to supply amount of water needed • Additional supply lines need to be put

into service 2) Reduce discharge pressure

• Until intake gauge registers a positive reading

B. While the relay is operating, the intake pressure increases above 50 psi 1. Symptom: Intake pressure gauge is reading above

50 psi and discharge pressure also increases accordingly a) Probable cause

1) Changes in flow of attack line cause friction loss to decrease and residual pressure to increase

b) Possible corrective action 1) No action is necessary unless pressure

increase becomes dangerous

RETIRED C

URRICULU

M

Page 275: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-6: Troubleshooting Pump Operations Page 25

2) Minor variations are to be expected 3) Frequent adjustments are undesirable

C. While the relay is operating, the intake pressure increases dangerously 1. Symptom: Intake pressure gauge is reading above

150 psi and discharge pressure is above 200 psi a) Probable cause

1) Hoselines have been shutdown with no corresponding dumping of excess water

b) Possible corrective action 1) Open uncapped discharge or dump line 2) Until intake residual pressure returns to

50 psi

RETIRED C

URRICULU

M

Page 276: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 26

SUMMARY: The driver/operator must be able to recognize and correct problems that may occur when pumping. Conditions that may affect pumping performance are cavitation, overheating, and inadequate water supply to name a few. EVALUATION: The student will complete the activity and written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 70-75 and Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 366-373 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 277: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 27

GROUP ACTIVITY 5-6-1

TITLE: What's Wrong!

TIME FRAME: 1:00

MATERIALS NEEDED: • Writing board/pad with markers/erasers

INTRODUCTION: This activity provides the students the opportunity to evaluate a problem associated to a pumping operation and identify one or more probable causes and possible corrective actions. The students cannot use the Pumping Apparatus Driver/Operator Handbook to complete this activity.

DIRECTIONS: 1. Divide the students into 5 groups (1-5). 2. In your group, develop a probable cause and possible

corrective action for each problem based on the symptom provided.

3. Record your responses on the writing board/pad. 4. You have 30 minutes to complete this activity. 5. Be prepared to discuss your answers with the class.

RETIRED C

URRICULU

M

Page 278: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 28

GROUP 1

OPERATION PROBLEM SYMPTOM

1 Common to all Unable to get a reading on the pressure gauge when the pump is put in service.

Green light indicating that the pump shift transfer is complete is not illuminated.

2 Common to all Pump will not develop sufficient pressure.

Indicator light shows that the relief valve is closed.

3 Common to all Pump is unable to supply its rated capacity.

Unable to develop enough engine rpm at full throttle to supply the rated capacity.

4 TANK While pumping, the discharge pressure drops to a very low value and water supply is interrupted.

Compound gauge on the intake reads "0" or fluctuates; engine speed increases.

5 DRAFT Pump will not prime. Electric motor will not operate to drive the primer.

6 DRAFT Pump loses its prime during the course of a pumping operation.

Pump loses its prime when it is operating near its maximum capacity. Vacuum reading on the intake gauge is near "0" and is fluctuating.

RETIRED C

URRICULU

M

Page 279: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 29

GROUP 2

OPERATION PROBLEM SYMPTOM

1 Common to all Unable to get a reading on the pressure gauge when the pump is put in service.

Green light is on, no mph reading registers on the speedometer.

2 Common to all Pump will not develop sufficient pressure.

Engine rpm cannot be raised to the value required as determined by the UL plate, even at full throttle. Tachometer reading is low; pressure gauge reading is too low.

3 Common to all Pump overheating while in operation.

Pump overheating warning light is on or by physical observation.

4 HYDRANT Suction line collapses when the discharge valve to a hoseline is opened.

Intake pressure drops to less than "0" and the discharge pressure also drops.

5 DRAFT Pump will not prime. Very little air is being discharged from the primer.

6 DRAFT Pump goes into cavitation when the flow increases.

Intake gauge registers more than 22 inches of vacuum; the pressure gauge fluctuates and decreases reading.

RETIRED C

URRICULU

M

Page 280: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 30

GROUP 3

OPERATION PROBLEM SYMPTOM

1 Common to all Unable to get a reading on the pressure gauge when the pump is put in service.

Speedometer reading is normal for pump operation. All indications are correct and rpm reading is as specified.

2 Common to all Pump is unable to supply its rated capacity.

The rpm reading on the tachometer is normal when compared to the UL plate.

3 Common to all Relief valve is inoperative or slow acting.

Pressure surges are excessive when individual hoselines are shutdown.

4 HYDRANT Suction line collapses when the discharge valve to a hoseline is opened.

Water coming out of the ground around the barrel of the hydrant.

5 DRAFT Pump loses its prime when the first discharge valve is opened and water begins to flow.

Discharge pressure gauge drops sharply.

6 RELAY Intake supply line collapses when the throttle setting is increased to establish the initial discharge pressure as required.

Intake pressure gauge reading is negative (reading vacuum instead of pressure).

RETIRED C

URRICULU

M

Page 281: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 31

GROUP 4

OPERATION PROBLEM SYMPTOM

1 Common to all Pump will not develop sufficient pressure.

The rpm reading on the tachometer is normal when compared with the UL plate.

2 Common to all Pump is unable to supply its rated capacity.

Intake gauge registers "0" or has a positive pressure indicated.

3 TANK

Unable to establish an adequate operating pressure or a loss of pressure occurs when the first discharge valve is opened.

Pressure increases with the engine rpm up to a point, then holds steady or fluctuates.

4 HYDRANT While supplying water, the suction line collapses and the pump begins to cavitate.

Intake pressure drops to less than "0" and discharge pressure fluctuates and decreases.

5 DRAFT Pump loses its prime when the first discharge valve is opened and water begins to flow.

Reading on the pressure gauge drops sharply and the intake gauge returns to the "0" reading.

6 RELAY While the relay is operating, the intake pressure increases above 50 psi.

Intake pressure gauge is reading above 50 psi and the discharge pressure also increases accordingly.

RETIRED C

URRICULU

M

Page 282: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-6: Troubleshooting Pump Operations Page 32

GROUP 5

OPERATION PROBLEM SYMPTOM

1 Common to all Pump will not develop sufficient pressure.

Relief valve is operating and the indicator light is on.

2 Common to all Pump is unable to supply its rated capacity.

Intake compound gauge is registering a high vacuum and the discharge pressure gauge is fluctuating (cavitation).

3 TANK Fluctuation of the pressure gauge and a reduction of discharge pressure when additional lines are put in service.

High vacuum reading on the intake compound gauge.

4 DRAFT Pump will not prime. Unable to get water into the pump through the hard suction hose. No vacuum reading is registered on the intake compound gauge.

5 DRAFT Pump loses its prime during the course of a pumping operation.

Pump loses its prime when all nozzles are closed and no water is flowing.

6 RELAY While the relay is operating, the intake pressure increases dangerously.

Intake pressure gauge is reading above 150 psi, the discharge pressure is above 200 psi.

RETIRED C

URRICULU

M

Page 283: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-7: Principles Of Tandem Pumping Operations Page 1

TOPIC: 5-7: Principles Of Tandem Pumping Operations

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1 and 5.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of principles of tandem pumping operations by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 115 and 584-585

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 115 and 584-585

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation. RETIRED C

URRICULU

M

Page 284: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-7: Principles Of Tandem Pumping Operations Page 2

SLIDE: 5-7-1 SLIDE: 5-7-2

I. TANDEM PUMPING PRINCIPLES A. Definition

1. A short relay operation in which a pumper taking water from the supply source (supply pumper) pumps into the intake of the second pumper (attack pumper)

SLIDE: 5-7-3 B. Purpose

1. Used when pressures higher than the capability of a single pump are required

2. Attack pumper boosts the pressure of the water even higher

What are some examples of when a higher water pressure is required?

a) Water required to supply 1) High-rise sprinklers 2) High-rise standpipes 3) Long hose lays

b) Attack pumper is close by 1) Supply pumper is placed directly on

hydrant and supports supply lines SLIDE: 5-7-4

II. TANDEM PUMPING PROCEDURES A. Supply pumper connects to hydrant

1. Using largest supply line B. Attack pumper positioned nearby

1. No further than 300 feet away RETIR

ED CURRIC

ULUM

Page 285: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-7: Principles Of Tandem Pumping Operations Page 3

C. Supply pumper connects line to attack pumper 1. Supply pumper discharge line to intake of attach

pumper SLIDE: 5-7-5

2. Attack pumper is able to discharge water at a much higher pressure than a single engine could have supplied

3. Pumps are operating in series

RETIRED C

URRICULU

M

Page 286: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-7: Principles Of Tandem Pumping Operations Page 4

SUMMARY: At most incidents where pump operations are used, a single engine is able to achieve the necessary pressure required for mitigation. Yet, when the unique situation occurs where greater water pressure is required than the responding pumper can supply, a tandem pumping operation must be immediately implemented. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 115 and 584-585 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 287: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-8: Principles Of Dual Pumping Operations Page 1

