figure 1. extending the number of recording channels … · brain products press release october...

1
www.brainproducts.com Brain Products Press Release October 2011, Volume 40 page 13 of 18 New Products Easy, Easier, the new EIB64-A by Dr. Baris Yesilyurt EASYCAP is proud to announce the release of the EIB64-A, the next-generation version of its 64 channel Electrode Input Box. The EIB64-A is an innovative and easy-to-use interface that is used to connect EEG recording caps and electrodes with Brain Products BrainAmp amplifiers. The EIB64-A replaces its predecessor, the EIB64 interface, which was a 64-channel Electrode Input Box that only allowed electrodes with single-input safety sockets to be connected to the BrainAmp recording amplifiers. The EIB64-A comes with 64 single inputs for 1.5 mm touch-proof safety sockets, a double input for the reference channel plus a double input for the ground channel, 2 common connector inputs (each for 32 channels), 2 common connector outputs (each for 32 channels), and 72 DIP switches to permit each individual common connector channel to be switched either ON or OFF. This design makes the EIB64-A much more versatile than its EIB64 predecessor, enabling it to be used in the following scenarios: 1) Connecting up to 64 individual electrodes with BrainAmp systems using EIB64-A as a quick-connect interface. It is quick because only the flat ribbon cables need to be connected to (or disconnected from) the amplifier, while the individual electrodes can stay permanently plugged in. 2) Connecting a BrainCap or EasyCap with common connector output and additional single electrodes to the same BrainAmp Figure 2. Bridging defective electrodes using replacement electrodes, even during cap mounting systems. This opens up new possibilities and enables the additional single electrodes to be used not only for unipolar measurements, but also for bipolar measurements when used in combination with a bipolar BrainAmp ExG amplifier (see Fig. 1). 3) Bridging defective cap electrodes easily and quickly using hook-on (or replacement) electrodes with single input safety sockets without immediately having to replace the faulty electrodes (see Fig. 2). This very handy solution avoids you having to suspend taking measurements or rescheduling impending recordings until any faulty components have been replaced. 4) As with the EIB64-A’s predecessor, it will be possible to combine 2 or more EIB64-As for making measurements that involve more than 64 channels by simply shorting the reference and ground channels of 2 or more EIB64-As. 5) On request, and in return for a modest customization fee, other input/output connector types can be built into the EIB64-A to make it compatible with third-party amplifiers as well. The maximum number of channels is 72. We firmly believe that the new EIB64-A represents a great advance for those of you who are working with EIBs. We hope you will agree! If you have any questions or comments, or if you would like to learn more about the EIB64-A, please do not hesitate to contact us at [email protected]. Figure 1. Extending the number of recording channels using additional individual electrodes, e.g. for polygraphy EIB64-A flat ribbon cables Brain Products BrainAmp amplifiers Brain Products BrainAmp amplifier EIB64-A flat ribbon cable BrainCap box BrainCap box

Upload: vuonghanh

Post on 13-Oct-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Figure 1. Extending the number of recording channels … · Brain Products Press Release October 2011, Volume 40 page 13 of 18 New Products Easy, Easier, the new EIB64-A by Dr. Baris

www.brainproducts.com

Brain Products Press Release October 2011, Volume 40

page 13 of 18

New Products

Easy, Easier, the new EIB64-A by Dr. Baris Yesilyurt

EASYCAP is proud to announce the release of the EIB64-A, the

next-generation version of its 64 channel Electrode Input Box. The

EIB64-A is an innovative and easy-to-use interface that is used to

connect EEG recording caps and electrodes with Brain Products

BrainAmp amplifiers.

The EIB64-A replaces its predecessor, the EIB64 interface, which

was a 64-channel Electrode Input Box that only allowed electrodes

with single-input safety sockets to be connected to the BrainAmp

recording amplifiers. The EIB64-A comes with 64 single inputs for

1.5 mm touch-proof safety sockets, a double input for the reference

channel plus a double input for the ground channel, 2 common

connector inputs (each for 32 channels), 2 common connector

outputs (each for 32 channels), and 72 DIP switches to permit each

individual common connector channel to be switched either ON or

OFF.

This design makes the EIB64-A much more versatile than its EIB64

predecessor, enabling it to be used in the following scenarios:

1) Connecting up to 64 individual electrodes with BrainAmp

systems using EIB64-A as a quick-connect interface. It is quick

because only the flat ribbon cables need to be connected to (or

disconnected from) the amplifier, while the individual electrodes

can stay permanently plugged in.

2) Connecting a BrainCap or EasyCap with common connector

output and additional single electrodes to the same BrainAmp

Figure 2. Bridging defective electrodes using replacement electrodes, even during cap mounting

systems. This opens up new possibilities and enables the

additional single electrodes to be used not only for unipolar

measurements, but also for bipolar measurements when used in

combination with a bipolar BrainAmp ExG amplifier (see Fig. 1).

3) Bridging defective cap electrodes easily and quickly using

hook-on (or replacement) electrodes with single input safety

sockets without immediately having to replace the faulty

electrodes (see Fig. 2).

This very handy solution avoids you having to suspend taking

measurements or rescheduling impending recordings until any

faulty components have been replaced.

4) As with the EIB64-A’s predecessor, it will be possible to combine

2 or more EIB64-As for making measurements that involve more

than 64 channels by simply shorting the reference and ground

channels of 2 or more EIB64-As.

5) On request, and in return for a modest customization fee, other

input/output connector types can be built into the EIB64-A to make

it compatible with third-party amplifiers as well. The maximum

number of channels is 72.

We firmly believe that the new EIB64-A represents a great advance

for those of you who are working with EIBs. We hope you will agree!

If you have any questions or comments, or if you would like to learn

more about the EIB64-A, please do not hesitate to contact us at

[email protected].

Figure 1. Extending the number of recording channels using additional individual electrodes, e.g. for polygraphy

EIB64-A flat ribbon cablesBrain Products

BrainAmp amplifiers

Brain Products BrainAmp amplifierEIB64-A

flat ribbon cable

BrainCap box

BrainCap box