features indications contraindications model 3b76 ... · *the booster spring unit cannot be removed...

2
Indications Contraindications Stroke Cerebral palsy Multiple sclerosis Spina bifida Spinal cord injury Charcot-Marie-Tooth Other neuromotor deficits Lower limb functional deficits as a result of: Patient weight greater than 100 kg (220 lb) Independent adjustment of: Ankle alignment Plantarflexion/dorsiflexion range of motion Plantarflexion/dorsiflexion spring stiffness Independent ankle alignment range of 10° (4) high stiffness spring options included with booster spring models (Figure 1) Compatible with unilateral or bilateral orthotic designs Features Small Adult Ankle Joint ( 16mm Systems ) Product Data Sheet Model 3B76 Component Selection *Important: Thermoplastic unilateral AFOs require Camber Axis Triple Action ® Companion Joint, or other free motion ankle joint Composite Unilateral Bilateral Wet Lamination like Becker BCO Shadow™, Max™ or PrePreg Wet Lamination like Becker BCO Lite™, Shadow™, Maxor PrePreg Fabrication Options Thermoplastic 5mm (3/16") Polypropylene Unilateral* Bilateral 5mm (3/16") Polypropylene Patent Pending ©2020 Becker Orthopedic Appliance Co., All rights reserved. Revision 05/01/20 Acorn Regulatory Consultancy Services Limited Knockmorris Cahir Co. Tipperary Ireland, Postcode: E21 R766 P 012 4626 8456 F 012 4626 8648 * Only available direct from Becker Orthopedic in some countries NORMAL 90 kg / 200 lb 100 kg / 220 lb No Booster Plantarflexion Resist Booster Dorsiflexion Resist Booster Plantarflexion & Dorsiflexion Resist Boosters Either 3B76-A1* 3B76-A0* 3B76-A3 3B76-A1* 3B76-A2* 3B76-A2* Either NORMAL ABNORMAL ABNORMAL NORMAL ABNORMAL Right Left Left Right Right Left Left Right Lateral Medial Lateral Medial Lateral Medial Lateral Medial Booster Configuration Unilateral Side Order No. Bilateral Early Stance Phase Late Stance Phase Leg

Upload: others

Post on 04-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Features Indications Contraindications Model 3B76 ... · *The Booster Spring Unit cannot be removed from the Triple Action component housing. Doing so will destroy the Booster and

Indications

Contraindications

Stroke

Cerebral palsy

Multiple sclerosis

Spina bifida

Spinal cord injury

Charcot-Marie-Tooth

Other neuromotor deficits

•••••••

Lower limb functional deficits as a result of:

Patient weight greater than 100 kg (220 lb)

Independent adjustment of:

Ankle alignmentPlantarflexion/dorsiflexion range of motionPlantarflexion/dorsiflexion spring stiffness

Independent ankle alignment range of 10°

(4) high stiffness spring options included with booster spring models (Figure 1)

Compatible with unilateral or bilateral orthotic designs

Features

Small Adult Ankle Joint( 16mm Systems )

Product Data Sheet

Model 3B76 Component Selection

*Important: Thermoplastic unilateral AFOs require Camber Axis Triple Action® Companion Joint, or other free motion ankle joint

Composite

Unilateral

Bilateral

Wet Lamination like Becker BCO Shadow™, Max™ or PrePreg

Wet Lamination like Becker BCO Lite™, Shadow™, Max™ or PrePreg

Fabrication Options

Thermoplastic

5mm (3/16") Polypropylene

Unilateral*

Bilateral5mm (3/16") Polypropylene

Patent Pending©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 05/01/20

Acorn Regulatory Consultancy Services Limited

Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766

P 012 4626 8456 F 012 4626 8648

*Only available direct from Becker Orthopedic in some countries

NORMAL

90 kg / 200 lb

100 kg / 220 lb

No Booster Plantarflexion Resist Booster

Dorsiflexion Resist Booster

Plantarflexion & Dorsiflexion Resist

Boosters

Either

3B76-A1*3B76-A0* 3B76-A33B76-A1*3B76-A2* 3B76-A2*

Either

NORMAL

ABNORMAL

ABNORMAL

NORMAL

ABNORMAL

RightLeft LeftRight RightLeft LeftRight

Lateral MedialLateral Medial Lateral MedialLateral Medial

BoosterConfiguration

Unilateral

Side

Order No.

Bilateral

Early StancePhase

Late StancePhase

Leg

Page 2: Features Indications Contraindications Model 3B76 ... · *The Booster Spring Unit cannot be removed from the Triple Action component housing. Doing so will destroy the Booster and

No Yes Yes Yes

X1(low)

X2(moderate)

X4(high)

X5(very high)

High &StandardStandard HighNone

StandardStandardStandard Standard

Booster Required

Bottom Spring

Top Spring

Stiffness

10° 10° 10° 10°Max. ROM

1 2 3 4SPRINGCONFIGURATION

*Figure 1

Spring Configurations

Stirrup Options

The fabrication tool kit includes fabrication dummies, alignment axis, attachment hardware and wrenches.

Accessories

Fabrication Tool KitModel 3B00-FTK

Camber Axis Triple Action® Companion Joint

Model 751-ATA

Product Data Sheet

Small Adult Ankle Joint( 16mm Systems )

Patent Pending©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 05/01/20

Acorn Regulatory Consultancy Services Limited

Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766

P 012 4626 8456 F 012 4626 8648

*Internal bottom spring under booster is covered with a lifetime warranty for defects in materials and workmanship.

*The Booster Spring Unit cannot be removed from the Triple Action component housing. Doing so will destroy the Booster and void the product warranty.

Y-Stirrup Model 3B76-Y-1

Medial Stirrup

Models 3B76-MEDR-1 & 3B76-MEDL-1

Lateral Stirrup

Models 3B76-LATR-1 & 3B76-LATL-1

Universal Ri vet Stirrup

Model 3B76-R-1