TOPIC: 5-8: Principles Of Dual Pumping Operations

TIME FRAME: 0:15

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.1 and 5.2.2

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of principles of dual pumping operations by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 113-115 and 575

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 113-115 and 575

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 288: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-8: Principles Of Dual Pumping Operations Page 2

SLIDE: 5-8-1 SLIDE: 5-8-2

I. DUAL PUMPING PRINCIPLES A. Definition

1. An operation where a large volume hydrant is used to supply two pumpers by connecting the pumpers intake-to-intake

2. A second pumper receives the excess water not being pumped by the first pumper, which is directly connected to the water supply source

SLIDE: 5-8-3 B. Purpose

1. To provide adequate water supply and pressure a) May supply more than one pumper

What are the advantages of dual pumping operations? SLIDE: 5-8-4

C. Advantages 1. Efficient water use 2. Shorter hose lays 3. Rapid deployment of additional hoselines 4. Apparatus may be grouped together

SLIDE: 5-8-5 D. Dual pumping procedures

1. First pumper connects to hydrant a) Using largest supply line

2. Second pumper position a) Intake-to-intake with first pumper b) Dual pumping may be put into operation while

first pumper is actively flowing water

RETIRED C

URRICULU

M

Page 289: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-8: Principles Of Dual Pumping Operations Page 3

SLIDE: 5-8-6 3. Fire hydrant

a) Closed until the intake gauge of first pumper reads 0 to 5 psi 1) The throttle of first engine will need

adjustment b) When volume of discharge and intake become

equal 1) Cap of the unused intake may now be

removed SLIDE: 5-8-7

c) First pumper 1) Equipped with a keystone or gate valve on

its unused intake

• Gate valve can be used to restrict flow d) Second pumper

1) Connected by intake hose to the unused large intake of first pumper

2) Fire hydrant opened completely 3) Pumps water to desired hoselines

SLIDE: 5-8-8 4) Water supply of second pumper is the

water that is not being used by the first pumper, as it passes through the pump of the first pumper

RETIRED C

URRICULU

M

Page 290: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-8: Principles Of Dual Pumping Operations Page 4

SUMMARY: As the driver/operator responsible for supplying water and a given emergency, it is imperative that you know your local water capabilities and unique hydrant characteristics. Armed with this knowledge, you should be able to immediately recognize and implement a dual pumping operation appropriately. The ease and efficiency of a proper dual pumping operation will significantly improve the overall mitigation by maximizing the available resources. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 113-115 and 575 in order to prepare yourself for the upcoming test Study for our next session.

RETIRED C

URRICULU

M

Page 291: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-9: Principles And Practices Of Foam Operations Page 1

TOPIC: 5-9: Principles And Practices Of Foam Operations

TIME FRAME: 1:00

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Sections 5.2.3 and 8.2.3

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of principles and practices of foam operations by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 451-480

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 451-480

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 292: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 2

SLIDE: 5-9-1 SLIDE: 5-9-2

I. FOAM FIRE STREAMS A. Initially used for industrial and airport fire protection

1. Now a part of municipal fire departments 2. Due to the magnitude and frequency of hazardous

materials incidents requiring foam for their control B. Types of foam

How many basic types of foam are there?

1. There are two basic types of foam a) Chemical

1) Produced as a result of a reaction between two chemicals

2) Considered obsolete and are rarely, if ever, found in use today.

b) Mechanical 1) Mechanical foams must be proportioned,

mixed with water and aerated (mixed with air) before they can be used

2) To produce quality fire fighting foam, foam concentrate, water, air, and mechanical aeration are needed

• Must be present and blended in the correct ratios

SLIDE: 5-9-3 C. Foam components

1. Foam concentrate a) Raw foam liquid as it rests in its storage

container before the introduction of water and air

b) Should match the fuel to which they are applied

RETIRED C

URRICULU

M

Page 293: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 3

2. Foam proportioner a) The device that introduces foam concentrate

into the water stream to make the foam solution

3. Foam solution a) The mixture of foam concentrate and water

before the introduction of air 4. Foam

a) The completed product after air is introduced into the foam solution (also known as finished foam)

b) Aeration should produce an adequate amount of bubbles to form an effective foam blanket

II. FOAM CONCENTRATES A. Class A

Class A foams are designed for what types of materials? SLIDE: 5-9-4

1. Designed for normal combustible materials a) Class A foam is the formulation of specialty

hydrocarbon surfactants b) Reduces surface tension of the water in the

foam solution 2. Biodegradable

a) May harm wildlife b) Especially near bodies of water

3. These foams are corrosive 4. Have super cleaning ability

a) Little adverse effect on equipment due to the low percentages used

b) Equipment should be thoroughly flushed

RETIRED C

URRICULU

M

Page 294: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 4

5. Class A foams are used a) Where maximum absorption is needed b) On vertical surfaces c) Or when a combination of both are needed

B. Class B What types of fuels are Class B foams used for? SLIDE: 5-9-5

1. For flammable liquids 2. There are two types of classifications for Class B

fuels - hydrocarbon and polar solvents a) Hydrocarbon fuels

1) Examples

• Crude oil

• Fuel oil

• Gasoline

• Benzene

• Naphtha

• Jet fuel

• Kerosene, etc. 2) Hydrocarbons are petroleum based and

float on water 3) Standard fire fighting foam floats on the

surface of hydrocarbon fuels b) Polar solvent fuels

1) Liquids that are miscible in water or fuels that absorb water

2) Examples

• Alcohol

• Acetone

• Lacquer

RETIRED C

URRICULU

M

Page 295: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 5

• Thinner

• Ketones

• Esters

• Gasoline that contains 10% or more alcohol

c) Improper matching of the proper foam concentrate with the fuel will result in an unsuccessful extinguishing attempt

d) Could endanger fire fighters 3. Types of Class B foam concentrates

SLIDE: 5-9-6 a) Regular protein foams

1) Derived from naturally occurring sources of protein

What are some examples of protein sources used to make protein foams?

2) Examples - hoof, horn, or feather meal 3) Rarely used in the fire service today. 4) Very good heat stability and resists burn

back 5) Not as mobile or fluid on the fuel surface

as other types of low-expansion SLIDE: 5-9-7

b) Fluoroprotein foam is a combination protein-based and synthetic-based foam 1) Derived from protein 2) Has fluorochemical surfactants similar to

those for AFFF 3) Provides a strong "security blanket" for

long-term vapor suppression 4) Can be formulated to be alcohol resistant

by adding ammonia

RETIRED C

URRICULU

M

Page 296: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 6

SLIDE: 5-9-8 c) Aqueous film forming foam (AFFF)

1) Nearly completely synthetic 2) Has an air-/vapor-excluding film that is

released ahead of the foam blanket 3) The fast-moving foam blanket then moves

across the surface and around objects • Adding further insulation

4) As the aerated foam blanket continues to drain its water, more film is released

What ability or quality does AFFF have?

• Giving it the ability to "heal" over areas where the foam blanket is disturbed

5) Alcohol-resistant AFFFs are available from most foam manufacturers

• For polar solvent fuels SLIDE: 5-9-9

d) Film forming fluoroprotein foam (FFFP) 1) Fluoroprotein foam with aqueous film-

forming foam (AFFF) capabilities SLIDE: 5-9-10

e) High-expansion foams 1) Special-purpose foams 2) Detergent based 3) They have a low water content

• Minimizes water damage 4) Used in concealed spaces

• Such as basements, in coal mines, and in other subterranean spaces

5) Used in fixed-extinguishing systems for specific industrial uses

• Such as rolled or bulk paper storage

RETIRED C

URRICULU

M

Page 297: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 7

SLIDE: 5-9-11 III. HOW FOAM WORKS

A. Separating 1. Creates a barrier between the fuel and the fire

B. Cooling 1. Lowers the temperature of the fuel and adjacent

surfaces C. Suppressing

What does suppressing do?

1. Prevents the release of flammable vapors SLIDE: 5-9-12

IV. PROPORTIONING A. Class A

1. Normally mixed at ratios of 0.2% to 1% 2. Manufacturer specific

a) Can be mixed at a higher ratio for a thick blanket 1) For exposure protection and fire breaks 2) Can be mixed at a lower ratio

• To allow foam to sink into fuels B. Class B

What proportioning ratios are used for hydrocarbon fuels?

