IEC CYLINDRICAL FUSE-LINKS
Mersen aM and gG fuse-links cover a wide range of physical sizes and
ampere ratings for 400, 500, and 690VAC for protection in electrical
distribution circuits and various industrial applications. Most ratings
are available in size 8x31 and size 10x38 with an optional indicator,
and in size 14x51 and 22x58 with an optional striker to activate
an auxiliary contact. Size 10x38 is also available with striker. All
cylindrical fuse-links have ceramic bodies and silver-plated contacts.
Cylindrical fuse-links “gG” are used for the protection of cables,
motors and LV-networks. They limit and cut off unacceptable
overcurrents and short-circuit currents up to their nominal breaking
capacity. Cylindrical fuse-links “gG” also protect electrical equipment
and installations against the dynamic effect of high short-currents.
Our technology and process was designed to ensure highly reliable
technical performance.
FEATURES & BENEFITS
• Reduced size
• Full range protection
• Visual indication of fuse operation
• Safest and most reliable protection system
APPLICATIONS
• gG type for protection of line, cable against overload and short circuit in various industrial application and electrical distribution circuits.
STANDARDS
• IEC 60269-1 & -2 (electrically only for the range with striker)
• Approved by Lloyd’s Register of Shipping and Bureau Veritas
TECHNICAL DATA OVERVIEW
Voltage Range AC 400 ... 690 VAC
Ampere Range (A) 0.5 ... 32 A
Speed/Characteristic gG
I.R. AC (IEC) 120 kA
Body Material Ceramic
Body Style cylindrical
Contact Materials Silver plated copper
Product Size 10x38 mm
LOW VOLTAGE IEC FUSES
Ferrule fuse-links 10x38 gG 400 to 690VAC
Ferrule fuse-links 10x38 gG 400 to 690VAC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 2
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Size 10,3x38 gG 400/500VAC without indicator
Catalognumber
Reference number
Rated voltage AC (IEC)
Rated current InRated breaking capacity AC
Power dissipation at In
Weight
FR10GG50V0.5 C211027 500 V 0.5 A 120 kA 0.07 W 8.3 g
FR10GG50V1 B212061 500 V 1 A 120 kA 0.45 W 8.3 g
FR10GG50V2 D213098 500 V 2 A 120 kA 0.5 W 8.3 g
FR10GG50V4 X213598 500 V 4 A 120 kA 0.85 W 8.3 g
FR10GG50V6 K215128 500 V 6 A 120 kA 0.95 W 8.3 g
FR10GG50V8 D217169 500 V 8 A 120 kA 1.15 W 8.3 g
FR10GG50V12 W219761 500 V 12 A 120 kA 1.4 W 8.3 g
FR10GG50V10 S218194 500 V 10 A 120 kA 1.3 W 8.3 g
FR10GG50V16 G200750 500 V 16 A 120 kA 1.9 W 8.3 g
FR10GG50V20 D211028 500 V 20 A 120 kA 2.4 W 8.3 g
FR10GG50V25 E213099 500 V 25 A 120 kA 2.7 W 8.3 g
FR10GG40V32 A214107 400 V 32 A 120 kA 2.8 W 8.3 g
FR10GG50V6
FR10GG40V32
Size 10,3x38 gG 250/400VAC with striker
Catalognumber
Reference number
Rated voltage AC (IEC)
Rated current InRated breaking capacity AC
Power dissipation at In
Weight
FR10GG40V2P G083703 400 V 2 A 100 kA 0.6 W 9.2 g
FR10GG40V4P D084758 400 V 4 A 100 kA 0.75 W 9.2 g
FR10GG40V6P Y084799 400 V 6 A 100 kA 0.9 W 9.2 g
FR10GG40V8P F083955 400 V 8 A 100 kA 1 W 9.2 g
FR10GG40V10P A084801 400 V 10 A 100 kA 1.1 W 9.2 g
FR10GG40V12P G083956 400 V 12 A 100 kA 1.25 W 9.2 g
FR10GG40V16P X084798 380 V 16 A 100 kA 1.35 W 9.2 g
FR10GG40V20P Z084800 380 V 20 A 100 kA 1.45 W 9.2 g
FR10GG25V25P H083957 250 V 25 A 100 kA 1.7 W 9.2 g
FR10GG25V32P E083954 250 V 32 A 100 kA 2.2 W 9.2 g
Size 10,3x38 gG 400/500VAC with indicator
Catalognumber
Reference number
Rated voltage AC (IEC)
Rated current InRated breaking capacity AC
Power dissipation at In
Weight
FR10GG50V2I S216653 500 V 2 A 120 kA 0.5 W 8.3 g
FR10GG50V4I E217170 500 V 4 A 120 kA 0.85 W 8.3 g
FR10GG50V6I T218195 500 V 6 A 120 kA 0.95 W 8.3 g
FR10GG50V8I V219231 500 V 8 A 120 kA 1.15 W 8.3 g
FR10GG50V10I E222207 500 V 10 A 120 kA 1.3 W 8.3 g
FR10GG50V12I H200751 500 V 12 A 120 kA 1.4 W 8.3 g
FR10GG50V16I H201809 500 V 16 A 120 kA 1.9 W 8.3 g
