fiberoptic displacement sensor model dms-rc171 displacement sensor model dms-rc171 ... internally,...

4
PHILTEC ® Precision Dynamic Measurements www.philtec.com Tip & Cable Dimensions Fiberoptic Displacement Sensor Model DMS-RC171 Digital Sensor Data Sheet PHILTEC, Inc. Mar 2018 Features • Reflectance Compensated Output • Ø 4.3 mm Spot Size • 15 mm Operating Range • Ambient Light Rejection REFLECTANCE COMPENSATION These are reflective type transducers based upon detecting the intensity of reflected light. RC Model sensors have a pair of fiberoptic detectors in the sensor tip. Light reflected off a target follows two separate paths back to the electronics where a ratiometric calculation provides the distance mea- surement which is independent of varying surface reflectance; i.e., reflectance compensated. AMBIENT LIGHT REJECTION Incoming light signals are bandpass filtered at a wavelength of 850 ±22 nm. For The Measurement of Distance, Displacement and Vibration for Targets > Ø 4.34 mm A B C ØC Side-by-Side Fiberopcs In Sensor Tip Fiberoptic Cable & Sensor Tip - Actual Size DISTANCE (GAP) OUTPUT These sensors provide a linearized distance output with RS232 or USB communication. Dynamic light signals reflected from target surfaces are converted to distances by comparing the sensor signals to gap calibration tables stored on-board the sensor. DRC171:1 FEATURE mm inch Tip Outer Diameter, Ø C 4.75 0.187 Fiberoptic Diameter 4.34 0.171 Tip Length, C 38.1 1.5 Collar Length, B 15.9 0.625 Collar Diameter, Ø B 7.92 0.312 Cable Length, A 915 36 Cable Diameter, Ø A 6.86 0.275 Cable Min. Bend Radius 29 1.125

Upload: doandan

Post on 28-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

PHILTEC®

Precision Dynamic Measurements

www.philtec.com

Tip & Cable Dimensions

Fiberoptic Displacement Sensor

Model DMS-RC171

Digital Sensor Data Sheet PHILTEC, Inc. Mar 2018

Features•  Reflectance Compensated Output

  •  Ø 4.3 mm Spot Size  •  15 mm Operating Range•  Ambient Light Rejection

REFLECTANCE COMPENSATION These are reflective type transducers based upon detecting the intensity of reflected light.  RC Model sensors have a pair of fiberoptic detectors  in  the sensor tip.  Light reflected off a target follows two separate  paths  back  to  the  electronics  where  a ratiometric calculation provides the distance mea-surement which is independent of varying surface reflectance; i.e., reflectance compensated.

AMBIENT LIGHT REJECTIONIncoming  light  signals  are bandpass  filtered at  a wavelength of 850 ±22 nm.

For The Measurement of Distance, Displacement and Vibrationfor Targets > Ø 4.34 mm

A B C

ØCSide-by-Side Fiberoptics

In Sensor Tip

Fiberoptic Cable & Sensor Tip - Actual Size

DISTANCE (GAP) OUTPUTThese sensors provide a linearized distance output with RS232 or USB communication.  Dynamic light signals reflected from target surfaces are converted to distances by comparing the sensor signals to gap calibration tables stored on-board the sensor.

DRC171:1

FEATURE mm inch

Tip Outer Diameter, Ø C 4.75 0.187Fiberoptic Diameter 4.34 0.171

Tip Length, C 38.1 1.5Collar Length, B 15.9 0.625

Collar Diameter, Ø B 7.92 0.312Cable Length, A 915 36

Cable Diameter, Ø A 6.86 0.275Cable Min. Bend Radius 29 1.125

The analog  signal  input  to  the  sensor’s microproces-sor (shown above) is converted to a linearized distance output by comparing the input signals to gap calibration tables stored on-board the sensor. The sensor can be gapped  for  measurements  anywhere  within  the  sen-sor’s  total  operating  range.  Optimum  performance  is achieved where  the RC  input signal has  the steepest slope (highest sensitivity, ~0.5 - 13 mm). 

Sensor Accuracy is measured at 2.5 samples/sec. 

0 5 10 15

mm

-1

-0.5

0

0.5

1

Mic

rons

Accuracy

0 5 10 15

Gap To Target, mm

0

5

10

15

Sens

or O

utpu

t, m

mTypical DMS-RC171 Output

NOTES:*These specifications represent best case performance where: •  the target is flat, smooth and highly reflective•  the sensor is perpendicular to the target•  the sensor is gapped to its range of highest sensitivity (~mid-range) •  fiberoptic cable lengths are standard and the cables are not connectorized

**DMS Control Software includes a data averaging filter for averaging data samples from:   2 samples (the fastest rate) to 4096 samples (best resolution).  