1. Mixed at 1-3% for hydrocarbons 2. Mixed at 3-6% for polar solvents

SLIDE: 5-9-13 C. Methods of proportioning

1. Induction (eduction) a) Uses the pressure energy in the stream of

water to induct (draft) foam concentrate into the fire stream

RETIRED C

URRICULU

M

Page 298: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 8

2. Injection a) The use of an external pump or head pressure

to force foam concentrate into the fire stream at the correct ratio

SLIDE: 5-9-14 3. Batch mixing

a) An appropriate amount of foam concentrate is poured directly into a tank of water

b) The most simple method 4. Premixing

a) Premeasured portions of water and foam concentrate are mixed in a container

V. PROPORTIONING EQUIPMENT A. Portable low energy systems

SLIDE: 5-9-15 1. In-line eductors

a) Most common b) Works off of the Venturi principle

1) Flow of water through the eductor creates a vacuum near the outlet side of the eductor

• Over a reduced opening in the eductor 2) This vacuum drafts solution into the water

stream through a pick-up tube connected to the eductor

SLIDE: 5-9-16 c) Operational rules

1) Eductor must control flow through the system

What should the pressure be at the eductor outlet?

2) Pressure at the eductor outlet must not exceed 65-70% of eductor inlet pressure

RETIRED C

URRICULU

M

Page 299: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 9

3) Foam concentration is only correct at rated eductor inlet pressures

• Using lower than rated pressures results in a concentration that is too rich

SLIDE: 5-9-17 4) Eductors must be thoroughly flushed after

each use 5) Metering valves must be set to match foam

concentrate and burning fuel 6) Foam concentrate inlet to the eductor must

not be more than 6 feet above the surface of the foam concentrate

SLIDE: 5-9-18 2. Foam nozzle eductors

a) Operates on the same principles as the in-line eductor

b) A major disadvantage is that the foam concentrate must be located near the nozzle 1) Cannot be moved quickly

SLIDE: 5-9-19 3. Self-educting master stream foam nozzles

When are these used? a) Used for flows in excess of 350 gpm b) Designed to operate at lower pressures c) May be used with a jet ratio controller

1) Allows concentrate supply to be up to 3,000 feet away

2) Also allows for changes in elevation up to 50 feet

SLIDE: 5-9-20 B. Apparatus-mounted low energy systems

1. The majority of these systems can be used for Class A and Class B concentrates

RETIRED C

URRICULU

M

Page 300: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 10

SLIDE: 5-9-21 2. Installed in-line eductors

a) Operate on the same principles as the portable in-line eductor

b) Can be supplied by pick-up tubes out of 5-gallon buckets or by on-board foam tanks

SLIDE: 5-9-22 3. Around-the-pump proportioners

a) One of the most common types of built-in proportioners installed in mobile fire apparatus today

b) Consists of a small return (bypass) water line connected from the discharge side of the pump back to the intake side of the pump

c) An in-line eductor is positioned on this bypass line

SLIDE: 5-9-23 d) A valve just off the discharge controls the flow

of water through the bypass line e) When the valve is open, a small amount of

water (10-40 gpm) discharged from the pump is directed through the bypass piping

f) Water passing through the eductor draws concentrate into the bypass piping

SLIDE: 5-9-24 g) The resulting foam solution is then supplied

back to the intake side of the pump h) It is then pumped to the discharge and into the

hoseline What is a major disadvantage with these proportioners? SLIDE: 5-9-25

RETIRED C

URRICULU

M

Page 301: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 11

i) A major disadvantage of older types is that it cannot take advantage of incoming pressure 1) Inlet pressures greater than 10 psi will

prevent concentrate from entering the intake

2) This can only be used when operating from the apparatus water tank

3) Newer units can handle inlet pressures up to 40 psi

SLIDE: 5-9-26 4. Bypass-type balanced pressure proportioners

a) There is a foam concentrate line connected to each fire pump discharge outlet

b) System is designed to supply foam concentrate to the outlet at the same pressure at which the fire pump is supplying water to that discharge 1) By PTO or other power source

SLIDE: 5-9-27 c) The pump discharge are jointly monitored by a

hydraulic pressure control valve 1) It ensures that the concentrate pressure

and water pressure are balanced d) The concentrate supplied is delivered by size

of stream, relating to the overall discharge outlet size 1) In other words a 3% foam would have a

concentrate stream that was 3% of the entire discharge stream

2) This works because the concentrate is delivered at the same pressure as water

• More accurate SLIDE: 5-9-28

e) Its primary advantage is that it can monitor demand and adjust accordingly

RETIRED C

URRICULU

M

Page 302: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 12

f) A disadvantage may be that it can cause agitation of the stream

SLIDE: 5-9-29 5. Variable-flow variable-rate direct injection systems

a) This system injects concentrate directly into the water stream

How is the concentrate amount determined?

1) Using an electrically or hydraulically powered positive displacement pump

b) Amount delivered into the stream is based on flow, not pressure 1) Flow is monitored and the speed of the

positive displacement pump is regulated SLIDE: 5-9-30

c) Its primary advantage is that it can accurately adjust to changes within its design limits 1) It can also be used with high energy foam

systems d) A disadvantage is that it must be installed

within the piping before any discharge manifolds

SLIDE: 5-9-31 6. Variable-flow demand-type balanced pressure

proportioners a) Basically a Venturi-type system within the

water line b) Advantages

1) Concentrate flow and pressure match demand

2) Does not recirculate the concentrate back to the foam tank(s)

3) Does not require flushing after use

RETIRED C

URRICULU

M

Page 303: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 13

SLIDE: 5-9-32 c) Disadvantages

1) There are discharge ratio controllers that reduce discharge area

2) Pressure drops across discharges are greater than on regular pumps

SLIDE: 5-9-33 7. Batch mixing

a) Simplest means b) Amount mixed is based on tank size

What is a disadvantage to batch mixing?

c) Disadvantages 1) Contaminates the water tank and pump

• Thorough flushing is required 2) Does not allow for continuous operation

SLIDE: 5-9-34 C. High energy foam systems – compressed air foam

systems 1. Compressed air is introduced into the foam solution

prior to discharge into the hoseline a) Generated by the use of a direct-injection

proportioning system and a standard centrifugal pump coupled with 1) An air compressor

or 2) Stored air

2. Turbulence of air and solution in the pipe/hoseline creates a finished foam a) Also allows foam to be discharged at greater

distances than regular foams 3. Used with Class A foams

RETIRED C

URRICULU

M

Page 304: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 14

What are some advantages to compressed air foam systems? SLIDE: 5-9-35

4. Advantages a) Greater reach b) Uniform, durable bubbles c) Adheres to surfaces d) Hoselines are lighter

5. Disadvantages a) Expensive b) Hose reaction can be erratic

1) Especially with a hose rupture c) Additional training is necessary

SLIDE: 5-9-36 D. Foam application devices

1. Handline nozzles a) Solid bore b) Fog c) Air-aspirating

1) Introduces air by Venturi effect 2. Master stream foam nozzles 3. Medium and high-expansion foam generating

devices What applications are associated with medium and high-expansion foams?

a) Often associated with total flooding applications

RETIRED C

URRICULU

M

Page 305: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 15

SLIDE: 5-9-37 E. Foam storage

1. Pails 2. Barrels 3. Apparatus tanks

a) On fire apparatus equipped with integral, onboard foam proportioning systems

SLIDE: 5-9-38 F. Expansion ratios

1. Low expansion a) Up to 50:1

2. Medium expansion a) 50:1 to 300:1

3. High expansion a) 300:1 to around 1250:1

VI. OPERATIONAL TROUBLESHOOTING SLIDE: 5-9-39

A. Symptom: Failure to generate foam or generating poor quality foam

What is one reason for this?

1. Possible cause a) Failure to match eductor and nozzle flow

1) No foam is in the pick-up tube 2. Possible corrective action

a) Check manufacturer's recommendations and specifications for eductor and nozzle

SLIDE: 5-9-40 3. Possible cause

a) Air leaks at fittings that cause loss of suction

RETIRED C

URRICULU

M

Page 306: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 16

4. Possible corrective action a) Inspect and tighten all fittings b) Remove defective components from operation

1) Damaged hose 2) Broken nozzle, etc.