FR10GG50V20I X211551 500 V 20 A 120 kA 2.4 W 8.3 g
FR10GG50V25I W212585 500 V 25 A 120 kA 2.7 W 8.3 g
FR10GG40V32I Z213600 400 V 32 A 120 kA 2.8 W 8.3 g
FR10GG40V32I
PRODUCT RANGE
Ferrule fuse-links 10x38 gG 400 to 690VAC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 3
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Size 10,3x38 gG 690VAC without indicator
Catalognumber
Reference number
Rated voltage AC (IEC)
Rated current InRated breaking capacity AC
Power dissipation at In
Weight
FR10GG69V1 R302787 690 V 1 A 120 kA 0.45 W 9 g
FR10GG69V2 S302788 690 V 2 A 120 kA 0.55 W 9 g
FR10GG69V4 T302789 690 V 4 A 120 kA 0.6 W 9 g
FR10GG69V6 V302790 690 V 6 A 120 kA 0.9 W 9 g
FR10GG69V8 W302791 690 V 8 A 120 kA 1 W 9 g
FR10GG69V10 X302792 690 V 10 A 120 kA 1.15 W 9 g
FR10GG69V12 Y302793 690 V 12 A 120 kA 1.4 W 9 g
FR10GG69V16 Z302794 690 V 16 A 120 kA 1.9 W 9 g
FR10GG69V6
PRODUCT RANGE
Ferrule fuse-links 10x38 gG 400 to 690VAC
1 2 3 5 7
10
20
30
50
70
10
0
20
0
30
0
50
0
70
0
10
00
0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
0.5 A
1 A
2 A
4 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 500V gG without striker
TIME CURRENT CHARACTERISTIC CURVES
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 4
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
1 2 3 5 7
10
20
30
50
70
10
0
20
0
30
0
50
0
70
0
100
0
200
0
300
0 0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
25 A
6 A
8 A
10 A
12 A
16 A
20 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 500V gG without striker
TIME CURRENT CHARACTERISTIC CURVES
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 5
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
10
20
30
50
70
10
0
20
0
30
0
50
0
70
0
10
00
20
00
30
00
50
00
70
00
10
00
0 0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
32 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 400V gG without striker
TIME CURRENT CHARACTERISTIC CURVES
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 6
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
TIME CURRENT CHARACTERISTIC CURVES1 2 3 5 7
10
20
30
50
70
10
0
20
0
30
0
50
0
70
0
10
00
0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
4 A
6 A
1 A
2 A
12 A
16 A
8 A
10 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 690V gG without striker
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 7
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
10
00
0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
10 A
2 A
12 A
4 A
16 A
6 A
20 A
8 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 400V gG with striker
TIME CURRENT CHARACTERISTIC CURVES
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 8
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
TIME CURRENT CHARACTERISTIC CURVES10
20
30
50
70
100
200
300
500
700
10
00
20
00
30
00
50
00
70
00
10
000
0.0001
0.0002
0.0003
0.0005
0.0007
0.001
0.002
0.003
0.005
0.007
0.01
0.02
0.03
0.05
0.07
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
25 A
32 A
Actu
al p
re-a
rcin
g t
ime (
s)
RMS value of prospective current (A) +/- 8%
Size 10x38 250V gG with striker
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 9
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
1 2 3 5 7
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
20000
30000
50000
70000
100000
200000
300000
500000
700000
1e+
06 5
7
10
20
30
50
70
100
200
300
2000
3000
500
700
1000
0.5 A
1 A
2 A
4 A
lm = 2.3 lp
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 500V gG without striker
CUT-OFF CURRENT CHARACTERISTIC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 10
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
30
50
70
10
0
20
0
30
0
50
0
70
0
100
0
200
0
300
0
500
0
700
0
10
00
0
20
00
0
30
00
0
50
00
0
70
00
0
10
000
0
20
000
0
30
000
0 50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
25 A
6 A
8 A
10 A
12 A
16 A
20 A
lm = 2.3 lp