Internally, the sensor continuously reads target data at a clock rate of 10416.75 Hz.  ADC AVG = the number of internal readings averaged before sending data out to the PC.  

Samples/Sec for any ADC AVG setting can be calculated as follows:  •  S/S = 10,416.75 / ADC AVG

Custom Hardware To Customer Specifications

PHILTEC, INC., ANNAPOLIS, MD USA 410-757-4404 800-453-6242 e-mail [email protected]

Standard Specifications - RC171Electronics Fiberoptics USB or RS232

Light Source 850 nm Light Beam Spread 25° Total Range 15 mmInput Voltage +12 VDC Cable Sheathing PVC over Steel Monocoil Linear Range 0 - 15 mm

Input Current 500 ma max Tip Epoxy Outgas0.3% @ 200°C2.4% @ 300°C

ReflectanceResolution

0.5%

Bandwidth 5 KHz maxTip Operating

Pressure10 bar

TemperatureResolution

0.06°C

Iso-thermal Drift

0.05%Tip

Operating Temperature

-55 to 200°C continuous;to 300°C intermittent

1-2 hours

Resolution* ADC AVG = 2 ADC AVG = 16 ADC AVG = 256 ADC AVG = 4096

** samples/sec pk-pk 5208                     650 nm             651                     250 nm               41                     130 nm                 2.5                    25 nm

Weight 1.1 kg -2.4 lbs. Fibers Glass

0 5 10 15Distance To Target, mm

0

20

40

60

80

100

RC FUNCTION, % Input Sensitivity

PHILTEC DMS-RC171TYPICAL RESPONSE

Calibration To Front Surface Mirror

0 5 10 15mm

-10

-5

0

5

10

Mic

rons

Repeatability

PHILTEC DMS-RC171TYPICAL RESPONSE

Calibration To Front Surface Mirror

DRC171:2

PHILTEC, INC., ANNAPOLIS, MD USA 410-757-4404 800-453-6242 e-mail [email protected]

Three Instruments To Choose From:

• Model 2DMS-RC171 ... Two Channel DMS with RS232 output• Model mDMS-RC171 ... miniDMS with RS232 output• Model muDMS-RC171 ... miniDMS with USB output

2DMS-RC171

mDMS-RC171

muDMS-RC171

3. muDMS units include: •  Electronics with USB communication

DRC171:3

69.195

145

161.7

173

50.7

9.53 x 3.96 SLOTS

1.6

2DMS SENSOR

DIMENSIONS, mm

4 Places

RS232 Output

PHILTEC PHILTEC. INC.ANNAPOLIS, MD 21409

DATE DWG. NO.

2DMS AMPLIFIER

6 Mar '18 2DMS

2. mDMS units include: •  Electronics with RS-232 communication

1. Standard DMS units include:  •  Electronics with RS-232 communication  •  Keypad/LCD for local operation 

139.2

110.8

127.7

54.6 82.4

1.6

SLOTS, 4 x 9.5, 4 Places

47.6

muDMS SENSOR

DIMENSIONS, mmwith USB Output

PHILTEC, INC.ANNAPOLIS, MD 21409

DATE DWG. NO.

PHILTEC

muDMS6 Mar '13 muDMS

140

112

129

35.6 60.5

1.6

SLOTS, 4 x 9.5, 4 Places

32.6

mDMS SENSOR

DIMENSIONS, mm

with RS232 Output

PHILTEC, INC.ANNAPOLIS, MD 21409

DATE DWG. NO.

PHILTEC

miniDMS6 Mar '13 mDMS

PHILTEC, INC., ANNAPOLIS, MD USA 410-757-4404 800-453-6242 e-mail [email protected]

DMS SETUP and CONTROL SOFTWAREPhiltec provides freeware with every digital sensor purchase. This powerful software is a very useful tool for controlling sensors, viewing live data, and for saving data to files. 

Sensors have storage capacity for 25 calibration tables. Every new sensor is provided with calibra-tions to:

1.  A front surface mirror2.  A diffuse aluminum target

The DMS software provides means for copying and pasting sensor calibration data, as well as for creating and storing new calibration tables.

SOFTWARE & FIRMWARE UPDATESDMS sensors can be updated remotely at any PC. The most current edition of software and firmwareis posted at http://www.philtec.com/downloadssupport/firmware.html.  A short tutorial video link is also available there.

DRC171:4