SLIDE: 5-9-41 5. Possible cause

a) Dirty or clogged foam passages from improper cleaning

6. Possible corrective action a) Clean all proportioning equipment components

after each use SLIDE: 5-9-42

7. Possible cause a) Partially closed nozzle control that results in a

higher nozzle pressure 8. Possible corrective action

a) Open nozzle control completely SLIDE: 5-9-43

9. Possible cause a) Too long a hose lay on the discharge side of

the eductor 10. Possible corrective action

a) Reduce hose lay to recommended length SLIDE: 5-9-44

11. Possible cause a) Kinked hose

12. Possible corrective action a) Unkink hose

SLIDE: 5-9-45

RETIRED C

URRICULU

M

Page 307: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-9: Principles And Practices Of Foam Operations Page 17

13. Possible cause a) Nozzle too far above eductor causing

excessive elevation pressure 14. Possible corrective action

a) Lower nozzle b) Reposition hose configuration

SLIDE: 5-9-46 15. Possible cause

a) Mixing different types of foam concentrates 1) Mixture becomes too viscous to pass

through the eductor 16. Possible corrective action

a) Use foam only as recommended

RETIRED C

URRICULU

M

Page 308: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-9: Principles And Practices Of Foam Operations Page 18

SUMMARY: Successful foam operations are not "ready-made." They involve not only product and equipment familiarity, but also application in various settings. In other words, the driver/operator not only needs a good knowledge base, but practical reasoning and training. Foam operations should be tested and practiced in order to be successful. There are too many required elements to leave it up to chance. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 451-480 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 309: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-10: Sprinkler And Standpipe Support Page 1

TOPIC: 5-10: Sprinkler And Standpipe Support

TIME FRAME: 0:30

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2.4

BEHAVIORAL OBJECTIVE:

Condition: Given a written test

Behavior: The student will confirm a knowledge of sprinkler and standpipe support by completing the written test

Standard: With a minimum 80% accuracy according to the information contained in Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 347-348

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials

REFERENCES: • Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 347-348

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 310: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-10: Sprinkler And Standpipe Support Page 2

SLIDE: 5-10-1 SLIDE: 5-10-2

I. SUPPORTING AUTOMATIC SPRINKLERS A. Water supplies for sprinkler systems are designed to

supply only part of the total number of sprinklers installed on the system 1. In the event of a large fire, the sprinkler system will

need an outside source of water and pressure to be effective

B. Pre-incident plans should identify all occupancies in the community that have automatic sprinkler systems

What information should be included in pre-fire plans concerning sprinkler systems?

1. Information that should be included a) Location(s) of the fire department

connection(s) or FDC b) Hydrant or water supply source(s)

1) Closest may not always be the best choice c) Any special requirements for pump pressure

required to supply the system d) Location and familiarization of system pumps if

equipped with such SLIDE: 5-10-3

C. Connections 1. A siamese with at least two 2½" female

connections, or 2. One large diameter sexless connection that is

connected to a clappered inlet D. Upon arrival at a sprinklered property, preparations

should be immediately made to supply the FDC 1. The location of the FDC and the nearest suitable

hydrant should be identified by the first-arriving or other first-alarm engine company

RETIRED C

URRICULU

M

Page 311: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-10: Sprinkler And Standpipe Support Page 3

SLIDE: 5-10-4 2. If there is any indication of an actual fire, such as

smoke or the ringing of a sprinkler alarm a) A minimum of two 2½" hoselines or one 3"

hoseline should be connected to the FDC 1) Look for debris or obstruction in the FDC

b) Supply lines should be laid to the hydrant and all appropriate connections made

c) A determination should be made as soon as possible whether or not the sprinkler system is to be charged

SLIDE: 5-10-5 d) Pressure to the system should be developed

slowly 1) Follow department policies

What position should the pump transfer valve be in during sprinkler operations?

e) Multistage pumps should be in the VOLUME (parallel) position

f) Pressure (supply from pumper) 1) As a rule of thumb PDP is 150 psi at the

FDC 2) Buildings with their own fire pumps may

have an operational pressure greater than 150 psi

g) When possible, the accessible control valves should be checked and opened if necessary 1) Except in the case where it is known that

the building or area has been undergoing construction or renovation affecting the sprinklers

RETIRED C

URRICULU

M

Page 312: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-10: Sprinkler And Standpipe Support Page 4

h) The fire pump on the property should be checked to ensure that the pump is running 1) Control valves are frequently located in the

pump room so that both functions can be performed

SLIDE: 5-10-6 II. SUPPORTING STANDPIPE SYSTEMS

A. Standpipes are used to speed fire attack in multistory or single-story buildings with large floor areas 1. Connections are 2½" and 1½" 2. Standpipes may be wet or dry, depending upon

owner preference or local code requirements B. Standpipe FDCs should be clearly identified to prevent

confusion between sprinkler and standpipe connections What types of hose lays should be used for standpipe operations?

1. The hose lays previously described for sprinkler system FDCs apply here as well

C. Planned pump discharge pressures or rules of thumb for each building equipped with a standpipe should be developed 1. Pump discharge pressures in excess of 200 psi are

not encouraged unless the standpipe system has been designed to withstand higher pressures

2. If the standpipe system is equipped with pressure-reducing valves, elevation pressure must be based on the total height of the standpipe or the zone being used a) Pressure-reducing valves reduce whatever

pressure is presented to it b) If pressure is less than the valve adjustment,

the result will be inadequate pressure for the hoselines

RETIRED C

URRICULU

M

Page 313: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 5-10: Sprinkler And Standpipe Support Page 5

SLIDE: 5-10-7 D. Hose valves in dry standpipes may be open for various

reason 1. When charged, water will be discharged on levels

below the fire floor 2. The valves must be closed

E. When dry standpipes are charged, there is a time delay before water arrives to the hose valve 1. Air is expelled from the system when flowing 2. Air can also be trapped and become compressed

a) May exit under high pressure when valve is opened

b) Open valves slowly

RETIRED C

URRICULU

M

Page 314: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 5-10: Sprinkler And Standpipe Support Page 6

SUMMARY: Sprinkler systems and standpipes are tools that enhance fire safety. Nearly every jurisdiction has one or both. Pre-incident planning and preparation are essential to gaining full advantage afforded by these fire safety operations. EVALUATION: The student will complete the written test at a time determined by the instructor. ASSIGNMENT: Review your notes and read Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 347-348 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 315: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 1

TOPIC: 6-1: Introduction To The Pumping Exercises

TIME FRAME: 0:30 (Introduction only)

LEVEL OF INSTRUCTION: Level II

AUTHORITY: 2009 NFPA 1002: Section 5.2

BEHAVIORAL OBJECTIVE:

Condition: Given an activity

Behavior: The student will demonstrate the ability to produce an effective fire stream by completing the pumping exercises

Standard: With a minimum 80% accuracy according to the information contained in Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 80-91

MATERIALS NEEDED: • Writing board/pad with markers/erasers • Appropriate audiovisual equipment • Appropriate audiovisual materials • Pumping Exercise 6-1-1: Operating From Draft • Pumping Exercise 6-1-2: Operating Using a Forward Lay • Pumping Exercise 6-1-3: Operating Using a Reverse Lay

REFERENCES: • Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 80-91

• NFPA 1002: Standard for Fire Apparatus Driver/Operator Professional Qualifications, 1009 Edition, Section 5.2

Each instructor must develop a motivational statement on why the student should learn the upcoming material. The purpose is to establish relevancy of the lesson to the audience. The ACID BASE acronym can be used to help develop student motivation.

Attention (attract) Begin Curiosity (arouse) Association Interest (create) Students Desire (stimulate) Experience

PREPARATION:

Cite examples or use related illustrations of near-miss incidents, injuries, or fatalities. Write this section "from the heart." Be creative! Have fun with it or be serious, but remember the goal is to stimulate student motivation.

RETIRED C

URRICULU

M

Page 316: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 2

SLIDE: 6-1-1 SLIDE: 6-1-2

I. PUMPING EXERCISES A. Designed to assist the driver/operator in becoming

familiar with operating the pump controls using different sources of water

B. Types of exercises 1. Operating from draft 2. Operating using a forward lay 3. Operating using a reverse lay

SLIDE: 6-1-3 II. OPERATING FROM DRAFT

SLIDE: 6-1-4 A. Overview

1. Using a static water source as a supply 2. Correctly solving hydraulics problem 3. Operating pump controls safely 4. Maintaining an effective fire stream

B. Exercise setup 1. Apparatus parked and chocked next to drafting

source a) Parking brake set b) Main engine shut-off

2. Tank-to-pump valve is open 3. Tank fill valve is closed 4. Water tank and pump are empty 5. Hoseline not attached, but laid out with female end

near apparatus a) Can be directed back into the drafting source

6. Hard suction hose not attached, but placed near the apparatus

RETIRED C

URRICULU

M

Page 317: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 3

7. If using a multi-stage pump, the transfer valve will be set to the volume setting

C. Apparatus operation 1. Make proper hose connections 2. Develop and maintain draft 3. Establish and maintain fire stream 4. Set relief valve 5. Safely shutdown all lines and disengage pump 6. Interpret gauge readings 7. Using the step-by-step procedure on score sheet