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 500V gG without striker
10
0
20
0
30
0
50
0
70
0
100
0
200
0
300
0
500
0
700
0
10
00
0
20
00
0
30
00
0
50
00
0
70
00
0
10
000
0
20
000
0
30
000
0
50
000
0
70
000
0
1e
+0
6 500
700
1000
2000
3000
5000
7000
10000
lm = 2.3 lp
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 400V gG without striker
CUT-OFF CURRENT CHARACTERISTIC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 11
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
3 5 7
10
20
30
50
70
10
0
20
0
30
0
50
0
70
0
10
00
20
00
30
00
50
00
70
00
100
00
200
00
300
00
500
00
700
00
10
00
00
20
00
00
30
00
00
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
4 A6 A
1 A
2 A
lm = 2.3 lp
12 A16 A
8 A10 A
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 690V gG without striker
CUT-OFF CURRENT CHARACTERISTIC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 12
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
20000
30000
50000
70000
100000
200000
300000
500000 10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000
7000
10000
16 A
20 A
2 A
4 A
6 A
8 A
10 A
12 A
lm = 2.3 lp
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 400V gG with striker
CUT-OFF CURRENT CHARACTERISTIC
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 13
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
CUT-OFF CURRENT CHARACTERISTIC1
00
20
0
30
0
50
0
70
0
10
00
20
00
30
00
50
00
70
00
10
000
20
000
30
000
50
000
70
000
10
00
00
20
00
00
30
00
00
50
00
00
70
00
00
1e
+0
6 100
200
300
500
700
1000
2000
3000
5000
7000
10000
25 A
32 Alm = 2.3 lp
Maxim
um
peak let
thru
cu
rren
t Ic
(A
)
50 Hz RMS symmetrical prospective current Ip (A)
Size 10x38 250V gG with striker
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 14
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
0,05
0,07
0,1
0,2
0,3
0,5
0,7
1
2
3
5
7
10
20
30
50
70
0.5
A
1 A
2 A
4 A
500V290V
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 500V gG without striker
PRE-ARCING AND OPERATING I²T CHARACTERISTICS
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
500V290V
25 A
6 A
8 A
10 A
12 A
16 A
20 A
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 500V gG without striker
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 15
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
100
200
300
500
700
1000
2000
3000
5000
7000
10000
400V230V
32 A
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 400V gG without striker
0,3
0,5
0,7
1
2
3
5
7
10
20
30
50
70
100
200
300
500
700
1000
4 A
6 A
1 A
2 A
12 A
16 A
8 A
10 A
690V400V
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 690V gG without striker
PRE-ARCING AND OPERATING I²T CHARACTERISTICS
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 16
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
PRE-ARCING AND OPERATING I²T CHARACTERISTICS
10
20
30
50
70
100
200
300
500
700
1000
2000
3000
5000 400V250V
4 A
2 A
8 A
6 A
12 A
10 A
20 A
16 A
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 400V gG with striker
100
200
300
500
700
1000
2000
3000
5000
7000
10000
250V
32 A
25 A
pre-arcing I²t
Pre
-arc
ing
an
d c
leari
ng
I²t
(A
²s)
Rated current (A)
Size 10x38 250V gG with striker
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 17
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.
Ferrule fuse-links 10x38 gG 400 to 690VAC
DIMENSIONS
10
.11
0.1
38
± 0
.6
+0.2Ø 10.2
0
Size 10x38 gG without indicator (1001210)
Dimensions in mm
10
.110.1
38
± 0
.6
+0.2Ø 10.2
0
Visual indicator
Size 10x38 gG with indicator (1002537)
Dimensions in mm
10
10
38.2
± 0
.7
39.2
± 1
Ø 10.3 ± 0.1
Striker
Size 10x38 gG with striker (33907)
Dimensions in mm
Low Voltage IEC Fuses / DS-LFCY10GG-07-0516_EN
EP.MERSEN.COM 18
ME
RS
EN
rese
rves
the r
igh
t to
ch
an
ge, u
pd
ate
or
co
rrect,
wit
ho
ut
no
tice, any in
form
ati
on
co
nta
ined
in
th
is d
ata
sheet.