D. Scoring criteria 1. 120 points possible 2. Time allotted to complete exercise

a) 10:00 3. Points deducted for each step not completed

a) Some critical steps have an asterisk (*) must be completed

4. Passing score is 80% 5. Automatic failure

a) Omitted a critical step 1) Marked with an asterisk (*)

b) Exceeded the allotted time c) Acted in a manner resulting in any personal

injury d) Failed to engage the pump e) Abused the apparatus

SLIDE: 6-1-5 SLIDE: 6-1-6 SLIDE: 6-1-7

RETIRED C

URRICULU

M

Page 318: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 4

III. OPERATING USING A FORWARD LAY SLIDE: 6-1-8

A. Overview 1. Using tank water for first hoseline, then changing

over to a pressurized water source and flowing a second hoseline

2. Correctly solving hydraulics problem 3. Operating pump controls safely 4. Maintaining effective fire stream

B. Exercise setup 1. Apparatus parked at simulated fire incident 2. Tank-to-pump valve is open 3. Tank fill valve is closed 4. Supply line laid out on the ground is connected to

hydrant discharge and hose bed 5. Two (2) hoselines of different sizes are laid out on

the ground and connected to apparatus C. Apparatus operation

1. Solve hydraulics problem for first hoseline a) Charge first hoseline

2. Set relief valve 3. Connect supply line to intake 4. Perform changeover from tank to hydrant 5. Solve hydraulics problem for second hoseline

a) Charge second hoseline 6. Determine additional line availability 7. Safely shutdown all lines and disengage pump 8. Using the step-by-step procedure on score sheet

D. Scoring criteria 1. 150 points possible 2. Time allotted to complete exercise

a) 10:00

RETIRED C

URRICULU

M

Page 319: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 5

3. Points deducted for each step not completed a) Some critical steps have an asterisk (*) must

be completed 4. Passing score is 80% 5. Automatic failure

a) Omitted a critical step 1) Marked with an asterisk (*)

b) Exceeded the allotted time c) Acted in a manner resulting in any personal

injury d) Failed to engage the pump e) Ran the pump dry (without water) f) Abused the apparatus

SLIDE: 6-1-9 SLIDE: 6-1-10 SLIDE: 6-1-11

IV. OPERATING USING A REVERSE LAY SLIDE: 6-1-12

A. Overview 1. With an appliance at the incident, drive apparatus

to the water source 2. Correctly solve the hydraulics problem 3. Operate pump controls safely 4. Maintain effective fire stream

B. Exercise setup 1. Monitor setup at simulated fire incident

a) 500 gpm minimum 2. Tank-to-pump valve is open 3. Tank fill valve is closed 4. Hoselines connected to monitor and laid back to

hydrant

RETIRED C

URRICULU

M

Page 320: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 6

C. Apparatus operation 1. Drive apparatus and spot at hydrant 2. Connect hoselines from monitor to apparatus 3. Connect supply hose to hydrant 4. Solve hydraulics problem

a) Charge hoselines 5. Set relief valve 6. Safely shutdown all lines and disengage pump 7. Using the step-by-step procedure on score sheet

D. Scoring criteria 1. 150 points possible 2. Time allotted to complete exercise

a) 5:00 3. Points deducted for each step not completed

a) Some critical steps have an asterisk (*) must be completed

4. Passing score is 80% 5. Automatic failure

a) Omitted a critical step 1) Marked with an asterisk (*)

b) Exceeded the allotted time c) Acted in a manner resulting in any personal

injury d) Failed to engage the pump e) Ran the pump dry (without water) f) Abused the apparatus

SLIDE: 6-1-13 SLIDE: 6-1-14 SLIDE: 6-1-15

RETIRED C

URRICULU

M

Page 321: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

PRESENTATION APPLICATION

October 2008 6-1: Introduction To The Pumping Exercises Page 7

V. SAFETY CONSIDERATIONS A. Check apparatus before operating B. Check surface conditions C. Wear appropriate PPE D. Review and follow all instructions E. Operate apparatus with due regard F. Use spotters for safety G. Check apparatus after exercise

RETIRED C

URRICULU

M

Page 322: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 8

SUMMARY: Being able to produce and maintain an effective, continuous fire stream is a simple operation if you choose the best procedure to accomplish our goals. You must be capable of modifying your pumping plan as incident conditions change. You must also be aware of how your apparatus is performing and how much more is available without exceeding safe limits. EVALUATION: The student will complete the pumping exercises at a time determined by the instructor. ASSIGNMENT: Review your notes and read Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Pages 80-91 in order to prepare yourself for the upcoming test. Study for our next session.

RETIRED C

URRICULU

M

Page 323: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 9

PUMPING EXERCISE 6-1-1

EXERCISE: Operating From Draft

This exercise allows the driver/operator to become familiar with using a static water source as a supply while operating the pump controls safely and maintaining an effective fire stream. Fire hydrants are not always available at the scene, and the driver/operator may have to use some imagination to determine an alternate water supply. Solving a hydraulics problem is required.

TIME FRAME: 10:00 (per student)

AUTHORITY: 2009 NFPA 1002: Section 5.2

MATERIALS NEEDED: • Fire apparatus • 2,400 square foot area (30' x 80') • Drafting source • Stopwatch • 1½" or 1¾" hoseline • Hard suction hose • Student assistant

INSTRUCTOR DIRECTIONS:

1. Demonstrate and explain each step of the exercise. 2. Students should determine hydraulic formula solutions

using field hydraulics for the hoseline and nozzle being used.

3. Provide adequate space and supervision to perform the exercise safely and without risk of injury.

STUDENT DIRECTIONS: 1. Make the proper hose connections. 2. Develop and maintain draft. 3. Establish and maintain a fire stream. 4. Solve the hydraulics problem(s). 5. Set the relief valve. 6. Safely shutdown all lines and disengage the pump. 7. Continually interpret gauge readings throughout the

exercise and recall those readings to the instructor. 8. Step-by-step procedures are listed on the Scoring Sheet.

RETIRED C

URRICULU

M

Page 324: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 10

EXERCISE: Operating From Draft

SCORING: 120 points possible 80% passing

1. Points are deducted for each step not completed. 2. The student fails if a step marked with an asterisk (*) is

omitted. 3. The student fails if the exercise is not completed within the

allotted time. 4. The student fails if any personal injury occurs. 5. The student fails if he or she does not engage the pump. 6. The student fails there is apparatus abuse.

SITE PREPARATION: • Apparatus is properly parked and chocked next to the drafting source.

• Parking brake is set. • Main engine is shutoff. • Tank-to-pump valve is open. • Tank fill valve is closed. • Water tank and pump in the apparatus are empty. • Hoseline is laid out on the ground with the female end near

the apparatus. This line can be directed back into the drafting source.

• Hard suction hose is placed near apparatus, but is not attached.

• If using a multi-stage pump, the transfer valve will be set to the volume setting.

RETIRED C

URRICULU

M

Page 325: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 11

PUMPING EXERCISE 6-1-1 SCORING SHEET

STUDENT: DATE:

6-1-1: OPERATING FROM DRAFT Penalty points subtracted from 100 possible points. Rated Component Value 120

1. Start engine prior to leaving cab 5

TIME STARTS (When student's foot touches the ground)

2. Connect hard suction hose to apparatus and place in drafting source 5

3. Connect hoseline to designated discharge 5

4. Close all valves and drains 5

5. Engage midship pump *

6. Throttle engine up to 1000 – 1200 rpm 5

7. Engage primer for no more than 30 – 45 seconds or until water has filled hard suction hose 5

8. Operate pump panel throttle slowly until the PDP reads 100 psi (If prime is lost, repeat step 6) 10

9. Loudly state, "Water coming" 10

10. Slowly open designated discharge valve 5

11. Calculate field hydraulics for the hoseline and nozzle being used 10

12. Readjust the pump panel throttle slowing until the proper PDP is reached (+ 5 psi) 10

13. Properly adjust the pressure relief valve 10

TIME STOPS

14. The student must recall and interpret the gauge readings 5

SHUTDOWN PROCEDURES

1. Loudly state, "Shutdown" 5

2. Slowly close discharge valve 2

3. Slowly reduce pump panel throttle until main engine returns to idle 2

4. Return to cab and disengage pump 2

5. Shut-off main engine 2

6. Open tank-to-pump valve and drain pump 2

7. Disconnect hoseline and hard suction hose 2 RETIRED C

URRICULU

M

Page 326: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 12

MISCELLANEOUS

1. Dropped a brass coupling 2

2. Opened valves too fast 2

3. Left compartment door open 2

4. Failed to remove kinks in hose(s) 2

5. Failed to disengaging the pump 5

ITEMS THAT WILL RESULT IN AUTOMATIC FAILURE 1. Omitted a step marked with an asterisk (*) Yes Failure 2. Exceeded the allotted time Yes Failure 3. Acted in a manner resulting in any personal injury Yes Failure 4. Failed to engage the pump Yes Failure 5. Abused the apparatus Yes Failure

ALLOTTED TIME: 10:00 MINUTES TOTAL POINTS: COMPLETION TIME: PASSING SCORE: 96

Scorer's Name:

Signature:

PASS/FAIL: Pass Fail Retest

6-1-1 NOTES:

RETIRED C

URRICULU

M

Page 327: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 13

PUMPING EXERCISE 6-1-2

EXERCISE: Operating Using A Forward Lay

This exercise will allow the driver/operator to become proficient at using tank water with the first attack line; then changing over to a pressurized water source and flowing a second attack line. Solving a hydraulics problem is required.

TIME FRAME: 10:00 (per student)

AUTHORITY: 2009 NFPA 1002: Section 5.2

MATERIALS NEEDED: • Fire apparatus • 10,000 square foot area (50' x 200') • Hydrant • Stopwatch • 100-foot supply hose (minimum) • 150-foot length of 1½" or 1¾" discharge hoseline • 150-foot length of 2½" discharge hoseline • Student assistant

INSTRUCTOR DIRECTIONS:

1. Demonstrate and explain each step of the exercise. 2. The hoselines can be attached to a stable object or held

by other students. 3. Hydraulics formula solutions are determined by: 1½" hoseline flowing 100 gpm (136 psi) or

1¾" hoseline flowing 150 gpm (134 psi) 2½" hoseline flowing 250 gpm (119 psi)

Use the same formulas taught in the class. 4. Provide adequate space and supervision to perform the

exercise safely and without risk of injury.

STUDENT DIRECTIONS: 1. Break supply line form hose bed and connect to inlet suction.

2. Solve the hydraulic problem for the first hoseline, then charge.

3. Set the relief valve. 4. Perform changeover from tank to hydrant.

RETIRED C

URRICULU

M

Page 328: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 14

EXERCISE: Operating Using A Forward Lay

5. Solve hydraulic problem for the second hoseline, then charge.

6. Safely shutdown all lines and disengage the pump. 7. Continually interpret gauge readings throughout the

exercise and recall those readings to the instructor. 8. Step-by-step procedures are listed on the Scoring Sheet.

SCORING: 120 points possible 80% passing

1. Points are deducted for each step not completed. 2. The student fails if a step marked with an asterisk (*) is

omitted. 3. The student fails if the exercise is not completed within

the allotted time. 4. The student fails if any personal injury occurs. 5. The student fails if he or she does not engage the pump. 6. The student fails if the pump is run dry. 7. The student fails there is apparatus abuse.

SITE PREPARATION: • Apparatus is parked at a simulated fire incident. • Tank-to-pump valve is open. • Tank fill valve is closed. • Supply line laid out on the ground and connected to

hydrant discharge and hose bed. • Two (2) hoselines of different sizes are laid out on the

ground and connected to the apparatus.

RETIRED C

URRICULU

M

Page 329: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 15

PUMPING EXERCISE 6-1-2 SCORING SHEET

STUDENT: DATE:

6-1-2: OPERATING USING A FORWARD LAY Penalty points subtracted from 150 possible points. Rated Component Value 150

1. Start engine and engage midship pump 5 TIME STARTS (When student's foot touches the ground)

2. Set chock blocks according to local policy * 3. Break supply line apart from hose bed and attach to suction inlet 5 4. Call for assistant at hydrant to charge supply line * 5. Loudly state "Water coming" 10 6. Slowly open discharge valve for the 1½" (1¾") hoseline 5 7. Calculate field hydraulics for the 1½" (1¾") hoseline using field hydraulic formulas 10 8. Operate pump panel throttle slowly until proper PDP pressure is reached (+ 5 psi) 5 9. Properly adjust the pressure relief valve 10

10. Open suction inlet valve while simultaneously reducing throttle to maintain proper PDP *

11. PDP should return to Step 7's calculations 10 12. Calculate field hydraulics for the 2 ½" hoseline using field hydraulic formulas 10 13. Loudly state, "Water Coming" 10 14. Slowly open discharge valve for 2½" hoseline until proper PDP is achieved (+ 5 psi) 5 15. Tank-to-pump valve (Leave open or close according to local policy) 4 16. Open tank filler valve slightly to refill tank while keeping PDP consistent 10

TIME STOPS 17. Close tank filler valve when tank is full 5 18. The student must recall and interpret the gauge readings 10

SHUTDOWN PROCEDURES 1. Loudly state, "Shutdown" 5 2. Slowly reduce pump panel throttle until main engine returns to idle 2 3. Slowly close discharge valve and suction valve 2 4. Return to cab and disengage pump 2 5. Have assistant shut-off hydrant 2 6. Relieve pressure form suction hose 2 7. Close suction valve and disconnect suction hose from suction inlet 2 8. Open tank-to-pump valve (If closed in step 14 above) 2 9. Reset pressure relief valve 2

10. Pick up chocks and return to proper location 2

RETIRED C

URRICULU

M

Page 330: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 16

STUDENT: DATE:

6-1-2: OPERATING USING A FORWARD LAY Penalty points subtracted from 150 possible points. Rated Component Value 150 MISCELLANEOUS

1. Dropped brass couplings 2 2. Opened valves too fast 2 3. Left compartment door open 2 4. Failed to remove kinks in hose(s) 2 5. Failed to disengage the pump 5

ITEMS THAT RESULT IN AUTOMATIC FAILURE 1. Omitted a step marked with an asterisk (*) Yes Failure 2. Exceeded the allotted time Yes Failure 3. Acted in a manner resulting in any personal injury Yes Failure 4. Failed to engage the pump Yes Failure 5. Ran the pump dry (without water) Yes Failure 6. Abused the apparatus Yes Failure

ALLOTTED TIME: 10:00 MINUTES TOTAL POINTS: COMPLETION TIME: PASSING SCORE: 120

Scorer's Name:

Signature:

PASS/FAIL: Pass Fail Retest

6-1-2 NOTES:

RETIRED C

URRICULU

M

Page 331: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 17

PUMPING EXERCISE 6-1-3

EXERCISE: Operating Using A Reverse Lay

This exercise can be applied when the driver/operator needs to place an appliance at the incident and then drive to the water source. Solving a hydraulics problem is required.

TIME FRAME: 5:00 (per student)

AUTHORITY: 2009 NFPA 1002: Section 5.2

MATERIALS NEEDED: • Fire apparatus • 1,000 square foot area (50' x 200') • Hydrant • Stopwatch • Monitor with 500 gpm nozzle minimum • Hose to supply monitor (Instructor choice) • 15-20 foot length of soft suction hose • Student assistant

INSTRUCTOR DIRECTIONS:

1. Demonstrate and explain each step of the exercise. 2. Hydraulics formula solutions determined using field

hydraulics for the hoseline and nozzle being used. Use the same formulas taught in the class. 3. Provide adequate space and supervision to perform the

exercise safely and without risk of injury.

STUDENT DIRECTIONS: 1. Drive the apparatus to the hydrant and spot. 2. Connect hoselines from the monitor to the apparatus. 3. Connect supply hose to the hydrant. 4. Solve the hydraulics problem, then charge the hoselines. 5. Set the relief valve. 6. Safely shutdown all lines and disengage pump. 7. Continually interpret gauge readings throughout the

exercise and recall those readings to the instructor. 8. Step-by-step procedures are listed on the Scoring Sheet.

RETIRED C

URRICULU

M

Page 332: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 18

EXERCISE: Operating Using A Reverse Lay

SCORING: 150 points possible 80% passing

1. Points are deducted for each step not completed. 2. The student fails if a step marked with an asterisk (*) is

omitted. 3. The student fails if the exercise is not completed within the

allotted time. 4. The student fails if any personal injury occurs. 5. The student fails if he or she does not engage the pump. 6. The student fails if the pump is run dry. 7. The student fails there is apparatus abuse.

SITE PREPARATION: • Monitor is set-up at a simulated fire incident. • Tank-to-pump valve is open. • Tank fill valve is closed. • Hoseline(s) are laid out on the ground, connected to the

monitor, and laid back to the hydrant

RETIRED C

URRICULU

M

Page 333: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 19

PUMPING EXERCISE 6-1-3 SCORING SHEET

STUDENT: DATE:

6-1-3: OPERATING USING A REVERSE LAY Penalty points subtracted from 150 possible points. Rated Component Value 150

1. Start engine and drive apparatus to hydrant 5 2. Spot apparatus correctly at hydrant 5 3. Set parking brake and engage pump *

TIME STARTS (When student's foot touches the ground) 4. Set chock blocks according to local policy * 5. Connect hoseline(s) from monitor to appropriate apparatus discharge(s) 5 6. Rollout suction hose to hydrant 5 7. Connect suction hose to suction inlet 5 8. Flush hydrant (Engine should not be in path of water flow) 10 9. Connect suction hose to hydrant 5

10. Open hydrant (Remove kinks from supply line) 10 11. Open inlet suction valve 5 12. Tank-to-pump valve (Leave open or close according to local policy) 5 13. Loudly state, "Water Coming" 10 14. Slowly open discharge valve(s) 5 15. Calculate field hydraulics for the appliance using field hydraulic formulas 10 16. Operate pump panel throttle slowly until proper PDP is reached (+ 5 psi) 5 17. Properly adjust the pressure relief valve 10

TIME STOPS 18. The student must recall and interpret the gauge readings 10

SHUTDOWN PROCEDURES 1. Loudly state, "Shutdown" 5 2. Slowly reduce pump panel throttle until main engine returns to idle 2 3. Slowly close discharge valve(s) 2 4. Return to cab and disengage pump 2 5. Shutoff hydrant 2 6. Close suction inlet valve 2 7. Relieve pressure from suction hose 2 8. Disconnect suction hose from suction inlet and hydrant 2 9. Replace suction hose on apparatus 2

10. Disconnect hoseline(s) to monitor and lay on ground at hydrant 2 11. Open tank-to-pump valve (If closed in step 12 above) 2

RETIRED C

URRICULU

M

Page 334: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 6-1: Introduction To The Pumping Exercises Page 20

STUDENT: DATE:

6-1-3: OPERATING USING A REVERSE LAY Penalty points subtracted from 150 possible points. Rated Component Value 150

12. Pick up chocks and return to proper location 2 MISCELLANEOUS

1. Dropped brass couplings 2 2. Opened valves too fast 2 3. Left compartment door open 2 4. Failed to remove kinks in hose(s) 2 5. Failed to disengage the pump 5

ITEMS THAT RESULT IN AUTOMATIC FAILURE 1. Omitted a step marked with an asterisk (*) Yes Failure 2. Exceeded the allotted time Yes Failure 3. Acted in a manner resulting in any personal injury Yes Failure 4. Failed to engage the pump Yes Failure 5. Ran the pump dry (without water) Yes Failure 6. Abused the apparatus Yes Failure

ALLOTTED TIME: 5:00 MINUTES TOTAL POINTS: COMPLETION TIME: PASSING SCORE: 120

Scorer's Name:

Signature:

PASS/FAIL: Pass Fail Retest

6-1-3 NOTES:

RETIRED C

URRICULU

M

Page 335: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #1 Page 1

INSTRUCTIONS: This is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. The symbol that indicates the pressure generated for hoselines during

pumping operations is "PDP." Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 243

T F 2. Water converts to vapor or steam at 200°F? Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 135

T F 3. The third principle of pressure says, "Pressure applied to a confined fluid from without is transmitted equally in all directions."

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 142

T F 4. Grid system piping for water distribution is comprised of primary and secondary feeders and distributors.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 156

T F 5. A hydrant color coded with green indicates that the hydrant will deliver between 500-999 gpm.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 325

T F 6. The nozzle pressure for a solid stream handline is 80 psi. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 166

T F 7. Nozzle reaction for a fog nozzle is ½ the gpm. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 178

T F 8. The formula for calculating gpm for a nozzle is 29.7 x d2 x √NP. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 166

T F 9. Fresh water weighs 8.5 lbs per gallon. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 136

Instructor Answer Key TTeesstt 11 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

RETIRED C

URRICULU

M

Page 336: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #1 Page 2

T F 10. One way to help reduce friction loss in hoselines is to make sure that you eliminate sharp bends.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 150

T F 11. Centrifugal pumps have the ability to pump air. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 265

T F 12. Positive displacement pumps are primarily used as priming pumps on fire apparatus.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 265

T F 13. Multi-stage pumps have more than one impeller. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 272

T F 14. Midship pumps are driven off the flywheel. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 283

T F 15. The gate valve is the most commonly used valve on fire apparatus today. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 290

T F 16. Pressure governors regulate engine throttle to maintain pump discharge pressure.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 296

T F 17. Priming devices are designed to raise atmospheric pressure within the pump.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 298

T F 18. A compound gauge must be able to register 30 in. Hg. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 302

T F 19. Auxiliary coolers are used during emergency response. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 334

T F 20. Pumping in the "pressure position" is also known as the "SERIES position."

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 274

QUIZ SCORING Each answer space is worth five points

Total Possible 100

80% Minimum 80

Score

Pass or Fail?

RETIRED C

URRICULU

M

Page 337: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #2 Page 1

SECTION I

INSTRUCTIONS: Section I is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. The friction loss coefficient for 1¾" hoseline is 10. Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Page 32

T F 2. The friction loss value for a wye is 25 psi. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 189

T F 3. The friction loss formula for calculating friction loss in 2½" hoselines is 2Q2L.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 186

T F 4. When calculating friction loss for multiple hoselines of equal size and length you will calculate the friction loss for all hoselines and then add them together to get your total friction loss.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 195-196

T F 5. Fireground hydraulics will get a more accurate friction loss calculation but it will take longer to calculate the formulas.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 251

T F 6. Using fireground hydraulics for a master stream using a 1¾" tip, the amount of water that it will deliver is 800 gpm.

Fire Apparatus Driver/Operator 1B Student Supplement, SFT, 2008 Edition, Page 49

T F 7. The elevation pressure loss that is used in fireground hydraulics is 10 psi per floor.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 225

Instructor Answer Key TTeesstt 22 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

RETIRED C

URRICULU

M

Page 338: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #2 Page 2

T F 8. Flowmeters provide the water flow in gallons per minute. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 251

T F 9. There are two basic concepts for pressure relief valves. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 294

T F 10. With the engine idling and the pump engaged, most speedometers will read between 10 to 15 mph.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 283

T F 11. On a centrifugal pump, water enters through the eye of the impeller. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 271

T F 12. The maximum flow rating of a pump is achieved at 200 psi. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 273

T F 13. The transfer valve is used to change the pump setting from volume to pressure.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 273-274

T F 14. A centrifugal pump is a positive displacement pump. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 273-274

T F 15. The tank fill valve can also be used as a relief valve. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 294

T F 16. The compound gauge can measure only pressure. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 302-303

T F 17. A positive displacement pump can pump air. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 266-267

T F 18. A two-stage pump will have one impeller and two discharge outlets. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 273

T F 19. The pump packing is used to form a semi-tight seal where the pump shaft passes through the casing.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 278-279

T F 20. The most common type of valve is the piston valve. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 290-300

RETIRED C

URRICULU

M

Page 339: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #2 Page 3

T F 21. A priming pump must have an oil or fluid source in order to establish an airtight seal.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 298-299

T F 22. A rotary vane pump is a type of centrifugal pump. Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 269-270

T F 23. A front mount pump is driven by the use of a gearbox and clutch attached to the side of the transmission.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 281-282

T F 24. A disadvantage to the rear mount pump is that the operator is directly exposed to oncoming traffic.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 285

Complete Section II on the next page.

RETIRED C

URRICULU

M

Page 340: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #2 Page 4

SECTION II

INSTRUCTIONS: Section II is a matching test. Select the item in Column 1 that most closely matches the name of the component in the diagram. Write the number of the item from Column 1 in the corresponding box for the component in the diagram.

COLUMN 1 25. Vane 26. Volute 27. Discharge 28. Hub 29. Casing

30. Eye

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 270

QUIZ SCORING Each answer space is worth five points

Total Possible 150

80% Minimum 120

Score

Pass or Fail?

27

3025

28

26

29

RETIRED C

URRICULU

M

Page 341: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #3 Page 1

SECTION I

INSTRUCTIONS: Section I is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. Cavitation can be described as water entering the pump faster than it is being discharged.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 336-337

T F 2. Open drains and valves are the most common source of air leaks during priming and drafting operations

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 343-344

T F 3. If no water is being discharged for an extended amount of time and discharge pressure is maintained at a relatively high level, the pump will overheat

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 322-323

T F 4. Due to the relatively low volume demands of sprinkler systems, multistage pumps should be in the PRESSURE (SERIES) position

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 347

T F 5. As a standard practice, it is not desirable to reduce the incoming pressure from a hydrant or other supply pumper below 20 psi

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 323-324

T F 6. A blockage of the strainer at the intake of the pump can cause a high vacuum reading on the compound gauge.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 368

Instructor Answer Key TTeesstt 33 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

RETIRED C

URRICULU

M

Page 342: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #3 Page 2

T F 7. A defective relief valve can cause excessive pressure surges when individual hoselines are shut down

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 369

T F 8. Pump discharge pressures in excess of 150 psi are not encouraged in standpipe systems

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Pages 348-350

T F 9. A low-energy foam system imparts pressure on the foam system solely by the use of a fire pump.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 463

T F 10. The speedometer will show a reading somewhat above 0 mph when power has been transferred from the road transmission to the pump transmission, provided that the apparatus speedometer reading is taken off of the rear of the transfer case.

Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Edition, Page 317

Complete Section II on the next page.

RETIRED C

URRICULU

M

Page 343: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix A – Instructor Test #3 Page 3

SECTION II

INSTRUCTIONS: Section II is a matching test. Select the one response in Column 2 that most nearly matches an item in Column 1. Write the number of the item from Column 1 in the parenthesis that precedes the appropriate response in Column 2.

EXAMPLE:

COLUMN 1 COLUMN 2 1. hammer ( 1 ) Tool used to cut 2. saw ( 2 ) Tool used to drive nails 3. wrench

COLUMN 1 COLUMN 2 11. Class A foam ( 17 ) Detergent based Page 462

12. Class B foam ( 13 ) Resists burnback Page 461

13. Protein foam ( 22 ) Mixture of foam concentrate and water before introducing air Page 451

14. Fluoroprotein foam ( 11 ) For ordinary combustibles Page 458

15. Film forming fluoroprotein foam ( 18 ) High-energy foam Page 472

16. Aqueous film forming foam ( 21 )The raw foam liquid as it rests in its storage container before the introduction of water and air Page 451

17. High-expansion foam ( 16 ) Completely synthetic Page 462

18. Compressed-air foam ( 12 ) For flammable and combustible liquids Page 458

19. Polar solvent fuels ( 15 ) Fast fire knock down and long-lasting heat resistance Page 462

20. Hydrocarbon fuels ( 19 ) Miscible in water Page 451

21. Foam concentrate 22. Foam solution Pumping Apparatus Driver/Operator Handbook, IFSTA, Second Ed

QUIZ SCORING Each answer space is worth five points

Total Possible 100

80% Minimum 80

Score

Pass or Fail?

RETIRED C

URRICULU

M

Page 344: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #1 Page 1

NAME:

DATE: TTeesstt 11 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

INSTRUCTIONS: This is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. The symbol that indicates the pressure generated for hoselines during

pumping operations is "PDP."

T F 2. Water converts to vapor or steam at 200°F?

T F 3. The third principle of pressure says, "Pressure applied to a confined fluid from without is transmitted equally in all directions."

T F 4. Grid system piping for water distribution is comprised of primary and secondary feeders and distributors.

T F 5. A hydrant color coded with green indicates that the hydrant will deliver between 500-999 gpm.

T F 6. The nozzle pressure for a solid stream handline is 80 psi.

T F 7. Nozzle reaction for a fog nozzle is ½ the gpm.

T F 8. The formula for calculating gpm for a nozzle is 29.7 x d2 x √NP.

T F 9. Fresh water weighs 8.5 lbs per gallon.

RETIRED C

URRICULU

M

Page 345: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #1 Page 2

T F 10. One way to help reduce friction loss in hoselines is to make sure that you eliminate sharp bends.

T F 11. Centrifugal pumps have the ability to pump air.

T F 12. Positive displacement pumps are primarily used as priming pumps on fire apparatus.

T F 13. Multi-stage pumps have more than one impeller.

T F 14. Midship pumps are driven off the flywheel.

T F 15. The gate valve is the most commonly used valve on fire apparatus today.

T F 16. Pressure governors regulate engine throttle to maintain pump discharge pressure.

T F 17. Priming devices are designed to raise atmospheric pressure within the pump.

T F 18. A compound gauge must be able to register 30 in. Hg.

T F 19. Auxiliary coolers are used during emergency response.

T F 20. Pumping in the "pressure position" is also known as the "SERIES position."

QUIZ SCORING Each answer space is worth five points

Total Possible 100

80% Minimum 80

Score

Pass or Fail?

RETIRED C

URRICULU

M

Page 346: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #2 Page 1

NAME:

DATE: TTeesstt 22 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

SECTION I

INSTRUCTIONS: Section I is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. The friction loss coefficient for 1¾" hoseline is 10.

T F 2. The friction loss value for a wye is 25 psi.

T F 3. The friction loss formula for calculating friction loss in 2½" hoselines is 2Q2L.

T F 4. When calculating friction loss for multiple hoselines of equal size and length you will calculate the friction loss for all hoselines and then add them together to get your total friction loss.

T F 5. Fireground hydraulics will get a more accurate friction loss calculation but it will take longer to calculate the formulas.

T F 6. Using fireground hydraulics for a master stream using a 1¾" tip, the amount of water that it will deliver is 800 gpm.

T F 7. The elevation pressure loss that is used in fireground hydraulics is 10 psi per floor.

RETIRED C

URRICULU

M

Page 347: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #2 Page 2

T F 8. Flowmeters provide the water flow in gallons per minute.

T F 9. There are two basic concepts for pressure relief valves.

T F 10. With the engine idling and the pump engaged, most speedometers will read between 10 to 15 mph.

T F 11. On a centrifugal pump, water enters through the eye of the impeller.

T F 12. The maximum flow rating of a pump is achieved at 200 psi.

T F 13. The transfer valve is used to change the pump setting from volume to pressure.

T F 14. A centrifugal pump is a positive displacement pump.

T F 15. The tank fill valve can also be used as a relief valve.

T F 16. The compound gauge can measure only pressure.

T F 17. A positive displacement pump can pump air.

T F 18. A two-stage pump will have one impeller and two discharge outlets.

T F 19. The pump packing is used to form a semi-tight seal where the pump shaft passes through the casing.

T F 20. The most common type of valve is the piston valve.

RETIRED C

URRICULU

M

Page 348: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #2 Page 3

T F 21. A priming pump must have an oil or fluid source in order to establish an airtight seal.

T F 22. A rotary vane pump is a type of centrifugal pump.

T F 23. A front mount pump is driven by the use of a gearbox and clutch attached to the side of the transmission.

T F 24. A disadvantage to the rear mount pump is that the operator is directly exposed to oncoming traffic.

Complete Section II on the next page.

RETIRED C

URRICULU

M

Page 349: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #2 Page 4

SECTION II

INSTRUCTIONS: Section II is a matching test. Select the item in Column 1 that most closely matches the name of the component in the diagram. Write the number of the item from Column 1 in the corresponding box for the component in the diagram.

COLUMN 1 25. Vane 26. Volute 27. Discharge 28. Hub 29. Casing

30. Eye

QUIZ SCORING Each answer space is worth five points

Total Possible 150

80% Minimum 120

Score

Pass or Fail?

RETIRED C

URRICULU

M

Page 350: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #3 Page 1

NAME:

DATE: TTeesstt 33 Each answer space is worth five points. Some questions may have more than one correct answer. You have 30 minutes to complete the entire test.

SECTION I

INSTRUCTIONS: Section I is a true-false test. If the statement is true, draw a circle around the "T." If the statement is false, draw a circle around the "F."

EXAMPLE: T F The Incident Command System was developed by the fire service.

T F 1. Cavitation can be described as water entering the pump faster than it is being discharged.

T F 2. Open drains and valves are the most common source of air leaks during priming and drafting operations

T F 3. If no water is being discharged for an extended amount of time and discharge pressure is maintained at a relatively high level, the pump will overheat

T F 4. Due to the relatively low volume demands of sprinkler systems, multistage pumps should be in the PRESSURE (SERIES) position

T F 5. As a standard practice, it is not desirable to reduce the incoming pressure from a hydrant or other supply pumper below 20 psi

T F 6. A blockage of the strainer at the intake of the pump can cause a high vacuum reading on the compound gauge.

RETIRED C

URRICULU

M

Page 351: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #3 Page 2

T F 7. A defective relief valve can cause excessive pressure surges when individual hoselines are shut down

T F 8. Pump discharge pressures in excess of 150 psi are not encouraged in standpipe systems

T F 9. A low-energy foam system imparts pressure on the foam system solely by the use of a fire pump.

T F 10. The speedometer will show a reading somewhat above 0 mph when power has been transferred from the road transmission to the pump transmission, provided that the apparatus speedometer reading is taken off of the rear of the transfer case.

Complete Section II on the next page.

RETIRED C

URRICULU

M

Page 352: fire apparatus driver/operator 1b

FIRE APPARATUS DRIVER/OPERATOR 1B Pump Operations

October 2008 Appendix B – Student Test #3 Page 3

SECTION II

INSTRUCTIONS: Section II is a matching test. Select the one response in Column 2 that most nearly matches an item in Column 1. Write the number of the item from Column 1 in the parenthesis that precedes the appropriate response in Column 2.

EXAMPLE:

COLUMN 1 COLUMN 2 1. hammer ( 1 ) Tool used to cut 2. saw ( 2 ) Tool used to drive nails 3. wrench

COLUMN 1 COLUMN 2 11. Class A foam ( ) Detergent based 12. Class B foam ( ) Resists burnback

13. Protein foam ( ) Mixture of foam concentrate and water before introducing air

14. Fluoroprotein foam ( ) For ordinary combustibles

15. Film forming fluoroprotein foam ( ) High-energy foam

16. Aqueous film forming foam ( )The raw foam liquid as it rests in its storage container before the introduction of water and air

17. High-expansion foam ( ) Completely synthetic 18. Compressed-air foam ( ) For flammable and combustible liquids

19. Polar solvent fuels ( ) Fast fire knock down and long-lasting heat resistance

20. Hydrocarbon fuels ( ) Miscible in water 21. Foam concentrate 22. Foam solution

QUIZ SCORING Each answer space is worth five points

Total Possible 100

80% Minimum 80

Score

Pass or Fail?